Tanasić, Ivan

Link to this page

Authority KeyName Variants
orcid::0000-0002-5641-3475
  • Tanasić, Ivan (25)
Projects

Author's Bibliography

Mechanical Properties of Direct and Indirect Composite Materials Used in Prosthodontics

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra; Šojić, P.

(Springer, 2020)

TY  - CHAP
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
AU  - Šojić, P.
PY  - 2020
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2483
AB  - This study was conducted to investigate composite materials using mechanical equipment corresponded to masticatory system composed of two antagonistic parts that simulates bimaxilar contact in occlusion and articulation. The aim of this study was to investigate restorative materials with different chemical properties and to find out which material showed the best mechanical properties. The experiment was conducted using 4 types × 20 specimens of direct resin composite materials and equal number of indirect resin composites (IRCs). The following composites were tested: Tetric (Ivoclar Vivadent), Kerr Herculite XRV (Kerr), Charisma (Heraeus Kulzer), Heliomolar (Ivoclar Vivadent), Artglass (Heraeus Kulzer), Targis/Vectris (Ivoclar Vivadent), Vita Zeta LC (Vita) and Kerr Herculite Lab (Kerr). The universal dimensions of all specimens were 5 mm × 5 mm with 2 mm thickness. This was achieved using silicone molds. A total of 160 specimens (80 direct composite specimens and 80 indirect composite specimens) were tested using tensile testing machine. Artglass showed minimal change in thickness (30.20 ± 23.0 μm) compared to others. The highest change in thickness was found in Heliomolar (86.2 ± 32.6 μm). In the group of direct composite materials, Tetric experienced the lowest thickness change (31.0 ± 8.8 μm), while Charisma showed thickness variation of 65.2 ± 27.3 μm. Among indirect composites, Vita Zeta LC showed the highest value of thickness variation (76.2 ± 31.3 μm). In this experimental study, indirect composite specimens showed superior mechanical performance compared to direct composite specimens highlighted Artglass as the material of choice viewed from mechanical aspect.
PB  - Springer
T2  - Lecture Notes in Networks & Systems
T1  - Mechanical Properties of Direct and Indirect Composite Materials Used in Prosthodontics
VL  - 90
SP  - 103
EP  - 118
DO  - 10.1007/978-3-030-30853-7_7
ER  - 
@inbook{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra and Šojić, P.",
year = "2020",
abstract = "This study was conducted to investigate composite materials using mechanical equipment corresponded to masticatory system composed of two antagonistic parts that simulates bimaxilar contact in occlusion and articulation. The aim of this study was to investigate restorative materials with different chemical properties and to find out which material showed the best mechanical properties. The experiment was conducted using 4 types × 20 specimens of direct resin composite materials and equal number of indirect resin composites (IRCs). The following composites were tested: Tetric (Ivoclar Vivadent), Kerr Herculite XRV (Kerr), Charisma (Heraeus Kulzer), Heliomolar (Ivoclar Vivadent), Artglass (Heraeus Kulzer), Targis/Vectris (Ivoclar Vivadent), Vita Zeta LC (Vita) and Kerr Herculite Lab (Kerr). The universal dimensions of all specimens were 5 mm × 5 mm with 2 mm thickness. This was achieved using silicone molds. A total of 160 specimens (80 direct composite specimens and 80 indirect composite specimens) were tested using tensile testing machine. Artglass showed minimal change in thickness (30.20 ± 23.0 μm) compared to others. The highest change in thickness was found in Heliomolar (86.2 ± 32.6 μm). In the group of direct composite materials, Tetric experienced the lowest thickness change (31.0 ± 8.8 μm), while Charisma showed thickness variation of 65.2 ± 27.3 μm. Among indirect composites, Vita Zeta LC showed the highest value of thickness variation (76.2 ± 31.3 μm). In this experimental study, indirect composite specimens showed superior mechanical performance compared to direct composite specimens highlighted Artglass as the material of choice viewed from mechanical aspect.",
publisher = "Springer",
journal = "Lecture Notes in Networks & Systems",
booktitle = "Mechanical Properties of Direct and Indirect Composite Materials Used in Prosthodontics",
volume = "90",
pages = "103-118",
doi = "10.1007/978-3-030-30853-7_7"
}
Tanasić, I., Tihaček-Šojić, L., Milić-Lemić, A.,& Šojić, P.. (2020). Mechanical Properties of Direct and Indirect Composite Materials Used in Prosthodontics. in Lecture Notes in Networks & Systems
Springer., 90, 103-118.
https://doi.org/10.1007/978-3-030-30853-7_7
Tanasić I, Tihaček-Šojić L, Milić-Lemić A, Šojić P. Mechanical Properties of Direct and Indirect Composite Materials Used in Prosthodontics. in Lecture Notes in Networks & Systems. 2020;90:103-118.
doi:10.1007/978-3-030-30853-7_7 .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, Šojić, P., "Mechanical Properties of Direct and Indirect Composite Materials Used in Prosthodontics" in Lecture Notes in Networks & Systems, 90 (2020):103-118,
https://doi.org/10.1007/978-3-030-30853-7_7 . .
1

Analyzing strain in samples with all-ceramic systems using the digital image correlation technique

Tanasić, Ivan; Mitrović, Aleksandra; Mitrović, Nenad; Šarac, Dušan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra; Milošević, Miloš

(Srpsko lekarsko društvo, Beograd, 2019)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Mitrović, Aleksandra
AU  - Mitrović, Nenad
AU  - Šarac, Dušan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
AU  - Milošević, Miloš
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2466
AB  - Introduction/Objective The study was conducted to identify the maximum strain generated in the samples composed of poly-methyl-methacrylate, Straumann® implants, and three types of ceramic systems. Methods Three types of experimental models were used, loaded by external load of 100 N, 300 N, and 500 N and analyzed using the digital image correlation method. The models were composed of yttriastabilized zirconia, e.max lithium disilicate, and Vita Enamic® hybrid ceramics, placed on the Straumann® cylindrical dental implant systems (4 × 10 mm) with straight abutments. Results Significant differences in strain values between samples with different crown material groups were detected (p = 0.000). This suggests that strain values were dependent on the type of crown material. Strain values were also affected by the region of interest (p = 0.000). Application of two-way ANOVA enabled testing of the interaction effect between two independent variables, crown material and region of interest, where a significant difference was also found (p = 0.046). This indicates that strain values were also influenced by different combinations of material type and region of interest. The highest strain values were found for Z (0.383 ± 0.015) in the apical region, and the lowest for E (0.303 ± 0.015) in the middle region. Conclusion The study shows maximum strain in the apical and marginal directions. When considered various all-ceramics, we noticed the minimum strain below Vita Enamics®, while the maximum strain was found in samples with yttria-stabilized zirconia crown.
AB  - Uvod/Cilj Studija je sprovedena da identifikuje maksimalnu deformaciju proizvedenu u uzorcima sastavljenim od polimetilmetakrilata, Štrauman® implantata i tri vrste keramičkih sistema. Metode Korišćene su tri vrste eksperimentalnih modela izloženih spoljašnjem opterećenju od 100 N, 300 N i 500 N i analiziranih uz pomoć metoda korelacije digitalnih slika. Modeli su bili sastavljeni od itrijum-cirkonije, e. maks. litijum disilikatne i hibridnih keramika Vita enamik®, postavljenih na cilindrične dentalne implantantne sisteme Štrauman® (4 × 10 mm) sa abatmentima pod pravim uglom. Rezultati Značajne razlike su otkrivene u vrednostima deformacija između uzoraka sa različitim keramičkim krunicama (p = 0,000). Ovo podrazumeva da su vrednosti deformacija zavisne od tipa keramičkog materijala. Vrednosti deformacija su zavisne i od regiona interesa (p = 0,000). Primena ANOVA testa je omogućila da se uoči interakcija između nezavisnih varijabli, meterijala keramičkih kruna i regiona od interesa, gde je takođe nađena statistički značajna razlika (p = 0,046). Ova činjenica ukazuje na to da vrednosti deformacija zavise od različite kombinacije tipa keramičkog materijala i regiona interesa. Najveće vrednosti deformacija su nađene na modelu Z (0,383 ± 0,015) u apikalnom regionu, dok su najmanje vrednosti deformacija nađene na modelu E (0,303 ± 0,015) u regionu srednje trećine. Zaključak Izveštaj je pokazao maksimalne deformacije u apikalnim i marginalnim pravcima. Kada se razmatraju različite vrste keramika, najmanje deformacije su primećene ispod kruna Vita enamik®, dok je najveća deformacija pronađena u uzorcima sa krunama itrijum-cirkonija.
PB  - Srpsko lekarsko društvo, Beograd
T2  - Srpski arhiv za celokupno lekarstvo
T1  - Analyzing strain in samples with all-ceramic systems using the digital image correlation technique
T1  - Analiza deformacija u uzorcima sastavljenim od keramičkih sistema primenom metode digitalne korelacije slika
VL  - 147
IS  - 9-10
SP  - 528
EP  - 533
DO  - 10.2298/SARH171030085T
ER  - 
@article{
author = "Tanasić, Ivan and Mitrović, Aleksandra and Mitrović, Nenad and Šarac, Dušan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra and Milošević, Miloš",
year = "2019",
abstract = "Introduction/Objective The study was conducted to identify the maximum strain generated in the samples composed of poly-methyl-methacrylate, Straumann® implants, and three types of ceramic systems. Methods Three types of experimental models were used, loaded by external load of 100 N, 300 N, and 500 N and analyzed using the digital image correlation method. The models were composed of yttriastabilized zirconia, e.max lithium disilicate, and Vita Enamic® hybrid ceramics, placed on the Straumann® cylindrical dental implant systems (4 × 10 mm) with straight abutments. Results Significant differences in strain values between samples with different crown material groups were detected (p = 0.000). This suggests that strain values were dependent on the type of crown material. Strain values were also affected by the region of interest (p = 0.000). Application of two-way ANOVA enabled testing of the interaction effect between two independent variables, crown material and region of interest, where a significant difference was also found (p = 0.046). This indicates that strain values were also influenced by different combinations of material type and region of interest. The highest strain values were found for Z (0.383 ± 0.015) in the apical region, and the lowest for E (0.303 ± 0.015) in the middle region. Conclusion The study shows maximum strain in the apical and marginal directions. When considered various all-ceramics, we noticed the minimum strain below Vita Enamics®, while the maximum strain was found in samples with yttria-stabilized zirconia crown., Uvod/Cilj Studija je sprovedena da identifikuje maksimalnu deformaciju proizvedenu u uzorcima sastavljenim od polimetilmetakrilata, Štrauman® implantata i tri vrste keramičkih sistema. Metode Korišćene su tri vrste eksperimentalnih modela izloženih spoljašnjem opterećenju od 100 N, 300 N i 500 N i analiziranih uz pomoć metoda korelacije digitalnih slika. Modeli su bili sastavljeni od itrijum-cirkonije, e. maks. litijum disilikatne i hibridnih keramika Vita enamik®, postavljenih na cilindrične dentalne implantantne sisteme Štrauman® (4 × 10 mm) sa abatmentima pod pravim uglom. Rezultati Značajne razlike su otkrivene u vrednostima deformacija između uzoraka sa različitim keramičkim krunicama (p = 0,000). Ovo podrazumeva da su vrednosti deformacija zavisne od tipa keramičkog materijala. Vrednosti deformacija su zavisne i od regiona interesa (p = 0,000). Primena ANOVA testa je omogućila da se uoči interakcija između nezavisnih varijabli, meterijala keramičkih kruna i regiona od interesa, gde je takođe nađena statistički značajna razlika (p = 0,046). Ova činjenica ukazuje na to da vrednosti deformacija zavise od različite kombinacije tipa keramičkog materijala i regiona interesa. Najveće vrednosti deformacija su nađene na modelu Z (0,383 ± 0,015) u apikalnom regionu, dok su najmanje vrednosti deformacija nađene na modelu E (0,303 ± 0,015) u regionu srednje trećine. Zaključak Izveštaj je pokazao maksimalne deformacije u apikalnim i marginalnim pravcima. Kada se razmatraju različite vrste keramika, najmanje deformacije su primećene ispod kruna Vita enamik®, dok je najveća deformacija pronađena u uzorcima sa krunama itrijum-cirkonija.",
publisher = "Srpsko lekarsko društvo, Beograd",
journal = "Srpski arhiv za celokupno lekarstvo",
title = "Analyzing strain in samples with all-ceramic systems using the digital image correlation technique, Analiza deformacija u uzorcima sastavljenim od keramičkih sistema primenom metode digitalne korelacije slika",
volume = "147",
number = "9-10",
pages = "528-533",
doi = "10.2298/SARH171030085T"
}
Tanasić, I., Mitrović, A., Mitrović, N., Šarac, D., Tihaček-Šojić, L., Milić-Lemić, A.,& Milošević, M.. (2019). Analyzing strain in samples with all-ceramic systems using the digital image correlation technique. in Srpski arhiv za celokupno lekarstvo
Srpsko lekarsko društvo, Beograd., 147(9-10), 528-533.
https://doi.org/10.2298/SARH171030085T
Tanasić I, Mitrović A, Mitrović N, Šarac D, Tihaček-Šojić L, Milić-Lemić A, Milošević M. Analyzing strain in samples with all-ceramic systems using the digital image correlation technique. in Srpski arhiv za celokupno lekarstvo. 2019;147(9-10):528-533.
doi:10.2298/SARH171030085T .
Tanasić, Ivan, Mitrović, Aleksandra, Mitrović, Nenad, Šarac, Dušan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, Milošević, Miloš, "Analyzing strain in samples with all-ceramic systems using the digital image correlation technique" in Srpski arhiv za celokupno lekarstvo, 147, no. 9-10 (2019):528-533,
https://doi.org/10.2298/SARH171030085T . .
3
3

Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks

Šarac, Dušan; Mitrović, Nenad; Tanasić, Ivan; Misković, Žarko; Tihaček-Šojić, Ljiljana

(Inst Za Kovinske Materiale I In Tehnologie, Ljubjana, 2019)

TY  - JOUR
AU  - Šarac, Dušan
AU  - Mitrović, Nenad
AU  - Tanasić, Ivan
AU  - Misković, Žarko
AU  - Tihaček-Šojić, Ljiljana
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2450
AB  - Dental-implant overload can cause bone resorption. Load-transfer characteristics of dental implants are affected by their macro-design parameters. The goal of this study was to experimentally analyse the load-transfer characteristics of different dental implants, using polymethyl-methacrylate blocks. Three polymethyl-methacrylate blocks were created, with dimensions of (68 x 25 x 9) mm. Three dental implants, Nobel empty set3.5 mm x 15 mm, Strauman empty set4.1 mm x 10 mm and Strauman empty set4.8 mm x 12 mm. were placed in separate blocks. The samples were supported by a three-point-bending set-up and loaded with an axial force of 600 N. The 3D digital image correlation method was employed for strain and displacement measurements. The highest displacement and von Mises strain values were found for Strauman empty set4.1 mm x 10 mm (p  lt  0.05), 0.186 mm and 0.596 %, respectively. The sample of Nobel empty set3.5 mm x 15 mm showed the lowest strain values. The sample of Strauman empty set4.8 mm x 12 mm (p > 0.05) had similar strain values as Nobel empty set3.5 mm x 15 mm. The load transfer during axial loading was primarily affected by the size of the implant contact surface. The displacement and strain values in the implant vicinity may provide an insight into the effect of dental-implant design on the load transfer.
PB  - Inst Za Kovinske Materiale I In Tehnologie, Ljubjana
T2  - Materiali in Tehnologije
T1  - Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks
VL  - 53
IS  - 1
SP  - 133
EP  - 137
DO  - 10.17222/mit.2018.081
ER  - 
@article{
author = "Šarac, Dušan and Mitrović, Nenad and Tanasić, Ivan and Misković, Žarko and Tihaček-Šojić, Ljiljana",
year = "2019",
abstract = "Dental-implant overload can cause bone resorption. Load-transfer characteristics of dental implants are affected by their macro-design parameters. The goal of this study was to experimentally analyse the load-transfer characteristics of different dental implants, using polymethyl-methacrylate blocks. Three polymethyl-methacrylate blocks were created, with dimensions of (68 x 25 x 9) mm. Three dental implants, Nobel empty set3.5 mm x 15 mm, Strauman empty set4.1 mm x 10 mm and Strauman empty set4.8 mm x 12 mm. were placed in separate blocks. The samples were supported by a three-point-bending set-up and loaded with an axial force of 600 N. The 3D digital image correlation method was employed for strain and displacement measurements. The highest displacement and von Mises strain values were found for Strauman empty set4.1 mm x 10 mm (p  lt  0.05), 0.186 mm and 0.596 %, respectively. The sample of Nobel empty set3.5 mm x 15 mm showed the lowest strain values. The sample of Strauman empty set4.8 mm x 12 mm (p > 0.05) had similar strain values as Nobel empty set3.5 mm x 15 mm. The load transfer during axial loading was primarily affected by the size of the implant contact surface. The displacement and strain values in the implant vicinity may provide an insight into the effect of dental-implant design on the load transfer.",
publisher = "Inst Za Kovinske Materiale I In Tehnologie, Ljubjana",
journal = "Materiali in Tehnologije",
title = "Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks",
volume = "53",
number = "1",
pages = "133-137",
doi = "10.17222/mit.2018.081"
}
Šarac, D., Mitrović, N., Tanasić, I., Misković, Ž.,& Tihaček-Šojić, L.. (2019). Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks. in Materiali in Tehnologije
Inst Za Kovinske Materiale I In Tehnologie, Ljubjana., 53(1), 133-137.
https://doi.org/10.17222/mit.2018.081
Šarac D, Mitrović N, Tanasić I, Misković Ž, Tihaček-Šojić L. Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks. in Materiali in Tehnologije. 2019;53(1):133-137.
doi:10.17222/mit.2018.081 .
Šarac, Dušan, Mitrović, Nenad, Tanasić, Ivan, Misković, Žarko, Tihaček-Šojić, Ljiljana, "Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks" in Materiali in Tehnologije, 53, no. 1 (2019):133-137,
https://doi.org/10.17222/mit.2018.081 . .
2
2

3D Digital Image Correlation Analysis of the Shrinkage Strain in Four Dual Cure Composite Cements

Mitrović, Aleksandra; Antonović, Dušan; Tanasić, Ivan; Mitrović, Nenad; Bakić, Gordana; Popović, Dejana; Milošević, Miloš

(Hindawi Ltd, London, 2019)

TY  - JOUR
AU  - Mitrović, Aleksandra
AU  - Antonović, Dušan
AU  - Tanasić, Ivan
AU  - Mitrović, Nenad
AU  - Bakić, Gordana
AU  - Popović, Dejana
AU  - Milošević, Miloš
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2420
AB  - The introduction of resin-based cements and an adhesive-bonding system in daily dental practice has given the opportunity to increase the retention of previously conventional cemented restorations and the optimal results in esthetic. This experimental study employed the 3D Digital Image Correlation Method (3D-DIC) for detecting shrinkage strain in four dual cured composite cements. The aim was to visualize measure, analyze, and compare strain fields in four resin-based cements using the 3D-DIC method. A total of 72 samples were divided into 4 groups considering variations in sample types, diameter, and thickness. Four types of composite cements: RelyX U200 (3 M ESPE, St. Paul, MN, USA), MaxCem Elite (Kerr, Orange, CA, USA), Multilink Automix (Ivoclar Vivadent, Schaan, Liechtenstein), and SeT PP (SDI, Australia) were used. Each type had diameters of 3 mm, 4 mm, and 5 mm, respectively, combined with two different values of thickness: 1 mm and 2 mm. Thickness had an important role on strain detected in all tested materials showing higher strain in samples with 2 mm thickness compared to 1 mm samples. Shrinkage strain values were the highest in Set PP samples indicated the possibility of undesirable de-bonding.
PB  - Hindawi Ltd, London
T2  - Biomed Research International
T1  - 3D Digital Image Correlation Analysis of the Shrinkage Strain in Four Dual Cure Composite Cements
VL  - 2019
DO  - 10.1155/2019/2041348
ER  - 
@article{
author = "Mitrović, Aleksandra and Antonović, Dušan and Tanasić, Ivan and Mitrović, Nenad and Bakić, Gordana and Popović, Dejana and Milošević, Miloš",
year = "2019",
abstract = "The introduction of resin-based cements and an adhesive-bonding system in daily dental practice has given the opportunity to increase the retention of previously conventional cemented restorations and the optimal results in esthetic. This experimental study employed the 3D Digital Image Correlation Method (3D-DIC) for detecting shrinkage strain in four dual cured composite cements. The aim was to visualize measure, analyze, and compare strain fields in four resin-based cements using the 3D-DIC method. A total of 72 samples were divided into 4 groups considering variations in sample types, diameter, and thickness. Four types of composite cements: RelyX U200 (3 M ESPE, St. Paul, MN, USA), MaxCem Elite (Kerr, Orange, CA, USA), Multilink Automix (Ivoclar Vivadent, Schaan, Liechtenstein), and SeT PP (SDI, Australia) were used. Each type had diameters of 3 mm, 4 mm, and 5 mm, respectively, combined with two different values of thickness: 1 mm and 2 mm. Thickness had an important role on strain detected in all tested materials showing higher strain in samples with 2 mm thickness compared to 1 mm samples. Shrinkage strain values were the highest in Set PP samples indicated the possibility of undesirable de-bonding.",
publisher = "Hindawi Ltd, London",
journal = "Biomed Research International",
title = "3D Digital Image Correlation Analysis of the Shrinkage Strain in Four Dual Cure Composite Cements",
volume = "2019",
doi = "10.1155/2019/2041348"
}
Mitrović, A., Antonović, D., Tanasić, I., Mitrović, N., Bakić, G., Popović, D.,& Milošević, M.. (2019). 3D Digital Image Correlation Analysis of the Shrinkage Strain in Four Dual Cure Composite Cements. in Biomed Research International
Hindawi Ltd, London., 2019.
https://doi.org/10.1155/2019/2041348
Mitrović A, Antonović D, Tanasić I, Mitrović N, Bakić G, Popović D, Milošević M. 3D Digital Image Correlation Analysis of the Shrinkage Strain in Four Dual Cure Composite Cements. in Biomed Research International. 2019;2019.
doi:10.1155/2019/2041348 .
Mitrović, Aleksandra, Antonović, Dušan, Tanasić, Ivan, Mitrović, Nenad, Bakić, Gordana, Popović, Dejana, Milošević, Miloš, "3D Digital Image Correlation Analysis of the Shrinkage Strain in Four Dual Cure Composite Cements" in Biomed Research International, 2019 (2019),
https://doi.org/10.1155/2019/2041348 . .
8
2
10

Strain field measurements of glass ionomer cement

Mitrović, Aleksandra; Mitrović, Nenad; Tanasić, Ivan; Milošević, Miloš; Antonović, Dušan

(Institut za ispitivanje materijala, Beograd, 2019)

TY  - JOUR
AU  - Mitrović, Aleksandra
AU  - Mitrović, Nenad
AU  - Tanasić, Ivan
AU  - Milošević, Miloš
AU  - Antonović, Dušan
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2399
AB  - Extensive evolution of glass ionomer cements (GIC) has marked a significant shift in the practice of luting indirect dental restorations limiting the use of zinc-phosphate and zinc-polycarboxylate cements to a few indications. GIC are now one of the materials of choice for cementation of all ceramics, fiber reinforced composite posts and veneers. GICs are determined by unique properties like chemical adhesion to tooth and base metals, low thermal expansion coefficients similar to dentin and minimal microleakage at the tooth-enamel interface due to low shrinkage. Shrinkage strain is identified as the cause, and the associated stress as the mechanism for the loss of marginal adaption and cohesive fracture within the material. The aim of this study is to measure the strain and displacement field in a conventional GIC (Riva Luting, SDI, Australia) related to different cement diameter, using 3D Digital Image Correlation (DIC) method. The experiment is done for samples with thickness of 1 mm combined with diameters of 4 mm (Group I) and 3 mm (Group II). The strain field is measured using 3D 11optical system Aramis 2M (GOM, Braunschweig, Germany). This study provides valuable data about strain behaviour and displacement as a possible failure factor in GIC, Riva Luting. Visible differences between Group I and Group II were observed.
PB  - Institut za ispitivanje materijala, Beograd
T2  - Structural Integrity & Life
T1  - Strain field measurements of glass ionomer cement
VL  - 19
IS  - 2
SP  - 143
EP  - 147
UR  - https://hdl.handle.net/21.15107/rcub_smile_2399
ER  - 
@article{
author = "Mitrović, Aleksandra and Mitrović, Nenad and Tanasić, Ivan and Milošević, Miloš and Antonović, Dušan",
year = "2019",
abstract = "Extensive evolution of glass ionomer cements (GIC) has marked a significant shift in the practice of luting indirect dental restorations limiting the use of zinc-phosphate and zinc-polycarboxylate cements to a few indications. GIC are now one of the materials of choice for cementation of all ceramics, fiber reinforced composite posts and veneers. GICs are determined by unique properties like chemical adhesion to tooth and base metals, low thermal expansion coefficients similar to dentin and minimal microleakage at the tooth-enamel interface due to low shrinkage. Shrinkage strain is identified as the cause, and the associated stress as the mechanism for the loss of marginal adaption and cohesive fracture within the material. The aim of this study is to measure the strain and displacement field in a conventional GIC (Riva Luting, SDI, Australia) related to different cement diameter, using 3D Digital Image Correlation (DIC) method. The experiment is done for samples with thickness of 1 mm combined with diameters of 4 mm (Group I) and 3 mm (Group II). The strain field is measured using 3D 11optical system Aramis 2M (GOM, Braunschweig, Germany). This study provides valuable data about strain behaviour and displacement as a possible failure factor in GIC, Riva Luting. Visible differences between Group I and Group II were observed.",
publisher = "Institut za ispitivanje materijala, Beograd",
journal = "Structural Integrity & Life",
title = "Strain field measurements of glass ionomer cement",
volume = "19",
number = "2",
pages = "143-147",
url = "https://hdl.handle.net/21.15107/rcub_smile_2399"
}
Mitrović, A., Mitrović, N., Tanasić, I., Milošević, M.,& Antonović, D.. (2019). Strain field measurements of glass ionomer cement. in Structural Integrity & Life
Institut za ispitivanje materijala, Beograd., 19(2), 143-147.
https://hdl.handle.net/21.15107/rcub_smile_2399
Mitrović A, Mitrović N, Tanasić I, Milošević M, Antonović D. Strain field measurements of glass ionomer cement. in Structural Integrity & Life. 2019;19(2):143-147.
https://hdl.handle.net/21.15107/rcub_smile_2399 .
Mitrović, Aleksandra, Mitrović, Nenad, Tanasić, Ivan, Milošević, Miloš, Antonović, Dušan, "Strain field measurements of glass ionomer cement" in Structural Integrity & Life, 19, no. 2 (2019):143-147,
https://hdl.handle.net/21.15107/rcub_smile_2399 .
1
7

Analysis of the strain and hardness in self-cured and light-cured self-adhesive resin based cement

Mitrović, Aleksandra; Tanasić, Ivan; Mitrović, Nenad; Miletić, Vesna; Bakić, Gordana; Milošević, Miloš; Antonović, Dušan

(Taylor & Francis Ltd, Abingdon, 2019)

TY  - JOUR
AU  - Mitrović, Aleksandra
AU  - Tanasić, Ivan
AU  - Mitrović, Nenad
AU  - Miletić, Vesna
AU  - Bakić, Gordana
AU  - Milošević, Miloš
AU  - Antonović, Dušan
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2396
AB  - The study showed an application of the 3 D Digital Image Correlation Method (3 D-DIC) for detection of von Mises strain in samples of the self-etch, self-adhesive resin based cement (RBC). The aim was to determine and compare strain in the self-cured and light-cured Maxcem Elite, furthermore to investigate the hardness of these two cement-types. The experiment was carried out using two groups of Maxcem Elite (Kerr, Orange, CA, USA) samples; each tested group includes five (o5 x 2 mm sized) samples, for both self-curing and light-curing mode. All samples were prepared by filling teflon ring-type molds. In addition, Vickers micro-hardness was measured for all samples. Maxcem Elite showed similar maximum strain values from 10% to 12% for both groups. Besides the maximum strain value, the 3 D-DIC method also enabled monitoring the change of strain field even after the recommended polymerization time. This method has shown that the polymerization shrinkage continues even after 10 min which disagreed with manufacturer's suggestion. Group II showed maximum strain values of 12% in the peripheral zone after 10 min, in the last Stage (Stage 60). Statistically significant difference was not found in the overall strain between self- and light-cured Maxcem Elite neither peripherally (p = 0.118) nor centrally (p = 0.879). However, statistical significance was found in strain regarding central and peripheral zone in both, self-cured (p = 0.020) and light-cured (p = 0.002) Maxcem Elite. The mean von Mises strain values in the periphery of the samples (Section 0) were significantly higher compared to strain values in the center of the samples (for Section 1 and 2). The last stage (Stage 60) of the light-cured Maxcem Elite polymerization showed significantly higher values of von Mises strain compared to initial stage (Stage 0). Higher values of micro-hardness were noticed on the surfaces directly exposed to LED lamp after performing measurements of micro-hardness on light-cured samples.
PB  - Taylor & Francis Ltd, Abingdon
T2  - Journal of Adhesion Science & Technology
T1  - Analysis of the strain and hardness in self-cured and light-cured self-adhesive resin based cement
VL  - 33
IS  - 24
SP  - 2684
EP  - 2695
DO  - 10.1080/01694243.2019.1654221
ER  - 
@article{
author = "Mitrović, Aleksandra and Tanasić, Ivan and Mitrović, Nenad and Miletić, Vesna and Bakić, Gordana and Milošević, Miloš and Antonović, Dušan",
year = "2019",
abstract = "The study showed an application of the 3 D Digital Image Correlation Method (3 D-DIC) for detection of von Mises strain in samples of the self-etch, self-adhesive resin based cement (RBC). The aim was to determine and compare strain in the self-cured and light-cured Maxcem Elite, furthermore to investigate the hardness of these two cement-types. The experiment was carried out using two groups of Maxcem Elite (Kerr, Orange, CA, USA) samples; each tested group includes five (o5 x 2 mm sized) samples, for both self-curing and light-curing mode. All samples were prepared by filling teflon ring-type molds. In addition, Vickers micro-hardness was measured for all samples. Maxcem Elite showed similar maximum strain values from 10% to 12% for both groups. Besides the maximum strain value, the 3 D-DIC method also enabled monitoring the change of strain field even after the recommended polymerization time. This method has shown that the polymerization shrinkage continues even after 10 min which disagreed with manufacturer's suggestion. Group II showed maximum strain values of 12% in the peripheral zone after 10 min, in the last Stage (Stage 60). Statistically significant difference was not found in the overall strain between self- and light-cured Maxcem Elite neither peripherally (p = 0.118) nor centrally (p = 0.879). However, statistical significance was found in strain regarding central and peripheral zone in both, self-cured (p = 0.020) and light-cured (p = 0.002) Maxcem Elite. The mean von Mises strain values in the periphery of the samples (Section 0) were significantly higher compared to strain values in the center of the samples (for Section 1 and 2). The last stage (Stage 60) of the light-cured Maxcem Elite polymerization showed significantly higher values of von Mises strain compared to initial stage (Stage 0). Higher values of micro-hardness were noticed on the surfaces directly exposed to LED lamp after performing measurements of micro-hardness on light-cured samples.",
publisher = "Taylor & Francis Ltd, Abingdon",
journal = "Journal of Adhesion Science & Technology",
title = "Analysis of the strain and hardness in self-cured and light-cured self-adhesive resin based cement",
volume = "33",
number = "24",
pages = "2684-2695",
doi = "10.1080/01694243.2019.1654221"
}
Mitrović, A., Tanasić, I., Mitrović, N., Miletić, V., Bakić, G., Milošević, M.,& Antonović, D.. (2019). Analysis of the strain and hardness in self-cured and light-cured self-adhesive resin based cement. in Journal of Adhesion Science & Technology
Taylor & Francis Ltd, Abingdon., 33(24), 2684-2695.
https://doi.org/10.1080/01694243.2019.1654221
Mitrović A, Tanasić I, Mitrović N, Miletić V, Bakić G, Milošević M, Antonović D. Analysis of the strain and hardness in self-cured and light-cured self-adhesive resin based cement. in Journal of Adhesion Science & Technology. 2019;33(24):2684-2695.
doi:10.1080/01694243.2019.1654221 .
Mitrović, Aleksandra, Tanasić, Ivan, Mitrović, Nenad, Miletić, Vesna, Bakić, Gordana, Milošević, Miloš, Antonović, Dušan, "Analysis of the strain and hardness in self-cured and light-cured self-adhesive resin based cement" in Journal of Adhesion Science & Technology, 33, no. 24 (2019):2684-2695,
https://doi.org/10.1080/01694243.2019.1654221 . .
2
2

Stress and strain distribution in the lower jaw with shortened dental arch: A finite element method study

Milić-Lemić, Aleksandra; Tanasić, Ivan; Tihaček-Šojić, Ljiljana

(Srpsko lekarsko društvo, Beograd, 2018)

TY  - JOUR
AU  - Milić-Lemić, Aleksandra
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
PY  - 2018
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2351
AB  - Introduction/Objective The absence of functional loading due to molar loss might cause changes to the microstructure of the bone. Therefore we investigated and visualized deformation and strain pattern distribution of the mandibule with full arch dentition (FDA) and shortened dental arches (SDA) during occlusion. Methods A 3D model of an adult cadaveric dentate mandible, without pathological and traumatic damages, was developed based on CT scan images, set to 0.7 mm slice thickness. The scanned slices were imported into software where the bone and teeth were identified and modelled separately based on image density thresholding. Using the software and based on the grey-scale analysis of the slices initial meshes for the cortical, cancellous bone and teeth were generated. Results Highest stress/strain values were registered in the structures adjacent to molars i.e. molar region of processus alveolaris assigned by blue color in FDA model. Similar to FDA, the SDA models exibited deformation with evident highest strain (9.33%) at the processus coronoideus and mandibular angle. The highest overall stress (5 MPa) and strain (6.67%) was found in the mandibular intercanine segment of the SDA model, considering the mandibular body. Conclusion Finite element method can be employed as a powerfull tool for visualization of the stress and strain of the loaded mandible models with full and shortened dental arches. It was registered that molar support loss caused higher stress and strain in SDAs compared to FDA model.
AB  - Uvod/Cilj Odsustvo funkcionalnog opterećenja usled gubitka molara može izazvati promene u mikrostrukturi kosti. Cilj ovog istraživanja je bio da se ispitaju i vizuelizuju naponi i deformacije u mandibulama sa intaktnim zubnim lukom (IZL) i skraćenim zubnim lukom (SZL) u toku okluzije. Metod 3D model kadaverske donje vilice odrasle osobe (procenjena vizuelnim pregledom bez patoloških i traumatskih oštećenja) razvijen je na osnovu KT slike, debljine sloja od 0,7 mm. Skenirani preseci su uneti u softver gde su identifikovana i modelirana tvrda tkiva kosti i zubi pojedinačno na osnovu segmentacije slike. Početne mreže za kortikalnu kost, spongioznu kost i zube su proizvedene korišćenjem softvera i na osnovu analize sive skale preseka. Rezultati Najveće vrednosti napona i deformacija su registrovane u strukturama donje vilice neposredno uz molare u tzv. molarnom regionu alveolarnog nastavka, što je označeno plavom bojom na IZL modelu. Slično IZL, i SZL modeli su pokazali najveće vrednosti deformacija (9,33%) u koronoidnom nastavku i mandibularnom uglu. Najveći napon (5 MPa) i deformacija (6,67%) pronađeni su u interkaninom regionu SZL modela, ukoliko se razmatra telo donje vilice. Zaključak Metodom konačnih elemenata su vizuelizovane slike napona i deformacija modela donje vilice sa punim i skraćenim zubnim lukovima. Uočeno je da gubitak molarne potpore izaziva jače napone i deformacije u SZL modelima u poređenju sa IZL modelom.
PB  - Srpsko lekarsko društvo, Beograd
T2  - Srpski arhiv za celokupno lekarstvo
T1  - Stress and strain distribution in the lower jaw with shortened dental arch: A finite element method study
T1  - Distribucija napona i deformacija u donjoj vilici sa skraćenim zubnim lukom - studija metodom konačnih elemenata
VL  - 146
IS  - 11-12
SP  - 629
EP  - 633
DO  - 10.2298/SARH171106026M
ER  - 
@article{
author = "Milić-Lemić, Aleksandra and Tanasić, Ivan and Tihaček-Šojić, Ljiljana",
year = "2018",
abstract = "Introduction/Objective The absence of functional loading due to molar loss might cause changes to the microstructure of the bone. Therefore we investigated and visualized deformation and strain pattern distribution of the mandibule with full arch dentition (FDA) and shortened dental arches (SDA) during occlusion. Methods A 3D model of an adult cadaveric dentate mandible, without pathological and traumatic damages, was developed based on CT scan images, set to 0.7 mm slice thickness. The scanned slices were imported into software where the bone and teeth were identified and modelled separately based on image density thresholding. Using the software and based on the grey-scale analysis of the slices initial meshes for the cortical, cancellous bone and teeth were generated. Results Highest stress/strain values were registered in the structures adjacent to molars i.e. molar region of processus alveolaris assigned by blue color in FDA model. Similar to FDA, the SDA models exibited deformation with evident highest strain (9.33%) at the processus coronoideus and mandibular angle. The highest overall stress (5 MPa) and strain (6.67%) was found in the mandibular intercanine segment of the SDA model, considering the mandibular body. Conclusion Finite element method can be employed as a powerfull tool for visualization of the stress and strain of the loaded mandible models with full and shortened dental arches. It was registered that molar support loss caused higher stress and strain in SDAs compared to FDA model., Uvod/Cilj Odsustvo funkcionalnog opterećenja usled gubitka molara može izazvati promene u mikrostrukturi kosti. Cilj ovog istraživanja je bio da se ispitaju i vizuelizuju naponi i deformacije u mandibulama sa intaktnim zubnim lukom (IZL) i skraćenim zubnim lukom (SZL) u toku okluzije. Metod 3D model kadaverske donje vilice odrasle osobe (procenjena vizuelnim pregledom bez patoloških i traumatskih oštećenja) razvijen je na osnovu KT slike, debljine sloja od 0,7 mm. Skenirani preseci su uneti u softver gde su identifikovana i modelirana tvrda tkiva kosti i zubi pojedinačno na osnovu segmentacije slike. Početne mreže za kortikalnu kost, spongioznu kost i zube su proizvedene korišćenjem softvera i na osnovu analize sive skale preseka. Rezultati Najveće vrednosti napona i deformacija su registrovane u strukturama donje vilice neposredno uz molare u tzv. molarnom regionu alveolarnog nastavka, što je označeno plavom bojom na IZL modelu. Slično IZL, i SZL modeli su pokazali najveće vrednosti deformacija (9,33%) u koronoidnom nastavku i mandibularnom uglu. Najveći napon (5 MPa) i deformacija (6,67%) pronađeni su u interkaninom regionu SZL modela, ukoliko se razmatra telo donje vilice. Zaključak Metodom konačnih elemenata su vizuelizovane slike napona i deformacija modela donje vilice sa punim i skraćenim zubnim lukovima. Uočeno je da gubitak molarne potpore izaziva jače napone i deformacije u SZL modelima u poređenju sa IZL modelom.",
publisher = "Srpsko lekarsko društvo, Beograd",
journal = "Srpski arhiv za celokupno lekarstvo",
title = "Stress and strain distribution in the lower jaw with shortened dental arch: A finite element method study, Distribucija napona i deformacija u donjoj vilici sa skraćenim zubnim lukom - studija metodom konačnih elemenata",
volume = "146",
number = "11-12",
pages = "629-633",
doi = "10.2298/SARH171106026M"
}
Milić-Lemić, A., Tanasić, I.,& Tihaček-Šojić, L.. (2018). Stress and strain distribution in the lower jaw with shortened dental arch: A finite element method study. in Srpski arhiv za celokupno lekarstvo
Srpsko lekarsko društvo, Beograd., 146(11-12), 629-633.
https://doi.org/10.2298/SARH171106026M
Milić-Lemić A, Tanasić I, Tihaček-Šojić L. Stress and strain distribution in the lower jaw with shortened dental arch: A finite element method study. in Srpski arhiv za celokupno lekarstvo. 2018;146(11-12):629-633.
doi:10.2298/SARH171106026M .
Milić-Lemić, Aleksandra, Tanasić, Ivan, Tihaček-Šojić, Ljiljana, "Stress and strain distribution in the lower jaw with shortened dental arch: A finite element method study" in Srpski arhiv za celokupno lekarstvo, 146, no. 11-12 (2018):629-633,
https://doi.org/10.2298/SARH171106026M . .
1
1
1

Strain visualization of supporting tissues rehabilitated using two different types of removable partial dentures

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra

(Srpsko lekarsko društvo, Beograd, 2018)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
PY  - 2018
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2348
AB  - Introduction/Objective Current biomechanical analyses can provide full view of the strain induced by loading of various replacements to be used for prosthetic rehabilitation. The aim of this study was to analyze strain distribution of supporting tissues beneath two different types of removable partial dentures, commonly indicated in the conventional rehabilitation of partially edentulous patients. Methods This in vitro study included two groups of experimental models composed of the mandibles (Kenedy Class 1) and two types of removable partial dentures. These models were exposed to occlusal loading and the digital image correlation method was used for strain visualization and strain measurement. Results The highest strain was measured beneath the removable partial dentures, on the surfaces of bone adjacent to distal abutments and in the anatomical structure called the retromolar area. Strain values in the experimental models with clasp removable partial dentures ranged 0-10%. Strain values in the experimental models with attachment - removable partial dentures ranged 0-2.3%. Conclusion The findings showed that the attachment retaining removable partial dentures induced lower strain in the residual alveolar ridges. However, higher strain was detected in the marginal bone next to the abutment teeth.
AB  - Uvod/Cilj Savremene biomehaničke analize omogućavaju kompletnu vizuelizaciju deformacija od opterećivanja različitih zubnih nadoknada u protetskoj rehabilitaciji. Cilj ove studije je bio da analiza distribucije deformacija unutar potpornih tkiva ispod dva različita tipa najčešće korišćenih parcijalnih skeletiranih proteza. Metode In vitro studija je obuhvatila dve grupe eksperimentalnih modela donjih vilica (Kenedi 1 klasa krezubosti) i dva tipa parcijalnih skeletiranih proteza. Modeli su bili izloženi okluzalnim silama, a za prikaz i merenje deformacija je korišćena metoda digitalne korelacije slika. Rezultati Najveća deformacija je izmerena ispod parcijalnih proteza, na površinama kosti koja okružuje distalne zube nosače i u retromolarnoj regiji. Vrednosti deformacija u eksperimentalnim modelima sa protezama retiniranim livenim kukicama su bile 0-10%. Vrednosti deformacija u eksperimentalnim modelima sa protezama retiniranim atečmenima su bile 0-2,3%. Zaključak Parcijalne skeletirane proteze sa atečmenima indukovale su manje deformacije rezidualnog alveolarnog grebena. Veće deformacije su uočene u marginalnoj kosti koja je u neposrednom kontaktu sa zubima nosačima.
PB  - Srpsko lekarsko društvo, Beograd
T2  - Srpski arhiv za celokupno lekarstvo
T1  - Strain visualization of supporting tissues rehabilitated using two different types of removable partial dentures
T1  - Vizuelizacija deformacija u potpornim tkivima rehabilitovanim sa dva različita tipa parcijalnih skeletiranih proteza
VL  - 146
IS  - 9-10
SP  - 498
EP  - 505
DO  - 10.2298/SARH170725181T
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra",
year = "2018",
abstract = "Introduction/Objective Current biomechanical analyses can provide full view of the strain induced by loading of various replacements to be used for prosthetic rehabilitation. The aim of this study was to analyze strain distribution of supporting tissues beneath two different types of removable partial dentures, commonly indicated in the conventional rehabilitation of partially edentulous patients. Methods This in vitro study included two groups of experimental models composed of the mandibles (Kenedy Class 1) and two types of removable partial dentures. These models were exposed to occlusal loading and the digital image correlation method was used for strain visualization and strain measurement. Results The highest strain was measured beneath the removable partial dentures, on the surfaces of bone adjacent to distal abutments and in the anatomical structure called the retromolar area. Strain values in the experimental models with clasp removable partial dentures ranged 0-10%. Strain values in the experimental models with attachment - removable partial dentures ranged 0-2.3%. Conclusion The findings showed that the attachment retaining removable partial dentures induced lower strain in the residual alveolar ridges. However, higher strain was detected in the marginal bone next to the abutment teeth., Uvod/Cilj Savremene biomehaničke analize omogućavaju kompletnu vizuelizaciju deformacija od opterećivanja različitih zubnih nadoknada u protetskoj rehabilitaciji. Cilj ove studije je bio da analiza distribucije deformacija unutar potpornih tkiva ispod dva različita tipa najčešće korišćenih parcijalnih skeletiranih proteza. Metode In vitro studija je obuhvatila dve grupe eksperimentalnih modela donjih vilica (Kenedi 1 klasa krezubosti) i dva tipa parcijalnih skeletiranih proteza. Modeli su bili izloženi okluzalnim silama, a za prikaz i merenje deformacija je korišćena metoda digitalne korelacije slika. Rezultati Najveća deformacija je izmerena ispod parcijalnih proteza, na površinama kosti koja okružuje distalne zube nosače i u retromolarnoj regiji. Vrednosti deformacija u eksperimentalnim modelima sa protezama retiniranim livenim kukicama su bile 0-10%. Vrednosti deformacija u eksperimentalnim modelima sa protezama retiniranim atečmenima su bile 0-2,3%. Zaključak Parcijalne skeletirane proteze sa atečmenima indukovale su manje deformacije rezidualnog alveolarnog grebena. Veće deformacije su uočene u marginalnoj kosti koja je u neposrednom kontaktu sa zubima nosačima.",
publisher = "Srpsko lekarsko društvo, Beograd",
journal = "Srpski arhiv za celokupno lekarstvo",
title = "Strain visualization of supporting tissues rehabilitated using two different types of removable partial dentures, Vizuelizacija deformacija u potpornim tkivima rehabilitovanim sa dva različita tipa parcijalnih skeletiranih proteza",
volume = "146",
number = "9-10",
pages = "498-505",
doi = "10.2298/SARH170725181T"
}
Tanasić, I., Tihaček-Šojić, L.,& Milić-Lemić, A.. (2018). Strain visualization of supporting tissues rehabilitated using two different types of removable partial dentures. in Srpski arhiv za celokupno lekarstvo
Srpsko lekarsko društvo, Beograd., 146(9-10), 498-505.
https://doi.org/10.2298/SARH170725181T
Tanasić I, Tihaček-Šojić L, Milić-Lemić A. Strain visualization of supporting tissues rehabilitated using two different types of removable partial dentures. in Srpski arhiv za celokupno lekarstvo. 2018;146(9-10):498-505.
doi:10.2298/SARH170725181T .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, "Strain visualization of supporting tissues rehabilitated using two different types of removable partial dentures" in Srpski arhiv za celokupno lekarstvo, 146, no. 9-10 (2018):498-505,
https://doi.org/10.2298/SARH170725181T . .
1
2
2

Strain determination of self-adhesive resin cement using 3D digital image correlation method

Mitrović, Aleksandra; Tanasić, Ivan; Mitrović, Nenad; Milošević, Miloš S.; Tihaček-Šojić, Ljiljana; Antonović, Dušan

(Srpsko lekarsko društvo, Beograd, 2018)

TY  - JOUR
AU  - Mitrović, Aleksandra
AU  - Tanasić, Ivan
AU  - Mitrović, Nenad
AU  - Milošević, Miloš S.
AU  - Tihaček-Šojić, Ljiljana
AU  - Antonović, Dušan
PY  - 2018
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2345
AB  - Introduction/Objective In an attempt to simplify dental procedures, a new group of resin cements, self-adhesive resin cements (SARCs), have been introduced. Performance of SARCs can widely vary. One of the main reasons of adhesion failure is polymerization shrinkage. The aim of this study was to determine, evaluate, and measure strain field of self-adhesive dual cure resin cement during polymerization in self-cure mode using 3D digital image correlation (DIC) method. Methods The self-adhesive Maxcem Elite (Kerr, Orange, CA, USA) cement was tested in five cylindrical samples (5 mm in diameter and 2 mm in thickness) prepared by filling plastic ring-type molds. Digital images were recorded immediately after sample preparation. Results Non-uniform strain distribution was found in resin cement with higher strain values along the periphery (up to 15%) and lower strain values in central parts (around 4%) of each sample. Conclusion It can be concluded that DIC is a powerful tool for full-field strain measurements in material characterization.
AB  - Uvod/Cilj U nastojanju da se pojednostave stomatološke procedure uvedene su nove grupe kompozitnih cemenata - samoadhezivni, dvojnovezujući kompozitni cementi. Svojstva ovih cemenata mogu da variraju u velikoj meri. Jedan od glavnih razloga narušavanja adhezionih svojstava kompozitnih cemenata je polimerizacijska kontrakcija. Cilj ovog rada je da se odredi i izmeri deformaciono polje samoadhezivnog dvojnovezujućeg kompozitnog cementa tokom hemijske polimerizacije korišćenjem eksperimentalne tehnike - metode 3D korelacije digitalnih slika. Metode Samoadhezivni kompozitni cement Maxcem Elite (Kerr, Orange, SAD) ispitivan je na pet uzoraka prečnika 5 mm, debljine 2 mm, koji su pripremljeni punjenjem plastičnih kalupa prstenastog oblika. Digitalne slike su zabeležene neposredno posle pripreme uzoraka. Rezultati Neuniformno deformaciono polje je pokazalo veće vrednosti deformacija na periferiji uzoraka (do 15%) i manje vrednosti deformacija u centralnim delovima uzoraka (oko 4%). Zaključak Može se zaključiti da je 3D korelacija digitalnih slika precizna i pouzdana metoda za merenje deformacionih polja u oblasti karakterizacije materijala.
PB  - Srpsko lekarsko društvo, Beograd
T2  - Srpski arhiv za celokupno lekarstvo
T1  - Strain determination of self-adhesive resin cement using 3D digital image correlation method
T1  - Utvrđivanje opterećenja samovezujućeg kompozitnog cementa primenom metode 3D korelacije digitalnih slika
VL  - 146
IS  - 7-8
SP  - 372
EP  - 377
DO  - 10.2298/SARH170530176M
ER  - 
@article{
author = "Mitrović, Aleksandra and Tanasić, Ivan and Mitrović, Nenad and Milošević, Miloš S. and Tihaček-Šojić, Ljiljana and Antonović, Dušan",
year = "2018",
abstract = "Introduction/Objective In an attempt to simplify dental procedures, a new group of resin cements, self-adhesive resin cements (SARCs), have been introduced. Performance of SARCs can widely vary. One of the main reasons of adhesion failure is polymerization shrinkage. The aim of this study was to determine, evaluate, and measure strain field of self-adhesive dual cure resin cement during polymerization in self-cure mode using 3D digital image correlation (DIC) method. Methods The self-adhesive Maxcem Elite (Kerr, Orange, CA, USA) cement was tested in five cylindrical samples (5 mm in diameter and 2 mm in thickness) prepared by filling plastic ring-type molds. Digital images were recorded immediately after sample preparation. Results Non-uniform strain distribution was found in resin cement with higher strain values along the periphery (up to 15%) and lower strain values in central parts (around 4%) of each sample. Conclusion It can be concluded that DIC is a powerful tool for full-field strain measurements in material characterization., Uvod/Cilj U nastojanju da se pojednostave stomatološke procedure uvedene su nove grupe kompozitnih cemenata - samoadhezivni, dvojnovezujući kompozitni cementi. Svojstva ovih cemenata mogu da variraju u velikoj meri. Jedan od glavnih razloga narušavanja adhezionih svojstava kompozitnih cemenata je polimerizacijska kontrakcija. Cilj ovog rada je da se odredi i izmeri deformaciono polje samoadhezivnog dvojnovezujućeg kompozitnog cementa tokom hemijske polimerizacije korišćenjem eksperimentalne tehnike - metode 3D korelacije digitalnih slika. Metode Samoadhezivni kompozitni cement Maxcem Elite (Kerr, Orange, SAD) ispitivan je na pet uzoraka prečnika 5 mm, debljine 2 mm, koji su pripremljeni punjenjem plastičnih kalupa prstenastog oblika. Digitalne slike su zabeležene neposredno posle pripreme uzoraka. Rezultati Neuniformno deformaciono polje je pokazalo veće vrednosti deformacija na periferiji uzoraka (do 15%) i manje vrednosti deformacija u centralnim delovima uzoraka (oko 4%). Zaključak Može se zaključiti da je 3D korelacija digitalnih slika precizna i pouzdana metoda za merenje deformacionih polja u oblasti karakterizacije materijala.",
publisher = "Srpsko lekarsko društvo, Beograd",
journal = "Srpski arhiv za celokupno lekarstvo",
title = "Strain determination of self-adhesive resin cement using 3D digital image correlation method, Utvrđivanje opterećenja samovezujućeg kompozitnog cementa primenom metode 3D korelacije digitalnih slika",
volume = "146",
number = "7-8",
pages = "372-377",
doi = "10.2298/SARH170530176M"
}
Mitrović, A., Tanasić, I., Mitrović, N., Milošević, M. S., Tihaček-Šojić, L.,& Antonović, D.. (2018). Strain determination of self-adhesive resin cement using 3D digital image correlation method. in Srpski arhiv za celokupno lekarstvo
Srpsko lekarsko društvo, Beograd., 146(7-8), 372-377.
https://doi.org/10.2298/SARH170530176M
Mitrović A, Tanasić I, Mitrović N, Milošević MS, Tihaček-Šojić L, Antonović D. Strain determination of self-adhesive resin cement using 3D digital image correlation method. in Srpski arhiv za celokupno lekarstvo. 2018;146(7-8):372-377.
doi:10.2298/SARH170530176M .
Mitrović, Aleksandra, Tanasić, Ivan, Mitrović, Nenad, Milošević, Miloš S., Tihaček-Šojić, Ljiljana, Antonović, Dušan, "Strain determination of self-adhesive resin cement using 3D digital image correlation method" in Srpski arhiv za celokupno lekarstvo, 146, no. 7-8 (2018):372-377,
https://doi.org/10.2298/SARH170530176M . .
5
5

Experimental methodology for analysis of influence of dental implant design on load transfer

Šarac, Dušan; Mitrović, Nenad; Tanasić, Ivan; Tihaček-Šojić, Ljiljana

(Univerzitet u Beogradu - Mašinski fakultet, Beograd, 2018)

TY  - JOUR
AU  - Šarac, Dušan
AU  - Mitrović, Nenad
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
PY  - 2018
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2336
AB  - Deformations in the vicinity of dental implants are affected by their design and if threshold level of 0.3 % is surpassed, bone resorption could occur. The goal of this study is to present a novel experimental approch for the analysis of effect od dental implant geometry on the surrounding structure strain values. A bone block model, with dimensions of 68x25x9 mm, was made from polymethyl-methacrylate. 3D printed block mold also provided a fixture for vertically placed Strauman ø4.0x12 mm. The sample was loaded in a three-point bending setup. The axial force of 600 N was applied on the dental implant. The Digital Image Correlation method was used for strain and displacement measurement. The highest von Mises strain of 0.7 % is located in the area of implant neck. The maximum displacement value in loading direction was 0.466 mm. Surface strain and displacement are correlated with implant geometry. This experimental methodology can be utilized to estimate dental implant load transfer characteristics.
AB  - Dizajn dentalnih implanata utiče na vrednosti deformacija koje nastaju u njihovoj okolini, i ako se pređe granična vrednost od 0.3 %, može doći do resorpcije kosti. Cilj ove studije je da predstavi novi eksperimentalni pristup za analizu uticaja geometrije dentalnih implanata na deformacije okolne strukture. Model kosti, sa dimenzijama od 68h25h9 mm, je napravljen od polimetil-metakrilata. Kalup za model koji je napravljen pomoću tehnike 3D štampe, je takođe služio i kao fiksator položaja za vertikalno postavljeni implant Štrauman ø4.0x12 mm. Uzorak je opterećen na savijanje u tri tačke. Aksijalna sila od 600 N je primenjena na dentalni implant. Za merenje deformacija i pomeraja je korišćena metoda Digitalne korelacije slika. Najveće vrednosti Von Mizesovih deformacija od 0.7 % su izmerene u području vrata implanta. Maksimalne vrednosti pomeraja u pravcu opterećenja su iznosile 0.466 mm. Površinska deformacija i pomeraji su povezani sa geometrijom implanata. Ova eksperimentalna metodologija se može koristiti u cilju određivanja karakteristika prenosa opterećenja dentalnih.
PB  - Univerzitet u Beogradu - Mašinski fakultet, Beograd
T2  - FME Transactions
T1  - Experimental methodology for analysis of influence of dental implant design on load transfer
T1  - Eksperimentalna metodologija za određivanje uticaja dizajna dentalnih implanata na prenos opterećenja
VL  - 46
IS  - 2
SP  - 266
EP  - 271
DO  - 10.5937/fmet1802266S
ER  - 
@article{
author = "Šarac, Dušan and Mitrović, Nenad and Tanasić, Ivan and Tihaček-Šojić, Ljiljana",
year = "2018",
abstract = "Deformations in the vicinity of dental implants are affected by their design and if threshold level of 0.3 % is surpassed, bone resorption could occur. The goal of this study is to present a novel experimental approch for the analysis of effect od dental implant geometry on the surrounding structure strain values. A bone block model, with dimensions of 68x25x9 mm, was made from polymethyl-methacrylate. 3D printed block mold also provided a fixture for vertically placed Strauman ø4.0x12 mm. The sample was loaded in a three-point bending setup. The axial force of 600 N was applied on the dental implant. The Digital Image Correlation method was used for strain and displacement measurement. The highest von Mises strain of 0.7 % is located in the area of implant neck. The maximum displacement value in loading direction was 0.466 mm. Surface strain and displacement are correlated with implant geometry. This experimental methodology can be utilized to estimate dental implant load transfer characteristics., Dizajn dentalnih implanata utiče na vrednosti deformacija koje nastaju u njihovoj okolini, i ako se pređe granična vrednost od 0.3 %, može doći do resorpcije kosti. Cilj ove studije je da predstavi novi eksperimentalni pristup za analizu uticaja geometrije dentalnih implanata na deformacije okolne strukture. Model kosti, sa dimenzijama od 68h25h9 mm, je napravljen od polimetil-metakrilata. Kalup za model koji je napravljen pomoću tehnike 3D štampe, je takođe služio i kao fiksator položaja za vertikalno postavljeni implant Štrauman ø4.0x12 mm. Uzorak je opterećen na savijanje u tri tačke. Aksijalna sila od 600 N je primenjena na dentalni implant. Za merenje deformacija i pomeraja je korišćena metoda Digitalne korelacije slika. Najveće vrednosti Von Mizesovih deformacija od 0.7 % su izmerene u području vrata implanta. Maksimalne vrednosti pomeraja u pravcu opterećenja su iznosile 0.466 mm. Površinska deformacija i pomeraji su povezani sa geometrijom implanata. Ova eksperimentalna metodologija se može koristiti u cilju određivanja karakteristika prenosa opterećenja dentalnih.",
publisher = "Univerzitet u Beogradu - Mašinski fakultet, Beograd",
journal = "FME Transactions",
title = "Experimental methodology for analysis of influence of dental implant design on load transfer, Eksperimentalna metodologija za određivanje uticaja dizajna dentalnih implanata na prenos opterećenja",
volume = "46",
number = "2",
pages = "266-271",
doi = "10.5937/fmet1802266S"
}
Šarac, D., Mitrović, N., Tanasić, I.,& Tihaček-Šojić, L.. (2018). Experimental methodology for analysis of influence of dental implant design on load transfer. in FME Transactions
Univerzitet u Beogradu - Mašinski fakultet, Beograd., 46(2), 266-271.
https://doi.org/10.5937/fmet1802266S
Šarac D, Mitrović N, Tanasić I, Tihaček-Šojić L. Experimental methodology for analysis of influence of dental implant design on load transfer. in FME Transactions. 2018;46(2):266-271.
doi:10.5937/fmet1802266S .
Šarac, Dušan, Mitrović, Nenad, Tanasić, Ivan, Tihaček-Šojić, Ljiljana, "Experimental methodology for analysis of influence of dental implant design on load transfer" in FME Transactions, 46, no. 2 (2018):266-271,
https://doi.org/10.5937/fmet1802266S . .
1
1

Effect of Prosthetic Rehabilitation on Nutritional Status in Older Adults

Tanasić, Ivan; Radaković, Tijana; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra

(Lippincott Williams & Wilkins, Philadelphia, 2017)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Radaković, Tijana
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2212
AB  - This study aimed to assess the effectiveness of various combinations of the implant-supported overdentures and removable partial dentures on nutritional status in a randomized sample of 150 older adults. The body mass index (BMI) and the Mini Nutritional Assessment (MNA) were recorded before and after prosthetic rehabilitation. There was statistically significant improvement in the MNA and BMI, measured before prosthetic rehabilitation, and after 6 and 12 months (P  lt  .001). The prosthetic rehabilitation of patients 65 years and older, using implant-supported overdentures and removable partial dentures, improved BMI and MNA scores used in the assessment of nutritional status.
PB  - Lippincott Williams & Wilkins, Philadelphia
T2  - Topics in Clinical Nutrition
T1  - Effect of Prosthetic Rehabilitation on Nutritional Status in Older Adults
VL  - 32
IS  - 4
SP  - 330
EP  - 339
DO  - 10.1097/TIN.0000000000000118
ER  - 
@article{
author = "Tanasić, Ivan and Radaković, Tijana and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra",
year = "2017",
abstract = "This study aimed to assess the effectiveness of various combinations of the implant-supported overdentures and removable partial dentures on nutritional status in a randomized sample of 150 older adults. The body mass index (BMI) and the Mini Nutritional Assessment (MNA) were recorded before and after prosthetic rehabilitation. There was statistically significant improvement in the MNA and BMI, measured before prosthetic rehabilitation, and after 6 and 12 months (P  lt  .001). The prosthetic rehabilitation of patients 65 years and older, using implant-supported overdentures and removable partial dentures, improved BMI and MNA scores used in the assessment of nutritional status.",
publisher = "Lippincott Williams & Wilkins, Philadelphia",
journal = "Topics in Clinical Nutrition",
title = "Effect of Prosthetic Rehabilitation on Nutritional Status in Older Adults",
volume = "32",
number = "4",
pages = "330-339",
doi = "10.1097/TIN.0000000000000118"
}
Tanasić, I., Radaković, T., Tihaček-Šojić, L.,& Milić-Lemić, A.. (2017). Effect of Prosthetic Rehabilitation on Nutritional Status in Older Adults. in Topics in Clinical Nutrition
Lippincott Williams & Wilkins, Philadelphia., 32(4), 330-339.
https://doi.org/10.1097/TIN.0000000000000118
Tanasić I, Radaković T, Tihaček-Šojić L, Milić-Lemić A. Effect of Prosthetic Rehabilitation on Nutritional Status in Older Adults. in Topics in Clinical Nutrition. 2017;32(4):330-339.
doi:10.1097/TIN.0000000000000118 .
Tanasić, Ivan, Radaković, Tijana, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, "Effect of Prosthetic Rehabilitation on Nutritional Status in Older Adults" in Topics in Clinical Nutrition, 32, no. 4 (2017):330-339,
https://doi.org/10.1097/TIN.0000000000000118 . .
1
2
1

Analysis of the effect of implant distance from the surrounding structure, in the PMMA block model

Mitrović, Nenad; Tanasić, Ivan; Šarac, Dušan; Milošević, Miloš; Misković, Žarko; Tihaček-Šojić, Ljiljana; Sedmak, Aleksandar

(Elsevier Science Bv, Amsterdam, 2016)

TY  - CONF
AU  - Mitrović, Nenad
AU  - Tanasić, Ivan
AU  - Šarac, Dušan
AU  - Milošević, Miloš
AU  - Misković, Žarko
AU  - Tihaček-Šojić, Ljiljana
AU  - Sedmak, Aleksandar
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2113
AB  - Strain analysis in the vicinity of the dental implants were the subject of many research papers. In this study, new experimental method was employed for strain determination in the surrounding area of the axially loaded dental implant, which was embedded in the resin block. This studies can improve understanding of strain distribution, and its possible effects on the surrounding structure. Dental Implant Branemark with dimensions of 14 x 3.75 mm was immersed into rectangular block of polymethil methacrylate in vertical position. Implant was distanced 2 mm and 4 mm from the block sides, and they were named as the surface 1 and surface 2, respectively. Axial load, in the range of 0 - 500 N, was applied using Universal testing machine Tinius Olsen. Digital Image Correlation method was used for measuring deformation. Results were presented in the form of horizontal and vertical strains. Horizontal strains were mostly tensile, with maximum value of 0.3 % on the bottom of the surface 1. This values decreased in the upper area of the block side. Vertical compressive strain were 2-3 times higher on the surface 1, when compared to the surface 2, with maximum values of 0.7 % located on the bottom of the surface 1, and 0.3 % on the bottom of the surface 2. Resin block models could be used for determination of strain distribution under axially loaded implants. Greatest strain concentration were located under the implants apex, in the bottom area of the block. It was concluded that, in this region, strain values decreased linearly with increase of distance from the implants surface.
PB  - Elsevier Science Bv, Amsterdam
C3  - 21st European Conference on Fracture, (ECF21)
T1  - Analysis of the effect of implant distance from the surrounding structure, in the PMMA block model
VL  - 2
SP  - 1260
EP  - 1265
DO  - 10.1016/j.prostr.2016.06.161
ER  - 
@conference{
author = "Mitrović, Nenad and Tanasić, Ivan and Šarac, Dušan and Milošević, Miloš and Misković, Žarko and Tihaček-Šojić, Ljiljana and Sedmak, Aleksandar",
year = "2016",
abstract = "Strain analysis in the vicinity of the dental implants were the subject of many research papers. In this study, new experimental method was employed for strain determination in the surrounding area of the axially loaded dental implant, which was embedded in the resin block. This studies can improve understanding of strain distribution, and its possible effects on the surrounding structure. Dental Implant Branemark with dimensions of 14 x 3.75 mm was immersed into rectangular block of polymethil methacrylate in vertical position. Implant was distanced 2 mm and 4 mm from the block sides, and they were named as the surface 1 and surface 2, respectively. Axial load, in the range of 0 - 500 N, was applied using Universal testing machine Tinius Olsen. Digital Image Correlation method was used for measuring deformation. Results were presented in the form of horizontal and vertical strains. Horizontal strains were mostly tensile, with maximum value of 0.3 % on the bottom of the surface 1. This values decreased in the upper area of the block side. Vertical compressive strain were 2-3 times higher on the surface 1, when compared to the surface 2, with maximum values of 0.7 % located on the bottom of the surface 1, and 0.3 % on the bottom of the surface 2. Resin block models could be used for determination of strain distribution under axially loaded implants. Greatest strain concentration were located under the implants apex, in the bottom area of the block. It was concluded that, in this region, strain values decreased linearly with increase of distance from the implants surface.",
publisher = "Elsevier Science Bv, Amsterdam",
journal = "21st European Conference on Fracture, (ECF21)",
title = "Analysis of the effect of implant distance from the surrounding structure, in the PMMA block model",
volume = "2",
pages = "1260-1265",
doi = "10.1016/j.prostr.2016.06.161"
}
Mitrović, N., Tanasić, I., Šarac, D., Milošević, M., Misković, Ž., Tihaček-Šojić, L.,& Sedmak, A.. (2016). Analysis of the effect of implant distance from the surrounding structure, in the PMMA block model. in 21st European Conference on Fracture, (ECF21)
Elsevier Science Bv, Amsterdam., 2, 1260-1265.
https://doi.org/10.1016/j.prostr.2016.06.161
Mitrović N, Tanasić I, Šarac D, Milošević M, Misković Ž, Tihaček-Šojić L, Sedmak A. Analysis of the effect of implant distance from the surrounding structure, in the PMMA block model. in 21st European Conference on Fracture, (ECF21). 2016;2:1260-1265.
doi:10.1016/j.prostr.2016.06.161 .
Mitrović, Nenad, Tanasić, Ivan, Šarac, Dušan, Milošević, Miloš, Misković, Žarko, Tihaček-Šojić, Ljiljana, Sedmak, Aleksandar, "Analysis of the effect of implant distance from the surrounding structure, in the PMMA block model" in 21st European Conference on Fracture, (ECF21), 2 (2016):1260-1265,
https://doi.org/10.1016/j.prostr.2016.06.161 . .
1
2
3

Association Between Dentition Status and Malnutrition Risk in Serbian Elders

Tanasić, Ivan; Radaković, Tijana; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra; Soldatović, Ivan

(Quintessence Publishing Co Inc, Hanover Park, 2016)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Radaković, Tijana
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
AU  - Soldatović, Ivan
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2084
AB  - Purpose: The aim of this study was to find the correlation between the number, type, and placement of symmetric functional tooth units and the nutritional status using body mass index (BMI) and Mini Nutritional Assessment (MNA) in patients with both maxillary and mandibular removable partial dentures. Materials and Methods: A randomized study was conducted at the Clinic for Prosthodontics, School of Dentistry, University of Belgrade, Serbia, followed by determination of number of functional tooth units. After insertion of the prostheses, the nutritional status was assessed, using BMI and MNA form. Nutritional status was reviewed 12 months after prosthetic treatment. Number of teeth and age were analyzed using analysis of variance and t test. For other variables such as BMI baseline, BMI follow-up, MNA baseline, MNA follow-up, change in BMI, and change in MNA, Kruskal-Wallis Test or Mann-Whitney Test were used. Results: The results on the MNA changes showed that patients with symmetric natural functional tooth units had significantly higher values (2.9 +/- 0.8) compared with patients without natural functional tooth units (1.9 +/- 0.6) or with asymmetric natural functional tooth units (1.6 +/- 0.4). Patients with asymmetric artificial functional tooth units had significantly lower change in MNA (1.9 +/- 0.4) than those with symmetric artificial functional tooth units (2.6 +/- 0.9). Conclusion: The findings of this study suggest that adequate rehabilitation with symmetric positioning of the functional tooth units can improve the nutritional status of partially edentulous patients.
PB  - Quintessence Publishing Co Inc, Hanover Park
T2  - International Journal of Prosthodontics
T1  - Association Between Dentition Status and Malnutrition Risk in Serbian Elders
VL  - 29
IS  - 5
SP  - 484
EP  - 486
DO  - 10.11607/ijp.4752
ER  - 
@article{
author = "Tanasić, Ivan and Radaković, Tijana and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra and Soldatović, Ivan",
year = "2016",
abstract = "Purpose: The aim of this study was to find the correlation between the number, type, and placement of symmetric functional tooth units and the nutritional status using body mass index (BMI) and Mini Nutritional Assessment (MNA) in patients with both maxillary and mandibular removable partial dentures. Materials and Methods: A randomized study was conducted at the Clinic for Prosthodontics, School of Dentistry, University of Belgrade, Serbia, followed by determination of number of functional tooth units. After insertion of the prostheses, the nutritional status was assessed, using BMI and MNA form. Nutritional status was reviewed 12 months after prosthetic treatment. Number of teeth and age were analyzed using analysis of variance and t test. For other variables such as BMI baseline, BMI follow-up, MNA baseline, MNA follow-up, change in BMI, and change in MNA, Kruskal-Wallis Test or Mann-Whitney Test were used. Results: The results on the MNA changes showed that patients with symmetric natural functional tooth units had significantly higher values (2.9 +/- 0.8) compared with patients without natural functional tooth units (1.9 +/- 0.6) or with asymmetric natural functional tooth units (1.6 +/- 0.4). Patients with asymmetric artificial functional tooth units had significantly lower change in MNA (1.9 +/- 0.4) than those with symmetric artificial functional tooth units (2.6 +/- 0.9). Conclusion: The findings of this study suggest that adequate rehabilitation with symmetric positioning of the functional tooth units can improve the nutritional status of partially edentulous patients.",
publisher = "Quintessence Publishing Co Inc, Hanover Park",
journal = "International Journal of Prosthodontics",
title = "Association Between Dentition Status and Malnutrition Risk in Serbian Elders",
volume = "29",
number = "5",
pages = "484-486",
doi = "10.11607/ijp.4752"
}
Tanasić, I., Radaković, T., Tihaček-Šojić, L., Milić-Lemić, A.,& Soldatović, I.. (2016). Association Between Dentition Status and Malnutrition Risk in Serbian Elders. in International Journal of Prosthodontics
Quintessence Publishing Co Inc, Hanover Park., 29(5), 484-486.
https://doi.org/10.11607/ijp.4752
Tanasić I, Radaković T, Tihaček-Šojić L, Milić-Lemić A, Soldatović I. Association Between Dentition Status and Malnutrition Risk in Serbian Elders. in International Journal of Prosthodontics. 2016;29(5):484-486.
doi:10.11607/ijp.4752 .
Tanasić, Ivan, Radaković, Tijana, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, Soldatović, Ivan, "Association Between Dentition Status and Malnutrition Risk in Serbian Elders" in International Journal of Prosthodontics, 29, no. 5 (2016):484-486,
https://doi.org/10.11607/ijp.4752 . .
1
3
2
4

Digital Image Correlation Analysis of Vertically Loaded Cylindrical Ti-Implants With Straight and Angled Abutments

Tanasić, Ivan; Šarac, Dušan; Mitrović, Nenad; Tihaček-Šojić, Ljiljana; Misković, Žarko; Milić-Lemić, Aleksandra; Milošević, Miloš

(Springer, New York, 2016)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Šarac, Dušan
AU  - Mitrović, Nenad
AU  - Tihaček-Šojić, Ljiljana
AU  - Misković, Žarko
AU  - Milić-Lemić, Aleksandra
AU  - Milošević, Miloš
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2071
AB  - The purpose of this study was to investigate the influence of the abutment angulation upon the strain distribution pattern for the vertical loading situation by means of the digital image correlation (DIC) method. In addition, to find the correlation between acrylic-layer thickness around implant body and surfaces strain induced by vertical loads. Two types of samples consisted of the Straumann (R) cylindrical dental implant system (4x10mm) with the SLActive (R) surface and the poly-methyl-methacrylate were used in this study. For strain analysis, the DIC system was used, manufacturer GOM. The optical deformation measurement system consists of special set of stereo cameras and lenses, and ARAMIS software (6.2.0, Braunschweig, Germany). Maximum von Mises strain was 0.30% in the sample with the straight abutment and 0.50% in the sample with the angled abutment. Minimum strain measured by Aramis was 0.01%, detected in the 6mm surface layer of the sample with straight abutment. According to results obtained by Aramis data processing, the 4mm surface layer indicated greater overall strain in apical direction with the strains of 0.18-0.50%, depending on the force intensity. Higher strain was noticed in the thinner surface layers. The angulated abutment induced higher strain in both surface layers than the straight abutment did.
PB  - Springer, New York
T2  - Experimental Techniques
T1  - Digital Image Correlation Analysis of Vertically Loaded Cylindrical Ti-Implants With Straight and Angled Abutments
VL  - 40
IS  - 4
SP  - 1227
EP  - 1233
DO  - 10.1007/s40799-016-0120-y
ER  - 
@article{
author = "Tanasić, Ivan and Šarac, Dušan and Mitrović, Nenad and Tihaček-Šojić, Ljiljana and Misković, Žarko and Milić-Lemić, Aleksandra and Milošević, Miloš",
year = "2016",
abstract = "The purpose of this study was to investigate the influence of the abutment angulation upon the strain distribution pattern for the vertical loading situation by means of the digital image correlation (DIC) method. In addition, to find the correlation between acrylic-layer thickness around implant body and surfaces strain induced by vertical loads. Two types of samples consisted of the Straumann (R) cylindrical dental implant system (4x10mm) with the SLActive (R) surface and the poly-methyl-methacrylate were used in this study. For strain analysis, the DIC system was used, manufacturer GOM. The optical deformation measurement system consists of special set of stereo cameras and lenses, and ARAMIS software (6.2.0, Braunschweig, Germany). Maximum von Mises strain was 0.30% in the sample with the straight abutment and 0.50% in the sample with the angled abutment. Minimum strain measured by Aramis was 0.01%, detected in the 6mm surface layer of the sample with straight abutment. According to results obtained by Aramis data processing, the 4mm surface layer indicated greater overall strain in apical direction with the strains of 0.18-0.50%, depending on the force intensity. Higher strain was noticed in the thinner surface layers. The angulated abutment induced higher strain in both surface layers than the straight abutment did.",
publisher = "Springer, New York",
journal = "Experimental Techniques",
title = "Digital Image Correlation Analysis of Vertically Loaded Cylindrical Ti-Implants With Straight and Angled Abutments",
volume = "40",
number = "4",
pages = "1227-1233",
doi = "10.1007/s40799-016-0120-y"
}
Tanasić, I., Šarac, D., Mitrović, N., Tihaček-Šojić, L., Misković, Ž., Milić-Lemić, A.,& Milošević, M.. (2016). Digital Image Correlation Analysis of Vertically Loaded Cylindrical Ti-Implants With Straight and Angled Abutments. in Experimental Techniques
Springer, New York., 40(4), 1227-1233.
https://doi.org/10.1007/s40799-016-0120-y
Tanasić I, Šarac D, Mitrović N, Tihaček-Šojić L, Misković Ž, Milić-Lemić A, Milošević M. Digital Image Correlation Analysis of Vertically Loaded Cylindrical Ti-Implants With Straight and Angled Abutments. in Experimental Techniques. 2016;40(4):1227-1233.
doi:10.1007/s40799-016-0120-y .
Tanasić, Ivan, Šarac, Dušan, Mitrović, Nenad, Tihaček-Šojić, Ljiljana, Misković, Žarko, Milić-Lemić, Aleksandra, Milošević, Miloš, "Digital Image Correlation Analysis of Vertically Loaded Cylindrical Ti-Implants With Straight and Angled Abutments" in Experimental Techniques, 40, no. 4 (2016):1227-1233,
https://doi.org/10.1007/s40799-016-0120-y . .
5
2
4

An attempt to create a standardized (reference) model for experimental investigations on implant's sample

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Mitrović, Nenad; Milić-Lemić, Aleksandra; Vukadinović, Miroslav; Marković, Aleksa; Milošević, Miloš

(Elsevier Sci Ltd, Oxford, 2015)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Mitrović, Nenad
AU  - Milić-Lemić, Aleksandra
AU  - Vukadinović, Miroslav
AU  - Marković, Aleksa
AU  - Milošević, Miloš
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1965
AB  - The aim of this study was to determine, evaluate and measure strain of vertically loaded implant using the digital image correlation method. The Straumann (R) dental implant system with the SLActive (R) surface was used in this study. Implant was immersed in poly-methyl-methacrylate during his hardening process. After preparation procedure a sample of implant and poly-methyl-methacrylate was obtained. This sample was loaded using external load from 0 to 400 N. Maximum strain in the 4 mm surface layer was 0.30% whereas maximum strain in the 6 mm surface layer (opposite side) was 0.20%, detected in the marginal and apical part of implant-poly-methyl-methacrylate sample. Minimum strain measured by Aramis software was 0.01%, detected in the 4 mm surface layer. According to results obtained by Aramis data processing, the 4 mm surface layer indicated higher overall strain in apical direction with the strains of 0.18-0.21%. Increasing the load did not affect the value of maximum strain however, higher load influenced the overall strain concentration increased especially in marginal and apical part of the sample surfaces that surrounded lateral sides of implant body.
PB  - Elsevier Sci Ltd, Oxford
T2  - Measurement
T1  - An attempt to create a standardized (reference) model for experimental investigations on implant's sample
VL  - 72
SP  - 37
EP  - 42
DO  - 10.1016/j.measurement.2015.04.029
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Mitrović, Nenad and Milić-Lemić, Aleksandra and Vukadinović, Miroslav and Marković, Aleksa and Milošević, Miloš",
year = "2015",
abstract = "The aim of this study was to determine, evaluate and measure strain of vertically loaded implant using the digital image correlation method. The Straumann (R) dental implant system with the SLActive (R) surface was used in this study. Implant was immersed in poly-methyl-methacrylate during his hardening process. After preparation procedure a sample of implant and poly-methyl-methacrylate was obtained. This sample was loaded using external load from 0 to 400 N. Maximum strain in the 4 mm surface layer was 0.30% whereas maximum strain in the 6 mm surface layer (opposite side) was 0.20%, detected in the marginal and apical part of implant-poly-methyl-methacrylate sample. Minimum strain measured by Aramis software was 0.01%, detected in the 4 mm surface layer. According to results obtained by Aramis data processing, the 4 mm surface layer indicated higher overall strain in apical direction with the strains of 0.18-0.21%. Increasing the load did not affect the value of maximum strain however, higher load influenced the overall strain concentration increased especially in marginal and apical part of the sample surfaces that surrounded lateral sides of implant body.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Measurement",
title = "An attempt to create a standardized (reference) model for experimental investigations on implant's sample",
volume = "72",
pages = "37-42",
doi = "10.1016/j.measurement.2015.04.029"
}
Tanasić, I., Tihaček-Šojić, L., Mitrović, N., Milić-Lemić, A., Vukadinović, M., Marković, A.,& Milošević, M.. (2015). An attempt to create a standardized (reference) model for experimental investigations on implant's sample. in Measurement
Elsevier Sci Ltd, Oxford., 72, 37-42.
https://doi.org/10.1016/j.measurement.2015.04.029
Tanasić I, Tihaček-Šojić L, Mitrović N, Milić-Lemić A, Vukadinović M, Marković A, Milošević M. An attempt to create a standardized (reference) model for experimental investigations on implant's sample. in Measurement. 2015;72:37-42.
doi:10.1016/j.measurement.2015.04.029 .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Mitrović, Nenad, Milić-Lemić, Aleksandra, Vukadinović, Miroslav, Marković, Aleksa, Milošević, Miloš, "An attempt to create a standardized (reference) model for experimental investigations on implant's sample" in Measurement, 72 (2015):37-42,
https://doi.org/10.1016/j.measurement.2015.04.029 . .
13
9
17

Prevalence and Clinical Effects of Certain Therapy Concepts among Partially Edentulous Serbian Elderly

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra

(Wiley-Blackwell, Hoboken, 2015)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2004
AB  - Purpose: This study was conducted to identify the prevalence of partially edentulous individuals in Serbia and to identify prosthodontic treatment used for their rehabilitation as well as to compare prosthodontic treatment concepts among Serbian elderly participants who answered closed-format questionnaires. Materials and Methods: The study was conducted at the Clinic for Dental Prosthetics, University of Belgrade, Military Medical Academy and the Department of Prosthodontics of Home Centre Belgrade; the study consisted of 120 participants. A questionnaire with closed-format questions regarding the influence of applied therapy concepts for participants with Kennedy Class I partial edentulism was created. Statistical software SPSS 11.5 was used for data analysis. Chi-square tests were performed, and p-values were calculated for each parameter. Results: A total of 1081 people were examined; 730 participants were partially edentulous in at least one jaw. Five hundred forty-one participants wore Kennedy Class I maxillary or mandibular removable partial dentures (RPDs). Ninety percent of the patients were restored with RPDs; 60% of participants were unrestored, had shortened dental arches, and requested alternative therapeutic solutions. Significantly lower needs for new treatments were identified in participants with fixed dental prostheses (7.5%). Conclusions: Kennedy Class I was the most common type of partial edentulism among Serbian elderly, usually treated with RPDs. Elderly participants with the applied shortened dental arch and RPD therapy concepts requested alternative therapeutic solutions more often than those rehabilitated with fixed partial dentures.
PB  - Wiley-Blackwell, Hoboken
T2  - Journal of Prosthodontics-Implant Esthetic & Reconstructive Dentistry
T1  - Prevalence and Clinical Effects of Certain Therapy Concepts among Partially Edentulous Serbian Elderly
VL  - 24
IS  - 8
SP  - 610
EP  - 614
DO  - 10.1111/jopr.12261
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra",
year = "2015",
abstract = "Purpose: This study was conducted to identify the prevalence of partially edentulous individuals in Serbia and to identify prosthodontic treatment used for their rehabilitation as well as to compare prosthodontic treatment concepts among Serbian elderly participants who answered closed-format questionnaires. Materials and Methods: The study was conducted at the Clinic for Dental Prosthetics, University of Belgrade, Military Medical Academy and the Department of Prosthodontics of Home Centre Belgrade; the study consisted of 120 participants. A questionnaire with closed-format questions regarding the influence of applied therapy concepts for participants with Kennedy Class I partial edentulism was created. Statistical software SPSS 11.5 was used for data analysis. Chi-square tests were performed, and p-values were calculated for each parameter. Results: A total of 1081 people were examined; 730 participants were partially edentulous in at least one jaw. Five hundred forty-one participants wore Kennedy Class I maxillary or mandibular removable partial dentures (RPDs). Ninety percent of the patients were restored with RPDs; 60% of participants were unrestored, had shortened dental arches, and requested alternative therapeutic solutions. Significantly lower needs for new treatments were identified in participants with fixed dental prostheses (7.5%). Conclusions: Kennedy Class I was the most common type of partial edentulism among Serbian elderly, usually treated with RPDs. Elderly participants with the applied shortened dental arch and RPD therapy concepts requested alternative therapeutic solutions more often than those rehabilitated with fixed partial dentures.",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Journal of Prosthodontics-Implant Esthetic & Reconstructive Dentistry",
title = "Prevalence and Clinical Effects of Certain Therapy Concepts among Partially Edentulous Serbian Elderly",
volume = "24",
number = "8",
pages = "610-614",
doi = "10.1111/jopr.12261"
}
Tanasić, I., Tihaček-Šojić, L.,& Milić-Lemić, A.. (2015). Prevalence and Clinical Effects of Certain Therapy Concepts among Partially Edentulous Serbian Elderly. in Journal of Prosthodontics-Implant Esthetic & Reconstructive Dentistry
Wiley-Blackwell, Hoboken., 24(8), 610-614.
https://doi.org/10.1111/jopr.12261
Tanasić I, Tihaček-Šojić L, Milić-Lemić A. Prevalence and Clinical Effects of Certain Therapy Concepts among Partially Edentulous Serbian Elderly. in Journal of Prosthodontics-Implant Esthetic & Reconstructive Dentistry. 2015;24(8):610-614.
doi:10.1111/jopr.12261 .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, "Prevalence and Clinical Effects of Certain Therapy Concepts among Partially Edentulous Serbian Elderly" in Journal of Prosthodontics-Implant Esthetic & Reconstructive Dentistry, 24, no. 8 (2015):610-614,
https://doi.org/10.1111/jopr.12261 . .
7
2
3

Finite Element Analysis of Compressive Stress and Strain of Different Implant Forms During Vertical Loading

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra

(Quintessenz Verlags GmbH, 2014)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1938
AB  - This study analyzed the influence of platform switching on the stress/strain distribution of vertically loaded implants. Employing finite element analysis, the aim of this study was to determine the distribution of stresses and strains generated by a simulated vertical load on different implant models positioned in the molar region with respect to changes of implant design and biomechanics. Two different implant designs, one with and one without platform switching, with the same length (11.5 mm) and diameter of (3.80 mm) were analyzed. Both virtual implant-bone models were subjected to a load of 500 N. The results showed that the maximum stress/strain in implant-bone samples was located in the area of the implant neck, with stress/strain values decreasing in the apical direction. It was found that the implant design with platform switching developed lower stresses and strains than the implant design without platform switching.
PB  - Quintessenz Verlags GmbH
T2  - International Journal of Computerized Dentistry
T1  - Finite Element Analysis of Compressive Stress and Strain of Different Implant Forms During Vertical Loading
VL  - 17
IS  - 2
SP  - 125
EP  - 133
UR  - https://hdl.handle.net/21.15107/rcub_smile_1938
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra",
year = "2014",
abstract = "This study analyzed the influence of platform switching on the stress/strain distribution of vertically loaded implants. Employing finite element analysis, the aim of this study was to determine the distribution of stresses and strains generated by a simulated vertical load on different implant models positioned in the molar region with respect to changes of implant design and biomechanics. Two different implant designs, one with and one without platform switching, with the same length (11.5 mm) and diameter of (3.80 mm) were analyzed. Both virtual implant-bone models were subjected to a load of 500 N. The results showed that the maximum stress/strain in implant-bone samples was located in the area of the implant neck, with stress/strain values decreasing in the apical direction. It was found that the implant design with platform switching developed lower stresses and strains than the implant design without platform switching.",
publisher = "Quintessenz Verlags GmbH",
journal = "International Journal of Computerized Dentistry",
title = "Finite Element Analysis of Compressive Stress and Strain of Different Implant Forms During Vertical Loading",
volume = "17",
number = "2",
pages = "125-133",
url = "https://hdl.handle.net/21.15107/rcub_smile_1938"
}
Tanasić, I., Tihaček-Šojić, L.,& Milić-Lemić, A.. (2014). Finite Element Analysis of Compressive Stress and Strain of Different Implant Forms During Vertical Loading. in International Journal of Computerized Dentistry
Quintessenz Verlags GmbH., 17(2), 125-133.
https://hdl.handle.net/21.15107/rcub_smile_1938
Tanasić I, Tihaček-Šojić L, Milić-Lemić A. Finite Element Analysis of Compressive Stress and Strain of Different Implant Forms During Vertical Loading. in International Journal of Computerized Dentistry. 2014;17(2):125-133.
https://hdl.handle.net/21.15107/rcub_smile_1938 .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, "Finite Element Analysis of Compressive Stress and Strain of Different Implant Forms During Vertical Loading" in International Journal of Computerized Dentistry, 17, no. 2 (2014):125-133,
https://hdl.handle.net/21.15107/rcub_smile_1938 .
6
8

Biomechanical interactions between bone and metal-ceramic bridges composed of different types of non-noble alloys under vertical loading conditions

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra

(Institute of Metals Technology, 2014)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1922
AB  - The purpose of this study was to compare the mechanical properties of three metal-ceramic bridges of different types of dental alloys and to present and evaluate the possible biomechanical interactions between a marginal bone and metal-ceramic bridges during vertical loading. The research was done as an experimental study. A mandible with an intact anterior region was used. The preparation of the remaining teeth for receiving three types of porcelain-fused-to-metal (PFM) restorations was performed. Vita VMK 95 was used for all three metal-ceramic restorations. These three metal-ceramic bridges composed of different alloys, nickel and non-nickel, served as different models: the Niadur-nickelferous model, the Wiron 99-nickel model and the Wirobond C-cobalt-chrome model. The maximum compressive strain of 5% for all three virtual models is observed in the region of central incisors. The Niadur model has the lowest mean strain (2.62%) in comparison with the other two models. The mean strain of Wiron 99 is lower, by 0.10%, than the mean strain of the Wirobond model. Biomechanical behavior of the presented models caused by the vertical-loading conditions is explained as an interaction between the marginal bone and the metal-ceramic bridges. All of them, nickel and non-nickel models, indicate a similar strain (deformation) distribution; however, from the biomechanical perspective, Niadur is more favorable than the other two materials.
PB  - Institute of Metals Technology
T2  - Materiali in Tehnologije
T1  - Biomechanical interactions between bone and metal-ceramic bridges composed of different types of non-noble alloys under vertical loading conditions
VL  - 48
IS  - 3
SP  - 337
EP  - 341
UR  - https://hdl.handle.net/21.15107/rcub_smile_1922
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra",
year = "2014",
abstract = "The purpose of this study was to compare the mechanical properties of three metal-ceramic bridges of different types of dental alloys and to present and evaluate the possible biomechanical interactions between a marginal bone and metal-ceramic bridges during vertical loading. The research was done as an experimental study. A mandible with an intact anterior region was used. The preparation of the remaining teeth for receiving three types of porcelain-fused-to-metal (PFM) restorations was performed. Vita VMK 95 was used for all three metal-ceramic restorations. These three metal-ceramic bridges composed of different alloys, nickel and non-nickel, served as different models: the Niadur-nickelferous model, the Wiron 99-nickel model and the Wirobond C-cobalt-chrome model. The maximum compressive strain of 5% for all three virtual models is observed in the region of central incisors. The Niadur model has the lowest mean strain (2.62%) in comparison with the other two models. The mean strain of Wiron 99 is lower, by 0.10%, than the mean strain of the Wirobond model. Biomechanical behavior of the presented models caused by the vertical-loading conditions is explained as an interaction between the marginal bone and the metal-ceramic bridges. All of them, nickel and non-nickel models, indicate a similar strain (deformation) distribution; however, from the biomechanical perspective, Niadur is more favorable than the other two materials.",
publisher = "Institute of Metals Technology",
journal = "Materiali in Tehnologije",
title = "Biomechanical interactions between bone and metal-ceramic bridges composed of different types of non-noble alloys under vertical loading conditions",
volume = "48",
number = "3",
pages = "337-341",
url = "https://hdl.handle.net/21.15107/rcub_smile_1922"
}
Tanasić, I., Tihaček-Šojić, L.,& Milić-Lemić, A.. (2014). Biomechanical interactions between bone and metal-ceramic bridges composed of different types of non-noble alloys under vertical loading conditions. in Materiali in Tehnologije
Institute of Metals Technology., 48(3), 337-341.
https://hdl.handle.net/21.15107/rcub_smile_1922
Tanasić I, Tihaček-Šojić L, Milić-Lemić A. Biomechanical interactions between bone and metal-ceramic bridges composed of different types of non-noble alloys under vertical loading conditions. in Materiali in Tehnologije. 2014;48(3):337-341.
https://hdl.handle.net/21.15107/rcub_smile_1922 .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, "Biomechanical interactions between bone and metal-ceramic bridges composed of different types of non-noble alloys under vertical loading conditions" in Materiali in Tehnologije, 48, no. 3 (2014):337-341,
https://hdl.handle.net/21.15107/rcub_smile_1922 .
3
3

Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method

Tanasić, Ivan; Milić-Lemić, Aleksandra; Tihaček-Šojić, Ljiljana; Stančić, Ivica; Mitrović, Nenad

(Springer Heidelberg, Heidelberg, 2012)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Milić-Lemić, Aleksandra
AU  - Tihaček-Šojić, Ljiljana
AU  - Stančić, Ivica
AU  - Mitrović, Nenad
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1733
AB  - It was the purpose of this study to determine and analyse strains in the bone of posterior mandible below the removable and fixed partial dentures using Digital Image Correlation Method. Dried mandible with shortened dental arch (Kennedy Class 1) was used in the experiment. The mandible model was prepared for accepting two types of restorations for bilaterally missing molars conventional therapy, and removable and fixed partial dentures were manufactured following standard prosthetic protocol. The models with prosthetic restorations placed in situ were subjected to loading of 50-300 N, and photographed using two digital cameras as part of the digital image correlation method equipment. Afterwards, the obtained data for strains within restored mandible during loading ciclus were analysed in the software Aramis and graphically presented. Percentage size of the mandible strains within the line section are from 0.14 to 0.19% for the removable partial denture experimental model and 0-0.14% for the fixed partial denture experimental model. The study has demonstrated that Digital Image Correlation method can be used to measure strain on the mandible surface and replacements during loading and that from biomechanical perspective both therapeutic modalities can be equally useful for the restoration of the mandible with bilaterally distal edentulous spaces.
PB  - Springer Heidelberg, Heidelberg
T2  - Biomechanics & Modeling in Mechanobiology
T1  - Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method
VL  - 11
IS  - 6
SP  - 751
EP  - 758
DO  - 10.1007/s10237-011-0348-5
ER  - 
@article{
author = "Tanasić, Ivan and Milić-Lemić, Aleksandra and Tihaček-Šojić, Ljiljana and Stančić, Ivica and Mitrović, Nenad",
year = "2012",
abstract = "It was the purpose of this study to determine and analyse strains in the bone of posterior mandible below the removable and fixed partial dentures using Digital Image Correlation Method. Dried mandible with shortened dental arch (Kennedy Class 1) was used in the experiment. The mandible model was prepared for accepting two types of restorations for bilaterally missing molars conventional therapy, and removable and fixed partial dentures were manufactured following standard prosthetic protocol. The models with prosthetic restorations placed in situ were subjected to loading of 50-300 N, and photographed using two digital cameras as part of the digital image correlation method equipment. Afterwards, the obtained data for strains within restored mandible during loading ciclus were analysed in the software Aramis and graphically presented. Percentage size of the mandible strains within the line section are from 0.14 to 0.19% for the removable partial denture experimental model and 0-0.14% for the fixed partial denture experimental model. The study has demonstrated that Digital Image Correlation method can be used to measure strain on the mandible surface and replacements during loading and that from biomechanical perspective both therapeutic modalities can be equally useful for the restoration of the mandible with bilaterally distal edentulous spaces.",
publisher = "Springer Heidelberg, Heidelberg",
journal = "Biomechanics & Modeling in Mechanobiology",
title = "Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method",
volume = "11",
number = "6",
pages = "751-758",
doi = "10.1007/s10237-011-0348-5"
}
Tanasić, I., Milić-Lemić, A., Tihaček-Šojić, L., Stančić, I.,& Mitrović, N.. (2012). Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method. in Biomechanics & Modeling in Mechanobiology
Springer Heidelberg, Heidelberg., 11(6), 751-758.
https://doi.org/10.1007/s10237-011-0348-5
Tanasić I, Milić-Lemić A, Tihaček-Šojić L, Stančić I, Mitrović N. Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method. in Biomechanics & Modeling in Mechanobiology. 2012;11(6):751-758.
doi:10.1007/s10237-011-0348-5 .
Tanasić, Ivan, Milić-Lemić, Aleksandra, Tihaček-Šojić, Ljiljana, Stančić, Ivica, Mitrović, Nenad, "Analysis of the compressive strain below the removable and fixed prosthesis in the posterior mandible using a digital image correlation method" in Biomechanics & Modeling in Mechanobiology, 11, no. 6 (2012):751-758,
https://doi.org/10.1007/s10237-011-0348-5 . .
22
21
28

Optical Aspect of Deformation Analysis in the Bone-Denture Complex

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra; Đurić, Marija; Mitrović, Nenad; Milošević, Miloš; Sedmak, Aleksandar

(Collegium Antropologicum, Zagreb, 2012)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
AU  - Đurić, Marija
AU  - Mitrović, Nenad
AU  - Milošević, Miloš
AU  - Sedmak, Aleksandar
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1732
AB  - The aim of this study was to register and measure any deformation of mandible models under load. The method for full field measurement of strain is done by using the ARAMIS three-dimensional image correlation system. The system uses two digital cameras that provide a synchronized stereo view of the specimen and the results show the complete strain field during the tests. The biggest deformation values were just under the working force of the biggest intensity 500 N, and for the region of the lower second premolar the deformation is 625 mu m. The following study is presented that highlight the use of stereometric measuring system for modern research. It is shown that this measuring methodology can capture the trends of the experiments.
PB  - Collegium Antropologicum, Zagreb
T2  - Collegium Antropologicum
T1  - Optical Aspect of Deformation Analysis in the Bone-Denture Complex
VL  - 36
IS  - 1
SP  - 173
EP  - 178
UR  - https://hdl.handle.net/21.15107/rcub_smile_1732
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra and Đurić, Marija and Mitrović, Nenad and Milošević, Miloš and Sedmak, Aleksandar",
year = "2012",
abstract = "The aim of this study was to register and measure any deformation of mandible models under load. The method for full field measurement of strain is done by using the ARAMIS three-dimensional image correlation system. The system uses two digital cameras that provide a synchronized stereo view of the specimen and the results show the complete strain field during the tests. The biggest deformation values were just under the working force of the biggest intensity 500 N, and for the region of the lower second premolar the deformation is 625 mu m. The following study is presented that highlight the use of stereometric measuring system for modern research. It is shown that this measuring methodology can capture the trends of the experiments.",
publisher = "Collegium Antropologicum, Zagreb",
journal = "Collegium Antropologicum",
title = "Optical Aspect of Deformation Analysis in the Bone-Denture Complex",
volume = "36",
number = "1",
pages = "173-178",
url = "https://hdl.handle.net/21.15107/rcub_smile_1732"
}
Tanasić, I., Tihaček-Šojić, L., Milić-Lemić, A., Đurić, M., Mitrović, N., Milošević, M.,& Sedmak, A.. (2012). Optical Aspect of Deformation Analysis in the Bone-Denture Complex. in Collegium Antropologicum
Collegium Antropologicum, Zagreb., 36(1), 173-178.
https://hdl.handle.net/21.15107/rcub_smile_1732
Tanasić I, Tihaček-Šojić L, Milić-Lemić A, Đurić M, Mitrović N, Milošević M, Sedmak A. Optical Aspect of Deformation Analysis in the Bone-Denture Complex. in Collegium Antropologicum. 2012;36(1):173-178.
https://hdl.handle.net/21.15107/rcub_smile_1732 .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, Đurić, Marija, Mitrović, Nenad, Milošević, Miloš, Sedmak, Aleksandar, "Optical Aspect of Deformation Analysis in the Bone-Denture Complex" in Collegium Antropologicum, 36, no. 1 (2012):173-178,
https://hdl.handle.net/21.15107/rcub_smile_1732 .
9

Biomechanical behavior of restored and unrestored mandible with shortened dental arch under vertical loading condition

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra

(Wroclaw Univ Technology, Wroclaw, 2012)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1711
AB  - The aim of this in vitro study was to investigate the strain distribution of the compressed mandible bone under the applied restoration-removable partial denture and to compare with the same but unrestored mandible under vertical (occlusal) load and to find out whether removable partial denture-restored or unrestored mandible causes greater strain effect on supporting tissue. Four mandible models were tested during loading for the purpose of strain measuring. Digital image correlation system (GOM - German Optical Measuring, Braunschweig, Germany), used for measuring strain consists of two digital cameras and software ARAMIS (6.2.0, Braunschweig, Germany). Remaining teeth suffer from greater strain in the mandible model without removable partial denture (7.5-10%). On the contrary, mandible with removable partial denture shows the maximum strain below the denture saddle (3.5%). However, it can be noticed that the marginal bone of the second lower praemolar in both experimental models is deformed whether the mandible model has (2.8%) or has not (10%) replacement. Within the limitations of this study the higher strain is observed in mandible model without replacement and the strain is limited locally, in the bone region that surrounds remaining teeth and mental foramen.
PB  - Wroclaw Univ Technology, Wroclaw
T2  - Acta of Bioengineering & Biomechanics
T1  - Biomechanical behavior of restored and unrestored mandible with shortened dental arch under vertical loading condition
VL  - 14
IS  - 4
SP  - 31
EP  - 36
DO  - 10.5277/abb120404
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra",
year = "2012",
abstract = "The aim of this in vitro study was to investigate the strain distribution of the compressed mandible bone under the applied restoration-removable partial denture and to compare with the same but unrestored mandible under vertical (occlusal) load and to find out whether removable partial denture-restored or unrestored mandible causes greater strain effect on supporting tissue. Four mandible models were tested during loading for the purpose of strain measuring. Digital image correlation system (GOM - German Optical Measuring, Braunschweig, Germany), used for measuring strain consists of two digital cameras and software ARAMIS (6.2.0, Braunschweig, Germany). Remaining teeth suffer from greater strain in the mandible model without removable partial denture (7.5-10%). On the contrary, mandible with removable partial denture shows the maximum strain below the denture saddle (3.5%). However, it can be noticed that the marginal bone of the second lower praemolar in both experimental models is deformed whether the mandible model has (2.8%) or has not (10%) replacement. Within the limitations of this study the higher strain is observed in mandible model without replacement and the strain is limited locally, in the bone region that surrounds remaining teeth and mental foramen.",
publisher = "Wroclaw Univ Technology, Wroclaw",
journal = "Acta of Bioengineering & Biomechanics",
title = "Biomechanical behavior of restored and unrestored mandible with shortened dental arch under vertical loading condition",
volume = "14",
number = "4",
pages = "31-36",
doi = "10.5277/abb120404"
}
Tanasić, I., Tihaček-Šojić, L.,& Milić-Lemić, A.. (2012). Biomechanical behavior of restored and unrestored mandible with shortened dental arch under vertical loading condition. in Acta of Bioengineering & Biomechanics
Wroclaw Univ Technology, Wroclaw., 14(4), 31-36.
https://doi.org/10.5277/abb120404
Tanasić I, Tihaček-Šojić L, Milić-Lemić A. Biomechanical behavior of restored and unrestored mandible with shortened dental arch under vertical loading condition. in Acta of Bioengineering & Biomechanics. 2012;14(4):31-36.
doi:10.5277/abb120404 .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, "Biomechanical behavior of restored and unrestored mandible with shortened dental arch under vertical loading condition" in Acta of Bioengineering & Biomechanics, 14, no. 4 (2012):31-36,
https://doi.org/10.5277/abb120404 . .
4
3

Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities

Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra; Tanasić, Ivan; Mitrović, Nenad; Milošević, Miloš; Petrović, Aleksandar

(Wiley, Hoboken, 2012)

TY  - JOUR
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
AU  - Tanasić, Ivan
AU  - Mitrović, Nenad
AU  - Milošević, Miloš
AU  - Petrović, Aleksandar
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1677
AB  - Background: Understanding of the biomechanical consequences of the stresses generated to the supporting bone during occlusal loading is significant for improving the design and clinical planning process in partial edentulism therapy. Objective: The aim of this study was to analyse the distribution of strain and displacement on the partially dentate lower jaw rehabilitated with an partial denture (RPD) and to compare it to the strain and displacement distribution on a partially dentate lower jaw rehabilitated with a cantilever fixed partial denture (FPD). Material and methods: The experimental models were a partially dentate mandible with full-arch PFM crowns and RPD and a partially dentate mandible rehabilitated with a full-arch cantilever FPD. Strains and displacement were measured using the Digital Image Correlation Method. Results: Displacement values of the first experimental model ranged from 0.31 to 0.54 mm with strains from 1.35 to 2.34%. Analysis of the second experimental model results showed displacement values from 0 to 0.34 mm, while strains were in the range of 0-1.40%. Conclusion: Higher displacements and strains of bone tissue were observed below the RPD, especially in the region of the distal abutment and distal portion of the free-end saddle. Strains within bone and the bone-denture contact area were mostly influenced by the teeth and denture vertical displacement.
PB  - Wiley, Hoboken
T2  - Gerodontology
T1  - Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities
VL  - 29
IS  - 2
SP  - E851
EP  - E857
DO  - 10.1111/j.1741-2358.2011.00572.x
ER  - 
@article{
author = "Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra and Tanasić, Ivan and Mitrović, Nenad and Milošević, Miloš and Petrović, Aleksandar",
year = "2012",
abstract = "Background: Understanding of the biomechanical consequences of the stresses generated to the supporting bone during occlusal loading is significant for improving the design and clinical planning process in partial edentulism therapy. Objective: The aim of this study was to analyse the distribution of strain and displacement on the partially dentate lower jaw rehabilitated with an partial denture (RPD) and to compare it to the strain and displacement distribution on a partially dentate lower jaw rehabilitated with a cantilever fixed partial denture (FPD). Material and methods: The experimental models were a partially dentate mandible with full-arch PFM crowns and RPD and a partially dentate mandible rehabilitated with a full-arch cantilever FPD. Strains and displacement were measured using the Digital Image Correlation Method. Results: Displacement values of the first experimental model ranged from 0.31 to 0.54 mm with strains from 1.35 to 2.34%. Analysis of the second experimental model results showed displacement values from 0 to 0.34 mm, while strains were in the range of 0-1.40%. Conclusion: Higher displacements and strains of bone tissue were observed below the RPD, especially in the region of the distal abutment and distal portion of the free-end saddle. Strains within bone and the bone-denture contact area were mostly influenced by the teeth and denture vertical displacement.",
publisher = "Wiley, Hoboken",
journal = "Gerodontology",
title = "Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities",
volume = "29",
number = "2",
pages = "E851-E857",
doi = "10.1111/j.1741-2358.2011.00572.x"
}
Tihaček-Šojić, L., Milić-Lemić, A., Tanasić, I., Mitrović, N., Milošević, M.,& Petrović, A.. (2012). Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities. in Gerodontology
Wiley, Hoboken., 29(2), E851-E857.
https://doi.org/10.1111/j.1741-2358.2011.00572.x
Tihaček-Šojić L, Milić-Lemić A, Tanasić I, Mitrović N, Milošević M, Petrović A. Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities. in Gerodontology. 2012;29(2):E851-E857.
doi:10.1111/j.1741-2358.2011.00572.x .
Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, Tanasić, Ivan, Mitrović, Nenad, Milošević, Miloš, Petrović, Aleksandar, "Compressive strains and displacement in a partially dentate lower jaw rehabilitated with two different treatment modalities" in Gerodontology, 29, no. 2 (2012):E851-E857,
https://doi.org/10.1111/j.1741-2358.2011.00572.x . .
17
9
26

Distribucija okluzalnih opterećenja u strukturama krezube donje vilice zbrinute različitim zubnim nadoknadama

Tanasić, Ivan

(Univerzitet u Beogradu, Stomatološki fakultet, 2011)

TY  - THES
AU  - Tanasić, Ivan
PY  - 2011
UR  - https://plus.sr.cobiss.net/opac7/bib/1024182158
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/509
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Distribucija okluzalnih opterećenja u strukturama krezube donje vilice zbrinute različitim zubnim nadoknadama
UR  - https://hdl.handle.net/21.15107/rcub_smile_509
ER  - 
@phdthesis{
author = "Tanasić, Ivan",
year = "2011",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Distribucija okluzalnih opterećenja u strukturama krezube donje vilice zbrinute različitim zubnim nadoknadama",
url = "https://hdl.handle.net/21.15107/rcub_smile_509"
}
Tanasić, I.. (2011). Distribucija okluzalnih opterećenja u strukturama krezube donje vilice zbrinute različitim zubnim nadoknadama. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_509
Tanasić I. Distribucija okluzalnih opterećenja u strukturama krezube donje vilice zbrinute različitim zubnim nadoknadama. 2011;.
https://hdl.handle.net/21.15107/rcub_smile_509 .
Tanasić, Ivan, "Distribucija okluzalnih opterećenja u strukturama krezube donje vilice zbrinute različitim zubnim nadoknadama" (2011),
https://hdl.handle.net/21.15107/rcub_smile_509 .

Optical metrology analysis of the lower jaw deformations

Tanasić, Ivan; Tihaček-Šojić, Ljiljana; Milić-Lemić, Aleksandra

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2011)

TY  - JOUR
AU  - Tanasić, Ivan
AU  - Tihaček-Šojić, Ljiljana
AU  - Milić-Lemić, Aleksandra
PY  - 2011
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1650
AB  - Background/Aim. New optical stereometric methods based on both contact and noncontact mechanisms for displacement measurement have become common methods in biomechanical behavior research of biomaterials, bone and soft tissue. The aim of this study was to register and measure possible deformations of the lower jaw (mandible) with the intact dental arch using optical metrology method. Methods. The system for full field measurement of deformations (strains) comprised of two digital cameras for a synchronized stereoview of the specimen, and the Aramis software. Results. The maximum mandibular bone strains were measured in the regions of the lower first premolar and the lower second molar. In the action force of 500 N simulated in the region of the first lower premolar the intensity of deformation was 86 μm. The value of maximum strain in the bone around the molars was 24 μm for the force of 500 N acting on the second lower molar. When it comes to premolars, 3-5 times stronger deformation was observed in the region of the first lower premolar, compared to the deformation values of the second lower premolar area. Conclusion. Under loading of the applied forces the measured strains were in the elastic deformation area, meanning that the dependence of force and deformity is linear. The highest values of strain measurements obtained by the optical method were found in the jaw bone tissue around the loading teeth, and the bony regions of the triangle and mental region. According to the obtained results from the Aramis processing software it can be concluded that this method is applicable in a variety of biomedical research.
AB  - Uvod/Cilj. Nove optičke stereometrijske metode koje se zasnivaju na kontaktnim i nekontaktnim mehanizmima za merenje zapremine postaju uobičajene metode u istraživanju biomehaničkog ponašanja biomaterijala, koštanog i mekog tkiva. Cilj ove studije bio je da se optičkom metodom merenja registruju i izmere eventualne deformacije koštanog fundamenta donje vilice sa intaktnim zubnim nizom i da se, ujedno, prikažu mogućnosti primene optičke metrologije u istraživanjima u stomatologiji. Metode. Sistem za merenje deformacija ispitivane donje vilice sa intaktnim zubnim lukom obuhvatio je dve digitalne kamere koje obezbeđuju stereosinhronizovani prikaz primerka, i softver Aramis. Rezultati. Najveće deformacije koštanog tkiva donje vilice izmerene su u regionu donjeg prvog premolara i donjeg drugog molara. Pri delovanju sila od 500 N za region prvog donjeg premolara veličina deformacije bila je 86 μm. Vrednost maksimalne srednje deformacije u koštanom sistemu oko molara iznosila je 24 μm pri delovanju sile od 500 N na drugi donji molar. Kada su u pitanju premolari, 3-5 puta jače deformacije uočene su u regionu prvog donjeg premolara, nego u predelu drugog donjeg premolara. Zaključak. Prilikom delovanja primenjenih sila deformacije se nalaze u elastičnom deformacionom polju, a međusobna zavisnost sile i deformacije ima linearan karakter. Najveće vrednosti deformacija dobijene optičkom metodom merenja registruju se u koštanom tkivu donje vilice koja je u neposrednom kontaktu sa zubima koji se opterećuju, kao i u koštanim regionima zakutnjačkog trougla i bradnog (mentalnog) otvora. Na osnovu analize rezultata dobijenih primenom softvera Aramis može se reći da postoje mogućnosti primene ove metode u različitim biomedicinskim istraživanjima.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Optical metrology analysis of the lower jaw deformations
T1  - Analiza deformacija donje vilice optičkom metrologijom
VL  - 68
IS  - 4
SP  - 336
EP  - 340
DO  - 10.2298/VSP1104336T
ER  - 
@article{
author = "Tanasić, Ivan and Tihaček-Šojić, Ljiljana and Milić-Lemić, Aleksandra",
year = "2011",
abstract = "Background/Aim. New optical stereometric methods based on both contact and noncontact mechanisms for displacement measurement have become common methods in biomechanical behavior research of biomaterials, bone and soft tissue. The aim of this study was to register and measure possible deformations of the lower jaw (mandible) with the intact dental arch using optical metrology method. Methods. The system for full field measurement of deformations (strains) comprised of two digital cameras for a synchronized stereoview of the specimen, and the Aramis software. Results. The maximum mandibular bone strains were measured in the regions of the lower first premolar and the lower second molar. In the action force of 500 N simulated in the region of the first lower premolar the intensity of deformation was 86 μm. The value of maximum strain in the bone around the molars was 24 μm for the force of 500 N acting on the second lower molar. When it comes to premolars, 3-5 times stronger deformation was observed in the region of the first lower premolar, compared to the deformation values of the second lower premolar area. Conclusion. Under loading of the applied forces the measured strains were in the elastic deformation area, meanning that the dependence of force and deformity is linear. The highest values of strain measurements obtained by the optical method were found in the jaw bone tissue around the loading teeth, and the bony regions of the triangle and mental region. According to the obtained results from the Aramis processing software it can be concluded that this method is applicable in a variety of biomedical research., Uvod/Cilj. Nove optičke stereometrijske metode koje se zasnivaju na kontaktnim i nekontaktnim mehanizmima za merenje zapremine postaju uobičajene metode u istraživanju biomehaničkog ponašanja biomaterijala, koštanog i mekog tkiva. Cilj ove studije bio je da se optičkom metodom merenja registruju i izmere eventualne deformacije koštanog fundamenta donje vilice sa intaktnim zubnim nizom i da se, ujedno, prikažu mogućnosti primene optičke metrologije u istraživanjima u stomatologiji. Metode. Sistem za merenje deformacija ispitivane donje vilice sa intaktnim zubnim lukom obuhvatio je dve digitalne kamere koje obezbeđuju stereosinhronizovani prikaz primerka, i softver Aramis. Rezultati. Najveće deformacije koštanog tkiva donje vilice izmerene su u regionu donjeg prvog premolara i donjeg drugog molara. Pri delovanju sila od 500 N za region prvog donjeg premolara veličina deformacije bila je 86 μm. Vrednost maksimalne srednje deformacije u koštanom sistemu oko molara iznosila je 24 μm pri delovanju sile od 500 N na drugi donji molar. Kada su u pitanju premolari, 3-5 puta jače deformacije uočene su u regionu prvog donjeg premolara, nego u predelu drugog donjeg premolara. Zaključak. Prilikom delovanja primenjenih sila deformacije se nalaze u elastičnom deformacionom polju, a međusobna zavisnost sile i deformacije ima linearan karakter. Najveće vrednosti deformacija dobijene optičkom metodom merenja registruju se u koštanom tkivu donje vilice koja je u neposrednom kontaktu sa zubima koji se opterećuju, kao i u koštanim regionima zakutnjačkog trougla i bradnog (mentalnog) otvora. Na osnovu analize rezultata dobijenih primenom softvera Aramis može se reći da postoje mogućnosti primene ove metode u različitim biomedicinskim istraživanjima.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Optical metrology analysis of the lower jaw deformations, Analiza deformacija donje vilice optičkom metrologijom",
volume = "68",
number = "4",
pages = "336-340",
doi = "10.2298/VSP1104336T"
}
Tanasić, I., Tihaček-Šojić, L.,& Milić-Lemić, A.. (2011). Optical metrology analysis of the lower jaw deformations. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 68(4), 336-340.
https://doi.org/10.2298/VSP1104336T
Tanasić I, Tihaček-Šojić L, Milić-Lemić A. Optical metrology analysis of the lower jaw deformations. in Vojnosanitetski pregled. 2011;68(4):336-340.
doi:10.2298/VSP1104336T .
Tanasić, Ivan, Tihaček-Šojić, Ljiljana, Milić-Lemić, Aleksandra, "Optical metrology analysis of the lower jaw deformations" in Vojnosanitetski pregled, 68, no. 4 (2011):336-340,
https://doi.org/10.2298/VSP1104336T . .
2
5
4

3D strain analysis of restored lower jaw with total denture using optical measuring system

Milošević, M.; Mitrović, Nenad; Tanasić, Ivan; Ezdenci, Andrea; Tihaček-Šojić, Ljiljana; Maneski, Tasko; Colić, K.

(Scientific Society for Mechanical Engineering, 2011)

TY  - CONF
AU  - Milošević, M.
AU  - Mitrović, Nenad
AU  - Tanasić, Ivan
AU  - Ezdenci, Andrea
AU  - Tihaček-Šojić, Ljiljana
AU  - Maneski, Tasko
AU  - Colić, K.
PY  - 2011
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1646
PB  - Scientific Society for Mechanical Engineering
C3  - 28th Danubia - Adria - Symposium on Advances in Experimental Mechanics, DAS 2011
T1  - 3D strain analysis of restored lower jaw with total denture using optical measuring system
SP  - 101
EP  - 102
UR  - https://hdl.handle.net/21.15107/rcub_smile_1646
ER  - 
@conference{
author = "Milošević, M. and Mitrović, Nenad and Tanasić, Ivan and Ezdenci, Andrea and Tihaček-Šojić, Ljiljana and Maneski, Tasko and Colić, K.",
year = "2011",
publisher = "Scientific Society for Mechanical Engineering",
journal = "28th Danubia - Adria - Symposium on Advances in Experimental Mechanics, DAS 2011",
title = "3D strain analysis of restored lower jaw with total denture using optical measuring system",
pages = "101-102",
url = "https://hdl.handle.net/21.15107/rcub_smile_1646"
}
Milošević, M., Mitrović, N., Tanasić, I., Ezdenci, A., Tihaček-Šojić, L., Maneski, T.,& Colić, K.. (2011). 3D strain analysis of restored lower jaw with total denture using optical measuring system. in 28th Danubia - Adria - Symposium on Advances in Experimental Mechanics, DAS 2011
Scientific Society for Mechanical Engineering., 101-102.
https://hdl.handle.net/21.15107/rcub_smile_1646
Milošević M, Mitrović N, Tanasić I, Ezdenci A, Tihaček-Šojić L, Maneski T, Colić K. 3D strain analysis of restored lower jaw with total denture using optical measuring system. in 28th Danubia - Adria - Symposium on Advances in Experimental Mechanics, DAS 2011. 2011;:101-102.
https://hdl.handle.net/21.15107/rcub_smile_1646 .
Milošević, M., Mitrović, Nenad, Tanasić, Ivan, Ezdenci, Andrea, Tihaček-Šojić, Ljiljana, Maneski, Tasko, Colić, K., "3D strain analysis of restored lower jaw with total denture using optical measuring system" in 28th Danubia - Adria - Symposium on Advances in Experimental Mechanics, DAS 2011 (2011):101-102,
https://hdl.handle.net/21.15107/rcub_smile_1646 .