Ignjatović, Snežana

Link to this page

Authority KeyName Variants
15809a80-9951-4e61-8faa-c3be8458b2ef
  • Ignjatović, Snežana (2)
Projects
No records found.

Author's Bibliography

Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study

Milanović, Ivana; Ivanović, Vladimir; Vujašković, Mirjana; Ignjatović, Snežana; Miletić, Vesna

(Wiley-Blackwell, Hoboken, 2015)

TY  - JOUR
AU  - Milanović, Ivana
AU  - Ivanović, Vladimir
AU  - Vujašković, Mirjana
AU  - Ignjatović, Snežana
AU  - Miletić, Vesna
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1974
AB  - This study aimed to compare the accuracy of three electronic apex locators (EALs), Raypex 5, Apex NRG and ProPex II, in locating the apical foramen (AF) in vivo. Thirty multi-rooted teeth were included in the study. Distances from the file tip to the radiographic apex from the buccal (R1) and mesial (R2) aspect were measured after extraction. The distance from the file tip to the AF (L) was measured microscopically. Raypex 5, Apex NRG and ProPex II were accurate to within +/- 0.5mm in 84.6%, 78.6% and 66.7% of cases, respectively. R1, R2 and L measurements between the EALs were not statistically different (P>0.05). R1 and L correlated positively (r(2)=0.817; P lt 0.001). There were no significant differences in all measurements between vital and non-vital root canals (P>0.05). There was no statistically significant difference between the EALs. There was a positive correlation between electronic and radiographic measurements when locating the AF.
PB  - Wiley-Blackwell, Hoboken
T2  - Australian Endodontic Journal
T1  - Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study
VL  - 41
IS  - 1
SP  - 35
EP  - 43
DO  - 10.1111/aej.12074
ER  - 
@article{
author = "Milanović, Ivana and Ivanović, Vladimir and Vujašković, Mirjana and Ignjatović, Snežana and Miletić, Vesna",
year = "2015",
abstract = "This study aimed to compare the accuracy of three electronic apex locators (EALs), Raypex 5, Apex NRG and ProPex II, in locating the apical foramen (AF) in vivo. Thirty multi-rooted teeth were included in the study. Distances from the file tip to the radiographic apex from the buccal (R1) and mesial (R2) aspect were measured after extraction. The distance from the file tip to the AF (L) was measured microscopically. Raypex 5, Apex NRG and ProPex II were accurate to within +/- 0.5mm in 84.6%, 78.6% and 66.7% of cases, respectively. R1, R2 and L measurements between the EALs were not statistically different (P>0.05). R1 and L correlated positively (r(2)=0.817; P lt 0.001). There were no significant differences in all measurements between vital and non-vital root canals (P>0.05). There was no statistically significant difference between the EALs. There was a positive correlation between electronic and radiographic measurements when locating the AF.",
publisher = "Wiley-Blackwell, Hoboken",
journal = "Australian Endodontic Journal",
title = "Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study",
volume = "41",
number = "1",
pages = "35-43",
doi = "10.1111/aej.12074"
}
Milanović, I., Ivanović, V., Vujašković, M., Ignjatović, S.,& Miletić, V.. (2015). Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study. in Australian Endodontic Journal
Wiley-Blackwell, Hoboken., 41(1), 35-43.
https://doi.org/10.1111/aej.12074
Milanović I, Ivanović V, Vujašković M, Ignjatović S, Miletić V. Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study. in Australian Endodontic Journal. 2015;41(1):35-43.
doi:10.1111/aej.12074 .
Milanović, Ivana, Ivanović, Vladimir, Vujašković, Mirjana, Ignjatović, Snežana, Miletić, Vesna, "Accuracy of three electronic apex locators in determining the apical foramen in multi-rooted teeth: Randomised clinical and laboratory study" in Australian Endodontic Journal, 41, no. 1 (2015):35-43,
https://doi.org/10.1111/aej.12074 . .
6
3
6

Uticaj različitih vrsta iriganasa na preciznost elektronskih apeks lokatora u in vitro uslovima

Ignjatović, Snežana

(Univerzitet u Beogradu, Stomatološki fakultet, 2013)

TY  - THES
AU  - Ignjatović, Snežana
PY  - 2013
UR  - https://plus.sr.cobiss.net/opac7/bib/1024214926
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/527
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Uticaj različitih vrsta iriganasa na preciznost elektronskih apeks lokatora u in vitro uslovima
UR  - https://hdl.handle.net/21.15107/rcub_smile_527
ER  - 
@mastersthesis{
author = "Ignjatović, Snežana",
year = "2013",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Uticaj različitih vrsta iriganasa na preciznost elektronskih apeks lokatora u in vitro uslovima",
url = "https://hdl.handle.net/21.15107/rcub_smile_527"
}
Ignjatović, S.. (2013). Uticaj različitih vrsta iriganasa na preciznost elektronskih apeks lokatora u in vitro uslovima. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_527
Ignjatović S. Uticaj različitih vrsta iriganasa na preciznost elektronskih apeks lokatora u in vitro uslovima. 2013;.
https://hdl.handle.net/21.15107/rcub_smile_527 .
Ignjatović, Snežana, "Uticaj različitih vrsta iriganasa na preciznost elektronskih apeks lokatora u in vitro uslovima" (2013),
https://hdl.handle.net/21.15107/rcub_smile_527 .