Trifković, Branka

Link to this page

Authority KeyName Variants
orcid::0000-0002-6429-7646
  • Trifković, Branka (13)
Projects

Author's Bibliography

In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry

Puškar, Tatjana; Trifković, Branka; Đurović-Koprivica, Daniela; Kojić, Vesna; Jevremović, Ana; Mirković, Siniša; Eggbeer, Dominic

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2019)

TY  - JOUR
AU  - Puškar, Tatjana
AU  - Trifković, Branka
AU  - Đurović-Koprivica, Daniela
AU  - Kojić, Vesna
AU  - Jevremović, Ana
AU  - Mirković, Siniša
AU  - Eggbeer, Dominic
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2446
AB  - Background/Aim. There is limited published evidence on the cytotoxicity of 3D printed polymer materials for dentistry applications, despite that they are now widely used in medicine. Stereolithography (SLA) is one of the foremost 3D processes used in 3D printing, yet there are only a small number of resin materials reported to be suitable for medical applications. The aim of this study was to investigate, in vitro, the cytotoxic effect of the 3D printed resin in order to establish the suitability for its usage in dentistry and related medical applications such as surgical dental guides, occlusal splits and orthodontic devices. Methods. To examine the cytotoxicity of the 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA), two cell cultures were used: mouse fibroblasts L929, and human lung fibroblasts MRC-5. The cell viability was determined by the Mosmann's colorimetric (MTT) test and the agar diffusion test (ADT). Results. Direct contact of the tested material with the ADT test showed nontoxic effects of tested material in any cell culture. The tested material showed no cytotoxic effect after 3 days of extraction of the eluate by the MTT, but mild cytotoxic effect after 5, 7 and 21 days on both cell lines. The cytotoxicity increased with increasing the time of the eluate extraction. Conclusion. The 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA) is considered appropriate for making surgical dental implant guides according to the cytotoxic behavior. According to the mild level of cytotoxicity after the longer extraction periods, there is a need for further evaluation of biocompatibility for its application for the occlusal splints and orthodontic devices.
AB  - Uvod/Cilj. Malo je objavljenih dokaza o citotoksičnosti 3D štampanih polimernih materijala za upotrebu u stomatologiji, bez obzira na njihovu sve širu primenu u medicini. Stereolitografija (SLA) jedan je od najvažnijih 3D procesa koji se primenjuje za 3D štampu, ali postoji samo Mali broj materijala na bazi smola za koje je dokazano da su pogodni za medicinsku primenu. Cilj ove studije je bio da se ispita, in vitro, citotoksični efekat 3D štampanog polimera kako bi se utvrdila mogućnost za njegovu upotrebu u stomatologiji i srodnim medicinskim oblastima, kao što su hirurške dentalne vođice, okluzalni splintovi i ortodontski aparati. Metode. Da bi se ispitala citotoksičnost 3D štampanog polimera na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA), korišc'ene su dve c'elijske kulture: fibroblasti miša L929 i humani fibroplasti pluc'a MRC-5. Vijabilnost c'elija utvrđena je Mosmannovim kolorimetrijskim testom (MTT) i testom difuzije agara (ADT). Rezultati. Direktan kontakt testiranog materijala ispitan pomoću ADT pokazao je da materijal nije imao citotoksičan efekat ni na jednu ćelijsku kulturu. Testitrani materijal je imao blag citotoksični efekat posle 5, 7 i 21 dana ekstrakcije eluata primenom MTT na obe ćelijske linije. Citotoksičnost je rasla sa produženjem vremena ekstrakcije eluata. Zaključak. 3D štampani polimer na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA) se može smatrati pogodnim za izradu hirurških dentalnih implantnih vođica sa tačke gledišta njegovog citotoksičnog uticaja. Zbog pokazanih blagih citotoksičnih efekata nakon dužih ekstrakcionih perioda eluata potrebna su dalja istraživanja u oblasti biokompatibilnosti materijala da bi se taj polimer mogao koristiti za izradu okluzalnih splintova i ortodontskih aparata.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry
T1  - In vitro procena citotoksičnosti 3D štampanog polimera na bazi epoksi smole namenjenog za upotrebu u stomatologiji
VL  - 76
IS  - 5
SP  - 502
EP  - 509
DO  - 10.2298/VSP170721127P
ER  - 
@article{
author = "Puškar, Tatjana and Trifković, Branka and Đurović-Koprivica, Daniela and Kojić, Vesna and Jevremović, Ana and Mirković, Siniša and Eggbeer, Dominic",
year = "2019",
abstract = "Background/Aim. There is limited published evidence on the cytotoxicity of 3D printed polymer materials for dentistry applications, despite that they are now widely used in medicine. Stereolithography (SLA) is one of the foremost 3D processes used in 3D printing, yet there are only a small number of resin materials reported to be suitable for medical applications. The aim of this study was to investigate, in vitro, the cytotoxic effect of the 3D printed resin in order to establish the suitability for its usage in dentistry and related medical applications such as surgical dental guides, occlusal splits and orthodontic devices. Methods. To examine the cytotoxicity of the 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA), two cell cultures were used: mouse fibroblasts L929, and human lung fibroblasts MRC-5. The cell viability was determined by the Mosmann's colorimetric (MTT) test and the agar diffusion test (ADT). Results. Direct contact of the tested material with the ADT test showed nontoxic effects of tested material in any cell culture. The tested material showed no cytotoxic effect after 3 days of extraction of the eluate by the MTT, but mild cytotoxic effect after 5, 7 and 21 days on both cell lines. The cytotoxicity increased with increasing the time of the eluate extraction. Conclusion. The 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA) is considered appropriate for making surgical dental implant guides according to the cytotoxic behavior. According to the mild level of cytotoxicity after the longer extraction periods, there is a need for further evaluation of biocompatibility for its application for the occlusal splints and orthodontic devices., Uvod/Cilj. Malo je objavljenih dokaza o citotoksičnosti 3D štampanih polimernih materijala za upotrebu u stomatologiji, bez obzira na njihovu sve širu primenu u medicini. Stereolitografija (SLA) jedan je od najvažnijih 3D procesa koji se primenjuje za 3D štampu, ali postoji samo Mali broj materijala na bazi smola za koje je dokazano da su pogodni za medicinsku primenu. Cilj ove studije je bio da se ispita, in vitro, citotoksični efekat 3D štampanog polimera kako bi se utvrdila mogućnost za njegovu upotrebu u stomatologiji i srodnim medicinskim oblastima, kao što su hirurške dentalne vođice, okluzalni splintovi i ortodontski aparati. Metode. Da bi se ispitala citotoksičnost 3D štampanog polimera na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA), korišc'ene su dve c'elijske kulture: fibroblasti miša L929 i humani fibroplasti pluc'a MRC-5. Vijabilnost c'elija utvrđena je Mosmannovim kolorimetrijskim testom (MTT) i testom difuzije agara (ADT). Rezultati. Direktan kontakt testiranog materijala ispitan pomoću ADT pokazao je da materijal nije imao citotoksičan efekat ni na jednu ćelijsku kulturu. Testitrani materijal je imao blag citotoksični efekat posle 5, 7 i 21 dana ekstrakcije eluata primenom MTT na obe ćelijske linije. Citotoksičnost je rasla sa produženjem vremena ekstrakcije eluata. Zaključak. 3D štampani polimer na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA) se može smatrati pogodnim za izradu hirurških dentalnih implantnih vođica sa tačke gledišta njegovog citotoksičnog uticaja. Zbog pokazanih blagih citotoksičnih efekata nakon dužih ekstrakcionih perioda eluata potrebna su dalja istraživanja u oblasti biokompatibilnosti materijala da bi se taj polimer mogao koristiti za izradu okluzalnih splintova i ortodontskih aparata.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry, In vitro procena citotoksičnosti 3D štampanog polimera na bazi epoksi smole namenjenog za upotrebu u stomatologiji",
volume = "76",
number = "5",
pages = "502-509",
doi = "10.2298/VSP170721127P"
}
Puškar, T., Trifković, B., Đurović-Koprivica, D., Kojić, V., Jevremović, A., Mirković, S.,& Eggbeer, D.. (2019). In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 76(5), 502-509.
https://doi.org/10.2298/VSP170721127P
Puškar T, Trifković B, Đurović-Koprivica D, Kojić V, Jevremović A, Mirković S, Eggbeer D. In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry. in Vojnosanitetski pregled. 2019;76(5):502-509.
doi:10.2298/VSP170721127P .
Puškar, Tatjana, Trifković, Branka, Đurović-Koprivica, Daniela, Kojić, Vesna, Jevremović, Ana, Mirković, Siniša, Eggbeer, Dominic, "In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry" in Vojnosanitetski pregled, 76, no. 5 (2019):502-509,
https://doi.org/10.2298/VSP170721127P . .
13
4
12

Color adjustment potential of resin composites

Trifković, Branka; Powers, John M.; Paravina, Rade D.

(Springer Heidelberg, Heidelberg, 2018)

TY  - JOUR
AU  - Trifković, Branka
AU  - Powers, John M.
AU  - Paravina, Rade D.
PY  - 2018
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2284
AB  - The purpose of this study was to evaluate color adjustment potential (CAP) of resin composites. Two shades of each of eight commercial resin composites and one control shade were evaluated. Visual (color competent observers, controlled conditions) and instrumental color evaluations (spectroradiometer, spectrophotometer) were performed. The data were analyzed by analysis of variance, Fisher's PLSD intervals for comparison of means, and Spearman's rank order correlation. Instrumental color adjustment potential (CAP-I) ranged from - 0.51 to 0.74, and corresponding Fisher's PLSD intervals were 0.1 and 0.05, respectively (p  lt  0.0001, power 1.0). Visual color adjustment potential (CAP-V) ranged from 0.10 to 0.78, and corresponding Fisher's PLSD intervals were 0.2 and 0.1, respectively (p  lt  0.0001, power 1.0). The greatest overall color shifting between test shades in isolation and the same shades surrounded by control shade were recorded for HRi ENA enamel, followed by Clearfil Majesty ES2. The highest visual CAP (blending) was recorded for Herculite Ultra, HRi ENA enamel, and Clearfil Majesty ES2. Within the limitation of the study, it was found that color adjustment potential (CAP) was composite and shade-dependent. Positive CAP was recorded both instrumentally and visually for majority of composites and shades. Overall, the measured color difference reduction associated with positive CAP was 31%, while the average visual CAP was 43%. Resin composites with pronounced color adjustment potential interact with surrounding dental restorations. Introduced CAP-V and CAP-I were indirect measurements of blending (optical illusion).
PB  - Springer Heidelberg, Heidelberg
T2  - Clinical Oral Investigations
T1  - Color adjustment potential of resin composites
VL  - 22
IS  - 3
SP  - 1601
EP  - 1607
DO  - 10.1007/s00784-017-2260-6
ER  - 
@article{
author = "Trifković, Branka and Powers, John M. and Paravina, Rade D.",
year = "2018",
abstract = "The purpose of this study was to evaluate color adjustment potential (CAP) of resin composites. Two shades of each of eight commercial resin composites and one control shade were evaluated. Visual (color competent observers, controlled conditions) and instrumental color evaluations (spectroradiometer, spectrophotometer) were performed. The data were analyzed by analysis of variance, Fisher's PLSD intervals for comparison of means, and Spearman's rank order correlation. Instrumental color adjustment potential (CAP-I) ranged from - 0.51 to 0.74, and corresponding Fisher's PLSD intervals were 0.1 and 0.05, respectively (p  lt  0.0001, power 1.0). Visual color adjustment potential (CAP-V) ranged from 0.10 to 0.78, and corresponding Fisher's PLSD intervals were 0.2 and 0.1, respectively (p  lt  0.0001, power 1.0). The greatest overall color shifting between test shades in isolation and the same shades surrounded by control shade were recorded for HRi ENA enamel, followed by Clearfil Majesty ES2. The highest visual CAP (blending) was recorded for Herculite Ultra, HRi ENA enamel, and Clearfil Majesty ES2. Within the limitation of the study, it was found that color adjustment potential (CAP) was composite and shade-dependent. Positive CAP was recorded both instrumentally and visually for majority of composites and shades. Overall, the measured color difference reduction associated with positive CAP was 31%, while the average visual CAP was 43%. Resin composites with pronounced color adjustment potential interact with surrounding dental restorations. Introduced CAP-V and CAP-I were indirect measurements of blending (optical illusion).",
publisher = "Springer Heidelberg, Heidelberg",
journal = "Clinical Oral Investigations",
title = "Color adjustment potential of resin composites",
volume = "22",
number = "3",
pages = "1601-1607",
doi = "10.1007/s00784-017-2260-6"
}
Trifković, B., Powers, J. M.,& Paravina, R. D.. (2018). Color adjustment potential of resin composites. in Clinical Oral Investigations
Springer Heidelberg, Heidelberg., 22(3), 1601-1607.
https://doi.org/10.1007/s00784-017-2260-6
Trifković B, Powers JM, Paravina RD. Color adjustment potential of resin composites. in Clinical Oral Investigations. 2018;22(3):1601-1607.
doi:10.1007/s00784-017-2260-6 .
Trifković, Branka, Powers, John M., Paravina, Rade D., "Color adjustment potential of resin composites" in Clinical Oral Investigations, 22, no. 3 (2018):1601-1607,
https://doi.org/10.1007/s00784-017-2260-6 . .
44
13
33

3d digitization of featureless dental models using close range photogrammetry aided by noise based patterns

Santoši, Željko; Budak, Igor; Sokac, Mario; Puškar, Tatjana; Vukelić, Đorđe; Trifković, Branka

(Univerzitet u Nišu, Niš, 2018)

TY  - JOUR
AU  - Santoši, Željko
AU  - Budak, Igor
AU  - Sokac, Mario
AU  - Puškar, Tatjana
AU  - Vukelić, Đorđe
AU  - Trifković, Branka
PY  - 2018
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2270
AB  - Development and improvement of 3D digitizing systems provide for the ability to digitize a growing number of materials and geometrical forms of greater complexity. This paper presents the application of 3D digitizing system using close range photogrammetry on the upper jaw cast in plaster in order to obtain its 3D model. Because of the low visual characteristics of gypsum, such as color and texture, many questions arise about the possibility of applying this particular method to this type of physical models. In order to overcome bad visual properties of gypsum, this paper analyzes the possibility of the photogrammetry method application supported by the projected light texture which is based on patterns in the form of noise-obtained mathematically modeled functions. In order to determine the selected image for light texture which gives the better results, an experiment was designed and carried out. Only two images were tested. One image is selected based on previous research and the other one was generated by the Matlab function for uniformly distributed random numbers. For validation and a comparative analysis of the results, an object of 3D digitization was generated with and without projected light texture. CAD inspection was applied for the analysis of the obtained 3D digitizing results. 3D model obtained by approved professional optical 3D scanner as a reference was used. The results in this paper confirm better accuracy of 3D models obtained with the use of light textures, but this approach requires additional hardware and setup adjustment for images acquisition.
PB  - Univerzitet u Nišu, Niš
T2  - Facta Universitatis - Series Mechanical Engineering
T1  - 3d digitization of featureless dental models using close range photogrammetry aided by noise based patterns
VL  - 16
IS  - 3
SP  - 297
EP  - 305
DO  - 10.22190/FUME170620029S
ER  - 
@article{
author = "Santoši, Željko and Budak, Igor and Sokac, Mario and Puškar, Tatjana and Vukelić, Đorđe and Trifković, Branka",
year = "2018",
abstract = "Development and improvement of 3D digitizing systems provide for the ability to digitize a growing number of materials and geometrical forms of greater complexity. This paper presents the application of 3D digitizing system using close range photogrammetry on the upper jaw cast in plaster in order to obtain its 3D model. Because of the low visual characteristics of gypsum, such as color and texture, many questions arise about the possibility of applying this particular method to this type of physical models. In order to overcome bad visual properties of gypsum, this paper analyzes the possibility of the photogrammetry method application supported by the projected light texture which is based on patterns in the form of noise-obtained mathematically modeled functions. In order to determine the selected image for light texture which gives the better results, an experiment was designed and carried out. Only two images were tested. One image is selected based on previous research and the other one was generated by the Matlab function for uniformly distributed random numbers. For validation and a comparative analysis of the results, an object of 3D digitization was generated with and without projected light texture. CAD inspection was applied for the analysis of the obtained 3D digitizing results. 3D model obtained by approved professional optical 3D scanner as a reference was used. The results in this paper confirm better accuracy of 3D models obtained with the use of light textures, but this approach requires additional hardware and setup adjustment for images acquisition.",
publisher = "Univerzitet u Nišu, Niš",
journal = "Facta Universitatis - Series Mechanical Engineering",
title = "3d digitization of featureless dental models using close range photogrammetry aided by noise based patterns",
volume = "16",
number = "3",
pages = "297-305",
doi = "10.22190/FUME170620029S"
}
Santoši, Ž., Budak, I., Sokac, M., Puškar, T., Vukelić, Đ.,& Trifković, B.. (2018). 3d digitization of featureless dental models using close range photogrammetry aided by noise based patterns. in Facta Universitatis - Series Mechanical Engineering
Univerzitet u Nišu, Niš., 16(3), 297-305.
https://doi.org/10.22190/FUME170620029S
Santoši Ž, Budak I, Sokac M, Puškar T, Vukelić Đ, Trifković B. 3d digitization of featureless dental models using close range photogrammetry aided by noise based patterns. in Facta Universitatis - Series Mechanical Engineering. 2018;16(3):297-305.
doi:10.22190/FUME170620029S .
Santoši, Željko, Budak, Igor, Sokac, Mario, Puškar, Tatjana, Vukelić, Đorđe, Trifković, Branka, "3d digitization of featureless dental models using close range photogrammetry aided by noise based patterns" in Facta Universitatis - Series Mechanical Engineering, 16, no. 3 (2018):297-305,
https://doi.org/10.22190/FUME170620029S . .
5
4
7

Advanced procedure for fabrication of substructure in dentistry

Matin, I.; Hadžistević, Miodrag; Vukelić, Đorđe; Trifković, Branka; Potran, Michal; Brajlih, T.; Drstvensek, I.

(Faculty of Metallurgy, 2016)

TY  - JOUR
AU  - Matin, I.
AU  - Hadžistević, Miodrag
AU  - Vukelić, Đorđe
AU  - Trifković, Branka
AU  - Potran, Michal
AU  - Brajlih, T.
AU  - Drstvensek, I.
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2150
AB  - The paper presents some aspects of the novel integrated system, procedure for fabrication of metal substructure of metal-ceramic crowns. The results been shown that the CAD/CAE/RP technology integration presented in this paper can be fully applied to casting metal substructures. The substructure fabricated in this way, confirm the reduction of the total manufacturing time, with an increase in the percentage of high quality castings that use integrated system.
PB  - Faculty of Metallurgy
T2  - Metalurgija
T1  - Advanced procedure for fabrication of substructure in dentistry
VL  - 55
IS  - 4
SP  - 761
EP  - 764
UR  - https://hdl.handle.net/21.15107/rcub_smile_2150
ER  - 
@article{
author = "Matin, I. and Hadžistević, Miodrag and Vukelić, Đorđe and Trifković, Branka and Potran, Michal and Brajlih, T. and Drstvensek, I.",
year = "2016",
abstract = "The paper presents some aspects of the novel integrated system, procedure for fabrication of metal substructure of metal-ceramic crowns. The results been shown that the CAD/CAE/RP technology integration presented in this paper can be fully applied to casting metal substructures. The substructure fabricated in this way, confirm the reduction of the total manufacturing time, with an increase in the percentage of high quality castings that use integrated system.",
publisher = "Faculty of Metallurgy",
journal = "Metalurgija",
title = "Advanced procedure for fabrication of substructure in dentistry",
volume = "55",
number = "4",
pages = "761-764",
url = "https://hdl.handle.net/21.15107/rcub_smile_2150"
}
Matin, I., Hadžistević, M., Vukelić, Đ., Trifković, B., Potran, M., Brajlih, T.,& Drstvensek, I.. (2016). Advanced procedure for fabrication of substructure in dentistry. in Metalurgija
Faculty of Metallurgy., 55(4), 761-764.
https://hdl.handle.net/21.15107/rcub_smile_2150
Matin I, Hadžistević M, Vukelić Đ, Trifković B, Potran M, Brajlih T, Drstvensek I. Advanced procedure for fabrication of substructure in dentistry. in Metalurgija. 2016;55(4):761-764.
https://hdl.handle.net/21.15107/rcub_smile_2150 .
Matin, I., Hadžistević, Miodrag, Vukelić, Đorđe, Trifković, Branka, Potran, Michal, Brajlih, T., Drstvensek, I., "Advanced procedure for fabrication of substructure in dentistry" in Metalurgija, 55, no. 4 (2016):761-764,
https://hdl.handle.net/21.15107/rcub_smile_2150 .
1
1

Measurement of the accuracy of dental working casts using a coordinate measuring machine

Potran, Michal; Štrbac, Branko; Puškar, Tatjana; Hadžistević, Miodrag; Hodolič, Janko; Trifković, Branka

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2016)

TY  - JOUR
AU  - Potran, Michal
AU  - Štrbac, Branko
AU  - Puškar, Tatjana
AU  - Hadžistević, Miodrag
AU  - Hodolič, Janko
AU  - Trifković, Branka
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2080
AB  - Background/Aim. Dental impressions present a negative imprint of intraoral tissues of a patient which is, by pouring in gypsum, transferred extraorally on the working cast. Casting an accurate and precise working cast presents the first and very important step, since each of the following stages contributes to the overall error of the production process, which can lead to inadequately fitting dental restorations. The aim of this study was to promote and test a new model and technique for in vitro evaluation of the dental impression accuracy, as well as to asses the dimensional stability of impression material depending on the material bulk, and its effect on the accuracy of working casts. Methods. Impressions were made by the monophasic technique using the experimental master model. Custom trays with spacing of 1, 2 and 3 mm were constructed by rapid prototyping. The overall of 10 impressions were made with each custom tray. Working casts were made with gypsum type IV. Measurement of working casts was done 24 h later using a coordinate measuring machine. Results. The obtained results show that the working casts of all the three custom trays were in most cases significantly different in the transversal and sagittal planes in relation to the master model. The height of abutments was mainly unaffected. The degree of convergence showed certain significance in all the three custom trays, most pronounced in the tray with 3 mm spacing. Conclusion. The impression material bulk of 1-3 mm could provide accurate working casts when using the monophasic impression technique. The increase of the distance between abutment teeth influences the accuracy of working casts depending on the material bulk.
AB  - Uvod/Cilj. Otisak predstavlja negativ intraoralnih tkiva, čijim se izlivanjem u gipsu njihova morfologija prenosi ekstraoralno na budući radni model. Sa laboratorijskog aspekta izrade zubnih nadoknada, izlivanje tačnog i preciznog radnog modela predstavlja prvi i veoma bitan korak, pošto svaka sledeća faza doprinosi daljem povećanju greške tokom izrade, što za krajnji ishod može imati neodgovarajuću zubnu nadoknadu. Cilj istraživanja bio je da se ispitaju novi model i tehnika za in vitro procenu preciznosti zubnih otisaka, kao i da se odredi uticaj količine otisnog materijala na dimenzionu stabilnost otisaka i preciznost izrade radnih modela. Metode. Za uzimanje otisaka korišćena je monofazna tehnika otiskivanja. Individualne kašike sa međuprostorom od 1, 2 i 3 mm napravljene su aditivnom tehnologijom za brzu izradu prototipova. Sa svakom kašikom napravljeno je po 10 otisaka. Radni modeli izlivani su u gipsu tipa IV. Merenje radnih modela vršeno je nakon 24 sata na koordinatnoj mernoj mašini. Rezultati. Rezultati pokazuju da radni modeli napravljeni pomoću sve tri individulane kašike u transverzalnoj i sagitalnoj ravni značajno odstupaju od glavnog dela modela. Visina patrljaka je u većini slučajeva bila kao na glavnom modelu. Stepen konvergencije pokazao je određena odstupanja samo kod kašike sa međuprostorom od 3 mm. Zaključak. Monofazna tehnika otiskivanja i otisni materijal debljine od 1 do 3 mm obezbeđuju izradu preciznih radnih modela. Rastojanje između zubnih patrljaka utiče na preciznost izrade radnih modela u zavisnosti od količine otisnog materijala.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Measurement of the accuracy of dental working casts using a coordinate measuring machine
T1  - Ispitivanje preciznosti radnih modela pomoću koordinatne merne mašine u stomatologiji
VL  - 73
IS  - 10
SP  - 895
EP  - 903
DO  - 10.2298/VSP150105089P
ER  - 
@article{
author = "Potran, Michal and Štrbac, Branko and Puškar, Tatjana and Hadžistević, Miodrag and Hodolič, Janko and Trifković, Branka",
year = "2016",
abstract = "Background/Aim. Dental impressions present a negative imprint of intraoral tissues of a patient which is, by pouring in gypsum, transferred extraorally on the working cast. Casting an accurate and precise working cast presents the first and very important step, since each of the following stages contributes to the overall error of the production process, which can lead to inadequately fitting dental restorations. The aim of this study was to promote and test a new model and technique for in vitro evaluation of the dental impression accuracy, as well as to asses the dimensional stability of impression material depending on the material bulk, and its effect on the accuracy of working casts. Methods. Impressions were made by the monophasic technique using the experimental master model. Custom trays with spacing of 1, 2 and 3 mm were constructed by rapid prototyping. The overall of 10 impressions were made with each custom tray. Working casts were made with gypsum type IV. Measurement of working casts was done 24 h later using a coordinate measuring machine. Results. The obtained results show that the working casts of all the three custom trays were in most cases significantly different in the transversal and sagittal planes in relation to the master model. The height of abutments was mainly unaffected. The degree of convergence showed certain significance in all the three custom trays, most pronounced in the tray with 3 mm spacing. Conclusion. The impression material bulk of 1-3 mm could provide accurate working casts when using the monophasic impression technique. The increase of the distance between abutment teeth influences the accuracy of working casts depending on the material bulk., Uvod/Cilj. Otisak predstavlja negativ intraoralnih tkiva, čijim se izlivanjem u gipsu njihova morfologija prenosi ekstraoralno na budući radni model. Sa laboratorijskog aspekta izrade zubnih nadoknada, izlivanje tačnog i preciznog radnog modela predstavlja prvi i veoma bitan korak, pošto svaka sledeća faza doprinosi daljem povećanju greške tokom izrade, što za krajnji ishod može imati neodgovarajuću zubnu nadoknadu. Cilj istraživanja bio je da se ispitaju novi model i tehnika za in vitro procenu preciznosti zubnih otisaka, kao i da se odredi uticaj količine otisnog materijala na dimenzionu stabilnost otisaka i preciznost izrade radnih modela. Metode. Za uzimanje otisaka korišćena je monofazna tehnika otiskivanja. Individualne kašike sa međuprostorom od 1, 2 i 3 mm napravljene su aditivnom tehnologijom za brzu izradu prototipova. Sa svakom kašikom napravljeno je po 10 otisaka. Radni modeli izlivani su u gipsu tipa IV. Merenje radnih modela vršeno je nakon 24 sata na koordinatnoj mernoj mašini. Rezultati. Rezultati pokazuju da radni modeli napravljeni pomoću sve tri individulane kašike u transverzalnoj i sagitalnoj ravni značajno odstupaju od glavnog dela modela. Visina patrljaka je u većini slučajeva bila kao na glavnom modelu. Stepen konvergencije pokazao je određena odstupanja samo kod kašike sa međuprostorom od 3 mm. Zaključak. Monofazna tehnika otiskivanja i otisni materijal debljine od 1 do 3 mm obezbeđuju izradu preciznih radnih modela. Rastojanje između zubnih patrljaka utiče na preciznost izrade radnih modela u zavisnosti od količine otisnog materijala.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Measurement of the accuracy of dental working casts using a coordinate measuring machine, Ispitivanje preciznosti radnih modela pomoću koordinatne merne mašine u stomatologiji",
volume = "73",
number = "10",
pages = "895-903",
doi = "10.2298/VSP150105089P"
}
Potran, M., Štrbac, B., Puškar, T., Hadžistević, M., Hodolič, J.,& Trifković, B.. (2016). Measurement of the accuracy of dental working casts using a coordinate measuring machine. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 73(10), 895-903.
https://doi.org/10.2298/VSP150105089P
Potran M, Štrbac B, Puškar T, Hadžistević M, Hodolič J, Trifković B. Measurement of the accuracy of dental working casts using a coordinate measuring machine. in Vojnosanitetski pregled. 2016;73(10):895-903.
doi:10.2298/VSP150105089P .
Potran, Michal, Štrbac, Branko, Puškar, Tatjana, Hadžistević, Miodrag, Hodolič, Janko, Trifković, Branka, "Measurement of the accuracy of dental working casts using a coordinate measuring machine" in Vojnosanitetski pregled, 73, no. 10 (2016):895-903,
https://doi.org/10.2298/VSP150105089P . .
4
1

Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide

Lapčević, Ana; Jevremović, Danimir; Trifković, Branka; Santoši, Željko; Vukelić, Đorđe

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2015)

TY  - JOUR
AU  - Lapčević, Ana
AU  - Jevremović, Danimir
AU  - Trifković, Branka
AU  - Santoši, Željko
AU  - Vukelić, Đorđe
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2067
AB  - Daily progress of dentistry, especially in the field of prosthodontics is introducing new materials and technologies. With the increasing need for aesthetically acceptable and non-metal materials, it came to development and improvement of ceramic materials and computer based systems (CA). The patient came in order to compensate the missing left lateral incisor. Since the adjacent teeth are brushed and the print was taken, casted model has been scanned using 3Shape D800 laboratory scanner. Dental restoration has been designed using 3Shape DentalSystem Premium software and the available tools. After completing the virtual design, the data are sent to the program responsible for CAM Zenotec® mini CAD/CAM device. As a result, the compensation with the full morphology was obtained without the need for finishing works.
AB  - Stomatologija, posebno stomatološka protetika svakodnevno napreduje uvođenjem novih materijala i tehnologija. Kako se javlja sve veća potreba za estetski prihvatljivim i bezmetalnim materijalima, došlo je do razvoja i unapređenja keramičkih materijala i računarima podržanih sistema (CA). Pacijent se javio radi nadoknade nedostajućeg levog bočnog sekutića. Pošto su susedni zubi zbrušeni i uzet otisak, izliven je model koji je skeniran pomoću 3Shape D 800 laboratorijskog skenera. Zubna nadoknada je dizajnirana pomo ću 3Shape DentalSystem Premium softvera korišćenjem raspoloživih alata. Nakon završenog dizajna virtuelni podaci su poslati u program odgovoran za CAM Zenotec® mini CAD/CAM uređaja. Kao rezultat, dobijena je nadoknada pune morfologije bez potrebe za dorađivanjem.
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide
T1  - Primena CAD/CAM tehnologije u projektovanju i izradi mostova pune anatomske forme na bazi cirkonijum-dioksida
VL  - 18
IS  - 1
SP  - 73
EP  - 75
UR  - https://hdl.handle.net/21.15107/rcub_smile_2067
ER  - 
@article{
author = "Lapčević, Ana and Jevremović, Danimir and Trifković, Branka and Santoši, Željko and Vukelić, Đorđe",
year = "2015",
abstract = "Daily progress of dentistry, especially in the field of prosthodontics is introducing new materials and technologies. With the increasing need for aesthetically acceptable and non-metal materials, it came to development and improvement of ceramic materials and computer based systems (CA). The patient came in order to compensate the missing left lateral incisor. Since the adjacent teeth are brushed and the print was taken, casted model has been scanned using 3Shape D800 laboratory scanner. Dental restoration has been designed using 3Shape DentalSystem Premium software and the available tools. After completing the virtual design, the data are sent to the program responsible for CAM Zenotec® mini CAD/CAM device. As a result, the compensation with the full morphology was obtained without the need for finishing works., Stomatologija, posebno stomatološka protetika svakodnevno napreduje uvođenjem novih materijala i tehnologija. Kako se javlja sve veća potreba za estetski prihvatljivim i bezmetalnim materijalima, došlo je do razvoja i unapređenja keramičkih materijala i računarima podržanih sistema (CA). Pacijent se javio radi nadoknade nedostajućeg levog bočnog sekutića. Pošto su susedni zubi zbrušeni i uzet otisak, izliven je model koji je skeniran pomoću 3Shape D 800 laboratorijskog skenera. Zubna nadoknada je dizajnirana pomo ću 3Shape DentalSystem Premium softvera korišćenjem raspoloživih alata. Nakon završenog dizajna virtuelni podaci su poslati u program odgovoran za CAM Zenotec® mini CAD/CAM uređaja. Kao rezultat, dobijena je nadoknada pune morfologije bez potrebe za dorađivanjem.",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide, Primena CAD/CAM tehnologije u projektovanju i izradi mostova pune anatomske forme na bazi cirkonijum-dioksida",
volume = "18",
number = "1",
pages = "73-75",
url = "https://hdl.handle.net/21.15107/rcub_smile_2067"
}
Lapčević, A., Jevremović, D., Trifković, B., Santoši, Ž.,& Vukelić, Đ.. (2015). Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 18(1), 73-75.
https://hdl.handle.net/21.15107/rcub_smile_2067
Lapčević A, Jevremović D, Trifković B, Santoši Ž, Vukelić Đ. Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide. in Journal of Production Engineering. 2015;18(1):73-75.
https://hdl.handle.net/21.15107/rcub_smile_2067 .
Lapčević, Ana, Jevremović, Danimir, Trifković, Branka, Santoši, Željko, Vukelić, Đorđe, "Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide" in Journal of Production Engineering, 18, no. 1 (2015):73-75,
https://hdl.handle.net/21.15107/rcub_smile_2067 .

Mentees: New Leaders or Followers?

Ristić, Ivan; Trifković, Branka; Ghinea, Razvan; Paravina, Rade D.

(Wiley-Blackwell, Hoboken, 2015)

TY  - JOUR
AU  - Ristić, Ivan
AU  - Trifković, Branka
AU  - Ghinea, Razvan
AU  - Paravina, Rade D.
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1997
PB  - Wiley-Blackwell, Hoboken
T2  - Journal of Esthetic & Restorative Dentistry
T1  - Mentees: New Leaders or Followers?
VL  - 27
IS  - 5
SP  - 237
EP  - 239
DO  - 10.1111/jerd.12180
ER  - 
@article{
author = "Ristić, Ivan and Trifković, Branka and Ghinea, Razvan and Paravina, Rade D.",
year = "2015",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Journal of Esthetic & Restorative Dentistry",
title = "Mentees: New Leaders or Followers?",
volume = "27",
number = "5",
pages = "237-239",
doi = "10.1111/jerd.12180"
}
Ristić, I., Trifković, B., Ghinea, R.,& Paravina, R. D.. (2015). Mentees: New Leaders or Followers?. in Journal of Esthetic & Restorative Dentistry
Wiley-Blackwell, Hoboken., 27(5), 237-239.
https://doi.org/10.1111/jerd.12180
Ristić I, Trifković B, Ghinea R, Paravina RD. Mentees: New Leaders or Followers?. in Journal of Esthetic & Restorative Dentistry. 2015;27(5):237-239.
doi:10.1111/jerd.12180 .
Ristić, Ivan, Trifković, Branka, Ghinea, Razvan, Paravina, Rade D., "Mentees: New Leaders or Followers?" in Journal of Esthetic & Restorative Dentistry, 27, no. 5 (2015):237-239,
https://doi.org/10.1111/jerd.12180 . .

Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry

Puškar, Tatjana; Williams, Robert J.; Eggbeer, Dominic; Jevremović, Danimir; Lapčević, Ana; Trifković, Branka; Vukelić, Đorđe

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2013)

TY  - JOUR
AU  - Puškar, Tatjana
AU  - Williams, Robert J.
AU  - Eggbeer, Dominic
AU  - Jevremović, Danimir
AU  - Lapčević, Ana
AU  - Trifković, Branka
AU  - Vukelić, Đorđe
PY  - 2013
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1791
AB  - Corrosion resistance is one of the characteristics that dental alloy should possess as it should be placed in the oral cavity. Adverse tissue reactions of the gingiva and the periodontium close to dental cast alloys may be caused by the effects of released metal elements. Corrosion effect of dental Co-Cr-Mo alloy was investigated by ICP MS according to the EN ISO 10271 and EN ISO 22674. Co- Cr dental alloy Remanium GM 800+ (Dentaurum Ispringen, Germany was tested in artificial saliva for 7 days at 37ºC. The released metals were detected by Nexion 300X ICP MS (Perkin Elmer, USA). The results showed that the metal release was very low for Co, Cr and Mo, far below the permitted levels. ICP-MS can be considered as very reliable method for such a research.
AB  - Otpornost na koroziju je jedna od karakteristika koju poseduju stomatološke legure koje trebaju biti postavljene u usnoj duplji. Neželjene reakcije tkiva gingive i parodoncijuma sa stomatološkim legurama može biti uzrokovano efektima oslobođenih metalnih elemenata. Efekat korozije stomatološke Co- Cr -Mo legure ispitana je ICP MS prema EN ISO 10271 i EN ISO 22674 . Co- Cr stomatološke legure Remanium GM 800 + ( Dentaurum Ispringen , testirano u Nemačkoj u veštačkoj pljuvački tokom 7 dana na 37º C. Otkriveni su oslobođeni metali Nekion 300Ks ICP MS ( Perkin Elmer , SAD ). Rezultati su pokazali veoma slabo oslobađanje metala, Cr i Mo , daleko ispod dozvoljenih nivoa. ICP -MS može smatrati veoma pouzdan metod za ovakvo istraživanje .
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry
T1  - Utvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometrom
VL  - 16
IS  - 1
SP  - 77
EP  - 80
UR  - https://hdl.handle.net/21.15107/rcub_smile_1791
ER  - 
@article{
author = "Puškar, Tatjana and Williams, Robert J. and Eggbeer, Dominic and Jevremović, Danimir and Lapčević, Ana and Trifković, Branka and Vukelić, Đorđe",
year = "2013",
abstract = "Corrosion resistance is one of the characteristics that dental alloy should possess as it should be placed in the oral cavity. Adverse tissue reactions of the gingiva and the periodontium close to dental cast alloys may be caused by the effects of released metal elements. Corrosion effect of dental Co-Cr-Mo alloy was investigated by ICP MS according to the EN ISO 10271 and EN ISO 22674. Co- Cr dental alloy Remanium GM 800+ (Dentaurum Ispringen, Germany was tested in artificial saliva for 7 days at 37ºC. The released metals were detected by Nexion 300X ICP MS (Perkin Elmer, USA). The results showed that the metal release was very low for Co, Cr and Mo, far below the permitted levels. ICP-MS can be considered as very reliable method for such a research., Otpornost na koroziju je jedna od karakteristika koju poseduju stomatološke legure koje trebaju biti postavljene u usnoj duplji. Neželjene reakcije tkiva gingive i parodoncijuma sa stomatološkim legurama može biti uzrokovano efektima oslobođenih metalnih elemenata. Efekat korozije stomatološke Co- Cr -Mo legure ispitana je ICP MS prema EN ISO 10271 i EN ISO 22674 . Co- Cr stomatološke legure Remanium GM 800 + ( Dentaurum Ispringen , testirano u Nemačkoj u veštačkoj pljuvački tokom 7 dana na 37º C. Otkriveni su oslobođeni metali Nekion 300Ks ICP MS ( Perkin Elmer , SAD ). Rezultati su pokazali veoma slabo oslobađanje metala, Cr i Mo , daleko ispod dozvoljenih nivoa. ICP -MS može smatrati veoma pouzdan metod za ovakvo istraživanje .",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry, Utvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometrom",
volume = "16",
number = "1",
pages = "77-80",
url = "https://hdl.handle.net/21.15107/rcub_smile_1791"
}
Puškar, T., Williams, R. J., Eggbeer, D., Jevremović, D., Lapčević, A., Trifković, B.,& Vukelić, Đ.. (2013). Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 16(1), 77-80.
https://hdl.handle.net/21.15107/rcub_smile_1791
Puškar T, Williams RJ, Eggbeer D, Jevremović D, Lapčević A, Trifković B, Vukelić Đ. Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry. in Journal of Production Engineering. 2013;16(1):77-80.
https://hdl.handle.net/21.15107/rcub_smile_1791 .
Puškar, Tatjana, Williams, Robert J., Eggbeer, Dominic, Jevremović, Danimir, Lapčević, Ana, Trifković, Branka, Vukelić, Đorđe, "Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry" in Journal of Production Engineering, 16, no. 1 (2013):77-80,
https://hdl.handle.net/21.15107/rcub_smile_1791 .

Analysis of metrological characteristics of the optical digitization devices in dental CAD/CAM technology

Trifković, Branka

(Univerzitet u Beogradu, Stomatološki fakultet, 2012)

TY  - THES
AU  - Trifković, Branka
PY  - 2012
UR  - http://eteze.bg.ac.rs/application/showtheses?thesesId=601
UR  - https://fedorabg.bg.ac.rs/fedora/get/o:6765/bdef:Content/download
UR  - http://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=1024188558
UR  - http://nardus.mpn.gov.rs/123456789/2693
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/954
AB  - Development and improvement of 3D digitization methods in the last forty years, have enabled that virtual impression in dentistry becomes a reality. Unlike conventional impressions, which represent negative copies of prepared teeth and surrounding tissue, 3D digitization collects data on the coordinates of surface points and transfers them into digital form. Various working principles of 3D digitization methods were the reason, that in the framework of this reasearch to invstigate and compare the basic metrological characteristics of selected optical digitization devices. Based on the hypothesis, following goal of investigation were formulated: to establish whether there is a difference in the accuracy and precision between the optical digitization devices where the process of digitization based on various working principles and determine the degree of measurment uncertainty. The basis of this experiment is CAD inspection. CAD inspection was used to measure and analyze deviations between the CAD reference model and experimental CAD models. In this way is possibile to determine the precision and accuracy of the observed optical digital device. The experimental CAD models were generated by 3D digitization of the stone replica using Cerec® AC (Sirona, Germany), Cerec® In Eos Blue (Sirona, Germany), Trios (3 shape AS, Denmark), KaVo Everest (KaVo, Germany) and Sinergia Scan (Nobil - Metal, S.p.A. Italy) surface digitization devices. The CAD master model was generated by 3D digitization of the stone replica, using Atos III Triple Scan surface digitization device. Processing of the measured results included 2D and 3D analysis. The results of 3D analysis showed thet the highest level of precision in the proceeding of digitizing the right half of upper dental arch are present in Sinergia Scan, then follow KaVo Everest, Trios, Cerec®InEos Blue i Cerec®AC devices. The highest level of accuracy in the same procedure have Cerec®InEos Blue, follow the Sinergia Scan, Cerec®AC i KaVo Everest...
AB  - Razvoj i unapređenje metoda 3D digitalizacije u proteklih četrdeset godina, omogućio je da se ideja o primeni digitalnog otiska u stomatologiji pretvori u stvarnost. Za razliku od konvencionalnog otiska koji predstavlja kopiju zuba i okolnih tkiva u negativu, 3D digitalizacija je postupak u okviru koga se vrši prikupljanje podataka u vidu koordinata – tačaka i obavla njihovo prevođenje u digitalnu formu. Razlike u radnim principima postupaka 3D digitalizacije predstavljale su povod da se u okviru istraživanja ispitaju i uporede osnovne metrološke karakteristike odabranih uređaja za optičku digitalizaciju, koji se primenjuju u stomatološkoj praksi. Na osnovu postavljene hipoteze definisan je osnovni cilj istraživanja: utvrditi da li postoji razlika u preciznosti i tačnosti između uređaja za optičku digitalizaciju kod kojih je postupak digitalizacije zasnovan na različitim radnim principima i na osnovu toga proceniti stepen njihove merne nesigurnosti. Osnovu eksperimenta čini metoda CAD inspekcije, čijom primenom je moguće izvršiti kvantitativnu i kvalitativnu analizu izmerenih odstupanja uzoraka CAD eksperimentalnih modela u odnosu na CAD master model i na taj način utvrdi stepen preciznosti i tačnosti posmatranih uređaja. CAD eksperimentalni uzorci su nastali u postupku digitalizacije osnovnog modela od gipsa pomoću sledećih uređaja: Cerec®AC (Sirona, Germany), Cerec® InEos Blue (Sirona, Germany), Trios (3 shape AS, Denmark), KaVo Everest (KaVo, Germany) i Sinergia Scan (Nobil - Metal, S.p.A. Italy). Digitalizacijom osnovnog modela pomoću industrijskog optičkog uređaja Atos III Triple Scan dobijen je CAD master model. Obrada izmerenih rezultata obuhvatala je 3D i 2D analizu. Rezultati 3D analize prikazuju da je najviši stepen preciznosti uređaja u postupku digitalizacije desne polovine zubnog luka gornje vilice prisutan kod Sinergia Scan, slede KaVo Everest, Trios, Cerec®InEos Blue i Cerec®AC uređaji. Najviši stepen tačnosti u istom postupku ima Cerec®InEos Blue, slede Sinergia Scan, Cerec®AC i KaVo Everest uređaji. Dobijeni rezultati potvrđuju da uređaji za ekstraoralnu digitalizaciju imaju viši stepen tačnosti i preciznosti u odnosu na uređaje za intraoralnu digitalizaciju...
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Analysis of metrological characteristics of the optical digitization devices in dental CAD/CAM technology
T1  - Analiza metroloških karakteristika uređaja za optičku digitalizaciju stomatoloških CAD/CAM sistema
UR  - https://hdl.handle.net/21.15107/rcub_nardus_2693
ER  - 
@phdthesis{
author = "Trifković, Branka",
year = "2012",
abstract = "Development and improvement of 3D digitization methods in the last forty years, have enabled that virtual impression in dentistry becomes a reality. Unlike conventional impressions, which represent negative copies of prepared teeth and surrounding tissue, 3D digitization collects data on the coordinates of surface points and transfers them into digital form. Various working principles of 3D digitization methods were the reason, that in the framework of this reasearch to invstigate and compare the basic metrological characteristics of selected optical digitization devices. Based on the hypothesis, following goal of investigation were formulated: to establish whether there is a difference in the accuracy and precision between the optical digitization devices where the process of digitization based on various working principles and determine the degree of measurment uncertainty. The basis of this experiment is CAD inspection. CAD inspection was used to measure and analyze deviations between the CAD reference model and experimental CAD models. In this way is possibile to determine the precision and accuracy of the observed optical digital device. The experimental CAD models were generated by 3D digitization of the stone replica using Cerec® AC (Sirona, Germany), Cerec® In Eos Blue (Sirona, Germany), Trios (3 shape AS, Denmark), KaVo Everest (KaVo, Germany) and Sinergia Scan (Nobil - Metal, S.p.A. Italy) surface digitization devices. The CAD master model was generated by 3D digitization of the stone replica, using Atos III Triple Scan surface digitization device. Processing of the measured results included 2D and 3D analysis. The results of 3D analysis showed thet the highest level of precision in the proceeding of digitizing the right half of upper dental arch are present in Sinergia Scan, then follow KaVo Everest, Trios, Cerec®InEos Blue i Cerec®AC devices. The highest level of accuracy in the same procedure have Cerec®InEos Blue, follow the Sinergia Scan, Cerec®AC i KaVo Everest..., Razvoj i unapređenje metoda 3D digitalizacije u proteklih četrdeset godina, omogućio je da se ideja o primeni digitalnog otiska u stomatologiji pretvori u stvarnost. Za razliku od konvencionalnog otiska koji predstavlja kopiju zuba i okolnih tkiva u negativu, 3D digitalizacija je postupak u okviru koga se vrši prikupljanje podataka u vidu koordinata – tačaka i obavla njihovo prevođenje u digitalnu formu. Razlike u radnim principima postupaka 3D digitalizacije predstavljale su povod da se u okviru istraživanja ispitaju i uporede osnovne metrološke karakteristike odabranih uređaja za optičku digitalizaciju, koji se primenjuju u stomatološkoj praksi. Na osnovu postavljene hipoteze definisan je osnovni cilj istraživanja: utvrditi da li postoji razlika u preciznosti i tačnosti između uređaja za optičku digitalizaciju kod kojih je postupak digitalizacije zasnovan na različitim radnim principima i na osnovu toga proceniti stepen njihove merne nesigurnosti. Osnovu eksperimenta čini metoda CAD inspekcije, čijom primenom je moguće izvršiti kvantitativnu i kvalitativnu analizu izmerenih odstupanja uzoraka CAD eksperimentalnih modela u odnosu na CAD master model i na taj način utvrdi stepen preciznosti i tačnosti posmatranih uređaja. CAD eksperimentalni uzorci su nastali u postupku digitalizacije osnovnog modela od gipsa pomoću sledećih uređaja: Cerec®AC (Sirona, Germany), Cerec® InEos Blue (Sirona, Germany), Trios (3 shape AS, Denmark), KaVo Everest (KaVo, Germany) i Sinergia Scan (Nobil - Metal, S.p.A. Italy). Digitalizacijom osnovnog modela pomoću industrijskog optičkog uređaja Atos III Triple Scan dobijen je CAD master model. Obrada izmerenih rezultata obuhvatala je 3D i 2D analizu. Rezultati 3D analize prikazuju da je najviši stepen preciznosti uređaja u postupku digitalizacije desne polovine zubnog luka gornje vilice prisutan kod Sinergia Scan, slede KaVo Everest, Trios, Cerec®InEos Blue i Cerec®AC uređaji. Najviši stepen tačnosti u istom postupku ima Cerec®InEos Blue, slede Sinergia Scan, Cerec®AC i KaVo Everest uređaji. Dobijeni rezultati potvrđuju da uređaji za ekstraoralnu digitalizaciju imaju viši stepen tačnosti i preciznosti u odnosu na uređaje za intraoralnu digitalizaciju...",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Analysis of metrological characteristics of the optical digitization devices in dental CAD/CAM technology, Analiza metroloških karakteristika uređaja za optičku digitalizaciju stomatoloških CAD/CAM sistema",
url = "https://hdl.handle.net/21.15107/rcub_nardus_2693"
}
Trifković, B.. (2012). Analysis of metrological characteristics of the optical digitization devices in dental CAD/CAM technology. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_nardus_2693
Trifković B. Analysis of metrological characteristics of the optical digitization devices in dental CAD/CAM technology. 2012;.
https://hdl.handle.net/21.15107/rcub_nardus_2693 .
Trifković, Branka, "Analysis of metrological characteristics of the optical digitization devices in dental CAD/CAM technology" (2012),
https://hdl.handle.net/21.15107/rcub_nardus_2693 .

Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns

Trifković, Branka; Budak, Igor; Todorović, A.; Hodolić, Janko; Puškar, Tatjana; Jevremović, Danimir; Vukelić, Đorđe

(Versita, Warsaw, 2012)

TY  - JOUR
AU  - Trifković, Branka
AU  - Budak, Igor
AU  - Todorović, A.
AU  - Hodolić, Janko
AU  - Puškar, Tatjana
AU  - Jevremović, Danimir
AU  - Vukelić, Đorđe
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1737
AB  - The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
PB  - Versita, Warsaw
T2  - Measurement Science Review
T1  - Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns
VL  - 12
IS  - 3
SP  - 90
EP  - 97
DO  - 10.2478/v10048-012-0016-7
ER  - 
@article{
author = "Trifković, Branka and Budak, Igor and Todorović, A. and Hodolić, Janko and Puškar, Tatjana and Jevremović, Danimir and Vukelić, Đorđe",
year = "2012",
abstract = "The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.",
publisher = "Versita, Warsaw",
journal = "Measurement Science Review",
title = "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns",
volume = "12",
number = "3",
pages = "90-97",
doi = "10.2478/v10048-012-0016-7"
}
Trifković, B., Budak, I., Todorović, A., Hodolić, J., Puškar, T., Jevremović, D.,& Vukelić, Đ.. (2012). Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review
Versita, Warsaw., 12(3), 90-97.
https://doi.org/10.2478/v10048-012-0016-7
Trifković B, Budak I, Todorović A, Hodolić J, Puškar T, Jevremović D, Vukelić Đ. Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review. 2012;12(3):90-97.
doi:10.2478/v10048-012-0016-7 .
Trifković, Branka, Budak, Igor, Todorović, A., Hodolić, Janko, Puškar, Tatjana, Jevremović, Danimir, Vukelić, Đorđe, "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns" in Measurement Science Review, 12, no. 3 (2012):90-97,
https://doi.org/10.2478/v10048-012-0016-7 . .
21
11
25

Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization

Williams, Robert J.; Eggbeer, Dominic; Lapčević, Ana; Trifković, Branka; Puškar, Tatjana; Budak, Igor; Jevremović, Danimir

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2012)

TY  - JOUR
AU  - Williams, Robert J.
AU  - Eggbeer, Dominic
AU  - Lapčević, Ana
AU  - Trifković, Branka
AU  - Puškar, Tatjana
AU  - Budak, Igor
AU  - Jevremović, Danimir
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1701
AB  - CAD/CAM technology in dentistry offers high-end ceramic restorations, known for its quality, preciseness, swiftness and repeatability. However, some features are still human-dependent. A young female patient required smile enhancement, since suffering from colour change on three devitalized frontal teeth. After fiber post placement, teeth were prepared for metal-free restoration. Consequently, abutments were scanned using extraoral scanner (Sirona, InEos Blue; Beinsheim, Germany). CAD software (version 3.8) has been used to create three crown copings, with cut-back in the incisal region. After finalization of the virtual modeling, data file has been transferred to a milling unit (Sirona, MCXL, Beinsheim, Germany) that produced crown copings out of a ceramic block (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtestein). Crowns were tried for the fit and occlusion in the so-called blue stage, after which final strength and shape has been achieved by thermal treatment in the ceramic furnace. Individualization has been done manually, creating special effect in the cut-back region. Crowns were cemented adhesively. CAD/CAM offers modern and relevant way of producing ceramic restorations, however, special effects still require manual adjustments.
AB  - CAD/CAM tehnologije u stomatologiji nude visoko kvalitetne keramičke zamene, poznate po kvalitetu, preciznosti, brzini izrade i ponovljivosti. Međutim neke opcije još uvek zavise od ljudske intervencije. Mlada pacijentkinja je imala zahtev za poboljšanjem osmeha, pošto je patila od promene boje na tri prednja nezdrava zuba. Posle instalacije vlaknene podloge, zubi su bili spremni za bez-metalnu reparaciju. Otisci su bili skenirani ekstraoralnim skenerom (Sirona, InEos Blue, Beinsheim, Nemačka). CAD softver (verzija 3.8) je korišćen za generisanje tri navlake. Po završetku virtuelnog modeliranja podaci su prebačeni na glodalicu (Sirona, MCXL, Beinsheim, Nemačka) koja je izradila navlake od keramičkih blokova (IPS-a, max CAD, Ivoclar Vivadent, Schaan, Lihtenštajn). Navlake su posle isprobane zbog procene naleganja i začepljenja u tzv. plavoj etapi, posle čega je konačno očvršćavanje i oblikovanje postignuto termičkom obradom u peći za keramiku. Individualno prilagođavanje je izvršeno ručno, sa izradom posebnog efekta u zadnjem delu. Navlake su cementirane adhezijom. CAD/CAM nudi moderan i važan način u izradi keramičkih implanta ali posebni efekti još uvek zahtevaju intervenciju čoveka.
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization
T1  - Re-CAD/CAM pristup projektovanju i izradi zubnih keramičkih navlaka u kombinaciji sa ručnim individualnim prilagođavanjem
VL  - 15
IS  - 2
SP  - 91
EP  - 94
UR  - https://hdl.handle.net/21.15107/rcub_smile_1701
ER  - 
@article{
author = "Williams, Robert J. and Eggbeer, Dominic and Lapčević, Ana and Trifković, Branka and Puškar, Tatjana and Budak, Igor and Jevremović, Danimir",
year = "2012",
abstract = "CAD/CAM technology in dentistry offers high-end ceramic restorations, known for its quality, preciseness, swiftness and repeatability. However, some features are still human-dependent. A young female patient required smile enhancement, since suffering from colour change on three devitalized frontal teeth. After fiber post placement, teeth were prepared for metal-free restoration. Consequently, abutments were scanned using extraoral scanner (Sirona, InEos Blue; Beinsheim, Germany). CAD software (version 3.8) has been used to create three crown copings, with cut-back in the incisal region. After finalization of the virtual modeling, data file has been transferred to a milling unit (Sirona, MCXL, Beinsheim, Germany) that produced crown copings out of a ceramic block (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtestein). Crowns were tried for the fit and occlusion in the so-called blue stage, after which final strength and shape has been achieved by thermal treatment in the ceramic furnace. Individualization has been done manually, creating special effect in the cut-back region. Crowns were cemented adhesively. CAD/CAM offers modern and relevant way of producing ceramic restorations, however, special effects still require manual adjustments., CAD/CAM tehnologije u stomatologiji nude visoko kvalitetne keramičke zamene, poznate po kvalitetu, preciznosti, brzini izrade i ponovljivosti. Međutim neke opcije još uvek zavise od ljudske intervencije. Mlada pacijentkinja je imala zahtev za poboljšanjem osmeha, pošto je patila od promene boje na tri prednja nezdrava zuba. Posle instalacije vlaknene podloge, zubi su bili spremni za bez-metalnu reparaciju. Otisci su bili skenirani ekstraoralnim skenerom (Sirona, InEos Blue, Beinsheim, Nemačka). CAD softver (verzija 3.8) je korišćen za generisanje tri navlake. Po završetku virtuelnog modeliranja podaci su prebačeni na glodalicu (Sirona, MCXL, Beinsheim, Nemačka) koja je izradila navlake od keramičkih blokova (IPS-a, max CAD, Ivoclar Vivadent, Schaan, Lihtenštajn). Navlake su posle isprobane zbog procene naleganja i začepljenja u tzv. plavoj etapi, posle čega je konačno očvršćavanje i oblikovanje postignuto termičkom obradom u peći za keramiku. Individualno prilagođavanje je izvršeno ručno, sa izradom posebnog efekta u zadnjem delu. Navlake su cementirane adhezijom. CAD/CAM nudi moderan i važan način u izradi keramičkih implanta ali posebni efekti još uvek zahtevaju intervenciju čoveka.",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization, Re-CAD/CAM pristup projektovanju i izradi zubnih keramičkih navlaka u kombinaciji sa ručnim individualnim prilagođavanjem",
volume = "15",
number = "2",
pages = "91-94",
url = "https://hdl.handle.net/21.15107/rcub_smile_1701"
}
Williams, R. J., Eggbeer, D., Lapčević, A., Trifković, B., Puškar, T., Budak, I.,& Jevremović, D.. (2012). Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 15(2), 91-94.
https://hdl.handle.net/21.15107/rcub_smile_1701
Williams RJ, Eggbeer D, Lapčević A, Trifković B, Puškar T, Budak I, Jevremović D. Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization. in Journal of Production Engineering. 2012;15(2):91-94.
https://hdl.handle.net/21.15107/rcub_smile_1701 .
Williams, Robert J., Eggbeer, Dominic, Lapčević, Ana, Trifković, Branka, Puškar, Tatjana, Budak, Igor, Jevremović, Danimir, "Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization" in Journal of Production Engineering, 15, no. 2 (2012):91-94,
https://hdl.handle.net/21.15107/rcub_smile_1701 .

A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period

Jevremović, Danimir; Bošković, Mirjana V.; Puškar, Tatjana; Williams, Robert J.; Trifković, Branka; Eggbeer, Dominic

(Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš, 2010)

TY  - JOUR
AU  - Jevremović, Danimir
AU  - Bošković, Mirjana V.
AU  - Puškar, Tatjana
AU  - Williams, Robert J.
AU  - Trifković, Branka
AU  - Eggbeer, Dominic
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1546
AB  - Introduction. Inlay retained adhesive restorations present a conservative approach when a single tooth is missing in the posterior region. Material and methods. Twenty five restorations were included in the clinical study. Patient selection, preparation technique as well as denture fabrication followed current principles in this area. Patients were examined every 6 months over a 2 year examination period. Results were statistically analyzed. Results. The success rate for the first year comes to 91.1%, while cumulative success probability during the second year (24 months) was 86.6%. Furthermore, colour, texture and marginal staining were satisfactory during the observation period. Conclusion. Fibre-reinforced composite adhesive dentures are a tooth preserving, minimally invasive, aesthetic and reliable treatment option for single tooth replacement in the posterior area.
AB  - Uvod. Inlej retinirani adhezivni mostovi predstavljaju konzervativni modalitet tretmana nedostatka pojedinačnog zuba u bočnoj regiji. Materijal i metod. U kliničku studiju, uključeno je 25 adhezivnih nadoknada. Odabir pacijenata, principi preparacije, kao i tehnika izrade mostova urađeni su prema važećim standardima u ovoj oblasti. Pacijenti su praćeni na svakih 6 meseci tokom dvogodišnjeg perioda. Rezultati su statistički obrađeni. Rezultati. Uspešnost nadoknada u prvoj godini iznosi 91.1%, dok kumulativna uspešnost tokom druge godine (24 meseca) iznosi 86.6%. Takođe, ocena boje, teksture i marginalnog prebojavanja daje zadovoljavajuće rezulate tokom perioda praćenja. Zaključak. Kompozitne nadoknade ojačane vlaknima su minimalno invazivni, estetski i pouzdan način tretmana minimalne krezubosti bočnog segmenta denticije.
PB  - Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš
T2  - Acta stomatologica Naissi
T1  - A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period
T1  - Klinička evaluacija inlej-retiniranih adhezivnih mostova tokom dvogodišnjeg opservacionog perioda
VL  - 26
IS  - 62
SP  - 997
EP  - 1006
UR  - https://hdl.handle.net/21.15107/rcub_smile_1546
ER  - 
@article{
author = "Jevremović, Danimir and Bošković, Mirjana V. and Puškar, Tatjana and Williams, Robert J. and Trifković, Branka and Eggbeer, Dominic",
year = "2010",
abstract = "Introduction. Inlay retained adhesive restorations present a conservative approach when a single tooth is missing in the posterior region. Material and methods. Twenty five restorations were included in the clinical study. Patient selection, preparation technique as well as denture fabrication followed current principles in this area. Patients were examined every 6 months over a 2 year examination period. Results were statistically analyzed. Results. The success rate for the first year comes to 91.1%, while cumulative success probability during the second year (24 months) was 86.6%. Furthermore, colour, texture and marginal staining were satisfactory during the observation period. Conclusion. Fibre-reinforced composite adhesive dentures are a tooth preserving, minimally invasive, aesthetic and reliable treatment option for single tooth replacement in the posterior area., Uvod. Inlej retinirani adhezivni mostovi predstavljaju konzervativni modalitet tretmana nedostatka pojedinačnog zuba u bočnoj regiji. Materijal i metod. U kliničku studiju, uključeno je 25 adhezivnih nadoknada. Odabir pacijenata, principi preparacije, kao i tehnika izrade mostova urađeni su prema važećim standardima u ovoj oblasti. Pacijenti su praćeni na svakih 6 meseci tokom dvogodišnjeg perioda. Rezultati su statistički obrađeni. Rezultati. Uspešnost nadoknada u prvoj godini iznosi 91.1%, dok kumulativna uspešnost tokom druge godine (24 meseca) iznosi 86.6%. Takođe, ocena boje, teksture i marginalnog prebojavanja daje zadovoljavajuće rezulate tokom perioda praćenja. Zaključak. Kompozitne nadoknade ojačane vlaknima su minimalno invazivni, estetski i pouzdan način tretmana minimalne krezubosti bočnog segmenta denticije.",
publisher = "Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš",
journal = "Acta stomatologica Naissi",
title = "A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period, Klinička evaluacija inlej-retiniranih adhezivnih mostova tokom dvogodišnjeg opservacionog perioda",
volume = "26",
number = "62",
pages = "997-1006",
url = "https://hdl.handle.net/21.15107/rcub_smile_1546"
}
Jevremović, D., Bošković, M. V., Puškar, T., Williams, R. J., Trifković, B.,& Eggbeer, D.. (2010). A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period. in Acta stomatologica Naissi
Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš., 26(62), 997-1006.
https://hdl.handle.net/21.15107/rcub_smile_1546
Jevremović D, Bošković MV, Puškar T, Williams RJ, Trifković B, Eggbeer D. A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period. in Acta stomatologica Naissi. 2010;26(62):997-1006.
https://hdl.handle.net/21.15107/rcub_smile_1546 .
Jevremović, Danimir, Bošković, Mirjana V., Puškar, Tatjana, Williams, Robert J., Trifković, Branka, Eggbeer, Dominic, "A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period" in Acta stomatologica Naissi, 26, no. 62 (2010):997-1006,
https://hdl.handle.net/21.15107/rcub_smile_1546 .
2

Preciznost optičkih metoda skeniranja u stomatološkim CAD/CAD tehnologijama

Trifković, Branka

(Univerzitet u Beogradu, Stomatološki fakultet, 2009)

TY  - THES
AU  - Trifković, Branka
PY  - 2009
UR  - https://plus.sr.cobiss.net/opac7/bib/1024165518
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/487
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Preciznost optičkih metoda skeniranja u stomatološkim CAD/CAD tehnologijama
UR  - https://hdl.handle.net/21.15107/rcub_smile_487
ER  - 
@mastersthesis{
author = "Trifković, Branka",
year = "2009",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Preciznost optičkih metoda skeniranja u stomatološkim CAD/CAD tehnologijama",
url = "https://hdl.handle.net/21.15107/rcub_smile_487"
}
Trifković, B.. (2009). Preciznost optičkih metoda skeniranja u stomatološkim CAD/CAD tehnologijama. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_487
Trifković B. Preciznost optičkih metoda skeniranja u stomatološkim CAD/CAD tehnologijama. 2009;.
https://hdl.handle.net/21.15107/rcub_smile_487 .
Trifković, Branka, "Preciznost optičkih metoda skeniranja u stomatološkim CAD/CAD tehnologijama" (2009),
https://hdl.handle.net/21.15107/rcub_smile_487 .