Arsenijević, Slobodan

Link to this page

Authority KeyName Variants
orcid::0000-0003-0494-1492
  • Arsenijević, Slobodan (2)
Projects

Author's Bibliography

Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study

Arsenijević, Petar; Milošević, Marko; Živanović, Aleksandar; Miličić, Biljana; Jeremić, Branislav; Filipović, Nenad; Protrka, Zoran; Todorović, Petar; Arsenijević, Slobodan

(BMC, LONDON, 2015)

TY  - JOUR
AU  - Arsenijević, Petar
AU  - Milošević, Marko
AU  - Živanović, Aleksandar
AU  - Miličić, Biljana
AU  - Jeremić, Branislav
AU  - Filipović, Nenad
AU  - Protrka, Zoran
AU  - Todorović, Petar
AU  - Arsenijević, Slobodan
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1993
AB  - Background: Hydraulic dilatation is a novel method of cervical dilatation that is based on continuous controllable dilatation (CCBD) by the pumping of fluid into the balloon extension of the system. The main advantage of this procedure is that it allows control of and insight into the process of cervical dilatation. Methods: For the purposes of our research, we created a new and upgraded system for CCBD which consists of a programmed hydrostatic pump connected to a balloon extension. With regard to our aim to precisely measure and determine the location of the cervical resistance, we placed two pressure-measuring films, one on the top and one on the bottom of the balloon extension. This study included 42 patients in whom cervical resistance was measured before suction curettage. Results: Cervical dilatation and measurement of cervical resistance were successful in all patients. The analysis of the pressure-measuring films showed that the points of highest resistance were located in the zone of the internal cervical os and that these values were much higher than those in the zone of the external cervical os (0.402 versus 0.264 MPa at the upper pressure-sensitive film; 0.387 versus 0.243 MPa at the lower pressure-sensitive film). This study also showed that an increase in cervical resistance in the zone of the internal cervical os was followed by an increase in cervical resistance in the zone of the external cervical os. Conclusions: During CCBD, the internal cervical os is the centre of cervical resistance, and the values do not decline with the number of miscarriages or the number of previous births.
PB  - BMC, LONDON
T2  - Trials
T1  - Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study
VL  - 16
DO  - 10.1186/s13063-015-1003-8
ER  - 
@article{
author = "Arsenijević, Petar and Milošević, Marko and Živanović, Aleksandar and Miličić, Biljana and Jeremić, Branislav and Filipović, Nenad and Protrka, Zoran and Todorović, Petar and Arsenijević, Slobodan",
year = "2015",
abstract = "Background: Hydraulic dilatation is a novel method of cervical dilatation that is based on continuous controllable dilatation (CCBD) by the pumping of fluid into the balloon extension of the system. The main advantage of this procedure is that it allows control of and insight into the process of cervical dilatation. Methods: For the purposes of our research, we created a new and upgraded system for CCBD which consists of a programmed hydrostatic pump connected to a balloon extension. With regard to our aim to precisely measure and determine the location of the cervical resistance, we placed two pressure-measuring films, one on the top and one on the bottom of the balloon extension. This study included 42 patients in whom cervical resistance was measured before suction curettage. Results: Cervical dilatation and measurement of cervical resistance were successful in all patients. The analysis of the pressure-measuring films showed that the points of highest resistance were located in the zone of the internal cervical os and that these values were much higher than those in the zone of the external cervical os (0.402 versus 0.264 MPa at the upper pressure-sensitive film; 0.387 versus 0.243 MPa at the lower pressure-sensitive film). This study also showed that an increase in cervical resistance in the zone of the internal cervical os was followed by an increase in cervical resistance in the zone of the external cervical os. Conclusions: During CCBD, the internal cervical os is the centre of cervical resistance, and the values do not decline with the number of miscarriages or the number of previous births.",
publisher = "BMC, LONDON",
journal = "Trials",
title = "Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study",
volume = "16",
doi = "10.1186/s13063-015-1003-8"
}
Arsenijević, P., Milošević, M., Živanović, A., Miličić, B., Jeremić, B., Filipović, N., Protrka, Z., Todorović, P.,& Arsenijević, S.. (2015). Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study. in Trials
BMC, LONDON., 16.
https://doi.org/10.1186/s13063-015-1003-8
Arsenijević P, Milošević M, Živanović A, Miličić B, Jeremić B, Filipović N, Protrka Z, Todorović P, Arsenijević S. Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study. in Trials. 2015;16.
doi:10.1186/s13063-015-1003-8 .
Arsenijević, Petar, Milošević, Marko, Živanović, Aleksandar, Miličić, Biljana, Jeremić, Branislav, Filipović, Nenad, Protrka, Zoran, Todorović, Petar, Arsenijević, Slobodan, "Analysis of cervical resistance during continuous controllable balloon dilatation: controlled clinical and experimental study" in Trials, 16 (2015),
https://doi.org/10.1186/s13063-015-1003-8 . .
1

A novel semi-quantitative method for measuring tissue bleeding

Vukcević, G.; Volarević, Vladislav; Raicević, S.; Tanasković, I.; Miličić, Biljana; Vulović, T.; Arsenijević, Slobodan

(F Hernandez, Murcia, 2014)

TY  - JOUR
AU  - Vukcević, G.
AU  - Volarević, Vladislav
AU  - Raicević, S.
AU  - Tanasković, I.
AU  - Miličić, Biljana
AU  - Vulović, T.
AU  - Arsenijević, Slobodan
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1950
AB  - In this study, we describe a new semi-quantitative method for measuring the extent of bleeding in pathohistological tissue samples. To test our novel method, we recruited 120 female patients in their first trimester of pregnancy and divided them into three groups of 40. Group I was the control group, in which no dilation was applied. Group II was an experimental group, in which dilation was performed using classical mechanical dilators. Group III was also an experimental group, in which dilation was performed using a hydraulic dilator. Tissue samples were taken from the patients' cervical canals using a Novak's probe via energetic single-step curettage prior to any dilation in Group I and after dilation in Groups II and III. After the tissue samples were prepared, light microscopy was used to obtain microphotographs at 100x magnification. The surfaces affected by bleeding were measured in the microphotographs using the Autodesk AutoCAD 2009 program and its "polylines" function. The lines were used to mark the area around the entire sample (marked A) and to create "polyline" areas around each bleeding area on the sample (marked B). The percentage of the total area affected by bleeding was calculated using the formula: N=Bt x 100 / At where N is the percentage (%) of the tissue sample surface affected by bleeding, At (A total) is the sum of the surfaces of all of the tissue samples and Bt (B total) is the sum of all the surfaces affected by bleeding in all of the tissue samples. This novel semi-quantitative method utilizes the Autodesk AutoCAD 2009 program, which is simple to use and widely available, thereby offering a new, objective and precise approach to estimate the extent of bleeding in tissue samples.
PB  - F Hernandez, Murcia
T2  - Histology & Histopathology
T1  - A novel semi-quantitative method for measuring tissue bleeding
VL  - 29
IS  - 3
SP  - 353
EP  - 360
UR  - https://hdl.handle.net/21.15107/rcub_smile_1950
ER  - 
@article{
author = "Vukcević, G. and Volarević, Vladislav and Raicević, S. and Tanasković, I. and Miličić, Biljana and Vulović, T. and Arsenijević, Slobodan",
year = "2014",
abstract = "In this study, we describe a new semi-quantitative method for measuring the extent of bleeding in pathohistological tissue samples. To test our novel method, we recruited 120 female patients in their first trimester of pregnancy and divided them into three groups of 40. Group I was the control group, in which no dilation was applied. Group II was an experimental group, in which dilation was performed using classical mechanical dilators. Group III was also an experimental group, in which dilation was performed using a hydraulic dilator. Tissue samples were taken from the patients' cervical canals using a Novak's probe via energetic single-step curettage prior to any dilation in Group I and after dilation in Groups II and III. After the tissue samples were prepared, light microscopy was used to obtain microphotographs at 100x magnification. The surfaces affected by bleeding were measured in the microphotographs using the Autodesk AutoCAD 2009 program and its "polylines" function. The lines were used to mark the area around the entire sample (marked A) and to create "polyline" areas around each bleeding area on the sample (marked B). The percentage of the total area affected by bleeding was calculated using the formula: N=Bt x 100 / At where N is the percentage (%) of the tissue sample surface affected by bleeding, At (A total) is the sum of the surfaces of all of the tissue samples and Bt (B total) is the sum of all the surfaces affected by bleeding in all of the tissue samples. This novel semi-quantitative method utilizes the Autodesk AutoCAD 2009 program, which is simple to use and widely available, thereby offering a new, objective and precise approach to estimate the extent of bleeding in tissue samples.",
publisher = "F Hernandez, Murcia",
journal = "Histology & Histopathology",
title = "A novel semi-quantitative method for measuring tissue bleeding",
volume = "29",
number = "3",
pages = "353-360",
url = "https://hdl.handle.net/21.15107/rcub_smile_1950"
}
Vukcević, G., Volarević, V., Raicević, S., Tanasković, I., Miličić, B., Vulović, T.,& Arsenijević, S.. (2014). A novel semi-quantitative method for measuring tissue bleeding. in Histology & Histopathology
F Hernandez, Murcia., 29(3), 353-360.
https://hdl.handle.net/21.15107/rcub_smile_1950
Vukcević G, Volarević V, Raicević S, Tanasković I, Miličić B, Vulović T, Arsenijević S. A novel semi-quantitative method for measuring tissue bleeding. in Histology & Histopathology. 2014;29(3):353-360.
https://hdl.handle.net/21.15107/rcub_smile_1950 .
Vukcević, G., Volarević, Vladislav, Raicević, S., Tanasković, I., Miličić, Biljana, Vulović, T., Arsenijević, Slobodan, "A novel semi-quantitative method for measuring tissue bleeding" in Histology & Histopathology, 29, no. 3 (2014):353-360,
https://hdl.handle.net/21.15107/rcub_smile_1950 .