Jevremović, Danimir

Link to this page

Authority KeyName Variants
3e2f6848-aeca-4efa-8043-5786067542fb
  • Jevremović, Danimir (12)
Projects

Author's Bibliography

Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems

Trifković, Branka; Budak, Igor; Vukelić, Đorđe; Puškar, Tatjana; Jevremović, Danimir; Todorović, Aleksandar; Todorović, Ana; Poštić, Srđan

(Maejo University, 2017)

TY  - JOUR
AU  - Trifković, Branka
AU  - Budak, Igor
AU  - Vukelić, Đorđe
AU  - Puškar, Tatjana
AU  - Jevremović, Danimir
AU  - Todorović, Aleksandar
AU  - Todorović, Ana
AU  - Poštić, Srđan
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2257
AB  - The implementation of intraoral and extraoral computer-aided-design and computer-aided-manufacturing (CAD/CAM) systems in prosthetic dentistry has simplified the procedure, shortened the period of design and manufacture and improved accuracy and aesthetic properties of dental restorations. Three-dimensional (3D) digitisation has become an adequate replacement for conventional dental impressions. The market offers a variety of diverse optical intraoral and extraoral CAD/CAM systems equipped with digitisation devices that are based on different working principles. The main goal of this research is to determine whether precision and accuracy differ among optical digitisation devices. The research includes five high-end devices: Cerec AC, Cerec InEos, Trios, KaVo Everest and Sinergia Scan. The evaluation methodology of the experiment is based on CAD inspection. The results, obtained from accuracy and precision measurements with tolerance levels of 0.01, 0.25 and 0.05 mm, indicate that there is a difference in accuracy and precision between optical digitisation devices based on different working principles.
PB  - Maejo University
T2  - Maejo International Journal of Science & Technology
T1  - Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems
VL  - 11
IS  - 1
SP  - 45
EP  - 57
UR  - https://hdl.handle.net/21.15107/rcub_smile_2257
ER  - 
@article{
author = "Trifković, Branka and Budak, Igor and Vukelić, Đorđe and Puškar, Tatjana and Jevremović, Danimir and Todorović, Aleksandar and Todorović, Ana and Poštić, Srđan",
year = "2017",
abstract = "The implementation of intraoral and extraoral computer-aided-design and computer-aided-manufacturing (CAD/CAM) systems in prosthetic dentistry has simplified the procedure, shortened the period of design and manufacture and improved accuracy and aesthetic properties of dental restorations. Three-dimensional (3D) digitisation has become an adequate replacement for conventional dental impressions. The market offers a variety of diverse optical intraoral and extraoral CAD/CAM systems equipped with digitisation devices that are based on different working principles. The main goal of this research is to determine whether precision and accuracy differ among optical digitisation devices. The research includes five high-end devices: Cerec AC, Cerec InEos, Trios, KaVo Everest and Sinergia Scan. The evaluation methodology of the experiment is based on CAD inspection. The results, obtained from accuracy and precision measurements with tolerance levels of 0.01, 0.25 and 0.05 mm, indicate that there is a difference in accuracy and precision between optical digitisation devices based on different working principles.",
publisher = "Maejo University",
journal = "Maejo International Journal of Science & Technology",
title = "Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems",
volume = "11",
number = "1",
pages = "45-57",
url = "https://hdl.handle.net/21.15107/rcub_smile_2257"
}
Trifković, B., Budak, I., Vukelić, Đ., Puškar, T., Jevremović, D., Todorović, A., Todorović, A.,& Poštić, S.. (2017). Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems. in Maejo International Journal of Science & Technology
Maejo University., 11(1), 45-57.
https://hdl.handle.net/21.15107/rcub_smile_2257
Trifković B, Budak I, Vukelić Đ, Puškar T, Jevremović D, Todorović A, Todorović A, Poštić S. Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems. in Maejo International Journal of Science & Technology. 2017;11(1):45-57.
https://hdl.handle.net/21.15107/rcub_smile_2257 .
Trifković, Branka, Budak, Igor, Vukelić, Đorđe, Puškar, Tatjana, Jevremović, Danimir, Todorović, Aleksandar, Todorović, Ana, Poštić, Srđan, "Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems" in Maejo International Journal of Science & Technology, 11, no. 1 (2017):45-57,
https://hdl.handle.net/21.15107/rcub_smile_2257 .
2

Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide

Lapčević, Ana; Jevremović, Danimir; Trifković, Branka; Santoši, Željko; Vukelić, Đorđe

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2015)

TY  - JOUR
AU  - Lapčević, Ana
AU  - Jevremović, Danimir
AU  - Trifković, Branka
AU  - Santoši, Željko
AU  - Vukelić, Đorđe
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2067
AB  - Daily progress of dentistry, especially in the field of prosthodontics is introducing new materials and technologies. With the increasing need for aesthetically acceptable and non-metal materials, it came to development and improvement of ceramic materials and computer based systems (CA). The patient came in order to compensate the missing left lateral incisor. Since the adjacent teeth are brushed and the print was taken, casted model has been scanned using 3Shape D800 laboratory scanner. Dental restoration has been designed using 3Shape DentalSystem Premium software and the available tools. After completing the virtual design, the data are sent to the program responsible for CAM Zenotec® mini CAD/CAM device. As a result, the compensation with the full morphology was obtained without the need for finishing works.
AB  - Stomatologija, posebno stomatološka protetika svakodnevno napreduje uvođenjem novih materijala i tehnologija. Kako se javlja sve veća potreba za estetski prihvatljivim i bezmetalnim materijalima, došlo je do razvoja i unapređenja keramičkih materijala i računarima podržanih sistema (CA). Pacijent se javio radi nadoknade nedostajućeg levog bočnog sekutića. Pošto su susedni zubi zbrušeni i uzet otisak, izliven je model koji je skeniran pomoću 3Shape D 800 laboratorijskog skenera. Zubna nadoknada je dizajnirana pomo ću 3Shape DentalSystem Premium softvera korišćenjem raspoloživih alata. Nakon završenog dizajna virtuelni podaci su poslati u program odgovoran za CAM Zenotec® mini CAD/CAM uređaja. Kao rezultat, dobijena je nadoknada pune morfologije bez potrebe za dorađivanjem.
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide
T1  - Primena CAD/CAM tehnologije u projektovanju i izradi mostova pune anatomske forme na bazi cirkonijum-dioksida
VL  - 18
IS  - 1
SP  - 73
EP  - 75
UR  - https://hdl.handle.net/21.15107/rcub_smile_2067
ER  - 
@article{
author = "Lapčević, Ana and Jevremović, Danimir and Trifković, Branka and Santoši, Željko and Vukelić, Đorđe",
year = "2015",
abstract = "Daily progress of dentistry, especially in the field of prosthodontics is introducing new materials and technologies. With the increasing need for aesthetically acceptable and non-metal materials, it came to development and improvement of ceramic materials and computer based systems (CA). The patient came in order to compensate the missing left lateral incisor. Since the adjacent teeth are brushed and the print was taken, casted model has been scanned using 3Shape D800 laboratory scanner. Dental restoration has been designed using 3Shape DentalSystem Premium software and the available tools. After completing the virtual design, the data are sent to the program responsible for CAM Zenotec® mini CAD/CAM device. As a result, the compensation with the full morphology was obtained without the need for finishing works., Stomatologija, posebno stomatološka protetika svakodnevno napreduje uvođenjem novih materijala i tehnologija. Kako se javlja sve veća potreba za estetski prihvatljivim i bezmetalnim materijalima, došlo je do razvoja i unapređenja keramičkih materijala i računarima podržanih sistema (CA). Pacijent se javio radi nadoknade nedostajućeg levog bočnog sekutića. Pošto su susedni zubi zbrušeni i uzet otisak, izliven je model koji je skeniran pomoću 3Shape D 800 laboratorijskog skenera. Zubna nadoknada je dizajnirana pomo ću 3Shape DentalSystem Premium softvera korišćenjem raspoloživih alata. Nakon završenog dizajna virtuelni podaci su poslati u program odgovoran za CAM Zenotec® mini CAD/CAM uređaja. Kao rezultat, dobijena je nadoknada pune morfologije bez potrebe za dorađivanjem.",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide, Primena CAD/CAM tehnologije u projektovanju i izradi mostova pune anatomske forme na bazi cirkonijum-dioksida",
volume = "18",
number = "1",
pages = "73-75",
url = "https://hdl.handle.net/21.15107/rcub_smile_2067"
}
Lapčević, A., Jevremović, D., Trifković, B., Santoši, Ž.,& Vukelić, Đ.. (2015). Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 18(1), 73-75.
https://hdl.handle.net/21.15107/rcub_smile_2067
Lapčević A, Jevremović D, Trifković B, Santoši Ž, Vukelić Đ. Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide. in Journal of Production Engineering. 2015;18(1):73-75.
https://hdl.handle.net/21.15107/rcub_smile_2067 .
Lapčević, Ana, Jevremović, Danimir, Trifković, Branka, Santoši, Željko, Vukelić, Đorđe, "Application of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxide" in Journal of Production Engineering, 18, no. 1 (2015):73-75,
https://hdl.handle.net/21.15107/rcub_smile_2067 .

Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry

Puškar, Tatjana; Williams, Robert J.; Eggbeer, Dominic; Jevremović, Danimir; Lapčević, Ana; Trifković, Branka; Vukelić, Đorđe

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2013)

TY  - JOUR
AU  - Puškar, Tatjana
AU  - Williams, Robert J.
AU  - Eggbeer, Dominic
AU  - Jevremović, Danimir
AU  - Lapčević, Ana
AU  - Trifković, Branka
AU  - Vukelić, Đorđe
PY  - 2013
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1791
AB  - Corrosion resistance is one of the characteristics that dental alloy should possess as it should be placed in the oral cavity. Adverse tissue reactions of the gingiva and the periodontium close to dental cast alloys may be caused by the effects of released metal elements. Corrosion effect of dental Co-Cr-Mo alloy was investigated by ICP MS according to the EN ISO 10271 and EN ISO 22674. Co- Cr dental alloy Remanium GM 800+ (Dentaurum Ispringen, Germany was tested in artificial saliva for 7 days at 37ºC. The released metals were detected by Nexion 300X ICP MS (Perkin Elmer, USA). The results showed that the metal release was very low for Co, Cr and Mo, far below the permitted levels. ICP-MS can be considered as very reliable method for such a research.
AB  - Otpornost na koroziju je jedna od karakteristika koju poseduju stomatološke legure koje trebaju biti postavljene u usnoj duplji. Neželjene reakcije tkiva gingive i parodoncijuma sa stomatološkim legurama može biti uzrokovano efektima oslobođenih metalnih elemenata. Efekat korozije stomatološke Co- Cr -Mo legure ispitana je ICP MS prema EN ISO 10271 i EN ISO 22674 . Co- Cr stomatološke legure Remanium GM 800 + ( Dentaurum Ispringen , testirano u Nemačkoj u veštačkoj pljuvački tokom 7 dana na 37º C. Otkriveni su oslobođeni metali Nekion 300Ks ICP MS ( Perkin Elmer , SAD ). Rezultati su pokazali veoma slabo oslobađanje metala, Cr i Mo , daleko ispod dozvoljenih nivoa. ICP -MS može smatrati veoma pouzdan metod za ovakvo istraživanje .
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry
T1  - Utvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometrom
VL  - 16
IS  - 1
SP  - 77
EP  - 80
UR  - https://hdl.handle.net/21.15107/rcub_smile_1791
ER  - 
@article{
author = "Puškar, Tatjana and Williams, Robert J. and Eggbeer, Dominic and Jevremović, Danimir and Lapčević, Ana and Trifković, Branka and Vukelić, Đorđe",
year = "2013",
abstract = "Corrosion resistance is one of the characteristics that dental alloy should possess as it should be placed in the oral cavity. Adverse tissue reactions of the gingiva and the periodontium close to dental cast alloys may be caused by the effects of released metal elements. Corrosion effect of dental Co-Cr-Mo alloy was investigated by ICP MS according to the EN ISO 10271 and EN ISO 22674. Co- Cr dental alloy Remanium GM 800+ (Dentaurum Ispringen, Germany was tested in artificial saliva for 7 days at 37ºC. The released metals were detected by Nexion 300X ICP MS (Perkin Elmer, USA). The results showed that the metal release was very low for Co, Cr and Mo, far below the permitted levels. ICP-MS can be considered as very reliable method for such a research., Otpornost na koroziju je jedna od karakteristika koju poseduju stomatološke legure koje trebaju biti postavljene u usnoj duplji. Neželjene reakcije tkiva gingive i parodoncijuma sa stomatološkim legurama može biti uzrokovano efektima oslobođenih metalnih elemenata. Efekat korozije stomatološke Co- Cr -Mo legure ispitana je ICP MS prema EN ISO 10271 i EN ISO 22674 . Co- Cr stomatološke legure Remanium GM 800 + ( Dentaurum Ispringen , testirano u Nemačkoj u veštačkoj pljuvački tokom 7 dana na 37º C. Otkriveni su oslobođeni metali Nekion 300Ks ICP MS ( Perkin Elmer , SAD ). Rezultati su pokazali veoma slabo oslobađanje metala, Cr i Mo , daleko ispod dozvoljenih nivoa. ICP -MS može smatrati veoma pouzdan metod za ovakvo istraživanje .",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry, Utvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometrom",
volume = "16",
number = "1",
pages = "77-80",
url = "https://hdl.handle.net/21.15107/rcub_smile_1791"
}
Puškar, T., Williams, R. J., Eggbeer, D., Jevremović, D., Lapčević, A., Trifković, B.,& Vukelić, Đ.. (2013). Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 16(1), 77-80.
https://hdl.handle.net/21.15107/rcub_smile_1791
Puškar T, Williams RJ, Eggbeer D, Jevremović D, Lapčević A, Trifković B, Vukelić Đ. Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry. in Journal of Production Engineering. 2013;16(1):77-80.
https://hdl.handle.net/21.15107/rcub_smile_1791 .
Puškar, Tatjana, Williams, Robert J., Eggbeer, Dominic, Jevremović, Danimir, Lapčević, Ana, Trifković, Branka, Vukelić, Đorđe, "Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry" in Journal of Production Engineering, 16, no. 1 (2013):77-80,
https://hdl.handle.net/21.15107/rcub_smile_1791 .

An in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiography

Antonijević, Đorđe; Jevremović, Danimir; Jovanović, Svetlana; Obradović-Đuričić, Kosovka

(2012)

TY  - JOUR
AU  - Antonijević, Đorđe
AU  - Jevremović, Danimir
AU  - Jovanović, Svetlana
AU  - Obradović-Đuričić, Kosovka
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1694
AB  - Objective: According to the ISO, the radiopacity of luting cements should be equal to or greater than that of aluminum. The aim of this in vitro study was to determine the radiopacity of 13 commercially available dental luting cements and compare them with human enamel and dentin. Method and Materials: Five classes of luting cements were evaluated: zine phosphate (Cegal N and Harvard Zine Phosphate), zine polycarboxylate (Harvard Polycarboxylate and Hoffmann's Carboxylate), glass ionomers (Ketac Cem Fasymix, Ketac Cem Radiopaque, and Fuji I), resin-modified glass ionomer (Rely X Luting), and resin cements (Multilink Automix, Variolink II, Speed CEM, Rely X Unicem Automix, and three shades of Variolink Veneer). Tooth slices served as controls. Five specimens of each material measuring 8 mm in diameter and 1 mm thick were prepared and radiographed alongside tooth slices and an aluminum stepwedge using a Trophy RVG sensor. The radiopacity values were expressed in mm Al and analyzd by the ANOVA and Tukey tests (P  lt  .05). Results: All the cements examined except Variolink Veneer had significantly higher radiopacities than that of dentin. Rely X Unicem Automix, glass ionomer, and resin-modified glass-ionomer cements demonstrated radiopacities that were not significantly different with respect to enamel. Zinc phosphate, zinc polycarboxylate, and three of the resin cements presented radiopacity values that were significantly greater than that of enamel. Conclusion: Almost all the investigated materials presented an acceptable radiopacity. Radiopacity of dental cements seems to depend more on the presence of elements with high atomic numbers than on the type of the material. (Quintessence Int 2012; 43: 421-428)
T2  - Quintessence International
T1  - An in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiography
VL  - 43
IS  - 5
SP  - 421
EP  - 428
UR  - https://hdl.handle.net/21.15107/rcub_smile_1694
ER  - 
@article{
author = "Antonijević, Đorđe and Jevremović, Danimir and Jovanović, Svetlana and Obradović-Đuričić, Kosovka",
year = "2012",
abstract = "Objective: According to the ISO, the radiopacity of luting cements should be equal to or greater than that of aluminum. The aim of this in vitro study was to determine the radiopacity of 13 commercially available dental luting cements and compare them with human enamel and dentin. Method and Materials: Five classes of luting cements were evaluated: zine phosphate (Cegal N and Harvard Zine Phosphate), zine polycarboxylate (Harvard Polycarboxylate and Hoffmann's Carboxylate), glass ionomers (Ketac Cem Fasymix, Ketac Cem Radiopaque, and Fuji I), resin-modified glass ionomer (Rely X Luting), and resin cements (Multilink Automix, Variolink II, Speed CEM, Rely X Unicem Automix, and three shades of Variolink Veneer). Tooth slices served as controls. Five specimens of each material measuring 8 mm in diameter and 1 mm thick were prepared and radiographed alongside tooth slices and an aluminum stepwedge using a Trophy RVG sensor. The radiopacity values were expressed in mm Al and analyzd by the ANOVA and Tukey tests (P  lt  .05). Results: All the cements examined except Variolink Veneer had significantly higher radiopacities than that of dentin. Rely X Unicem Automix, glass ionomer, and resin-modified glass-ionomer cements demonstrated radiopacities that were not significantly different with respect to enamel. Zinc phosphate, zinc polycarboxylate, and three of the resin cements presented radiopacity values that were significantly greater than that of enamel. Conclusion: Almost all the investigated materials presented an acceptable radiopacity. Radiopacity of dental cements seems to depend more on the presence of elements with high atomic numbers than on the type of the material. (Quintessence Int 2012; 43: 421-428)",
journal = "Quintessence International",
title = "An in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiography",
volume = "43",
number = "5",
pages = "421-428",
url = "https://hdl.handle.net/21.15107/rcub_smile_1694"
}
Antonijević, Đ., Jevremović, D., Jovanović, S.,& Obradović-Đuričić, K.. (2012). An in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiography. in Quintessence International, 43(5), 421-428.
https://hdl.handle.net/21.15107/rcub_smile_1694
Antonijević Đ, Jevremović D, Jovanović S, Obradović-Đuričić K. An in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiography. in Quintessence International. 2012;43(5):421-428.
https://hdl.handle.net/21.15107/rcub_smile_1694 .
Antonijević, Đorđe, Jevremović, Danimir, Jovanović, Svetlana, Obradović-Đuričić, Kosovka, "An in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiography" in Quintessence International, 43, no. 5 (2012):421-428,
https://hdl.handle.net/21.15107/rcub_smile_1694 .
9
8

Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns

Trifković, Branka; Budak, Igor; Todorović, A.; Hodolić, Janko; Puškar, Tatjana; Jevremović, Danimir; Vukelić, Đorđe

(Versita, Warsaw, 2012)

TY  - JOUR
AU  - Trifković, Branka
AU  - Budak, Igor
AU  - Todorović, A.
AU  - Hodolić, Janko
AU  - Puškar, Tatjana
AU  - Jevremović, Danimir
AU  - Vukelić, Đorđe
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1737
AB  - The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
PB  - Versita, Warsaw
T2  - Measurement Science Review
T1  - Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns
VL  - 12
IS  - 3
SP  - 90
EP  - 97
DO  - 10.2478/v10048-012-0016-7
ER  - 
@article{
author = "Trifković, Branka and Budak, Igor and Todorović, A. and Hodolić, Janko and Puškar, Tatjana and Jevremović, Danimir and Vukelić, Đorđe",
year = "2012",
abstract = "The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.",
publisher = "Versita, Warsaw",
journal = "Measurement Science Review",
title = "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns",
volume = "12",
number = "3",
pages = "90-97",
doi = "10.2478/v10048-012-0016-7"
}
Trifković, B., Budak, I., Todorović, A., Hodolić, J., Puškar, T., Jevremović, D.,& Vukelić, Đ.. (2012). Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review
Versita, Warsaw., 12(3), 90-97.
https://doi.org/10.2478/v10048-012-0016-7
Trifković B, Budak I, Todorović A, Hodolić J, Puškar T, Jevremović D, Vukelić Đ. Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review. 2012;12(3):90-97.
doi:10.2478/v10048-012-0016-7 .
Trifković, Branka, Budak, Igor, Todorović, A., Hodolić, Janko, Puškar, Tatjana, Jevremović, Danimir, Vukelić, Đorđe, "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns" in Measurement Science Review, 12, no. 3 (2012):90-97,
https://doi.org/10.2478/v10048-012-0016-7 . .
21
11
25

Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization

Williams, Robert J.; Eggbeer, Dominic; Lapčević, Ana; Trifković, Branka; Puškar, Tatjana; Budak, Igor; Jevremović, Danimir

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2012)

TY  - JOUR
AU  - Williams, Robert J.
AU  - Eggbeer, Dominic
AU  - Lapčević, Ana
AU  - Trifković, Branka
AU  - Puškar, Tatjana
AU  - Budak, Igor
AU  - Jevremović, Danimir
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1701
AB  - CAD/CAM technology in dentistry offers high-end ceramic restorations, known for its quality, preciseness, swiftness and repeatability. However, some features are still human-dependent. A young female patient required smile enhancement, since suffering from colour change on three devitalized frontal teeth. After fiber post placement, teeth were prepared for metal-free restoration. Consequently, abutments were scanned using extraoral scanner (Sirona, InEos Blue; Beinsheim, Germany). CAD software (version 3.8) has been used to create three crown copings, with cut-back in the incisal region. After finalization of the virtual modeling, data file has been transferred to a milling unit (Sirona, MCXL, Beinsheim, Germany) that produced crown copings out of a ceramic block (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtestein). Crowns were tried for the fit and occlusion in the so-called blue stage, after which final strength and shape has been achieved by thermal treatment in the ceramic furnace. Individualization has been done manually, creating special effect in the cut-back region. Crowns were cemented adhesively. CAD/CAM offers modern and relevant way of producing ceramic restorations, however, special effects still require manual adjustments.
AB  - CAD/CAM tehnologije u stomatologiji nude visoko kvalitetne keramičke zamene, poznate po kvalitetu, preciznosti, brzini izrade i ponovljivosti. Međutim neke opcije još uvek zavise od ljudske intervencije. Mlada pacijentkinja je imala zahtev za poboljšanjem osmeha, pošto je patila od promene boje na tri prednja nezdrava zuba. Posle instalacije vlaknene podloge, zubi su bili spremni za bez-metalnu reparaciju. Otisci su bili skenirani ekstraoralnim skenerom (Sirona, InEos Blue, Beinsheim, Nemačka). CAD softver (verzija 3.8) je korišćen za generisanje tri navlake. Po završetku virtuelnog modeliranja podaci su prebačeni na glodalicu (Sirona, MCXL, Beinsheim, Nemačka) koja je izradila navlake od keramičkih blokova (IPS-a, max CAD, Ivoclar Vivadent, Schaan, Lihtenštajn). Navlake su posle isprobane zbog procene naleganja i začepljenja u tzv. plavoj etapi, posle čega je konačno očvršćavanje i oblikovanje postignuto termičkom obradom u peći za keramiku. Individualno prilagođavanje je izvršeno ručno, sa izradom posebnog efekta u zadnjem delu. Navlake su cementirane adhezijom. CAD/CAM nudi moderan i važan način u izradi keramičkih implanta ali posebni efekti još uvek zahtevaju intervenciju čoveka.
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization
T1  - Re-CAD/CAM pristup projektovanju i izradi zubnih keramičkih navlaka u kombinaciji sa ručnim individualnim prilagođavanjem
VL  - 15
IS  - 2
SP  - 91
EP  - 94
UR  - https://hdl.handle.net/21.15107/rcub_smile_1701
ER  - 
@article{
author = "Williams, Robert J. and Eggbeer, Dominic and Lapčević, Ana and Trifković, Branka and Puškar, Tatjana and Budak, Igor and Jevremović, Danimir",
year = "2012",
abstract = "CAD/CAM technology in dentistry offers high-end ceramic restorations, known for its quality, preciseness, swiftness and repeatability. However, some features are still human-dependent. A young female patient required smile enhancement, since suffering from colour change on three devitalized frontal teeth. After fiber post placement, teeth were prepared for metal-free restoration. Consequently, abutments were scanned using extraoral scanner (Sirona, InEos Blue; Beinsheim, Germany). CAD software (version 3.8) has been used to create three crown copings, with cut-back in the incisal region. After finalization of the virtual modeling, data file has been transferred to a milling unit (Sirona, MCXL, Beinsheim, Germany) that produced crown copings out of a ceramic block (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtestein). Crowns were tried for the fit and occlusion in the so-called blue stage, after which final strength and shape has been achieved by thermal treatment in the ceramic furnace. Individualization has been done manually, creating special effect in the cut-back region. Crowns were cemented adhesively. CAD/CAM offers modern and relevant way of producing ceramic restorations, however, special effects still require manual adjustments., CAD/CAM tehnologije u stomatologiji nude visoko kvalitetne keramičke zamene, poznate po kvalitetu, preciznosti, brzini izrade i ponovljivosti. Međutim neke opcije još uvek zavise od ljudske intervencije. Mlada pacijentkinja je imala zahtev za poboljšanjem osmeha, pošto je patila od promene boje na tri prednja nezdrava zuba. Posle instalacije vlaknene podloge, zubi su bili spremni za bez-metalnu reparaciju. Otisci su bili skenirani ekstraoralnim skenerom (Sirona, InEos Blue, Beinsheim, Nemačka). CAD softver (verzija 3.8) je korišćen za generisanje tri navlake. Po završetku virtuelnog modeliranja podaci su prebačeni na glodalicu (Sirona, MCXL, Beinsheim, Nemačka) koja je izradila navlake od keramičkih blokova (IPS-a, max CAD, Ivoclar Vivadent, Schaan, Lihtenštajn). Navlake su posle isprobane zbog procene naleganja i začepljenja u tzv. plavoj etapi, posle čega je konačno očvršćavanje i oblikovanje postignuto termičkom obradom u peći za keramiku. Individualno prilagođavanje je izvršeno ručno, sa izradom posebnog efekta u zadnjem delu. Navlake su cementirane adhezijom. CAD/CAM nudi moderan i važan način u izradi keramičkih implanta ali posebni efekti još uvek zahtevaju intervenciju čoveka.",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization, Re-CAD/CAM pristup projektovanju i izradi zubnih keramičkih navlaka u kombinaciji sa ručnim individualnim prilagođavanjem",
volume = "15",
number = "2",
pages = "91-94",
url = "https://hdl.handle.net/21.15107/rcub_smile_1701"
}
Williams, R. J., Eggbeer, D., Lapčević, A., Trifković, B., Puškar, T., Budak, I.,& Jevremović, D.. (2012). Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 15(2), 91-94.
https://hdl.handle.net/21.15107/rcub_smile_1701
Williams RJ, Eggbeer D, Lapčević A, Trifković B, Puškar T, Budak I, Jevremović D. Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization. in Journal of Production Engineering. 2012;15(2):91-94.
https://hdl.handle.net/21.15107/rcub_smile_1701 .
Williams, Robert J., Eggbeer, Dominic, Lapčević, Ana, Trifković, Branka, Puškar, Tatjana, Budak, Igor, Jevremović, Danimir, "Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization" in Journal of Production Engineering, 15, no. 2 (2012):91-94,
https://hdl.handle.net/21.15107/rcub_smile_1701 .

Accuracy of porcelain crowns made by using intraoral optical Cerec® 3DCAD/CAM system

Trifković, Branka; Todorović, Aleksandar; Jevremović, Danimir; Puškar, Tatjana; Marković, Dubravka

(Društvo lekara Vojvodine Srpskog lekarskog društva, Novi Sad, 2010)

TY  - JOUR
AU  - Trifković, Branka
AU  - Todorović, Aleksandar
AU  - Jevremović, Danimir
AU  - Puškar, Tatjana
AU  - Marković, Dubravka
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1549
AB  - Long term use of intraoral optical scanning methods in the production of fixed dental restorations is one of the recognizable characteristics of Cerec® 3D CAD/CAM system. The aim of this study was to determine the degree of precision of ceramic crowns made by the technique of intraoral optical Cerec®3D scanning system. Material and methods The crowns prepared for the experimental group were scanned by the intraoral optical Cerec® 3D scanning system. In the control group, the porcelain-fused-to-metal crowns were made according to the conventional methodology. The crown accuracy was examined by measuring the size of the marginal gap between the crown and the marginal adaptation zone using the scanning microscope. Discussion The results showed that there was a difference in the accuracy between crowns of the experimental (50.27±31.50 μ) and the control group (132.92±53.21 μ). Conclusion The crowns made using the methods with intraoral optical scanning Cerec 3D system showed a high and clinically acceptable degree of accuracy.
AB  - Dugogodišnja primena metoda intraoralnog optičkog skeniranja u postupku izrade fiksnih zubnih nadoknada jedna je od osobenosti po kojoj je prepoznatljiv sistem Cerec®3D CAD/CAM. Cilj rada je bio da se utvrdi stepen preciznosti keramičkih kruna izrađenih primenom tehnike intraoralnog optičkog skeniranja sistema Cerec®3D. Ispitivanje je sprovedeno u okviru eksperimentalne grupe kruna u čijoj je izradi primenjena tehnika intraoralnog optičkog skeniranja sistema Cerec®3D. Metalokeramičke krune izrađene konvencionalnom metodologijom bile su kontrolna grupa. Preciznost kruna ispitivana je merenjem veličine marginalnog zjapa između ruba krune i demarkacije preparacije pomoću skenirajućeg elektronskog mikroskopa. Rezultati istraživanja pokazuju da postoji razlika u preciznosti kruna eksperimentalne (50,27±31,50μ) i kontrolne grupe (132,92+53,21μ). Krune izrađene primenom metoda intraoralnog optičkog skeniranja sistema Cerec 3D pokazuju visok i klinički prihvatljiv stepen preciznosti.
PB  - Društvo lekara Vojvodine Srpskog lekarskog društva, Novi Sad
T2  - Stomatološki informator
T1  - Accuracy of porcelain crowns made by using intraoral optical Cerec® 3DCAD/CAM system
T1  - Preciznost keramičkih kruna izrađenih primenom metoda intraoralnog optičkog skeniranja sistema Cerec® 3D
VL  - 16
IS  - 26
SP  - 5
EP  - 9
UR  - https://hdl.handle.net/21.15107/rcub_smile_1549
ER  - 
@article{
author = "Trifković, Branka and Todorović, Aleksandar and Jevremović, Danimir and Puškar, Tatjana and Marković, Dubravka",
year = "2010",
abstract = "Long term use of intraoral optical scanning methods in the production of fixed dental restorations is one of the recognizable characteristics of Cerec® 3D CAD/CAM system. The aim of this study was to determine the degree of precision of ceramic crowns made by the technique of intraoral optical Cerec®3D scanning system. Material and methods The crowns prepared for the experimental group were scanned by the intraoral optical Cerec® 3D scanning system. In the control group, the porcelain-fused-to-metal crowns were made according to the conventional methodology. The crown accuracy was examined by measuring the size of the marginal gap between the crown and the marginal adaptation zone using the scanning microscope. Discussion The results showed that there was a difference in the accuracy between crowns of the experimental (50.27±31.50 μ) and the control group (132.92±53.21 μ). Conclusion The crowns made using the methods with intraoral optical scanning Cerec 3D system showed a high and clinically acceptable degree of accuracy., Dugogodišnja primena metoda intraoralnog optičkog skeniranja u postupku izrade fiksnih zubnih nadoknada jedna je od osobenosti po kojoj je prepoznatljiv sistem Cerec®3D CAD/CAM. Cilj rada je bio da se utvrdi stepen preciznosti keramičkih kruna izrađenih primenom tehnike intraoralnog optičkog skeniranja sistema Cerec®3D. Ispitivanje je sprovedeno u okviru eksperimentalne grupe kruna u čijoj je izradi primenjena tehnika intraoralnog optičkog skeniranja sistema Cerec®3D. Metalokeramičke krune izrađene konvencionalnom metodologijom bile su kontrolna grupa. Preciznost kruna ispitivana je merenjem veličine marginalnog zjapa između ruba krune i demarkacije preparacije pomoću skenirajućeg elektronskog mikroskopa. Rezultati istraživanja pokazuju da postoji razlika u preciznosti kruna eksperimentalne (50,27±31,50μ) i kontrolne grupe (132,92+53,21μ). Krune izrađene primenom metoda intraoralnog optičkog skeniranja sistema Cerec 3D pokazuju visok i klinički prihvatljiv stepen preciznosti.",
publisher = "Društvo lekara Vojvodine Srpskog lekarskog društva, Novi Sad",
journal = "Stomatološki informator",
title = "Accuracy of porcelain crowns made by using intraoral optical Cerec® 3DCAD/CAM system, Preciznost keramičkih kruna izrađenih primenom metoda intraoralnog optičkog skeniranja sistema Cerec® 3D",
volume = "16",
number = "26",
pages = "5-9",
url = "https://hdl.handle.net/21.15107/rcub_smile_1549"
}
Trifković, B., Todorović, A., Jevremović, D., Puškar, T.,& Marković, D.. (2010). Accuracy of porcelain crowns made by using intraoral optical Cerec® 3DCAD/CAM system. in Stomatološki informator
Društvo lekara Vojvodine Srpskog lekarskog društva, Novi Sad., 16(26), 5-9.
https://hdl.handle.net/21.15107/rcub_smile_1549
Trifković B, Todorović A, Jevremović D, Puškar T, Marković D. Accuracy of porcelain crowns made by using intraoral optical Cerec® 3DCAD/CAM system. in Stomatološki informator. 2010;16(26):5-9.
https://hdl.handle.net/21.15107/rcub_smile_1549 .
Trifković, Branka, Todorović, Aleksandar, Jevremović, Danimir, Puškar, Tatjana, Marković, Dubravka, "Accuracy of porcelain crowns made by using intraoral optical Cerec® 3DCAD/CAM system" in Stomatološki informator, 16, no. 26 (2010):5-9,
https://hdl.handle.net/21.15107/rcub_smile_1549 .

A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period

Jevremović, Danimir; Bošković, Mirjana V.; Puškar, Tatjana; Williams, Robert J.; Trifković, Branka; Eggbeer, Dominic

(Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš, 2010)

TY  - JOUR
AU  - Jevremović, Danimir
AU  - Bošković, Mirjana V.
AU  - Puškar, Tatjana
AU  - Williams, Robert J.
AU  - Trifković, Branka
AU  - Eggbeer, Dominic
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1546
AB  - Introduction. Inlay retained adhesive restorations present a conservative approach when a single tooth is missing in the posterior region. Material and methods. Twenty five restorations were included in the clinical study. Patient selection, preparation technique as well as denture fabrication followed current principles in this area. Patients were examined every 6 months over a 2 year examination period. Results were statistically analyzed. Results. The success rate for the first year comes to 91.1%, while cumulative success probability during the second year (24 months) was 86.6%. Furthermore, colour, texture and marginal staining were satisfactory during the observation period. Conclusion. Fibre-reinforced composite adhesive dentures are a tooth preserving, minimally invasive, aesthetic and reliable treatment option for single tooth replacement in the posterior area.
AB  - Uvod. Inlej retinirani adhezivni mostovi predstavljaju konzervativni modalitet tretmana nedostatka pojedinačnog zuba u bočnoj regiji. Materijal i metod. U kliničku studiju, uključeno je 25 adhezivnih nadoknada. Odabir pacijenata, principi preparacije, kao i tehnika izrade mostova urađeni su prema važećim standardima u ovoj oblasti. Pacijenti su praćeni na svakih 6 meseci tokom dvogodišnjeg perioda. Rezultati su statistički obrađeni. Rezultati. Uspešnost nadoknada u prvoj godini iznosi 91.1%, dok kumulativna uspešnost tokom druge godine (24 meseca) iznosi 86.6%. Takođe, ocena boje, teksture i marginalnog prebojavanja daje zadovoljavajuće rezulate tokom perioda praćenja. Zaključak. Kompozitne nadoknade ojačane vlaknima su minimalno invazivni, estetski i pouzdan način tretmana minimalne krezubosti bočnog segmenta denticije.
PB  - Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš
T2  - Acta stomatologica Naissi
T1  - A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period
T1  - Klinička evaluacija inlej-retiniranih adhezivnih mostova tokom dvogodišnjeg opservacionog perioda
VL  - 26
IS  - 62
SP  - 997
EP  - 1006
UR  - https://hdl.handle.net/21.15107/rcub_smile_1546
ER  - 
@article{
author = "Jevremović, Danimir and Bošković, Mirjana V. and Puškar, Tatjana and Williams, Robert J. and Trifković, Branka and Eggbeer, Dominic",
year = "2010",
abstract = "Introduction. Inlay retained adhesive restorations present a conservative approach when a single tooth is missing in the posterior region. Material and methods. Twenty five restorations were included in the clinical study. Patient selection, preparation technique as well as denture fabrication followed current principles in this area. Patients were examined every 6 months over a 2 year examination period. Results were statistically analyzed. Results. The success rate for the first year comes to 91.1%, while cumulative success probability during the second year (24 months) was 86.6%. Furthermore, colour, texture and marginal staining were satisfactory during the observation period. Conclusion. Fibre-reinforced composite adhesive dentures are a tooth preserving, minimally invasive, aesthetic and reliable treatment option for single tooth replacement in the posterior area., Uvod. Inlej retinirani adhezivni mostovi predstavljaju konzervativni modalitet tretmana nedostatka pojedinačnog zuba u bočnoj regiji. Materijal i metod. U kliničku studiju, uključeno je 25 adhezivnih nadoknada. Odabir pacijenata, principi preparacije, kao i tehnika izrade mostova urađeni su prema važećim standardima u ovoj oblasti. Pacijenti su praćeni na svakih 6 meseci tokom dvogodišnjeg perioda. Rezultati su statistički obrađeni. Rezultati. Uspešnost nadoknada u prvoj godini iznosi 91.1%, dok kumulativna uspešnost tokom druge godine (24 meseca) iznosi 86.6%. Takođe, ocena boje, teksture i marginalnog prebojavanja daje zadovoljavajuće rezulate tokom perioda praćenja. Zaključak. Kompozitne nadoknade ojačane vlaknima su minimalno invazivni, estetski i pouzdan način tretmana minimalne krezubosti bočnog segmenta denticije.",
publisher = "Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš",
journal = "Acta stomatologica Naissi",
title = "A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period, Klinička evaluacija inlej-retiniranih adhezivnih mostova tokom dvogodišnjeg opservacionog perioda",
volume = "26",
number = "62",
pages = "997-1006",
url = "https://hdl.handle.net/21.15107/rcub_smile_1546"
}
Jevremović, D., Bošković, M. V., Puškar, T., Williams, R. J., Trifković, B.,& Eggbeer, D.. (2010). A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period. in Acta stomatologica Naissi
Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš., 26(62), 997-1006.
https://hdl.handle.net/21.15107/rcub_smile_1546
Jevremović D, Bošković MV, Puškar T, Williams RJ, Trifković B, Eggbeer D. A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period. in Acta stomatologica Naissi. 2010;26(62):997-1006.
https://hdl.handle.net/21.15107/rcub_smile_1546 .
Jevremović, Danimir, Bošković, Mirjana V., Puškar, Tatjana, Williams, Robert J., Trifković, Branka, Eggbeer, Dominic, "A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period" in Acta stomatologica Naissi, 26, no. 62 (2010):997-1006,
https://hdl.handle.net/21.15107/rcub_smile_1546 .
2

Reconstruction of endodontically treated teeth after excessive loss of tooth structure: Two case reports

Stojičić, Sonja; Jevremović, Danimir; Živković, Slavoljub

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2009)

TY  - JOUR
AU  - Stojičić, Sonja
AU  - Jevremović, Danimir
AU  - Živković, Slavoljub
PY  - 2009
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1474
AB  - The prognosis of endodontically treated teeth depends not only on the success of the endodontic treatment, but also on the type of reconstruction. The use of fiber-reinforced resin (FRR) posts to restore endodontically treated teeth has gained popularity due to its mechanical and esthetic characteristics as well as properties of modern adhesive systems. The aim of this article was to show a clinical technique to reconstruct endodontically treated teeth with great loss of tooth structure using direct fiber-reinforced post systems and direct composite restorations. The first case was a patient with the fractured right second lower premolar. The tooth was endodontically treated and reconstructed thereafter. After the preparation of the root canal and cementation of a FRR post, particular attention was paid to the incremental and curing techniques adopted to reconstruct coronal part of the tooth. The second case was a patient with the fractured first right lower incisor. This tooth was treated in the same way. Direct composite reconstruction of endodontically treated teeth is an alternative to the prosthodontic therapy and can postpone prosthodontic therapy for a long time.
AB  - Prognoza endodontski lečenog zuba ne zavisi samo od uspešno izvedene endodontske terapije, već i od pravilne restauracije zuba i njegovog vraćanja u funkciju. Kompozitni kočići ojačani vlaknima poslednjih godina dobijaju na popularnosti u rekonstrukciji endodontski lečenih zuba zahvaljujući svojim estetskim i biomehaničkim osobinama, te mogućnosti ostvarivanja adhezivne veze za zub. Cilj ovog rada je da na primerima iz prakse ukaže na mogućnost konzervativne terapije endodontski lečenih zuba s velikim oštećenjima krunice primenom kompozitnih kanalnih kočića. Kod jedne pacijentkinje s frakturom donjeg desnog drugog premolara obavljeno je najpre endodontsko lečenje, a potom je urađena konzervativna restauracija. Posle preparacije prostora za kanalni kočić i njegovog cementiranja, krunični deo zuba je restauriran direktnim kompozitnim ispunom slojevitom tehnikom. Na isti način je lečen i donji desni centralni sekutić druge pacijentkinje. Restauracija devitalizovanih zuba s opsežnim lezijama konzervativnim lečenjem je dobra alternativa protetičkoj restauraciji, koja protetički tretman može odložiti za duži vremenski period.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Reconstruction of endodontically treated teeth after excessive loss of tooth structure: Two case reports
T1  - Mogućnosti rekonstrukcije endodontski lečenih zuba s velikim oštećenjima krunice - dva prikaza iz prakse
VL  - 56
IS  - 1
SP  - 40
EP  - 48
DO  - 10.2298/SGS0901040S
ER  - 
@article{
author = "Stojičić, Sonja and Jevremović, Danimir and Živković, Slavoljub",
year = "2009",
abstract = "The prognosis of endodontically treated teeth depends not only on the success of the endodontic treatment, but also on the type of reconstruction. The use of fiber-reinforced resin (FRR) posts to restore endodontically treated teeth has gained popularity due to its mechanical and esthetic characteristics as well as properties of modern adhesive systems. The aim of this article was to show a clinical technique to reconstruct endodontically treated teeth with great loss of tooth structure using direct fiber-reinforced post systems and direct composite restorations. The first case was a patient with the fractured right second lower premolar. The tooth was endodontically treated and reconstructed thereafter. After the preparation of the root canal and cementation of a FRR post, particular attention was paid to the incremental and curing techniques adopted to reconstruct coronal part of the tooth. The second case was a patient with the fractured first right lower incisor. This tooth was treated in the same way. Direct composite reconstruction of endodontically treated teeth is an alternative to the prosthodontic therapy and can postpone prosthodontic therapy for a long time., Prognoza endodontski lečenog zuba ne zavisi samo od uspešno izvedene endodontske terapije, već i od pravilne restauracije zuba i njegovog vraćanja u funkciju. Kompozitni kočići ojačani vlaknima poslednjih godina dobijaju na popularnosti u rekonstrukciji endodontski lečenih zuba zahvaljujući svojim estetskim i biomehaničkim osobinama, te mogućnosti ostvarivanja adhezivne veze za zub. Cilj ovog rada je da na primerima iz prakse ukaže na mogućnost konzervativne terapije endodontski lečenih zuba s velikim oštećenjima krunice primenom kompozitnih kanalnih kočića. Kod jedne pacijentkinje s frakturom donjeg desnog drugog premolara obavljeno je najpre endodontsko lečenje, a potom je urađena konzervativna restauracija. Posle preparacije prostora za kanalni kočić i njegovog cementiranja, krunični deo zuba je restauriran direktnim kompozitnim ispunom slojevitom tehnikom. Na isti način je lečen i donji desni centralni sekutić druge pacijentkinje. Restauracija devitalizovanih zuba s opsežnim lezijama konzervativnim lečenjem je dobra alternativa protetičkoj restauraciji, koja protetički tretman može odložiti za duži vremenski period.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Reconstruction of endodontically treated teeth after excessive loss of tooth structure: Two case reports, Mogućnosti rekonstrukcije endodontski lečenih zuba s velikim oštećenjima krunice - dva prikaza iz prakse",
volume = "56",
number = "1",
pages = "40-48",
doi = "10.2298/SGS0901040S"
}
Stojičić, S., Jevremović, D.,& Živković, S.. (2009). Reconstruction of endodontically treated teeth after excessive loss of tooth structure: Two case reports. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 56(1), 40-48.
https://doi.org/10.2298/SGS0901040S
Stojičić S, Jevremović D, Živković S. Reconstruction of endodontically treated teeth after excessive loss of tooth structure: Two case reports. in Stomatološki glasnik Srbije. 2009;56(1):40-48.
doi:10.2298/SGS0901040S .
Stojičić, Sonja, Jevremović, Danimir, Živković, Slavoljub, "Reconstruction of endodontically treated teeth after excessive loss of tooth structure: Two case reports" in Stomatološki glasnik Srbije, 56, no. 1 (2009):40-48,
https://doi.org/10.2298/SGS0901040S . .

Distribucija i koncentracija napona u adhezivnim mostovima

Jevremović, Danimir

(Univerzitet u Beogradu, Stomatološki fakultet, 2008)

TY  - THES
AU  - Jevremović, Danimir
PY  - 2008
UR  - https://plus.sr.cobiss.net/opac7/bib/1024035982
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/470
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Distribucija i koncentracija napona u adhezivnim mostovima
UR  - https://hdl.handle.net/21.15107/rcub_smile_470
ER  - 
@phdthesis{
author = "Jevremović, Danimir",
year = "2008",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Distribucija i koncentracija napona u adhezivnim mostovima",
url = "https://hdl.handle.net/21.15107/rcub_smile_470"
}
Jevremović, D.. (2008). Distribucija i koncentracija napona u adhezivnim mostovima. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_470
Jevremović D. Distribucija i koncentracija napona u adhezivnim mostovima. 2008;.
https://hdl.handle.net/21.15107/rcub_smile_470 .
Jevremović, Danimir, "Distribucija i koncentracija napona u adhezivnim mostovima" (2008),
https://hdl.handle.net/21.15107/rcub_smile_470 .

Inlay retainers as bridge abutments in the posterior segment: Case report

Jevremović, Danimir; Dodić, Slobodan

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2007)

TY  - JOUR
AU  - Jevremović, Danimir
AU  - Dodić, Slobodan
PY  - 2007
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1368
AB  - Inlay retained adhesive restorations are an interesting alternative to conventional methods when a single tooth is missing. The aim of this paper was to present possibilities for the application of inlay retained adhesive prosthodontic restorations based on composite systems. The clinical procedure is minimally invasive and simple to conduct. The introduction of fiber-reinforced composites as well as the improvement of adhesive cementing techniques makes these restorations a long-term solution with good esthetic and functional results. This case report offers an insight into the clinical procedure during the preparation of inlay retained adhesive restorations.
AB  - Inlej retinirane adhezivne nadoknade predstavljaju interesantnu alternativu konvencionalnim metodama, u slučaju nedostatka pojedinačnog zuba. Cilj ovog rada je bio da ukaže na mogućnosti primene inlay retiniranih adhezivnih protetskih nadoknada baziranih na kompozitnim sistemima. Klinička procedura je minimalno invazivna, i jednostavna za izvođenje. Uvođenje vlaknima-ojačanih kompozita, kao i poboljšanje adhezivnih tehnika cementiranja čine ove restauracije dugotrajnim rešenjem, sa dobrim estetskim i funkcionalnim rezultatima. Ovaj prikaz slučaja iz prakse daje uvid u kliničke postupke tokom izrade inlej retiniranih adhezivnih nadoknada.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Inlay retainers as bridge abutments in the posterior segment: Case report
T1  - Inlej retineri kao nosači tela mosta u bočnom segmentu - prikaz slučaja
VL  - 54
IS  - 4
SP  - 254
EP  - 264
DO  - 10.2298/SGS0704254J
ER  - 
@article{
author = "Jevremović, Danimir and Dodić, Slobodan",
year = "2007",
abstract = "Inlay retained adhesive restorations are an interesting alternative to conventional methods when a single tooth is missing. The aim of this paper was to present possibilities for the application of inlay retained adhesive prosthodontic restorations based on composite systems. The clinical procedure is minimally invasive and simple to conduct. The introduction of fiber-reinforced composites as well as the improvement of adhesive cementing techniques makes these restorations a long-term solution with good esthetic and functional results. This case report offers an insight into the clinical procedure during the preparation of inlay retained adhesive restorations., Inlej retinirane adhezivne nadoknade predstavljaju interesantnu alternativu konvencionalnim metodama, u slučaju nedostatka pojedinačnog zuba. Cilj ovog rada je bio da ukaže na mogućnosti primene inlay retiniranih adhezivnih protetskih nadoknada baziranih na kompozitnim sistemima. Klinička procedura je minimalno invazivna, i jednostavna za izvođenje. Uvođenje vlaknima-ojačanih kompozita, kao i poboljšanje adhezivnih tehnika cementiranja čine ove restauracije dugotrajnim rešenjem, sa dobrim estetskim i funkcionalnim rezultatima. Ovaj prikaz slučaja iz prakse daje uvid u kliničke postupke tokom izrade inlej retiniranih adhezivnih nadoknada.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Inlay retainers as bridge abutments in the posterior segment: Case report, Inlej retineri kao nosači tela mosta u bočnom segmentu - prikaz slučaja",
volume = "54",
number = "4",
pages = "254-264",
doi = "10.2298/SGS0704254J"
}
Jevremović, D.,& Dodić, S.. (2007). Inlay retainers as bridge abutments in the posterior segment: Case report. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 54(4), 254-264.
https://doi.org/10.2298/SGS0704254J
Jevremović D, Dodić S. Inlay retainers as bridge abutments in the posterior segment: Case report. in Stomatološki glasnik Srbije. 2007;54(4):254-264.
doi:10.2298/SGS0704254J .
Jevremović, Danimir, Dodić, Slobodan, "Inlay retainers as bridge abutments in the posterior segment: Case report" in Stomatološki glasnik Srbije, 54, no. 4 (2007):254-264,
https://doi.org/10.2298/SGS0704254J . .

Mehanička svojstva litijum-siliko-fluoroapatitnih keramičkih sistema

Jevremović, Danimir

(Univerzitet u Beogradu, Stomatološki fakultet, 2005)

TY  - THES
AU  - Jevremović, Danimir
PY  - 2005
UR  - https://plus.sr.cobiss.net/opac7/bib/1024043150
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/417
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Mehanička svojstva litijum-siliko-fluoroapatitnih keramičkih sistema
UR  - https://hdl.handle.net/21.15107/rcub_smile_417
ER  - 
@mastersthesis{
author = "Jevremović, Danimir",
year = "2005",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Mehanička svojstva litijum-siliko-fluoroapatitnih keramičkih sistema",
url = "https://hdl.handle.net/21.15107/rcub_smile_417"
}
Jevremović, D.. (2005). Mehanička svojstva litijum-siliko-fluoroapatitnih keramičkih sistema. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_417
Jevremović D. Mehanička svojstva litijum-siliko-fluoroapatitnih keramičkih sistema. 2005;.
https://hdl.handle.net/21.15107/rcub_smile_417 .
Jevremović, Danimir, "Mehanička svojstva litijum-siliko-fluoroapatitnih keramičkih sistema" (2005),
https://hdl.handle.net/21.15107/rcub_smile_417 .