Šćepanović, Miodrag

Link to this page

Authority KeyName Variants
a062db5d-58b0-40cc-9d12-8355b1ad8a2a
  • Šćepanović, Miodrag (18)
Projects

Author's Bibliography

Histopathological comparative analysis of periimplant bone inflammatory response after dental implant insertion using flap and flapless surgical technique. An experimental study in pigs

Vlahović, Zoran; Marković, Aleksa; Lazić, Zoran; Šćepanović, Miodrag; Đinić, Ana; Kalanović, Milena

(Wiley, Hoboken, 2017)

TY  - JOUR
AU  - Vlahović, Zoran
AU  - Marković, Aleksa
AU  - Lazić, Zoran
AU  - Šćepanović, Miodrag
AU  - Đinić, Ana
AU  - Kalanović, Milena
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2219
AB  - AimTo evaluate by histopathological analysis the peri-implant bone inflammation degree, in certain time intervals (7, 14, 21 and 28days), following mini-incision flapless and flap implant placement. Material and methodsThe experiment was conducted on four domestic pigs. Nine weeks prior to implant insertion, second and third mandibular premolars were extracted. Each animal received six implants in lower jaw. On one randomly chosen side of jaw flapless technique using mini-incision was performed, while on the other side implants were inserted after flap raising. After 7, 14, 21, and 28days, the experimental animals were sacrificed. Following mandibular resection and decalcification, the samples for histopathological analysis of the peri-implant bone were obtained in the empty implant bed area, from the buccal side of the mandible, adjacent to implant neck region and parallel to crestal edge of implant bed. The degree of inflammatory response of the peri-implant bone was estimated through ordinal scores from 0 to 2. ResultsSeven days after the surgery all samples in the flap group had score 2 indicating high inflammation degree, in contrast to lower inflammatory reaction in flapless group. On the 14th and 21st postoperative day decreasing of inflammation degree was noted in all samples of the flapless group (score 1), while in flap group samples presented scores 1 and 2. Twenty-eight days after the implant placement, further reduction of inflammation in the flapless group (33% of samples had score 0) was observed. ConclusionFlapless technique in comparison to conventional flap procedure minimizes postoperative bone inflammatory reactions.
PB  - Wiley, Hoboken
T2  - Clinical Oral Implants Research
T1  - Histopathological comparative analysis of periimplant bone inflammatory response after dental implant insertion using flap and flapless surgical technique. An experimental study in pigs
VL  - 28
IS  - 9
SP  - 1067
EP  - 1073
DO  - 10.1111/clr.12919
ER  - 
@article{
author = "Vlahović, Zoran and Marković, Aleksa and Lazić, Zoran and Šćepanović, Miodrag and Đinić, Ana and Kalanović, Milena",
year = "2017",
abstract = "AimTo evaluate by histopathological analysis the peri-implant bone inflammation degree, in certain time intervals (7, 14, 21 and 28days), following mini-incision flapless and flap implant placement. Material and methodsThe experiment was conducted on four domestic pigs. Nine weeks prior to implant insertion, second and third mandibular premolars were extracted. Each animal received six implants in lower jaw. On one randomly chosen side of jaw flapless technique using mini-incision was performed, while on the other side implants were inserted after flap raising. After 7, 14, 21, and 28days, the experimental animals were sacrificed. Following mandibular resection and decalcification, the samples for histopathological analysis of the peri-implant bone were obtained in the empty implant bed area, from the buccal side of the mandible, adjacent to implant neck region and parallel to crestal edge of implant bed. The degree of inflammatory response of the peri-implant bone was estimated through ordinal scores from 0 to 2. ResultsSeven days after the surgery all samples in the flap group had score 2 indicating high inflammation degree, in contrast to lower inflammatory reaction in flapless group. On the 14th and 21st postoperative day decreasing of inflammation degree was noted in all samples of the flapless group (score 1), while in flap group samples presented scores 1 and 2. Twenty-eight days after the implant placement, further reduction of inflammation in the flapless group (33% of samples had score 0) was observed. ConclusionFlapless technique in comparison to conventional flap procedure minimizes postoperative bone inflammatory reactions.",
publisher = "Wiley, Hoboken",
journal = "Clinical Oral Implants Research",
title = "Histopathological comparative analysis of periimplant bone inflammatory response after dental implant insertion using flap and flapless surgical technique. An experimental study in pigs",
volume = "28",
number = "9",
pages = "1067-1073",
doi = "10.1111/clr.12919"
}
Vlahović, Z., Marković, A., Lazić, Z., Šćepanović, M., Đinić, A.,& Kalanović, M.. (2017). Histopathological comparative analysis of periimplant bone inflammatory response after dental implant insertion using flap and flapless surgical technique. An experimental study in pigs. in Clinical Oral Implants Research
Wiley, Hoboken., 28(9), 1067-1073.
https://doi.org/10.1111/clr.12919
Vlahović Z, Marković A, Lazić Z, Šćepanović M, Đinić A, Kalanović M. Histopathological comparative analysis of periimplant bone inflammatory response after dental implant insertion using flap and flapless surgical technique. An experimental study in pigs. in Clinical Oral Implants Research. 2017;28(9):1067-1073.
doi:10.1111/clr.12919 .
Vlahović, Zoran, Marković, Aleksa, Lazić, Zoran, Šćepanović, Miodrag, Đinić, Ana, Kalanović, Milena, "Histopathological comparative analysis of periimplant bone inflammatory response after dental implant insertion using flap and flapless surgical technique. An experimental study in pigs" in Clinical Oral Implants Research, 28, no. 9 (2017):1067-1073,
https://doi.org/10.1111/clr.12919 . .
6
4
5

Randomized clinical study of the peri-implant healing to hydrophilic and hydrophobic implant surfaces in patients receiving anticoagulants

Marković, Aleksa; Đinić, Ana; Calvo Guirado, Jose Luis; Tahmaseb, Ali; Šćepanović, Miodrag; Janjić, Bojan

(Wiley, Hoboken, 2017)

TY  - JOUR
AU  - Marković, Aleksa
AU  - Đinić, Ana
AU  - Calvo Guirado, Jose Luis
AU  - Tahmaseb, Ali
AU  - Šćepanović, Miodrag
AU  - Janjić, Bojan
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2214
AB  - ObjectivesTo compare the peri-implant bone healing between TiZr implants with hydrophilic SLActive and hydrophobic SLA implant surface in patients receiving anticoagulants, to assess the implant survival and success rate, as well as to evaluate whether small-diameter TiZr implants could be used in patients on OAT in order to avoid augmentation procedures. Material and methodsA total of 80 small-diameter tissue-level TiZr implants with SLActive and SLA surfaces were placed in 20 anticoagulated patients, following the split-mouth study design. Implant stability was measured up to the third postoperative month by resonance frequency measurements (RFA). One-year implant survival and success rate were evaluated. ResultsAfter one year, 100% implant survival and success rate were observed. A significant decrease in ISQ comparing to baseline values was noted in the SLActive group from the first postoperative week, and in the SLA group, from the 3rdweek after the surgery. In both groups, a statistically significant decline in ISQ was observed between second and third postoperative week. No significant differences in ISQ values between SLActive and SLA implants were noted, at any time point. ConclusionsTitanium-zirconium small-diameter implants with SLActive and SLA surface predictably achieve and maintain adequate bone tissue integration in patients receiving anticoagulants. OAT appears to influence the bone healing events resulting in lower ISQ in the end of 3-month period in comparison with baseline values, although without compromising implant stability.
PB  - Wiley, Hoboken
T2  - Clinical Oral Implants Research
T1  - Randomized clinical study of the peri-implant healing to hydrophilic and hydrophobic implant surfaces in patients receiving anticoagulants
VL  - 28
IS  - 10
SP  - 1241
EP  - 1247
DO  - 10.1111/clr.12948
ER  - 
@article{
author = "Marković, Aleksa and Đinić, Ana and Calvo Guirado, Jose Luis and Tahmaseb, Ali and Šćepanović, Miodrag and Janjić, Bojan",
year = "2017",
abstract = "ObjectivesTo compare the peri-implant bone healing between TiZr implants with hydrophilic SLActive and hydrophobic SLA implant surface in patients receiving anticoagulants, to assess the implant survival and success rate, as well as to evaluate whether small-diameter TiZr implants could be used in patients on OAT in order to avoid augmentation procedures. Material and methodsA total of 80 small-diameter tissue-level TiZr implants with SLActive and SLA surfaces were placed in 20 anticoagulated patients, following the split-mouth study design. Implant stability was measured up to the third postoperative month by resonance frequency measurements (RFA). One-year implant survival and success rate were evaluated. ResultsAfter one year, 100% implant survival and success rate were observed. A significant decrease in ISQ comparing to baseline values was noted in the SLActive group from the first postoperative week, and in the SLA group, from the 3rdweek after the surgery. In both groups, a statistically significant decline in ISQ was observed between second and third postoperative week. No significant differences in ISQ values between SLActive and SLA implants were noted, at any time point. ConclusionsTitanium-zirconium small-diameter implants with SLActive and SLA surface predictably achieve and maintain adequate bone tissue integration in patients receiving anticoagulants. OAT appears to influence the bone healing events resulting in lower ISQ in the end of 3-month period in comparison with baseline values, although without compromising implant stability.",
publisher = "Wiley, Hoboken",
journal = "Clinical Oral Implants Research",
title = "Randomized clinical study of the peri-implant healing to hydrophilic and hydrophobic implant surfaces in patients receiving anticoagulants",
volume = "28",
number = "10",
pages = "1241-1247",
doi = "10.1111/clr.12948"
}
Marković, A., Đinić, A., Calvo Guirado, J. L., Tahmaseb, A., Šćepanović, M.,& Janjić, B.. (2017). Randomized clinical study of the peri-implant healing to hydrophilic and hydrophobic implant surfaces in patients receiving anticoagulants. in Clinical Oral Implants Research
Wiley, Hoboken., 28(10), 1241-1247.
https://doi.org/10.1111/clr.12948
Marković A, Đinić A, Calvo Guirado JL, Tahmaseb A, Šćepanović M, Janjić B. Randomized clinical study of the peri-implant healing to hydrophilic and hydrophobic implant surfaces in patients receiving anticoagulants. in Clinical Oral Implants Research. 2017;28(10):1241-1247.
doi:10.1111/clr.12948 .
Marković, Aleksa, Đinić, Ana, Calvo Guirado, Jose Luis, Tahmaseb, Ali, Šćepanović, Miodrag, Janjić, Bojan, "Randomized clinical study of the peri-implant healing to hydrophilic and hydrophobic implant surfaces in patients receiving anticoagulants" in Clinical Oral Implants Research, 28, no. 10 (2017):1241-1247,
https://doi.org/10.1111/clr.12948 . .
13
6
12

Submerged flapless technique vs. conventional flap approach for implant placement: experimental domestic pig study with 12-month follow-up

Perez-Albacete Martinez, Carlos; Vlahović, Zoran; Šćepanović, Miodrag; Videnović, Goran; Barone, Antonio; Calvo Guirado, Jose Luis

(Wiley-Blackwell, Hoboken, 2016)

TY  - JOUR
AU  - Perez-Albacete Martinez, Carlos
AU  - Vlahović, Zoran
AU  - Šćepanović, Miodrag
AU  - Videnović, Goran
AU  - Barone, Antonio
AU  - Calvo Guirado, Jose Luis
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2095
AB  - ObjectivesThe aim of our study was to compare osseointegration and peri-implant crestal bone resorption in submerged flapless and conventional flap surgery over a 12-month follow-up. Materials and methodsThe study used five domestic pigs. Implants were inserted 9weeks after tooth extraction. Each animal received six implants in the mandible, following a split-mouth design: one side was treated using a flapless technique using mini-incisions, while a flap was raised on the other. The animals were sacrificed at 2weeks, 1, 3, 6 and 12months after implant placement. Radiographic images were taken to analyze crestal bone loss, and samples were extracted for histopathological and bone-to-implant contact (BIC) analyses. ResultsSignificantly, greater crestal bone loss (P=0.005) was obtained in the flap group compared with the flapless group. The flapless group presented significantly higher percentages of BIC (P lt 0.05) at 3, 6 and 12months compared with the conventional flap group. ConclusionsWithin the limitations of this experimental animal study, it may be concluded that the type of surgery (flap or flapless) affects peri-implant bone preservation and osseointegration of regular platform implants. Flapless surgery is associated with peri-implant crestal bone preservation. Flapless surgery in combination with submerged implants allows higher osseointegration values.
PB  - Wiley-Blackwell, Hoboken
T2  - Clinical Oral Implants Research
T1  - Submerged flapless technique vs. conventional flap approach for implant placement: experimental domestic pig study with 12-month follow-up
VL  - 27
IS  - 8
SP  - 964
EP  - 968
DO  - 10.1111/clr.12665
ER  - 
@article{
author = "Perez-Albacete Martinez, Carlos and Vlahović, Zoran and Šćepanović, Miodrag and Videnović, Goran and Barone, Antonio and Calvo Guirado, Jose Luis",
year = "2016",
abstract = "ObjectivesThe aim of our study was to compare osseointegration and peri-implant crestal bone resorption in submerged flapless and conventional flap surgery over a 12-month follow-up. Materials and methodsThe study used five domestic pigs. Implants were inserted 9weeks after tooth extraction. Each animal received six implants in the mandible, following a split-mouth design: one side was treated using a flapless technique using mini-incisions, while a flap was raised on the other. The animals were sacrificed at 2weeks, 1, 3, 6 and 12months after implant placement. Radiographic images were taken to analyze crestal bone loss, and samples were extracted for histopathological and bone-to-implant contact (BIC) analyses. ResultsSignificantly, greater crestal bone loss (P=0.005) was obtained in the flap group compared with the flapless group. The flapless group presented significantly higher percentages of BIC (P lt 0.05) at 3, 6 and 12months compared with the conventional flap group. ConclusionsWithin the limitations of this experimental animal study, it may be concluded that the type of surgery (flap or flapless) affects peri-implant bone preservation and osseointegration of regular platform implants. Flapless surgery is associated with peri-implant crestal bone preservation. Flapless surgery in combination with submerged implants allows higher osseointegration values.",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Clinical Oral Implants Research",
title = "Submerged flapless technique vs. conventional flap approach for implant placement: experimental domestic pig study with 12-month follow-up",
volume = "27",
number = "8",
pages = "964-968",
doi = "10.1111/clr.12665"
}
Perez-Albacete Martinez, C., Vlahović, Z., Šćepanović, M., Videnović, G., Barone, A.,& Calvo Guirado, J. L.. (2016). Submerged flapless technique vs. conventional flap approach for implant placement: experimental domestic pig study with 12-month follow-up. in Clinical Oral Implants Research
Wiley-Blackwell, Hoboken., 27(8), 964-968.
https://doi.org/10.1111/clr.12665
Perez-Albacete Martinez C, Vlahović Z, Šćepanović M, Videnović G, Barone A, Calvo Guirado JL. Submerged flapless technique vs. conventional flap approach for implant placement: experimental domestic pig study with 12-month follow-up. in Clinical Oral Implants Research. 2016;27(8):964-968.
doi:10.1111/clr.12665 .
Perez-Albacete Martinez, Carlos, Vlahović, Zoran, Šćepanović, Miodrag, Videnović, Goran, Barone, Antonio, Calvo Guirado, Jose Luis, "Submerged flapless technique vs. conventional flap approach for implant placement: experimental domestic pig study with 12-month follow-up" in Clinical Oral Implants Research, 27, no. 8 (2016):964-968,
https://doi.org/10.1111/clr.12665 . .
1
6
4
6

Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites: Thermographic analysis on bovine ribs

Marković, Aleksa; Lazić, Zoran; Mišić, Tijana; Šćepanović, Miodrag; Todorović, Aleksandar; Thakare, Kaustubh; Janjić, Bojan; Vlahović, Zoran; Glišić, Mirko

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2016)

TY  - JOUR
AU  - Marković, Aleksa
AU  - Lazić, Zoran
AU  - Mišić, Tijana
AU  - Šćepanović, Miodrag
AU  - Todorović, Aleksandar
AU  - Thakare, Kaustubh
AU  - Janjić, Bojan
AU  - Vlahović, Zoran
AU  - Glišić, Mirko
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2081
AB  - Background/Aim. During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and temperature of irrigans on thermal changes of the local bone during drilling implant sites, and to test the influence of irrigans temperature on the temperature of surgical drill guide. Methods. A total of 48 specimens obtained from bovine ribs were randomly allocated to four experimental conditions according to the 2 x 2 factorial design: drill guide (with or without) and saline (at 25°C or 5°C). Real-time infrared thermography was used as a method for temperature measurement. The primary outcome was bone temperature change during drilling implant sites measured at 3 osteotomy depths, whereas the second one was change in the temperature of the drill guide. Data were analyzed by Brunner and Langer nonparametric analysis and Wilcoxon test. Results. The effect of drill guide on the changes of bone temperature was significant at the entrance of osteotomy, whereas the effect of saline temperature was significant at all osteotomy levels (p  lt  0.001). No significant interaction was found (p > 0.05). Guided surgery and irrigation with saline at 25°C were associated with the highest bone temperature increase. Increase in drill guide temperature was significantly higher when saline at 25°C was used (p  lt  0.001). Conclusion. Guided implant site preparation generates higher temperature of the local bone than conventional drilling, not exceeding the threshold for thermal bone necrosis. Although saline at room temperature provides sufficient heat control during drilling, cooled saline is more effective regardless the use of surgical drill guide.
AB  - Uvod/Cilj. Tokom preparacije ležišta za implantat mehanička energija pretvara se u toplotnu, što dovodi do prolaznog povišenja temperature okolne kosti. Temperatura od 47°C tokom više od jednog minuta narušava oseointegraciju, mehaničke osobine lokalne kosti i može dovesti do ranog neuspeha implantata. Cilj ove in vitro studije bio je da se ispita uticaj hirurškog stenta i temperature irigansa na termičke promene u kosti tokom preparacije ležišta za implantat, kao i uticaj temperature irigansa na temperaturu hirurškog stenta. Metode. Ukupno 48 uzoraka dobijenih od goveđih rebara bilo je podeljeno metodom slučajnog izbora u četiri grupe prema 2 x 2 faktorskom dizajnu: prisustvo hirurškog stenta (da/ne) i temperatura fiziološkog rastvora (25°C/5°C). Temperatura je merena infracrvenom termografijom u realnom vremenu. Primarni ishod bio je promena temperature kosti tokom preparacije ležišta implantata merena na tri dubine ležišta, a sekundarni ishod promena temperature hirurškog stenta. Podaci su analizirani Bruner-Langer neparametrijskom analizom i Vilkoksonovim testom. Rezultati. Uticaj hirurškog stenta na promenutemperature kosti bio je značajan na ulazu u ležište za implantat, dok je uticaj temperature irigansa bio značajan na svim dubinama ležišta (p  lt  0,001). Međusobni uticaj ispitivanih faktora nije bio značajan (p > 0,05). Upotreba hirurškog stenta i ispiranje fiziološkim rastvorom temperature 25°C bili su praćeni najvišim porastom temperature kosti. Porast temperature hirurškog stenta bio je značajno viši kada je korišćeno ispiranje na temperaturi od 25°C (p  lt  0,001). Zaključak. Tokom kontrolisane preparacije ležišta za implantat došlo je do većeg zagrevanja kosti u poređenju sa standardnom preparacijom, ne premašujući temperaturu kritičnu za termičku nekrozu kosti. Iako ispiranje na sobnoj temperaturi obezbeđuje dovoljno hlađenja kosti tokom preparacije ležišta za implantat, ohlađeni rastvor za ispiranje je efikasniji bez obzira na primenu hirurškog stenta.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites: Thermographic analysis on bovine ribs
T1  - Uticaj hirurškog stenta i temperature irigansa na termičke promene u kosti tokom preparacije ležišta implantata - termografska analiza na goveđim rebrima
VL  - 73
IS  - 8
SP  - 744
EP  - 750
DO  - 10.2298/VSP141208041M
ER  - 
@article{
author = "Marković, Aleksa and Lazić, Zoran and Mišić, Tijana and Šćepanović, Miodrag and Todorović, Aleksandar and Thakare, Kaustubh and Janjić, Bojan and Vlahović, Zoran and Glišić, Mirko",
year = "2016",
abstract = "Background/Aim. During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and temperature of irrigans on thermal changes of the local bone during drilling implant sites, and to test the influence of irrigans temperature on the temperature of surgical drill guide. Methods. A total of 48 specimens obtained from bovine ribs were randomly allocated to four experimental conditions according to the 2 x 2 factorial design: drill guide (with or without) and saline (at 25°C or 5°C). Real-time infrared thermography was used as a method for temperature measurement. The primary outcome was bone temperature change during drilling implant sites measured at 3 osteotomy depths, whereas the second one was change in the temperature of the drill guide. Data were analyzed by Brunner and Langer nonparametric analysis and Wilcoxon test. Results. The effect of drill guide on the changes of bone temperature was significant at the entrance of osteotomy, whereas the effect of saline temperature was significant at all osteotomy levels (p  lt  0.001). No significant interaction was found (p > 0.05). Guided surgery and irrigation with saline at 25°C were associated with the highest bone temperature increase. Increase in drill guide temperature was significantly higher when saline at 25°C was used (p  lt  0.001). Conclusion. Guided implant site preparation generates higher temperature of the local bone than conventional drilling, not exceeding the threshold for thermal bone necrosis. Although saline at room temperature provides sufficient heat control during drilling, cooled saline is more effective regardless the use of surgical drill guide., Uvod/Cilj. Tokom preparacije ležišta za implantat mehanička energija pretvara se u toplotnu, što dovodi do prolaznog povišenja temperature okolne kosti. Temperatura od 47°C tokom više od jednog minuta narušava oseointegraciju, mehaničke osobine lokalne kosti i može dovesti do ranog neuspeha implantata. Cilj ove in vitro studije bio je da se ispita uticaj hirurškog stenta i temperature irigansa na termičke promene u kosti tokom preparacije ležišta za implantat, kao i uticaj temperature irigansa na temperaturu hirurškog stenta. Metode. Ukupno 48 uzoraka dobijenih od goveđih rebara bilo je podeljeno metodom slučajnog izbora u četiri grupe prema 2 x 2 faktorskom dizajnu: prisustvo hirurškog stenta (da/ne) i temperatura fiziološkog rastvora (25°C/5°C). Temperatura je merena infracrvenom termografijom u realnom vremenu. Primarni ishod bio je promena temperature kosti tokom preparacije ležišta implantata merena na tri dubine ležišta, a sekundarni ishod promena temperature hirurškog stenta. Podaci su analizirani Bruner-Langer neparametrijskom analizom i Vilkoksonovim testom. Rezultati. Uticaj hirurškog stenta na promenutemperature kosti bio je značajan na ulazu u ležište za implantat, dok je uticaj temperature irigansa bio značajan na svim dubinama ležišta (p  lt  0,001). Međusobni uticaj ispitivanih faktora nije bio značajan (p > 0,05). Upotreba hirurškog stenta i ispiranje fiziološkim rastvorom temperature 25°C bili su praćeni najvišim porastom temperature kosti. Porast temperature hirurškog stenta bio je značajno viši kada je korišćeno ispiranje na temperaturi od 25°C (p  lt  0,001). Zaključak. Tokom kontrolisane preparacije ležišta za implantat došlo je do većeg zagrevanja kosti u poređenju sa standardnom preparacijom, ne premašujući temperaturu kritičnu za termičku nekrozu kosti. Iako ispiranje na sobnoj temperaturi obezbeđuje dovoljno hlađenja kosti tokom preparacije ležišta za implantat, ohlađeni rastvor za ispiranje je efikasniji bez obzira na primenu hirurškog stenta.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites: Thermographic analysis on bovine ribs, Uticaj hirurškog stenta i temperature irigansa na termičke promene u kosti tokom preparacije ležišta implantata - termografska analiza na goveđim rebrima",
volume = "73",
number = "8",
pages = "744-750",
doi = "10.2298/VSP141208041M"
}
Marković, A., Lazić, Z., Mišić, T., Šćepanović, M., Todorović, A., Thakare, K., Janjić, B., Vlahović, Z.,& Glišić, M.. (2016). Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites: Thermographic analysis on bovine ribs. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 73(8), 744-750.
https://doi.org/10.2298/VSP141208041M
Marković A, Lazić Z, Mišić T, Šćepanović M, Todorović A, Thakare K, Janjić B, Vlahović Z, Glišić M. Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites: Thermographic analysis on bovine ribs. in Vojnosanitetski pregled. 2016;73(8):744-750.
doi:10.2298/VSP141208041M .
Marković, Aleksa, Lazić, Zoran, Mišić, Tijana, Šćepanović, Miodrag, Todorović, Aleksandar, Thakare, Kaustubh, Janjić, Bojan, Vlahović, Zoran, Glišić, Mirko, "Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites: Thermographic analysis on bovine ribs" in Vojnosanitetski pregled, 73, no. 8 (2016):744-750,
https://doi.org/10.2298/VSP141208041M . .
22
8
22

Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs

Vlahović, Zoran; Marković, Aleksa; Golubović, Mileta; Šćepanović, Miodrag; Kalanović, Milena; Đinić, Ana

(Wiley, Hoboken, 2015)

TY  - JOUR
AU  - Vlahović, Zoran
AU  - Marković, Aleksa
AU  - Golubović, Mileta
AU  - Šćepanović, Miodrag
AU  - Kalanović, Milena
AU  - Đinić, Ana
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2016
AB  - AimThe aim of this study was comparing the effect of flapless vs. flap technique of implant placement on inflammation degree of peri-implant soft tissue, through histopathological analysis. MethodThe experiment was conducted on five domestic pigs. Nine weeks after tooth extraction, implants were installed. Each animal received six implants in mandible. According to split-mouth design, randomly one side was used for flapless technique using mini-incision, while on the other side, flap was raised. After 7, 14, 21, 28, and 90days, the experimental animals were sacrificed. Samples for histopathological analyzes were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The degree of inflammatory response in the peri-implant soft tissue was estimated through ordinal scores from 0 to 3. ResultsIn the flap group Score 3 indicating high degree of inflammation was present from day 7 to day 21, in contrast to flapless group where Score 3 was not recorded during the entire follow-up. Three months after implantation, there were no signs of inflammation neither around flap nor around flapless implants. ConclusionFlapless surgical implantation technique using mini-incision decreases peri-implant soft tissue inflammatory reaction compared with flap surgery.
PB  - Wiley, Hoboken
T2  - Clinical Oral Implants Research
T1  - Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs
VL  - 26
IS  - 11
SP  - 1309
EP  - 1314
DO  - 10.1111/clr.12456
ER  - 
@article{
author = "Vlahović, Zoran and Marković, Aleksa and Golubović, Mileta and Šćepanović, Miodrag and Kalanović, Milena and Đinić, Ana",
year = "2015",
abstract = "AimThe aim of this study was comparing the effect of flapless vs. flap technique of implant placement on inflammation degree of peri-implant soft tissue, through histopathological analysis. MethodThe experiment was conducted on five domestic pigs. Nine weeks after tooth extraction, implants were installed. Each animal received six implants in mandible. According to split-mouth design, randomly one side was used for flapless technique using mini-incision, while on the other side, flap was raised. After 7, 14, 21, 28, and 90days, the experimental animals were sacrificed. Samples for histopathological analyzes were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The degree of inflammatory response in the peri-implant soft tissue was estimated through ordinal scores from 0 to 3. ResultsIn the flap group Score 3 indicating high degree of inflammation was present from day 7 to day 21, in contrast to flapless group where Score 3 was not recorded during the entire follow-up. Three months after implantation, there were no signs of inflammation neither around flap nor around flapless implants. ConclusionFlapless surgical implantation technique using mini-incision decreases peri-implant soft tissue inflammatory reaction compared with flap surgery.",
publisher = "Wiley, Hoboken",
journal = "Clinical Oral Implants Research",
title = "Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs",
volume = "26",
number = "11",
pages = "1309-1314",
doi = "10.1111/clr.12456"
}
Vlahović, Z., Marković, A., Golubović, M., Šćepanović, M., Kalanović, M.,& Đinić, A.. (2015). Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs. in Clinical Oral Implants Research
Wiley, Hoboken., 26(11), 1309-1314.
https://doi.org/10.1111/clr.12456
Vlahović Z, Marković A, Golubović M, Šćepanović M, Kalanović M, Đinić A. Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs. in Clinical Oral Implants Research. 2015;26(11):1309-1314.
doi:10.1111/clr.12456 .
Vlahović, Zoran, Marković, Aleksa, Golubović, Mileta, Šćepanović, Miodrag, Kalanović, Milena, Đinić, Ana, "Histopathological comparative analysis of peri-implant soft tissue response after dental implant placement with flap and flapless surgical technique. Experimental study in pigs" in Clinical Oral Implants Research, 26, no. 11 (2015):1309-1314,
https://doi.org/10.1111/clr.12456 . .
1
7
5
5

A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla

Marković, Aleksa; Čolić, Snježana; Šćepanović, Miodrag; Mišić, Tijana; Đinić, Ana; Bhusal, Dinesh Sharma

(Wiley-Blackwell, Hoboken, 2015)

TY  - JOUR
AU  - Marković, Aleksa
AU  - Čolić, Snježana
AU  - Šćepanović, Miodrag
AU  - Mišić, Tijana
AU  - Đinić, Ana
AU  - Bhusal, Dinesh Sharma
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2014
AB  - PurposesThe primary aim of the study was to investigate a 1-year success rate of early-loaded bone level implants with a chemically modified sand-blasted, large grit, acid-etched surface (SLActive (R), Institut Straumann AG, Basel, Switzerland) in the posterior maxilla. Secondary objectives included stability of these implants and peri-implant bone level. Materials and MethodsBone level (R) implants (Institut Straumann AG) inserted into premolar and/or molar maxillary sites were loaded after 6 weeks of healing. The implants were monitored for 1 year using the following outcome measures: implant success, primary and secondary stability, and peri-implant bone level. ResultsOut of 37 implants placed in 13 patients, 36 reached sufficient stability and were early loaded, whereas one underwent a delayed loading protocol. One-year success rate of early-loaded implants was 100%. Implant stability at baseline was 71.75. 6 to be steadily increased thereafter up to 1 year (80.3 +/- 3.3), except at 2 weeks when a nonsignificant decrease was noticed (71.9 +/- 3.9). Continuous and significant bone loss was observed, reaching 0.4 +/- 0.1mm in the first postoperative year. ConclusionBone level implants with the SLActive surface placed into low-density bone and loaded after 6 weeks of healing can predictably achieve and maintain a successful tissue integration.
PB  - Wiley-Blackwell, Hoboken
T2  - Clinical Implant Dentistry & Related Research
T1  - A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla
VL  - 17
IS  - 5
SP  - 1004
EP  - 1013
DO  - 10.1111/cid.12201
ER  - 
@article{
author = "Marković, Aleksa and Čolić, Snježana and Šćepanović, Miodrag and Mišić, Tijana and Đinić, Ana and Bhusal, Dinesh Sharma",
year = "2015",
abstract = "PurposesThe primary aim of the study was to investigate a 1-year success rate of early-loaded bone level implants with a chemically modified sand-blasted, large grit, acid-etched surface (SLActive (R), Institut Straumann AG, Basel, Switzerland) in the posterior maxilla. Secondary objectives included stability of these implants and peri-implant bone level. Materials and MethodsBone level (R) implants (Institut Straumann AG) inserted into premolar and/or molar maxillary sites were loaded after 6 weeks of healing. The implants were monitored for 1 year using the following outcome measures: implant success, primary and secondary stability, and peri-implant bone level. ResultsOut of 37 implants placed in 13 patients, 36 reached sufficient stability and were early loaded, whereas one underwent a delayed loading protocol. One-year success rate of early-loaded implants was 100%. Implant stability at baseline was 71.75. 6 to be steadily increased thereafter up to 1 year (80.3 +/- 3.3), except at 2 weeks when a nonsignificant decrease was noticed (71.9 +/- 3.9). Continuous and significant bone loss was observed, reaching 0.4 +/- 0.1mm in the first postoperative year. ConclusionBone level implants with the SLActive surface placed into low-density bone and loaded after 6 weeks of healing can predictably achieve and maintain a successful tissue integration.",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Clinical Implant Dentistry & Related Research",
title = "A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla",
volume = "17",
number = "5",
pages = "1004-1013",
doi = "10.1111/cid.12201"
}
Marković, A., Čolić, S., Šćepanović, M., Mišić, T., Đinić, A.,& Bhusal, D. S.. (2015). A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla. in Clinical Implant Dentistry & Related Research
Wiley-Blackwell, Hoboken., 17(5), 1004-1013.
https://doi.org/10.1111/cid.12201
Marković A, Čolić S, Šćepanović M, Mišić T, Đinić A, Bhusal DS. A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla. in Clinical Implant Dentistry & Related Research. 2015;17(5):1004-1013.
doi:10.1111/cid.12201 .
Marković, Aleksa, Čolić, Snježana, Šćepanović, Miodrag, Mišić, Tijana, Đinić, Ana, Bhusal, Dinesh Sharma, "A 1-Year Prospective Clinical and Radiographic Study of Early-Loaded Bone Level Implants in the Posterior Maxilla" in Clinical Implant Dentistry & Related Research, 17, no. 5 (2015):1004-1013,
https://doi.org/10.1111/cid.12201 . .
13
15
14

Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level

Šćepanović, Miodrag; Todorović, Aleksandar; Marković, Aleksa; Patrnogić, Vesna; Miličić, Biljana; Moufti, Adel M.; Mišić, Tijana

(Elsevier Gmbh, Urban & Fischer Verlag, Jena, 2015)

TY  - JOUR
AU  - Šćepanović, Miodrag
AU  - Todorović, Aleksandar
AU  - Marković, Aleksa
AU  - Patrnogić, Vesna
AU  - Miličić, Biljana
AU  - Moufti, Adel M.
AU  - Mišić, Tijana
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2048
AB  - Aim: This 1-year cohort study investigated stability and pen-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Materials and methods: Each of 30 edentulous patients received 4 mini dental implants (1.8 mm x 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic (R) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The pen-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. Results: The primary stability (Periotest value, PTV) measured -0.27 +/- 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 +/- 7.05) then increased significantly reaching (PTV = 6.17 +/- 6.15) at 12 months. The mean PIBL measured 0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Conclusions: Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants.
PB  - Elsevier Gmbh, Urban & Fischer Verlag, Jena
T2  - Annals of Anatomy - Anatomischer Anzeiger
T1  - Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level
VL  - 199
SP  - 85
EP  - 91
DO  - 10.1016/j.aanat.2013.12.005
ER  - 
@article{
author = "Šćepanović, Miodrag and Todorović, Aleksandar and Marković, Aleksa and Patrnogić, Vesna and Miličić, Biljana and Moufti, Adel M. and Mišić, Tijana",
year = "2015",
abstract = "Aim: This 1-year cohort study investigated stability and pen-implant marginal bone level of immediately loaded mini dental implants used to retain overdentures. Materials and methods: Each of 30 edentulous patients received 4 mini dental implants (1.8 mm x 13 mm) in the interforaminal mandibular region. The implants were immediately loaded with pre-made overdentures. Outcome measures included implant stability and bone resorption. Implant stability was measured using the Periotest Classic (R) device immediately after placement and on the 3rd and 6th weeks and the 4th, 6th and 12th months postoperatively. The pen-implant marginal bone level (PIBL) was evaluated at the implant's mesial and distal sides from the polished platform to the marginal crest. Radiographs were taken using a tailored film holder to reproducibly position the X-ray tube at the 6th week, 4th and 12th months postoperatively. Results: The primary stability (Periotest value, PTV) measured -0.27 +/- 3.41 on a scale of -8 to + 50 (lower PTV reflects higher stability). The secondary stability decreased significantly until week 6 (mean PTV = 7.61 +/- 7.05) then increased significantly reaching (PTV = 6.17 +/- 6.15) at 12 months. The mean PIBL measured 0.40 mm after 1 year of functional loading, with no statistically significant differences at the various follow-ups (p = 0.218). Conclusions: Mini dental implants placed into the interforaminal region could achieve a favorable primary stability for immediate loading. The follow-up Periotest values fluctuated, apparently reflecting the dynamics of bone remodeling, with the implants remaining clinically stable (98.3%) after 1 year of function. The 1-year bone resorption around immediately loaded MDIs is within the clinically acceptable range for standard implants.",
publisher = "Elsevier Gmbh, Urban & Fischer Verlag, Jena",
journal = "Annals of Anatomy - Anatomischer Anzeiger",
title = "Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level",
volume = "199",
pages = "85-91",
doi = "10.1016/j.aanat.2013.12.005"
}
Šćepanović, M., Todorović, A., Marković, A., Patrnogić, V., Miličić, B., Moufti, A. M.,& Mišić, T.. (2015). Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level. in Annals of Anatomy - Anatomischer Anzeiger
Elsevier Gmbh, Urban & Fischer Verlag, Jena., 199, 85-91.
https://doi.org/10.1016/j.aanat.2013.12.005
Šćepanović M, Todorović A, Marković A, Patrnogić V, Miličić B, Moufti AM, Mišić T. Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level. in Annals of Anatomy - Anatomischer Anzeiger. 2015;199:85-91.
doi:10.1016/j.aanat.2013.12.005 .
Šćepanović, Miodrag, Todorović, Aleksandar, Marković, Aleksa, Patrnogić, Vesna, Miličić, Biljana, Moufti, Adel M., Mišić, Tijana, "Immediately loaded mini dental implants as overdenture retainers: 1-Year cohort study of implant stability and peri-implant marginal bone level" in Annals of Anatomy - Anatomischer Anzeiger, 199 (2015):85-91,
https://doi.org/10.1016/j.aanat.2013.12.005 . .
22
18
26

Immunohistochemical analysis of blood vessels in peri-implant mucosa: a comparison between mini-incision flapless and flap surgeries in domestic pigs

Lazić, Zoran; Golubović, Mileta; Marković, Aleksa; Šćepanović, Miodrag; Mišić, Tijana; Vlahović, Zoran

(Wiley-Blackwell, Hoboken, 2015)

TY  - JOUR
AU  - Lazić, Zoran
AU  - Golubović, Mileta
AU  - Marković, Aleksa
AU  - Šćepanović, Miodrag
AU  - Mišić, Tijana
AU  - Vlahović, Zoran
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1964
AB  - AimThe aim of this experimental study is to compare the effect of mini-incision flapless versus flap technique of implant placement on the amount of vascular structures and blood vessel elements in peri-implant soft tissue, using immunohistochemical analysis. MethodThe experiment was conducted on five domestic pigs. Each animal received six implants in mandible according to the split-mouth design. On one randomly chosen jaw side, mini-incision flapless surgery was performed, whereas on the opposite jaw side, flap was raised. After 3months of implant healing through submerged approach, the experimental animals were sacrificed and samples for immunohistochemical analyses were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The study outcome was the presence of vascular structures and elements of the blood vessels in the peri-implant mucosa per microscopic field, estimated through ordinal scores from 0 to 2. Effects of surgical approach, site of implantation, and their interaction on vascular scores of peri-implant mucosa were assessed by Brunner and Langer nonparametric analysis of longitudinal data. ResultsStatistically significant effect of surgical approach on vascularity of peri-implant mucosa has been revealed in the second mucosal layer, where flapless approach provided higher vascularity compared with flap approach (P=0.002). In the remaining two layers, surgical approach did not affect mucosal vascularity significantly (layer 1: P=0.071; layer 3: P=0.433). ConclusionThe flapless surgical implant placement approach using mini-incision provides better vascularization of peri-implant mucosa after 3months of healing compared with flap surgery.
PB  - Wiley-Blackwell, Hoboken
T2  - Clinical Oral Implants Research
T1  - Immunohistochemical analysis of blood vessels in peri-implant mucosa: a comparison between mini-incision flapless and flap surgeries in domestic pigs
VL  - 26
IS  - 7
SP  - 775
EP  - 779
DO  - 10.1111/clr.12337
ER  - 
@article{
author = "Lazić, Zoran and Golubović, Mileta and Marković, Aleksa and Šćepanović, Miodrag and Mišić, Tijana and Vlahović, Zoran",
year = "2015",
abstract = "AimThe aim of this experimental study is to compare the effect of mini-incision flapless versus flap technique of implant placement on the amount of vascular structures and blood vessel elements in peri-implant soft tissue, using immunohistochemical analysis. MethodThe experiment was conducted on five domestic pigs. Each animal received six implants in mandible according to the split-mouth design. On one randomly chosen jaw side, mini-incision flapless surgery was performed, whereas on the opposite jaw side, flap was raised. After 3months of implant healing through submerged approach, the experimental animals were sacrificed and samples for immunohistochemical analyses were taken from the buccal side of peri-implant mucosa next to the neck of implants, from three levels. The study outcome was the presence of vascular structures and elements of the blood vessels in the peri-implant mucosa per microscopic field, estimated through ordinal scores from 0 to 2. Effects of surgical approach, site of implantation, and their interaction on vascular scores of peri-implant mucosa were assessed by Brunner and Langer nonparametric analysis of longitudinal data. ResultsStatistically significant effect of surgical approach on vascularity of peri-implant mucosa has been revealed in the second mucosal layer, where flapless approach provided higher vascularity compared with flap approach (P=0.002). In the remaining two layers, surgical approach did not affect mucosal vascularity significantly (layer 1: P=0.071; layer 3: P=0.433). ConclusionThe flapless surgical implant placement approach using mini-incision provides better vascularization of peri-implant mucosa after 3months of healing compared with flap surgery.",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Clinical Oral Implants Research",
title = "Immunohistochemical analysis of blood vessels in peri-implant mucosa: a comparison between mini-incision flapless and flap surgeries in domestic pigs",
volume = "26",
number = "7",
pages = "775-779",
doi = "10.1111/clr.12337"
}
Lazić, Z., Golubović, M., Marković, A., Šćepanović, M., Mišić, T.,& Vlahović, Z.. (2015). Immunohistochemical analysis of blood vessels in peri-implant mucosa: a comparison between mini-incision flapless and flap surgeries in domestic pigs. in Clinical Oral Implants Research
Wiley-Blackwell, Hoboken., 26(7), 775-779.
https://doi.org/10.1111/clr.12337
Lazić Z, Golubović M, Marković A, Šćepanović M, Mišić T, Vlahović Z. Immunohistochemical analysis of blood vessels in peri-implant mucosa: a comparison between mini-incision flapless and flap surgeries in domestic pigs. in Clinical Oral Implants Research. 2015;26(7):775-779.
doi:10.1111/clr.12337 .
Lazić, Zoran, Golubović, Mileta, Marković, Aleksa, Šćepanović, Miodrag, Mišić, Tijana, Vlahović, Zoran, "Immunohistochemical analysis of blood vessels in peri-implant mucosa: a comparison between mini-incision flapless and flap surgeries in domestic pigs" in Clinical Oral Implants Research, 26, no. 7 (2015):775-779,
https://doi.org/10.1111/clr.12337 . .
10
6
11

Real-time thermographic analysis of low-density bone during implant placement: a randomized parallel-group clinical study comparing lateral condensation with bone drilling surgical technique

Marković, Aleksa; Mišić, Tijana; Mancić, Dragan; Jovanović, Igor; Šćepanović, Miodrag; Jezdić, Zoran

(Wiley, Hoboken, 2014)

TY  - JOUR
AU  - Marković, Aleksa
AU  - Mišić, Tijana
AU  - Mancić, Dragan
AU  - Jovanović, Igor
AU  - Šćepanović, Miodrag
AU  - Jezdić, Zoran
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1877
AB  - Objectives: To compare the effect of two surgical techniques, lateral condensation and bone drilling, on changes in temperature of the adjacent low-density bone during implant placement into posterior maxilla and to investigate the influence of the host factors - age, gender, region of implantation, bone density, and thickness of the cortical bone at the recipient sites. Material and methods: Local bone temperature was measured thermographically during implant placement into posterior maxilla following lateral bone condensing (test group) or bone drilling (controls). The main study outcomes were baseline bone temperature prior to implantation and maximum bone temperature recorded during implantation. Early implant success was evaluated after 6 months of healing. Results: A total of 40 implants were randomly allocated to test and control groups and placed into maxillary premolar and/or molar region of 18 participants of both genders and average age of 51.74 years. All recorded bone temperatures were below the threshold for thermal necrosis. Although both groups showed significant increase in bone temperature during implant placement procedure (P  lt = 0.0005), it was significantly higher for bone condensing compared with drilling (P  lt = 0.0005; 3.79 +/- 1.54 degrees C; 1.91 +/- 0.70 degrees C respectively). No host factor was singled out as a significant predictor of bone temperature changes, although trend of higher increase was observed in young patients, regardless of gender, during implant placement procedure into maxillary first premolar region with bone density type 3 and cortical layer thicker than 1 mm. Early implant success rate after 6 months follow-up was 100%. Conclusion: Although both surgical techniques, bone condensing and bone drilling, can be considered safe regarding their thermal effect on the bone of posterior maxilla, bone drilling is associated with fewer local bone heating during implantation. Host factors do not affect the bone thermal changes significantly.
PB  - Wiley, Hoboken
T2  - Clinical Oral Implants Research
T1  - Real-time thermographic analysis of low-density bone during implant placement: a randomized parallel-group clinical study comparing lateral condensation with bone drilling surgical technique
VL  - 25
IS  - 8
SP  - 910
EP  - 918
DO  - 10.1111/clr.12191
ER  - 
@article{
author = "Marković, Aleksa and Mišić, Tijana and Mancić, Dragan and Jovanović, Igor and Šćepanović, Miodrag and Jezdić, Zoran",
year = "2014",
abstract = "Objectives: To compare the effect of two surgical techniques, lateral condensation and bone drilling, on changes in temperature of the adjacent low-density bone during implant placement into posterior maxilla and to investigate the influence of the host factors - age, gender, region of implantation, bone density, and thickness of the cortical bone at the recipient sites. Material and methods: Local bone temperature was measured thermographically during implant placement into posterior maxilla following lateral bone condensing (test group) or bone drilling (controls). The main study outcomes were baseline bone temperature prior to implantation and maximum bone temperature recorded during implantation. Early implant success was evaluated after 6 months of healing. Results: A total of 40 implants were randomly allocated to test and control groups and placed into maxillary premolar and/or molar region of 18 participants of both genders and average age of 51.74 years. All recorded bone temperatures were below the threshold for thermal necrosis. Although both groups showed significant increase in bone temperature during implant placement procedure (P  lt = 0.0005), it was significantly higher for bone condensing compared with drilling (P  lt = 0.0005; 3.79 +/- 1.54 degrees C; 1.91 +/- 0.70 degrees C respectively). No host factor was singled out as a significant predictor of bone temperature changes, although trend of higher increase was observed in young patients, regardless of gender, during implant placement procedure into maxillary first premolar region with bone density type 3 and cortical layer thicker than 1 mm. Early implant success rate after 6 months follow-up was 100%. Conclusion: Although both surgical techniques, bone condensing and bone drilling, can be considered safe regarding their thermal effect on the bone of posterior maxilla, bone drilling is associated with fewer local bone heating during implantation. Host factors do not affect the bone thermal changes significantly.",
publisher = "Wiley, Hoboken",
journal = "Clinical Oral Implants Research",
title = "Real-time thermographic analysis of low-density bone during implant placement: a randomized parallel-group clinical study comparing lateral condensation with bone drilling surgical technique",
volume = "25",
number = "8",
pages = "910-918",
doi = "10.1111/clr.12191"
}
Marković, A., Mišić, T., Mancić, D., Jovanović, I., Šćepanović, M.,& Jezdić, Z.. (2014). Real-time thermographic analysis of low-density bone during implant placement: a randomized parallel-group clinical study comparing lateral condensation with bone drilling surgical technique. in Clinical Oral Implants Research
Wiley, Hoboken., 25(8), 910-918.
https://doi.org/10.1111/clr.12191
Marković A, Mišić T, Mancić D, Jovanović I, Šćepanović M, Jezdić Z. Real-time thermographic analysis of low-density bone during implant placement: a randomized parallel-group clinical study comparing lateral condensation with bone drilling surgical technique. in Clinical Oral Implants Research. 2014;25(8):910-918.
doi:10.1111/clr.12191 .
Marković, Aleksa, Mišić, Tijana, Mancić, Dragan, Jovanović, Igor, Šćepanović, Miodrag, Jezdić, Zoran, "Real-time thermographic analysis of low-density bone during implant placement: a randomized parallel-group clinical study comparing lateral condensation with bone drilling surgical technique" in Clinical Oral Implants Research, 25, no. 8 (2014):910-918,
https://doi.org/10.1111/clr.12191 . .
11
11
15

Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements

Patrnogić, Vesna; Todorović, Aleksandar; Šćepanović, Miodrag; Radović, Katarina; Vesnić, Jelena; Grbović, Aleksandar

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2013)

TY  - JOUR
AU  - Patrnogić, Vesna
AU  - Todorović, Aleksandar
AU  - Šćepanović, Miodrag
AU  - Radović, Katarina
AU  - Vesnić, Jelena
AU  - Grbović, Aleksandar
PY  - 2013
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1812
AB  - Background/Aim. Different types of dental restorations are used for the therapy of unilateral free-end saddle edentulism. Unilateral complex partial denture is one of the indications for the Kennedy class II partial edentulism. The abscence of major connector and denture plate is an advantage compared to the conventional restorations, because of better comfort and shorter period of adaptation. The aim of the study was to analyse the influence of free-end saddle length change on the behaviour of unilateral complex partial denture supporting structures. Methods. Stress levels of the canine and the first premolar as retentional teeth and the attachments were tested under the influence of physiological forces with the loading point shifting distally in relation to the saddle length change. A virtual real size 3D model of the fixed part of the restoration (the canine and the first premolar with milled crowns) was created using the CATIA computer program. It was connected to the mobile part of partial denture with the SD snap in latch attachment. Mobile part of the restoration was designed in the region of 2, 3 and 4 lateral teeth (second premolar, first, second and third molar). By using the finite element method (FEM) stress levels analysis was performed under the load of physiological forces of 150 N in the free-end saddle teeth zone. Results. The results of analysis show that physiological forces cause a different stress distribution on the abutment teeth and the attachment, depending on the saddle length. Conclusion. The stress level values obtained for the abutment teeth as well as the attachment are far lower than the marginal ones. The behaviour of the system changes under this defined stress, but no plastic deformation occurs.
AB  - Uvod/Cilj. U terapiji jednostrano slobodnog sedla koriste se različiti oblici zubnih nadoknada. Jednostrana kompleksna parcijalna proteza (JKPP) jedna je od indikacija za bezubost klase Kenedi II. Odsustvo velike spojnice i protezne ploče predstavlja prednost u odnosu na konvencionalne nadoknade zbog boljeg komfora i kraćeg perioda adaptacije. Cilj rada bio je analiza uticaja promene dužine slobodnog sedla na ponašanje potpornih struktura JKPP. Metode. Ispitivani su naponi očnjaka i prvog premolara kao retencionih zuba i veze (spoja) pod dejstvom fizioloških sila sa pomeranjem tačke opterećenja distalno, u zavisnosti od dužine sedla. Primenom kompjuterskog programa CATIA u realnoj veličini urađen je virtulni 3D model fiksnog dela nadoknade (očnjak i prvi premolar sa namenskim krunama) koji je veza SD snap in latch priključena na mobilni deo parcijalne proteze. Mobilni deo nadoknade postavljen je u predelu dva, tri, odnosno četiri bočna zuba (drugi premolar, prvi, drugi i treći molar). Primenom metode konačnih elemenata obavljena je analiza naponskih stanja pri opterećenju fiziološkim silama od 150 N u predelu zuba slobodnog sedla. Rezultati. Analiza proračuna pokazala je da pod dejstvom fizioloških sila dolazi do različite raspodele napona na retencione zube i spoj u zavisnosti od dužine sedla. Zaključak. Dobijene vrednosti za napone kako na retencionim zubima, tako i na spoju, daleko su manje od graničnih. Pri zadatim naponima dolazi do promene ponašanja, ali ne i do plastične deformacije sistema.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements
T1  - Uticaj promene dužine slobodnog sedla na promenu napona retencionih zuba i spoja jednostrane kompleksne parcijalne proteze
VL  - 70
IS  - 11
SP  - 1015
EP  - 1022
DO  - 10.2298/VSP110603028P
ER  - 
@article{
author = "Patrnogić, Vesna and Todorović, Aleksandar and Šćepanović, Miodrag and Radović, Katarina and Vesnić, Jelena and Grbović, Aleksandar",
year = "2013",
abstract = "Background/Aim. Different types of dental restorations are used for the therapy of unilateral free-end saddle edentulism. Unilateral complex partial denture is one of the indications for the Kennedy class II partial edentulism. The abscence of major connector and denture plate is an advantage compared to the conventional restorations, because of better comfort and shorter period of adaptation. The aim of the study was to analyse the influence of free-end saddle length change on the behaviour of unilateral complex partial denture supporting structures. Methods. Stress levels of the canine and the first premolar as retentional teeth and the attachments were tested under the influence of physiological forces with the loading point shifting distally in relation to the saddle length change. A virtual real size 3D model of the fixed part of the restoration (the canine and the first premolar with milled crowns) was created using the CATIA computer program. It was connected to the mobile part of partial denture with the SD snap in latch attachment. Mobile part of the restoration was designed in the region of 2, 3 and 4 lateral teeth (second premolar, first, second and third molar). By using the finite element method (FEM) stress levels analysis was performed under the load of physiological forces of 150 N in the free-end saddle teeth zone. Results. The results of analysis show that physiological forces cause a different stress distribution on the abutment teeth and the attachment, depending on the saddle length. Conclusion. The stress level values obtained for the abutment teeth as well as the attachment are far lower than the marginal ones. The behaviour of the system changes under this defined stress, but no plastic deformation occurs., Uvod/Cilj. U terapiji jednostrano slobodnog sedla koriste se različiti oblici zubnih nadoknada. Jednostrana kompleksna parcijalna proteza (JKPP) jedna je od indikacija za bezubost klase Kenedi II. Odsustvo velike spojnice i protezne ploče predstavlja prednost u odnosu na konvencionalne nadoknade zbog boljeg komfora i kraćeg perioda adaptacije. Cilj rada bio je analiza uticaja promene dužine slobodnog sedla na ponašanje potpornih struktura JKPP. Metode. Ispitivani su naponi očnjaka i prvog premolara kao retencionih zuba i veze (spoja) pod dejstvom fizioloških sila sa pomeranjem tačke opterećenja distalno, u zavisnosti od dužine sedla. Primenom kompjuterskog programa CATIA u realnoj veličini urađen je virtulni 3D model fiksnog dela nadoknade (očnjak i prvi premolar sa namenskim krunama) koji je veza SD snap in latch priključena na mobilni deo parcijalne proteze. Mobilni deo nadoknade postavljen je u predelu dva, tri, odnosno četiri bočna zuba (drugi premolar, prvi, drugi i treći molar). Primenom metode konačnih elemenata obavljena je analiza naponskih stanja pri opterećenju fiziološkim silama od 150 N u predelu zuba slobodnog sedla. Rezultati. Analiza proračuna pokazala je da pod dejstvom fizioloških sila dolazi do različite raspodele napona na retencione zube i spoj u zavisnosti od dužine sedla. Zaključak. Dobijene vrednosti za napone kako na retencionim zubima, tako i na spoju, daleko su manje od graničnih. Pri zadatim naponima dolazi do promene ponašanja, ali ne i do plastične deformacije sistema.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements, Uticaj promene dužine slobodnog sedla na promenu napona retencionih zuba i spoja jednostrane kompleksne parcijalne proteze",
volume = "70",
number = "11",
pages = "1015-1022",
doi = "10.2298/VSP110603028P"
}
Patrnogić, V., Todorović, A., Šćepanović, M., Radović, K., Vesnić, J.,& Grbović, A.. (2013). Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 70(11), 1015-1022.
https://doi.org/10.2298/VSP110603028P
Patrnogić V, Todorović A, Šćepanović M, Radović K, Vesnić J, Grbović A. Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements. in Vojnosanitetski pregled. 2013;70(11):1015-1022.
doi:10.2298/VSP110603028P .
Patrnogić, Vesna, Todorović, Aleksandar, Šćepanović, Miodrag, Radović, Katarina, Vesnić, Jelena, Grbović, Aleksandar, "Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements" in Vojnosanitetski pregled, 70, no. 11 (2013):1015-1022,
https://doi.org/10.2298/VSP110603028P . .
9
4
9

Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture

Šćepanović, Miodrag; Tihaček-Šojić, Ljiljana; Tasić, Milan; Mitrović, Radivoje; Todorović, Aleksandar; Trifković, Branka

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2013)

TY  - JOUR
AU  - Šćepanović, Miodrag
AU  - Tihaček-Šojić, Ljiljana
AU  - Tasić, Milan
AU  - Mitrović, Radivoje
AU  - Todorović, Aleksandar
AU  - Trifković, Branka
PY  - 2013
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1783
AB  - Bacground/Aim. Retentive force of removable partial denture (RPD) directly depends on elastic force of stretched retentive clasp arms (RCAs). During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs. This study was based on analyzing properties of clasps designed by conventional clasp wax profiles and defining the optimal shapes of RCAs for stress distribution and safety factor aspects. Methods. Computer-aided-design (CAD) models of RCAs with simulated properties of materials used for fabrication of RPD cobalt-chromium-molybdenum (CoCrMo) alloy, commercially pure titanium (CPTi) and polyacetale were analyzed. Results. The research showed that geometrics of Rapidflex profiles from the BIOS concept are defined for designing and modeling RCAs from CoCrMo alloys. I-Bar and Bonihard clasps made from CPTi might have the same design as Co- CrMo clasp only by safety factor aspect, but it is obvious that CPTi are much more flexible, so their shape must be more massive. Polyacetale clasps should not be fabricated by BIOS concept for CoCrMo alloy. A proof for that is the low value of safety factor. Conclusion. The BIOS concept should be used only for RCAs made of CoCrMo alloy and different wax profiles should be used for fabricating clasps of other investigated materials. The contribution of this study may be the improvement of present systems for defining the clasps shapes made from CoCrMo alloys. The more significant application is the possibility of creating new concepts in defining shapes of RCA made from CPTi and polyacetale.
AB  - Uvod/Cilj. Retenciona sila parcijalne skeletirane proteze (PSP) direktno zavisi od elastične sile rastegnute kukice. Da bi uspešno obavile svoju ulogu, retencione ručice kukice (RRK) prilikom defleksije moraju imati što ravnomerniju raspodelu napona. Stepen sigurnosti je pojam koji se može primeniti u proceni trajnosti i funkcionalnosti RRK. Ciljevi ove studije bili su analiziranje svojstava kukica koje su urađene pomoću konvencionalnih voštanih profila za izradu RRK, kao i definisanje optimalnih oblika RRK sa aspekta raspodele napona i stepena sigurnosti. Metode. Analizirani su CAD (computer aided design) modeli RRK kojima su simulirana svojstva gradivnih materijala koji se koriste za izradu legura: CoCrMo, komercijalno čist titan (CPTi) i poliacetal. Rezultati. Rezultati su pokazali da je geometrija Rapid-flex profila, korišćenih u okviru BIOS, definisana za projektovanje i modeliranje RRK koje se izrađuju od legure (CoCrMo). I Bar i Bonihard kukice od CPTi mogu se uraditi po istom konceptu kao i legure CoCrMo sa aspekta stepena sigurnosti, međutim, titanijumske kukice bile su znatno elastičnije i stoga su morale biti masivnije. Kukice od poliacetala ne smeju se modelovati po BIOS konceptu za leguru Co-CrMo. Dokaz za to je vrlo mali stepen sigurnosti. Zaključak. BIOS koncept može da se koristiti samo za RRK koje se izrađuju od legure CoCrMo. Za izradu kukica od ostalih ispitivanih materijala neophodni su drugačiji voštani profili. Doprinos studije predstavlja i poboljšavanje postojećih sistema za definisanje oblika RRK izrađenih od legura CoCrMo. Značajnija primena rezultata je i mogućnost stvaranja novih sistema za definisanje oblika RRK od CPTi i poliacetala.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture
T1  - Definisanje optimalnog oblika i faktora sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza metodom konačnih elemenata
VL  - 70
IS  - 11
SP  - 999
EP  - 1005
DO  - 10.2298/VSP110526021S
ER  - 
@article{
author = "Šćepanović, Miodrag and Tihaček-Šojić, Ljiljana and Tasić, Milan and Mitrović, Radivoje and Todorović, Aleksandar and Trifković, Branka",
year = "2013",
abstract = "Bacground/Aim. Retentive force of removable partial denture (RPD) directly depends on elastic force of stretched retentive clasp arms (RCAs). During deflection RCA must have even stress distribution. Safety factor is the concept which can be applied in estimating durability and functionality of RCAs. This study was based on analyzing properties of clasps designed by conventional clasp wax profiles and defining the optimal shapes of RCAs for stress distribution and safety factor aspects. Methods. Computer-aided-design (CAD) models of RCAs with simulated properties of materials used for fabrication of RPD cobalt-chromium-molybdenum (CoCrMo) alloy, commercially pure titanium (CPTi) and polyacetale were analyzed. Results. The research showed that geometrics of Rapidflex profiles from the BIOS concept are defined for designing and modeling RCAs from CoCrMo alloys. I-Bar and Bonihard clasps made from CPTi might have the same design as Co- CrMo clasp only by safety factor aspect, but it is obvious that CPTi are much more flexible, so their shape must be more massive. Polyacetale clasps should not be fabricated by BIOS concept for CoCrMo alloy. A proof for that is the low value of safety factor. Conclusion. The BIOS concept should be used only for RCAs made of CoCrMo alloy and different wax profiles should be used for fabricating clasps of other investigated materials. The contribution of this study may be the improvement of present systems for defining the clasps shapes made from CoCrMo alloys. The more significant application is the possibility of creating new concepts in defining shapes of RCA made from CPTi and polyacetale., Uvod/Cilj. Retenciona sila parcijalne skeletirane proteze (PSP) direktno zavisi od elastične sile rastegnute kukice. Da bi uspešno obavile svoju ulogu, retencione ručice kukice (RRK) prilikom defleksije moraju imati što ravnomerniju raspodelu napona. Stepen sigurnosti je pojam koji se može primeniti u proceni trajnosti i funkcionalnosti RRK. Ciljevi ove studije bili su analiziranje svojstava kukica koje su urađene pomoću konvencionalnih voštanih profila za izradu RRK, kao i definisanje optimalnih oblika RRK sa aspekta raspodele napona i stepena sigurnosti. Metode. Analizirani su CAD (computer aided design) modeli RRK kojima su simulirana svojstva gradivnih materijala koji se koriste za izradu legura: CoCrMo, komercijalno čist titan (CPTi) i poliacetal. Rezultati. Rezultati su pokazali da je geometrija Rapid-flex profila, korišćenih u okviru BIOS, definisana za projektovanje i modeliranje RRK koje se izrađuju od legure (CoCrMo). I Bar i Bonihard kukice od CPTi mogu se uraditi po istom konceptu kao i legure CoCrMo sa aspekta stepena sigurnosti, međutim, titanijumske kukice bile su znatno elastičnije i stoga su morale biti masivnije. Kukice od poliacetala ne smeju se modelovati po BIOS konceptu za leguru Co-CrMo. Dokaz za to je vrlo mali stepen sigurnosti. Zaključak. BIOS koncept može da se koristiti samo za RRK koje se izrađuju od legure CoCrMo. Za izradu kukica od ostalih ispitivanih materijala neophodni su drugačiji voštani profili. Doprinos studije predstavlja i poboljšavanje postojećih sistema za definisanje oblika RRK izrađenih od legura CoCrMo. Značajnija primena rezultata je i mogućnost stvaranja novih sistema za definisanje oblika RRK od CPTi i poliacetala.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture, Definisanje optimalnog oblika i faktora sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza metodom konačnih elemenata",
volume = "70",
number = "11",
pages = "999-1005",
doi = "10.2298/VSP110526021S"
}
Šćepanović, M., Tihaček-Šojić, L., Tasić, M., Mitrović, R., Todorović, A.,& Trifković, B.. (2013). Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 70(11), 999-1005.
https://doi.org/10.2298/VSP110526021S
Šćepanović M, Tihaček-Šojić L, Tasić M, Mitrović R, Todorović A, Trifković B. Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture. in Vojnosanitetski pregled. 2013;70(11):999-1005.
doi:10.2298/VSP110526021S .
Šćepanović, Miodrag, Tihaček-Šojić, Ljiljana, Tasić, Milan, Mitrović, Radivoje, Todorović, Aleksandar, Trifković, Branka, "Finite element analysis in defining the optimal shape and safety factor of retentive clasp arms of a removable partial denture" in Vojnosanitetski pregled, 70, no. 11 (2013):999-1005,
https://doi.org/10.2298/VSP110526021S . .
3
1
4

A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants

Šćepanović, Miodrag; Luis Calvo-Guirado, Jose; Marković, Aleksa; Delgado-Ruiz, Rafael; Todorović, Aleksandar; Miličić, Biljana; Mišić, Tijana

(Quintessence Publishing Co., Ltd, 2012)

TY  - JOUR
AU  - Šćepanović, Miodrag
AU  - Luis Calvo-Guirado, Jose
AU  - Marković, Aleksa
AU  - Delgado-Ruiz, Rafael
AU  - Todorović, Aleksandar
AU  - Miličić, Biljana
AU  - Mišić, Tijana
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1687
AB  - Aim: The aim of this 1-year prospective cohort study was to evaluate the outcomes and complications of immediately loaded mini dental implants used for stabilizing mandibular overdentures in edentulous patients wearing conventional complete dentures. Materials and methods: Thirty patients received mandibular conventional complete dentures that were subsequently retained by 4 immediately loaded mini dental implants placed in the interforaminal region. Overdenture success, implant success and biological and prosthetic complications were evaluated after the first year of service. Quality of life using the Oral Heath Impact Profile (OHIP)-EDENT test, satisfaction with dental prosthesis and chewing efficiency using questionnaires and a Visual Analogue Scale (VAS) were evaluated twice: after they had received mandibular complete dentures, and again after they had received mandibular overdentures. Results: After 1 year, no overdenture failed and 2 implants did not osseointegrate, resulting in a 98.3% success rate for loaded implants and 95.9% for total implants used (3 out of 123 were not loaded due to fracture). A flap surgical approach was performed in 7 patients, 3 implants fractured during insertion, 3 overdentures fractured, occlusion balancing was necessary for 11 dentures and relining for 8. Implant rehabilitation provided significant improvement in quality of life, stability, comfort, chewing and speaking ability while no significant differences were found in quality of maintenance of hygiene and for aesthetics. Conclusions: Mini dental implant retained overdentures can be a successful therapeutic procedure for treating mandibular edentulism that improves quality of life, patient satisfaction and chewing ability in patients wearing maxillary dentures. Longer follow-ups are needed to validate this therapy in the medium and long-term.
PB  - Quintessence Publishing Co., Ltd
T2  - European Journal of Oral Implantology
T1  - A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants
VL  - 5
IS  - 4
SP  - 367
EP  - 379
UR  - https://hdl.handle.net/21.15107/rcub_smile_1687
ER  - 
@article{
author = "Šćepanović, Miodrag and Luis Calvo-Guirado, Jose and Marković, Aleksa and Delgado-Ruiz, Rafael and Todorović, Aleksandar and Miličić, Biljana and Mišić, Tijana",
year = "2012",
abstract = "Aim: The aim of this 1-year prospective cohort study was to evaluate the outcomes and complications of immediately loaded mini dental implants used for stabilizing mandibular overdentures in edentulous patients wearing conventional complete dentures. Materials and methods: Thirty patients received mandibular conventional complete dentures that were subsequently retained by 4 immediately loaded mini dental implants placed in the interforaminal region. Overdenture success, implant success and biological and prosthetic complications were evaluated after the first year of service. Quality of life using the Oral Heath Impact Profile (OHIP)-EDENT test, satisfaction with dental prosthesis and chewing efficiency using questionnaires and a Visual Analogue Scale (VAS) were evaluated twice: after they had received mandibular complete dentures, and again after they had received mandibular overdentures. Results: After 1 year, no overdenture failed and 2 implants did not osseointegrate, resulting in a 98.3% success rate for loaded implants and 95.9% for total implants used (3 out of 123 were not loaded due to fracture). A flap surgical approach was performed in 7 patients, 3 implants fractured during insertion, 3 overdentures fractured, occlusion balancing was necessary for 11 dentures and relining for 8. Implant rehabilitation provided significant improvement in quality of life, stability, comfort, chewing and speaking ability while no significant differences were found in quality of maintenance of hygiene and for aesthetics. Conclusions: Mini dental implant retained overdentures can be a successful therapeutic procedure for treating mandibular edentulism that improves quality of life, patient satisfaction and chewing ability in patients wearing maxillary dentures. Longer follow-ups are needed to validate this therapy in the medium and long-term.",
publisher = "Quintessence Publishing Co., Ltd",
journal = "European Journal of Oral Implantology",
title = "A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants",
volume = "5",
number = "4",
pages = "367-379",
url = "https://hdl.handle.net/21.15107/rcub_smile_1687"
}
Šćepanović, M., Luis Calvo-Guirado, J., Marković, A., Delgado-Ruiz, R., Todorović, A., Miličić, B.,& Mišić, T.. (2012). A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants. in European Journal of Oral Implantology
Quintessence Publishing Co., Ltd., 5(4), 367-379.
https://hdl.handle.net/21.15107/rcub_smile_1687
Šćepanović M, Luis Calvo-Guirado J, Marković A, Delgado-Ruiz R, Todorović A, Miličić B, Mišić T. A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants. in European Journal of Oral Implantology. 2012;5(4):367-379.
https://hdl.handle.net/21.15107/rcub_smile_1687 .
Šćepanović, Miodrag, Luis Calvo-Guirado, Jose, Marković, Aleksa, Delgado-Ruiz, Rafael, Todorović, Aleksandar, Miličić, Biljana, Mišić, Tijana, "A 1-year prospective cohort study on mandibular overdentures retained by mini dental implants" in European Journal of Oral Implantology, 5, no. 4 (2012):367-379,
https://hdl.handle.net/21.15107/rcub_smile_1687 .
33
33

An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling

Mišić, Tijana; Marković, Aleksa; Todorović, Aleksandar; Čolić, Snježana; Šćepanović, Miodrag; Miličić, Biljana

(Mosby-Elsevier, New York, 2011)

TY  - JOUR
AU  - Mišić, Tijana
AU  - Marković, Aleksa
AU  - Todorović, Aleksandar
AU  - Čolić, Snježana
AU  - Šćepanović, Miodrag
AU  - Miličić, Biljana
PY  - 2011
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1621
AB  - Objective. The aim of this study was to compare changes in temperature of the surrounding bone at various osteotomy depths during implant site preparation by bone condensing and by bone drilling as well as the dynamics of their change. Study design. In the present "in vitro" study, pig ribs with uniform thickness of cortical bone of 2 mm were used. Lateral bone-condensing (experimental group) and bone-drilling techniques (control group) were performed. Temperature changes were recorded at a distance of 0.5 mm from the final test osteotomy by 3 thermocouples at the depths of 1, 5, and 10 mm in tripod configuration. Data were collected from 48 measurements, 24 for each group. Results. Significantly higher mean temperature increase at the depth of 5 mm was observed during bone drilling compared with bone condensing, whereas for the depths of 1 and 10 mm differences were not significant between the 2 surgical techniques. During bone condensing, the mean temperature rise was continuously decreasing with increasing depth of osteotomies, whereas during bone drilling the mean temperature rise was first increased and reached a peak at the depth of 5 mm and then began to decrease with increasing depth of the osteotomies. Conclusions. The bone-condensing technique applied in the jaw bone class D4 offers an advantage over bone drilling because it generates a significantly smaller amount of heat. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 28-33)
PB  - Mosby-Elsevier, New York
T2  - Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology
T1  - An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling
VL  - 112
IS  - 1
SP  - 28
EP  - 33
DO  - 10.1016/j.tripleo.2010.08.010
ER  - 
@article{
author = "Mišić, Tijana and Marković, Aleksa and Todorović, Aleksandar and Čolić, Snježana and Šćepanović, Miodrag and Miličić, Biljana",
year = "2011",
abstract = "Objective. The aim of this study was to compare changes in temperature of the surrounding bone at various osteotomy depths during implant site preparation by bone condensing and by bone drilling as well as the dynamics of their change. Study design. In the present "in vitro" study, pig ribs with uniform thickness of cortical bone of 2 mm were used. Lateral bone-condensing (experimental group) and bone-drilling techniques (control group) were performed. Temperature changes were recorded at a distance of 0.5 mm from the final test osteotomy by 3 thermocouples at the depths of 1, 5, and 10 mm in tripod configuration. Data were collected from 48 measurements, 24 for each group. Results. Significantly higher mean temperature increase at the depth of 5 mm was observed during bone drilling compared with bone condensing, whereas for the depths of 1 and 10 mm differences were not significant between the 2 surgical techniques. During bone condensing, the mean temperature rise was continuously decreasing with increasing depth of osteotomies, whereas during bone drilling the mean temperature rise was first increased and reached a peak at the depth of 5 mm and then began to decrease with increasing depth of the osteotomies. Conclusions. The bone-condensing technique applied in the jaw bone class D4 offers an advantage over bone drilling because it generates a significantly smaller amount of heat. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 28-33)",
publisher = "Mosby-Elsevier, New York",
journal = "Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology",
title = "An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling",
volume = "112",
number = "1",
pages = "28-33",
doi = "10.1016/j.tripleo.2010.08.010"
}
Mišić, T., Marković, A., Todorović, A., Čolić, S., Šćepanović, M.,& Miličić, B.. (2011). An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling. in Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology
Mosby-Elsevier, New York., 112(1), 28-33.
https://doi.org/10.1016/j.tripleo.2010.08.010
Mišić T, Marković A, Todorović A, Čolić S, Šćepanović M, Miličić B. An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling. in Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology. 2011;112(1):28-33.
doi:10.1016/j.tripleo.2010.08.010 .
Mišić, Tijana, Marković, Aleksa, Todorović, Aleksandar, Čolić, Snježana, Šćepanović, Miodrag, Miličić, Biljana, "An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling" in Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology, 112, no. 1 (2011):28-33,
https://doi.org/10.1016/j.tripleo.2010.08.010 . .
25
21
27

Uticaj mini implantata na uspešnost i kvalitet protetske terapije bezubih pacijenata

Šćepanović, Miodrag

(Univerzitet u Beogradu, Stomatološki fakultet, 2011)

TY  - THES
AU  - Šćepanović, Miodrag
PY  - 2011
UR  - https://plus.sr.cobiss.net/opac7/bib/40745999
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/519
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Uticaj mini implantata na uspešnost i kvalitet protetske terapije bezubih pacijenata
UR  - https://hdl.handle.net/21.15107/rcub_smile_519
ER  - 
@phdthesis{
author = "Šćepanović, Miodrag",
year = "2011",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Uticaj mini implantata na uspešnost i kvalitet protetske terapije bezubih pacijenata",
url = "https://hdl.handle.net/21.15107/rcub_smile_519"
}
Šćepanović, M.. (2011). Uticaj mini implantata na uspešnost i kvalitet protetske terapije bezubih pacijenata. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_519
Šćepanović M. Uticaj mini implantata na uspešnost i kvalitet protetske terapije bezubih pacijenata. 2011;.
https://hdl.handle.net/21.15107/rcub_smile_519 .
Šćepanović, Miodrag, "Uticaj mini implantata na uspešnost i kvalitet protetske terapije bezubih pacijenata" (2011),
https://hdl.handle.net/21.15107/rcub_smile_519 .

Application of 'SKY PLAN X' system in the planning of implants installation in terminal mutual edentulism in the upper jaw

Vlahović, Zoran; Marković, Aleksa; Todorović, Aleksandar; Šćepanović, Miodrag

(Visoka medicinska škola strukovnih studija Ćuprija; Zavod za javno zdravlje Ćuprija „Pomoravlje“ Ćuprija; Srpsko lekarsko društvo Podružnica Ćuprija; Društvo za neuronauke „Sozercanje iz Šumadije“, Kr, 2010)

TY  - JOUR
AU  - Vlahović, Zoran
AU  - Marković, Aleksa
AU  - Todorović, Aleksandar
AU  - Šćepanović, Miodrag
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1545
AB  - An increasing patients' requirements put the dental implantology in the position where it is necessary to apply new digital technologies. In the paper, the case of 60 years old patient was presented, who was referred for prosthetic rehabilitation of maxilla with the fixed denture. After medical examination and upon X-rays imaging it was revealed that teeth 12, 11 and 22 can be used for prosthetic purposes where mutual tooth gaps in toothless jaw can be treated with implant supported fixed bridges. Because of limitation values of vertical and horizontal dimension of the bone, 3D orthopantomography was made as well as planning for implant position applying 'Sky Plan X System' manufactured by Bredent, which belongs to the group of static open systems. Upon surgical stent was made, implants were placed using 'flap less' method on solely available 15, 13, 23 and 26 positions. Three months afterwards final metal-ceramic denture was fixed over implant abutments posts. Computer guided implant application facilitates surgery-prosthetics treatment of the patient and it is mostly recommended for so called 'limitation cases' where our possibilities for placing implants are limited by anatomical factors.
AB  - Porast estetskih zahteva pacijenata stavlja dentalnu implantologiju u poziciju u kojoj je neophodna primena modernih digitalnih tehnologija. U radu je prikazan slučaj pacijenta starog 60 godina koji se javio radi protetske rehabilitacije gornje vilice fiksnim protetskim radom. Kliničkim pregledom i rentgenskom analizom utvrđeno je da se protetski mogu iskoristiti zubi 12, 11 i 22, a da se obostrana terminalna bezubost zbrine implantatno nošenim mostovima. Zbog graničnih vrednosti kako vertikalne, tako i horizontalne dimenzije kosti, pacijentu je urađen 3D ortopan snimak i planiranje pozicije implantata ' Sky plan X' sistemom, proizvođača Bredent, koji spada u grupu statičkih otvorenih sistema. Nakon izrade hirurškog stenta urađena je ugradnja implantata 'flap less' metodom na jedino mogućim pozicijama 15, 13, 23 i 26. Nakon tri meseca implantati su opterećeni i urađen definitivni metal-keramički protetski rad. Kompjuterom vođena ugradnja implantata znatno olakšava hirurško protetski tretman pacijenta i posebno je indikovana kod tzv. 'graničnih slučajeva' gde su nam mogućnosti za ugradnju implantata limitirane anatomskim faktorima.
PB  - Visoka medicinska škola strukovnih studija Ćuprija; Zavod za javno zdravlje Ćuprija „Pomoravlje“ Ćuprija; Srpsko lekarsko društvo Podružnica Ćuprija; Društvo za neuronauke „Sozercanje iz Šumadije“, Kr
T2  - PONS - medicinski časopis
T1  - Application of 'SKY PLAN X' system in the planning of implants installation in terminal mutual edentulism in the upper jaw
T1  - Primena 'SKY PLAN X' sistema u planiranju ugradnje implantata kod terminalne obostrane bezubosti gornje vilice
VL  - 7
IS  - 4
SP  - 157
EP  - 160
UR  - https://hdl.handle.net/21.15107/rcub_smile_1545
ER  - 
@article{
author = "Vlahović, Zoran and Marković, Aleksa and Todorović, Aleksandar and Šćepanović, Miodrag",
year = "2010",
abstract = "An increasing patients' requirements put the dental implantology in the position where it is necessary to apply new digital technologies. In the paper, the case of 60 years old patient was presented, who was referred for prosthetic rehabilitation of maxilla with the fixed denture. After medical examination and upon X-rays imaging it was revealed that teeth 12, 11 and 22 can be used for prosthetic purposes where mutual tooth gaps in toothless jaw can be treated with implant supported fixed bridges. Because of limitation values of vertical and horizontal dimension of the bone, 3D orthopantomography was made as well as planning for implant position applying 'Sky Plan X System' manufactured by Bredent, which belongs to the group of static open systems. Upon surgical stent was made, implants were placed using 'flap less' method on solely available 15, 13, 23 and 26 positions. Three months afterwards final metal-ceramic denture was fixed over implant abutments posts. Computer guided implant application facilitates surgery-prosthetics treatment of the patient and it is mostly recommended for so called 'limitation cases' where our possibilities for placing implants are limited by anatomical factors., Porast estetskih zahteva pacijenata stavlja dentalnu implantologiju u poziciju u kojoj je neophodna primena modernih digitalnih tehnologija. U radu je prikazan slučaj pacijenta starog 60 godina koji se javio radi protetske rehabilitacije gornje vilice fiksnim protetskim radom. Kliničkim pregledom i rentgenskom analizom utvrđeno je da se protetski mogu iskoristiti zubi 12, 11 i 22, a da se obostrana terminalna bezubost zbrine implantatno nošenim mostovima. Zbog graničnih vrednosti kako vertikalne, tako i horizontalne dimenzije kosti, pacijentu je urađen 3D ortopan snimak i planiranje pozicije implantata ' Sky plan X' sistemom, proizvođača Bredent, koji spada u grupu statičkih otvorenih sistema. Nakon izrade hirurškog stenta urađena je ugradnja implantata 'flap less' metodom na jedino mogućim pozicijama 15, 13, 23 i 26. Nakon tri meseca implantati su opterećeni i urađen definitivni metal-keramički protetski rad. Kompjuterom vođena ugradnja implantata znatno olakšava hirurško protetski tretman pacijenta i posebno je indikovana kod tzv. 'graničnih slučajeva' gde su nam mogućnosti za ugradnju implantata limitirane anatomskim faktorima.",
publisher = "Visoka medicinska škola strukovnih studija Ćuprija; Zavod za javno zdravlje Ćuprija „Pomoravlje“ Ćuprija; Srpsko lekarsko društvo Podružnica Ćuprija; Društvo za neuronauke „Sozercanje iz Šumadije“, Kr",
journal = "PONS - medicinski časopis",
title = "Application of 'SKY PLAN X' system in the planning of implants installation in terminal mutual edentulism in the upper jaw, Primena 'SKY PLAN X' sistema u planiranju ugradnje implantata kod terminalne obostrane bezubosti gornje vilice",
volume = "7",
number = "4",
pages = "157-160",
url = "https://hdl.handle.net/21.15107/rcub_smile_1545"
}
Vlahović, Z., Marković, A., Todorović, A.,& Šćepanović, M.. (2010). Application of 'SKY PLAN X' system in the planning of implants installation in terminal mutual edentulism in the upper jaw. in PONS - medicinski časopis
Visoka medicinska škola strukovnih studija Ćuprija; Zavod za javno zdravlje Ćuprija „Pomoravlje“ Ćuprija; Srpsko lekarsko društvo Podružnica Ćuprija; Društvo za neuronauke „Sozercanje iz Šumadije“, Kr., 7(4), 157-160.
https://hdl.handle.net/21.15107/rcub_smile_1545
Vlahović Z, Marković A, Todorović A, Šćepanović M. Application of 'SKY PLAN X' system in the planning of implants installation in terminal mutual edentulism in the upper jaw. in PONS - medicinski časopis. 2010;7(4):157-160.
https://hdl.handle.net/21.15107/rcub_smile_1545 .
Vlahović, Zoran, Marković, Aleksa, Todorović, Aleksandar, Šćepanović, Miodrag, "Application of 'SKY PLAN X' system in the planning of implants installation in terminal mutual edentulism in the upper jaw" in PONS - medicinski časopis, 7, no. 4 (2010):157-160,
https://hdl.handle.net/21.15107/rcub_smile_1545 .

Analiza oblika i provera stepena sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza

Šćepanović, Miodrag

(Univerzitet u Beogradu, Stomatološki fakultet, 2006)

TY  - THES
AU  - Šćepanović, Miodrag
PY  - 2006
UR  - https://plus.sr.cobiss.net/opac7/bib/1024164750
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/427
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Analiza oblika i provera stepena sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza
UR  - https://hdl.handle.net/21.15107/rcub_smile_427
ER  - 
@mastersthesis{
author = "Šćepanović, Miodrag",
year = "2006",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Analiza oblika i provera stepena sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza",
url = "https://hdl.handle.net/21.15107/rcub_smile_427"
}
Šćepanović, M.. (2006). Analiza oblika i provera stepena sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_427
Šćepanović M. Analiza oblika i provera stepena sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza. 2006;.
https://hdl.handle.net/21.15107/rcub_smile_427 .
Šćepanović, Miodrag, "Analiza oblika i provera stepena sigurnosti retencionih ručica kukica parcijalnih skeletiranih proteza" (2006),
https://hdl.handle.net/21.15107/rcub_smile_427 .

Mesiodens and paramolar in the medieval age skeletal remains

Tihaček-Šojić, Ljiljana; Šćepanović, Miodrag; Đurić, Marija

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2002)

TY  - JOUR
AU  - Tihaček-Šojić, Ljiljana
AU  - Šćepanović, Miodrag
AU  - Đurić, Marija
PY  - 2002
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1140
AB  - Evolution as in all segments of human behavior and existence has left traces on human teeth. The aim of this study was to determine the frequency of the supernumerary teeth in skeletal remains found at the archeological site Stara Torina and SEM evaluation of the changes on the supernumerary teeth. The study included 90 skulls and 81 jaws of both sexes with average age 20-60 years. Supernumerary teeth were prepared for SEM for analyzing dental tissues. Six supernumerary teeth were found, among them five mesiodensand one paramolar. The frequency of hyperdontia in these skeletal remains is 2,1%. Mesiodens is different morphologically from the incisor it replaced and took part in occlusal contacts during mastication. Paramolar is different morphologically from molar teeth and it did not take part in occlusal contacts during mastication because of its low adherence for bone tissues and small dimensions.
AB  - Evolucija je kao i u svim segmentima ljudskog oblika i postojanja, ostavila tragove i na ljudskim zubima. Cilj ovog rada bio je da se proceni učestalost prekobrojnih zuba u skeletnih ostataka sa lokaliteta Stara Torina I SEM-om verifikuju promene na prisutnim prekobrojnim zubima. Istraživanja skeletnih ostataka srednjovekovne populacije su realizovana na ukupno 90 lobanja i 81 vilici, oba pola, individualne starosti od 20-60 godina. Nađeni prekobrojni zubi su pripremljeni za analiziranje dentalnih tkiva metodom skenirajuće elektronske mikroskopije. Na ispitivanom skeletnom materijalu nađeno je šest prekobrojnih zuba i to pet meziodensa i jedan paramolar. Učestalost hiperdoncije u ovoj skeletnoj seriji iznosi 2, l %. Po svojim morfološkim karakteristikama meziodensi se razlikuju od zuba čije mesto zauzimaju, dok po strukturi tkiva ne pokazuju velika odstupanja. Paramolar se po svojim morfološkim karakteristikama znatno razlikuje od zuba molarne regije. Paramolar pokazuje velika odstupanja u strukturi u odnosu na zube molarne regije što se ogleda se u postojanju širih dentinskih kanalića.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Mesiodens and paramolar in the medieval age skeletal remains
T1  - Meziodens i paramolar kod srednjovekovnih skeletnih ostataka
VL  - 49
IS  - 3-4
SP  - 86
EP  - 89
DO  - 10.2298/SGS0204086T
ER  - 
@article{
author = "Tihaček-Šojić, Ljiljana and Šćepanović, Miodrag and Đurić, Marija",
year = "2002",
abstract = "Evolution as in all segments of human behavior and existence has left traces on human teeth. The aim of this study was to determine the frequency of the supernumerary teeth in skeletal remains found at the archeological site Stara Torina and SEM evaluation of the changes on the supernumerary teeth. The study included 90 skulls and 81 jaws of both sexes with average age 20-60 years. Supernumerary teeth were prepared for SEM for analyzing dental tissues. Six supernumerary teeth were found, among them five mesiodensand one paramolar. The frequency of hyperdontia in these skeletal remains is 2,1%. Mesiodens is different morphologically from the incisor it replaced and took part in occlusal contacts during mastication. Paramolar is different morphologically from molar teeth and it did not take part in occlusal contacts during mastication because of its low adherence for bone tissues and small dimensions., Evolucija je kao i u svim segmentima ljudskog oblika i postojanja, ostavila tragove i na ljudskim zubima. Cilj ovog rada bio je da se proceni učestalost prekobrojnih zuba u skeletnih ostataka sa lokaliteta Stara Torina I SEM-om verifikuju promene na prisutnim prekobrojnim zubima. Istraživanja skeletnih ostataka srednjovekovne populacije su realizovana na ukupno 90 lobanja i 81 vilici, oba pola, individualne starosti od 20-60 godina. Nađeni prekobrojni zubi su pripremljeni za analiziranje dentalnih tkiva metodom skenirajuće elektronske mikroskopije. Na ispitivanom skeletnom materijalu nađeno je šest prekobrojnih zuba i to pet meziodensa i jedan paramolar. Učestalost hiperdoncije u ovoj skeletnoj seriji iznosi 2, l %. Po svojim morfološkim karakteristikama meziodensi se razlikuju od zuba čije mesto zauzimaju, dok po strukturi tkiva ne pokazuju velika odstupanja. Paramolar se po svojim morfološkim karakteristikama znatno razlikuje od zuba molarne regije. Paramolar pokazuje velika odstupanja u strukturi u odnosu na zube molarne regije što se ogleda se u postojanju širih dentinskih kanalića.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Mesiodens and paramolar in the medieval age skeletal remains, Meziodens i paramolar kod srednjovekovnih skeletnih ostataka",
volume = "49",
number = "3-4",
pages = "86-89",
doi = "10.2298/SGS0204086T"
}
Tihaček-Šojić, L., Šćepanović, M.,& Đurić, M.. (2002). Mesiodens and paramolar in the medieval age skeletal remains. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 49(3-4), 86-89.
https://doi.org/10.2298/SGS0204086T
Tihaček-Šojić L, Šćepanović M, Đurić M. Mesiodens and paramolar in the medieval age skeletal remains. in Stomatološki glasnik Srbije. 2002;49(3-4):86-89.
doi:10.2298/SGS0204086T .
Tihaček-Šojić, Ljiljana, Šćepanović, Miodrag, Đurić, Marija, "Mesiodens and paramolar in the medieval age skeletal remains" in Stomatološki glasnik Srbije, 49, no. 3-4 (2002):86-89,
https://doi.org/10.2298/SGS0204086T . .

Scanning electron micrography of dental D material for manufacturing esthetic clasps

Tihaček-Šojić, Ljiljana; Šćepanović, Miodrag

(Udruženje stomatologa Srbije i Crne Gore - Sekcija za stomatološku protetiku, Beograd, 2001)

TY  - JOUR
AU  - Tihaček-Šojić, Ljiljana
AU  - Šćepanović, Miodrag
PY  - 2001
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1121
AB  - With a need for noninvasive methods and better esthetics solutions in dentistry, in a last few years, series of new materials in production of partial dentures turns up. Examination is done on Dental D® material for esthetic clasps. Some technical characteristics of the material are presented along with a production technique and also with our research. One of the ways for examination of material structure is scanning electron microscopy. With examination of Dental D® materials by micrographic methods, we reached some positive results, which may take noninvasive methods and esthetic in dentistry on a higher level.
AB  - Poslednjih godina se sa potrebom za neumornom metodama i boljim estetskim rešenjima u stomatologiji, pojavio niz novih materijala koji se koriste u izradi parcijalne skeletirane proteze. Ispitivan je Dental D materijal za izradu estetski kukica. U radu su predstavljene neke tehničke karakteristike materijala, tehnika izrade, a i naša ispitivanja ovog materijala. Skenirajuća elekronska mikroskopija je jedan od načina da se ispita površina i struktura materijala. Ispitivanjem Dental D® materijala mikrografskim metodama došli smo do pozitivnih rezultata koji mogu doprineti da se neinvazrvnost i estetika u stomatologiji podignu na viši nivo.
PB  - Udruženje stomatologa Srbije i Crne Gore - Sekcija za stomatološku protetiku, Beograd
T2  - Stomatološka protetika
T1  - Scanning electron micrography of dental D material for manufacturing esthetic clasps
T1  - Skenirajuća elektronska mikroskopija dental D materijala za izradu estetskih kukica
VL  - 2
IS  - 2
SP  - 73
EP  - 78
UR  - https://hdl.handle.net/21.15107/rcub_smile_1121
ER  - 
@article{
author = "Tihaček-Šojić, Ljiljana and Šćepanović, Miodrag",
year = "2001",
abstract = "With a need for noninvasive methods and better esthetics solutions in dentistry, in a last few years, series of new materials in production of partial dentures turns up. Examination is done on Dental D® material for esthetic clasps. Some technical characteristics of the material are presented along with a production technique and also with our research. One of the ways for examination of material structure is scanning electron microscopy. With examination of Dental D® materials by micrographic methods, we reached some positive results, which may take noninvasive methods and esthetic in dentistry on a higher level., Poslednjih godina se sa potrebom za neumornom metodama i boljim estetskim rešenjima u stomatologiji, pojavio niz novih materijala koji se koriste u izradi parcijalne skeletirane proteze. Ispitivan je Dental D materijal za izradu estetski kukica. U radu su predstavljene neke tehničke karakteristike materijala, tehnika izrade, a i naša ispitivanja ovog materijala. Skenirajuća elekronska mikroskopija je jedan od načina da se ispita površina i struktura materijala. Ispitivanjem Dental D® materijala mikrografskim metodama došli smo do pozitivnih rezultata koji mogu doprineti da se neinvazrvnost i estetika u stomatologiji podignu na viši nivo.",
publisher = "Udruženje stomatologa Srbije i Crne Gore - Sekcija za stomatološku protetiku, Beograd",
journal = "Stomatološka protetika",
title = "Scanning electron micrography of dental D material for manufacturing esthetic clasps, Skenirajuća elektronska mikroskopija dental D materijala za izradu estetskih kukica",
volume = "2",
number = "2",
pages = "73-78",
url = "https://hdl.handle.net/21.15107/rcub_smile_1121"
}
Tihaček-Šojić, L.,& Šćepanović, M.. (2001). Scanning electron micrography of dental D material for manufacturing esthetic clasps. in Stomatološka protetika
Udruženje stomatologa Srbije i Crne Gore - Sekcija za stomatološku protetiku, Beograd., 2(2), 73-78.
https://hdl.handle.net/21.15107/rcub_smile_1121
Tihaček-Šojić L, Šćepanović M. Scanning electron micrography of dental D material for manufacturing esthetic clasps. in Stomatološka protetika. 2001;2(2):73-78.
https://hdl.handle.net/21.15107/rcub_smile_1121 .
Tihaček-Šojić, Ljiljana, Šćepanović, Miodrag, "Scanning electron micrography of dental D material for manufacturing esthetic clasps" in Stomatološka protetika, 2, no. 2 (2001):73-78,
https://hdl.handle.net/21.15107/rcub_smile_1121 .