Čerče, Luka

Link to this page

Authority KeyName Variants
4c9526d1-e439-43e9-acf3-39db2bcffe14
  • Čerče, Luka (1)
Projects
No records found.

Author's Bibliography

Examination of scanner precision by analysing orthodontic parameters

Majstorović, Nemanja; Čerče, Luka; Kramar, Davorin; Soković, Mirko; Glišić, Branislav; Majstorović, Vidosav; Živković, Srđan

(Udruženje stomatologa Balkana, 2017)

TY  - JOUR
AU  - Majstorović, Nemanja
AU  - Čerče, Luka
AU  - Kramar, Davorin
AU  - Soković, Mirko
AU  - Glišić, Branislav
AU  - Majstorović, Vidosav
AU  - Živković, Srđan
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2244
AB  - Background: 3D modelling in orthodontics is becoming an increasingly widespread technique in practice. One of the significant questions already being asked is related to determining the precision of the scanner used for generating surfaces on a 3D model of the jaw. Materials and methods: This research was conducted by generating a set of identical 3D models on Atos optical 3D scanner and Lazak Scan laboratory scanner, which precision was established by measuring a set of orthodontic parameters (54 overall) in all three orthodontic planes. In this manner we explored their precision in space, since they are used for generating spatial models - 3D jaws. Results: There were significant differences between parameters scanned with Atos and Lazak Scan. The smallest difference was 0.017 mm, and the biggest 1.109 mm. Conclusion: This research reveals that both scanners (Atos and Lazak Scan), which belong to general purpose scanners, based on precision parameters can be used in orthodontics. Early analyses indicate that the reference scanner in terms of precision is Atos.
PB  - Udruženje stomatologa Balkana
T2  - Balkan Journal of Dental Medicine
T1  - Examination of scanner precision by analysing orthodontic parameters
VL  - 21
IS  - 1
SP  - 32
EP  - 43
DO  - 10.1515/bjdm-2017-0005
ER  - 
@article{
author = "Majstorović, Nemanja and Čerče, Luka and Kramar, Davorin and Soković, Mirko and Glišić, Branislav and Majstorović, Vidosav and Živković, Srđan",
year = "2017",
abstract = "Background: 3D modelling in orthodontics is becoming an increasingly widespread technique in practice. One of the significant questions already being asked is related to determining the precision of the scanner used for generating surfaces on a 3D model of the jaw. Materials and methods: This research was conducted by generating a set of identical 3D models on Atos optical 3D scanner and Lazak Scan laboratory scanner, which precision was established by measuring a set of orthodontic parameters (54 overall) in all three orthodontic planes. In this manner we explored their precision in space, since they are used for generating spatial models - 3D jaws. Results: There were significant differences between parameters scanned with Atos and Lazak Scan. The smallest difference was 0.017 mm, and the biggest 1.109 mm. Conclusion: This research reveals that both scanners (Atos and Lazak Scan), which belong to general purpose scanners, based on precision parameters can be used in orthodontics. Early analyses indicate that the reference scanner in terms of precision is Atos.",
publisher = "Udruženje stomatologa Balkana",
journal = "Balkan Journal of Dental Medicine",
title = "Examination of scanner precision by analysing orthodontic parameters",
volume = "21",
number = "1",
pages = "32-43",
doi = "10.1515/bjdm-2017-0005"
}
Majstorović, N., Čerče, L., Kramar, D., Soković, M., Glišić, B., Majstorović, V.,& Živković, S.. (2017). Examination of scanner precision by analysing orthodontic parameters. in Balkan Journal of Dental Medicine
Udruženje stomatologa Balkana., 21(1), 32-43.
https://doi.org/10.1515/bjdm-2017-0005
Majstorović N, Čerče L, Kramar D, Soković M, Glišić B, Majstorović V, Živković S. Examination of scanner precision by analysing orthodontic parameters. in Balkan Journal of Dental Medicine. 2017;21(1):32-43.
doi:10.1515/bjdm-2017-0005 .
Majstorović, Nemanja, Čerče, Luka, Kramar, Davorin, Soković, Mirko, Glišić, Branislav, Majstorović, Vidosav, Živković, Srđan, "Examination of scanner precision by analysing orthodontic parameters" in Balkan Journal of Dental Medicine, 21, no. 1 (2017):32-43,
https://doi.org/10.1515/bjdm-2017-0005 . .
2