In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry

Puškar, Tatjana; Trifković, Branka; Đurović-Koprivica, Daniela; Kojić, Vesna; Jevremović, Ana; Mirković, Siniša; Eggbeer, Dominic

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2019)

TY  - JOUR
AU  - Puškar, Tatjana
AU  - Trifković, Branka
AU  - Đurović-Koprivica, Daniela
AU  - Kojić, Vesna
AU  - Jevremović, Ana
AU  - Mirković, Siniša
AU  - Eggbeer, Dominic
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2446
AB  - Background/Aim. There is limited published evidence on the cytotoxicity of 3D printed polymer materials for dentistry applications, despite that they are now widely used in medicine. Stereolithography (SLA) is one of the foremost 3D processes used in 3D printing, yet there are only a small number of resin materials reported to be suitable for medical applications. The aim of this study was to investigate, in vitro, the cytotoxic effect of the 3D printed resin in order to establish the suitability for its usage in dentistry and related medical applications such as surgical dental guides, occlusal splits and orthodontic devices. Methods. To examine the cytotoxicity of the 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA), two cell cultures were used: mouse fibroblasts L929, and human lung fibroblasts MRC-5. The cell viability was determined by the Mosmann's colorimetric (MTT) test and the agar diffusion test (ADT). Results. Direct contact of the tested material with the ADT test showed nontoxic effects of tested material in any cell culture. The tested material showed no cytotoxic effect after 3 days of extraction of the eluate by the MTT, but mild cytotoxic effect after 5, 7 and 21 days on both cell lines. The cytotoxicity increased with increasing the time of the eluate extraction. Conclusion. The 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA) is considered appropriate for making surgical dental implant guides according to the cytotoxic behavior. According to the mild level of cytotoxicity after the longer extraction periods, there is a need for further evaluation of biocompatibility for its application for the occlusal splints and orthodontic devices.
AB  - Uvod/Cilj. Malo je objavljenih dokaza o citotoksičnosti 3D štampanih polimernih materijala za upotrebu u stomatologiji, bez obzira na njihovu sve širu primenu u medicini. Stereolitografija (SLA) jedan je od najvažnijih 3D procesa koji se primenjuje za 3D štampu, ali postoji samo Mali broj materijala na bazi smola za koje je dokazano da su pogodni za medicinsku primenu. Cilj ove studije je bio da se ispita, in vitro, citotoksični efekat 3D štampanog polimera kako bi se utvrdila mogućnost za njegovu upotrebu u stomatologiji i srodnim medicinskim oblastima, kao što su hirurške dentalne vođice, okluzalni splintovi i ortodontski aparati. Metode. Da bi se ispitala citotoksičnost 3D štampanog polimera na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA), korišc'ene su dve c'elijske kulture: fibroblasti miša L929 i humani fibroplasti pluc'a MRC-5. Vijabilnost c'elija utvrđena je Mosmannovim kolorimetrijskim testom (MTT) i testom difuzije agara (ADT). Rezultati. Direktan kontakt testiranog materijala ispitan pomoću ADT pokazao je da materijal nije imao citotoksičan efekat ni na jednu ćelijsku kulturu. Testitrani materijal je imao blag citotoksični efekat posle 5, 7 i 21 dana ekstrakcije eluata primenom MTT na obe ćelijske linije. Citotoksičnost je rasla sa produženjem vremena ekstrakcije eluata. Zaključak. 3D štampani polimer na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA) se može smatrati pogodnim za izradu hirurških dentalnih implantnih vođica sa tačke gledišta njegovog citotoksičnog uticaja. Zbog pokazanih blagih citotoksičnih efekata nakon dužih ekstrakcionih perioda eluata potrebna su dalja istraživanja u oblasti biokompatibilnosti materijala da bi se taj polimer mogao koristiti za izradu okluzalnih splintova i ortodontskih aparata.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry
T1  - In vitro procena citotoksičnosti 3D štampanog polimera na bazi epoksi smole namenjenog za upotrebu u stomatologiji
VL  - 76
IS  - 5
SP  - 502
EP  - 509
DO  - 10.2298/VSP170721127P
ER  - 
@article{
author = "Puškar, Tatjana and Trifković, Branka and Đurović-Koprivica, Daniela and Kojić, Vesna and Jevremović, Ana and Mirković, Siniša and Eggbeer, Dominic",
year = "2019",
abstract = "Background/Aim. There is limited published evidence on the cytotoxicity of 3D printed polymer materials for dentistry applications, despite that they are now widely used in medicine. Stereolithography (SLA) is one of the foremost 3D processes used in 3D printing, yet there are only a small number of resin materials reported to be suitable for medical applications. The aim of this study was to investigate, in vitro, the cytotoxic effect of the 3D printed resin in order to establish the suitability for its usage in dentistry and related medical applications such as surgical dental guides, occlusal splits and orthodontic devices. Methods. To examine the cytotoxicity of the 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA), two cell cultures were used: mouse fibroblasts L929, and human lung fibroblasts MRC-5. The cell viability was determined by the Mosmann's colorimetric (MTT) test and the agar diffusion test (ADT). Results. Direct contact of the tested material with the ADT test showed nontoxic effects of tested material in any cell culture. The tested material showed no cytotoxic effect after 3 days of extraction of the eluate by the MTT, but mild cytotoxic effect after 5, 7 and 21 days on both cell lines. The cytotoxicity increased with increasing the time of the eluate extraction. Conclusion. The 3D printed polymer-based epoxy resin, Accura® ClearVue™ (3D-Systems, USA) is considered appropriate for making surgical dental implant guides according to the cytotoxic behavior. According to the mild level of cytotoxicity after the longer extraction periods, there is a need for further evaluation of biocompatibility for its application for the occlusal splints and orthodontic devices., Uvod/Cilj. Malo je objavljenih dokaza o citotoksičnosti 3D štampanih polimernih materijala za upotrebu u stomatologiji, bez obzira na njihovu sve širu primenu u medicini. Stereolitografija (SLA) jedan je od najvažnijih 3D procesa koji se primenjuje za 3D štampu, ali postoji samo Mali broj materijala na bazi smola za koje je dokazano da su pogodni za medicinsku primenu. Cilj ove studije je bio da se ispita, in vitro, citotoksični efekat 3D štampanog polimera kako bi se utvrdila mogućnost za njegovu upotrebu u stomatologiji i srodnim medicinskim oblastima, kao što su hirurške dentalne vođice, okluzalni splintovi i ortodontski aparati. Metode. Da bi se ispitala citotoksičnost 3D štampanog polimera na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA), korišc'ene su dve c'elijske kulture: fibroblasti miša L929 i humani fibroplasti pluc'a MRC-5. Vijabilnost c'elija utvrđena je Mosmannovim kolorimetrijskim testom (MTT) i testom difuzije agara (ADT). Rezultati. Direktan kontakt testiranog materijala ispitan pomoću ADT pokazao je da materijal nije imao citotoksičan efekat ni na jednu ćelijsku kulturu. Testitrani materijal je imao blag citotoksični efekat posle 5, 7 i 21 dana ekstrakcije eluata primenom MTT na obe ćelijske linije. Citotoksičnost je rasla sa produženjem vremena ekstrakcije eluata. Zaključak. 3D štampani polimer na bazi epoksi smole, Accura® ClearVue ™ (3D-Sistems, USA) se može smatrati pogodnim za izradu hirurških dentalnih implantnih vođica sa tačke gledišta njegovog citotoksičnog uticaja. Zbog pokazanih blagih citotoksičnih efekata nakon dužih ekstrakcionih perioda eluata potrebna su dalja istraživanja u oblasti biokompatibilnosti materijala da bi se taj polimer mogao koristiti za izradu okluzalnih splintova i ortodontskih aparata.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry, In vitro procena citotoksičnosti 3D štampanog polimera na bazi epoksi smole namenjenog za upotrebu u stomatologiji",
volume = "76",
number = "5",
pages = "502-509",
doi = "10.2298/VSP170721127P"
}
Puškar, T., Trifković, B., Đurović-Koprivica, D., Kojić, V., Jevremović, A., Mirković, S.,& Eggbeer, D.. (2019). In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 76(5), 502-509.
https://doi.org/10.2298/VSP170721127P
Puškar T, Trifković B, Đurović-Koprivica D, Kojić V, Jevremović A, Mirković S, Eggbeer D. In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry. in Vojnosanitetski pregled. 2019;76(5):502-509.
doi:10.2298/VSP170721127P .
Puškar, Tatjana, Trifković, Branka, Đurović-Koprivica, Daniela, Kojić, Vesna, Jevremović, Ana, Mirković, Siniša, Eggbeer, Dominic, "In vitro cytotoxicity assessment of the 3D printed polymer based epoxy resin intended for use in dentistry" in Vojnosanitetski pregled, 76, no. 5 (2019):502-509,
https://doi.org/10.2298/VSP170721127P . .
13
4
12

Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry

Puškar, Tatjana; Williams, Robert J.; Eggbeer, Dominic; Jevremović, Danimir; Lapčević, Ana; Trifković, Branka; Vukelić, Đorđe

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2013)

TY  - JOUR
AU  - Puškar, Tatjana
AU  - Williams, Robert J.
AU  - Eggbeer, Dominic
AU  - Jevremović, Danimir
AU  - Lapčević, Ana
AU  - Trifković, Branka
AU  - Vukelić, Đorđe
PY  - 2013
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1791
AB  - Corrosion resistance is one of the characteristics that dental alloy should possess as it should be placed in the oral cavity. Adverse tissue reactions of the gingiva and the periodontium close to dental cast alloys may be caused by the effects of released metal elements. Corrosion effect of dental Co-Cr-Mo alloy was investigated by ICP MS according to the EN ISO 10271 and EN ISO 22674. Co- Cr dental alloy Remanium GM 800+ (Dentaurum Ispringen, Germany was tested in artificial saliva for 7 days at 37ºC. The released metals were detected by Nexion 300X ICP MS (Perkin Elmer, USA). The results showed that the metal release was very low for Co, Cr and Mo, far below the permitted levels. ICP-MS can be considered as very reliable method for such a research.
AB  - Otpornost na koroziju je jedna od karakteristika koju poseduju stomatološke legure koje trebaju biti postavljene u usnoj duplji. Neželjene reakcije tkiva gingive i parodoncijuma sa stomatološkim legurama može biti uzrokovano efektima oslobođenih metalnih elemenata. Efekat korozije stomatološke Co- Cr -Mo legure ispitana je ICP MS prema EN ISO 10271 i EN ISO 22674 . Co- Cr stomatološke legure Remanium GM 800 + ( Dentaurum Ispringen , testirano u Nemačkoj u veštačkoj pljuvački tokom 7 dana na 37º C. Otkriveni su oslobođeni metali Nekion 300Ks ICP MS ( Perkin Elmer , SAD ). Rezultati su pokazali veoma slabo oslobađanje metala, Cr i Mo , daleko ispod dozvoljenih nivoa. ICP -MS može smatrati veoma pouzdan metod za ovakvo istraživanje .
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry
T1  - Utvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometrom
VL  - 16
IS  - 1
SP  - 77
EP  - 80
UR  - https://hdl.handle.net/21.15107/rcub_smile_1791
ER  - 
@article{
author = "Puškar, Tatjana and Williams, Robert J. and Eggbeer, Dominic and Jevremović, Danimir and Lapčević, Ana and Trifković, Branka and Vukelić, Đorđe",
year = "2013",
abstract = "Corrosion resistance is one of the characteristics that dental alloy should possess as it should be placed in the oral cavity. Adverse tissue reactions of the gingiva and the periodontium close to dental cast alloys may be caused by the effects of released metal elements. Corrosion effect of dental Co-Cr-Mo alloy was investigated by ICP MS according to the EN ISO 10271 and EN ISO 22674. Co- Cr dental alloy Remanium GM 800+ (Dentaurum Ispringen, Germany was tested in artificial saliva for 7 days at 37ºC. The released metals were detected by Nexion 300X ICP MS (Perkin Elmer, USA). The results showed that the metal release was very low for Co, Cr and Mo, far below the permitted levels. ICP-MS can be considered as very reliable method for such a research., Otpornost na koroziju je jedna od karakteristika koju poseduju stomatološke legure koje trebaju biti postavljene u usnoj duplji. Neželjene reakcije tkiva gingive i parodoncijuma sa stomatološkim legurama može biti uzrokovano efektima oslobođenih metalnih elemenata. Efekat korozije stomatološke Co- Cr -Mo legure ispitana je ICP MS prema EN ISO 10271 i EN ISO 22674 . Co- Cr stomatološke legure Remanium GM 800 + ( Dentaurum Ispringen , testirano u Nemačkoj u veštačkoj pljuvački tokom 7 dana na 37º C. Otkriveni su oslobođeni metali Nekion 300Ks ICP MS ( Perkin Elmer , SAD ). Rezultati su pokazali veoma slabo oslobađanje metala, Cr i Mo , daleko ispod dozvoljenih nivoa. ICP -MS može smatrati veoma pouzdan metod za ovakvo istraživanje .",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry, Utvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometrom",
volume = "16",
number = "1",
pages = "77-80",
url = "https://hdl.handle.net/21.15107/rcub_smile_1791"
}
Puškar, T., Williams, R. J., Eggbeer, D., Jevremović, D., Lapčević, A., Trifković, B.,& Vukelić, Đ.. (2013). Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 16(1), 77-80.
https://hdl.handle.net/21.15107/rcub_smile_1791
Puškar T, Williams RJ, Eggbeer D, Jevremović D, Lapčević A, Trifković B, Vukelić Đ. Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry. in Journal of Production Engineering. 2013;16(1):77-80.
https://hdl.handle.net/21.15107/rcub_smile_1791 .
Puškar, Tatjana, Williams, Robert J., Eggbeer, Dominic, Jevremović, Danimir, Lapčević, Ana, Trifković, Branka, Vukelić, Đorđe, "Determination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometry" in Journal of Production Engineering, 16, no. 1 (2013):77-80,
https://hdl.handle.net/21.15107/rcub_smile_1791 .

Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization

Williams, Robert J.; Eggbeer, Dominic; Lapčević, Ana; Trifković, Branka; Puškar, Tatjana; Budak, Igor; Jevremović, Danimir

(Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad, 2012)

TY  - JOUR
AU  - Williams, Robert J.
AU  - Eggbeer, Dominic
AU  - Lapčević, Ana
AU  - Trifković, Branka
AU  - Puškar, Tatjana
AU  - Budak, Igor
AU  - Jevremović, Danimir
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1701
AB  - CAD/CAM technology in dentistry offers high-end ceramic restorations, known for its quality, preciseness, swiftness and repeatability. However, some features are still human-dependent. A young female patient required smile enhancement, since suffering from colour change on three devitalized frontal teeth. After fiber post placement, teeth were prepared for metal-free restoration. Consequently, abutments were scanned using extraoral scanner (Sirona, InEos Blue; Beinsheim, Germany). CAD software (version 3.8) has been used to create three crown copings, with cut-back in the incisal region. After finalization of the virtual modeling, data file has been transferred to a milling unit (Sirona, MCXL, Beinsheim, Germany) that produced crown copings out of a ceramic block (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtestein). Crowns were tried for the fit and occlusion in the so-called blue stage, after which final strength and shape has been achieved by thermal treatment in the ceramic furnace. Individualization has been done manually, creating special effect in the cut-back region. Crowns were cemented adhesively. CAD/CAM offers modern and relevant way of producing ceramic restorations, however, special effects still require manual adjustments.
AB  - CAD/CAM tehnologije u stomatologiji nude visoko kvalitetne keramičke zamene, poznate po kvalitetu, preciznosti, brzini izrade i ponovljivosti. Međutim neke opcije još uvek zavise od ljudske intervencije. Mlada pacijentkinja je imala zahtev za poboljšanjem osmeha, pošto je patila od promene boje na tri prednja nezdrava zuba. Posle instalacije vlaknene podloge, zubi su bili spremni za bez-metalnu reparaciju. Otisci su bili skenirani ekstraoralnim skenerom (Sirona, InEos Blue, Beinsheim, Nemačka). CAD softver (verzija 3.8) je korišćen za generisanje tri navlake. Po završetku virtuelnog modeliranja podaci su prebačeni na glodalicu (Sirona, MCXL, Beinsheim, Nemačka) koja je izradila navlake od keramičkih blokova (IPS-a, max CAD, Ivoclar Vivadent, Schaan, Lihtenštajn). Navlake su posle isprobane zbog procene naleganja i začepljenja u tzv. plavoj etapi, posle čega je konačno očvršćavanje i oblikovanje postignuto termičkom obradom u peći za keramiku. Individualno prilagođavanje je izvršeno ručno, sa izradom posebnog efekta u zadnjem delu. Navlake su cementirane adhezijom. CAD/CAM nudi moderan i važan način u izradi keramičkih implanta ali posebni efekti još uvek zahtevaju intervenciju čoveka.
PB  - Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
T2  - Journal of Production Engineering
T1  - Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization
T1  - Re-CAD/CAM pristup projektovanju i izradi zubnih keramičkih navlaka u kombinaciji sa ručnim individualnim prilagođavanjem
VL  - 15
IS  - 2
SP  - 91
EP  - 94
UR  - https://hdl.handle.net/21.15107/rcub_smile_1701
ER  - 
@article{
author = "Williams, Robert J. and Eggbeer, Dominic and Lapčević, Ana and Trifković, Branka and Puškar, Tatjana and Budak, Igor and Jevremović, Danimir",
year = "2012",
abstract = "CAD/CAM technology in dentistry offers high-end ceramic restorations, known for its quality, preciseness, swiftness and repeatability. However, some features are still human-dependent. A young female patient required smile enhancement, since suffering from colour change on three devitalized frontal teeth. After fiber post placement, teeth were prepared for metal-free restoration. Consequently, abutments were scanned using extraoral scanner (Sirona, InEos Blue; Beinsheim, Germany). CAD software (version 3.8) has been used to create three crown copings, with cut-back in the incisal region. After finalization of the virtual modeling, data file has been transferred to a milling unit (Sirona, MCXL, Beinsheim, Germany) that produced crown copings out of a ceramic block (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtestein). Crowns were tried for the fit and occlusion in the so-called blue stage, after which final strength and shape has been achieved by thermal treatment in the ceramic furnace. Individualization has been done manually, creating special effect in the cut-back region. Crowns were cemented adhesively. CAD/CAM offers modern and relevant way of producing ceramic restorations, however, special effects still require manual adjustments., CAD/CAM tehnologije u stomatologiji nude visoko kvalitetne keramičke zamene, poznate po kvalitetu, preciznosti, brzini izrade i ponovljivosti. Međutim neke opcije još uvek zavise od ljudske intervencije. Mlada pacijentkinja je imala zahtev za poboljšanjem osmeha, pošto je patila od promene boje na tri prednja nezdrava zuba. Posle instalacije vlaknene podloge, zubi su bili spremni za bez-metalnu reparaciju. Otisci su bili skenirani ekstraoralnim skenerom (Sirona, InEos Blue, Beinsheim, Nemačka). CAD softver (verzija 3.8) je korišćen za generisanje tri navlake. Po završetku virtuelnog modeliranja podaci su prebačeni na glodalicu (Sirona, MCXL, Beinsheim, Nemačka) koja je izradila navlake od keramičkih blokova (IPS-a, max CAD, Ivoclar Vivadent, Schaan, Lihtenštajn). Navlake su posle isprobane zbog procene naleganja i začepljenja u tzv. plavoj etapi, posle čega je konačno očvršćavanje i oblikovanje postignuto termičkom obradom u peći za keramiku. Individualno prilagođavanje je izvršeno ručno, sa izradom posebnog efekta u zadnjem delu. Navlake su cementirane adhezijom. CAD/CAM nudi moderan i važan način u izradi keramičkih implanta ali posebni efekti još uvek zahtevaju intervenciju čoveka.",
publisher = "Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad",
journal = "Journal of Production Engineering",
title = "Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization, Re-CAD/CAM pristup projektovanju i izradi zubnih keramičkih navlaka u kombinaciji sa ručnim individualnim prilagođavanjem",
volume = "15",
number = "2",
pages = "91-94",
url = "https://hdl.handle.net/21.15107/rcub_smile_1701"
}
Williams, R. J., Eggbeer, D., Lapčević, A., Trifković, B., Puškar, T., Budak, I.,& Jevremović, D.. (2012). Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization. in Journal of Production Engineering
Univerzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad., 15(2), 91-94.
https://hdl.handle.net/21.15107/rcub_smile_1701
Williams RJ, Eggbeer D, Lapčević A, Trifković B, Puškar T, Budak I, Jevremović D. Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization. in Journal of Production Engineering. 2012;15(2):91-94.
https://hdl.handle.net/21.15107/rcub_smile_1701 .
Williams, Robert J., Eggbeer, Dominic, Lapčević, Ana, Trifković, Branka, Puškar, Tatjana, Budak, Igor, Jevremović, Danimir, "Re-CAD/CAM approach in design and manufacturing of dental ceramic crowns in combination with manual individualization" in Journal of Production Engineering, 15, no. 2 (2012):91-94,
https://hdl.handle.net/21.15107/rcub_smile_1701 .

A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period

Jevremović, Danimir; Bošković, Mirjana V.; Puškar, Tatjana; Williams, Robert J.; Trifković, Branka; Eggbeer, Dominic

(Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš, 2010)

TY  - JOUR
AU  - Jevremović, Danimir
AU  - Bošković, Mirjana V.
AU  - Puškar, Tatjana
AU  - Williams, Robert J.
AU  - Trifković, Branka
AU  - Eggbeer, Dominic
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1546
AB  - Introduction. Inlay retained adhesive restorations present a conservative approach when a single tooth is missing in the posterior region. Material and methods. Twenty five restorations were included in the clinical study. Patient selection, preparation technique as well as denture fabrication followed current principles in this area. Patients were examined every 6 months over a 2 year examination period. Results were statistically analyzed. Results. The success rate for the first year comes to 91.1%, while cumulative success probability during the second year (24 months) was 86.6%. Furthermore, colour, texture and marginal staining were satisfactory during the observation period. Conclusion. Fibre-reinforced composite adhesive dentures are a tooth preserving, minimally invasive, aesthetic and reliable treatment option for single tooth replacement in the posterior area.
AB  - Uvod. Inlej retinirani adhezivni mostovi predstavljaju konzervativni modalitet tretmana nedostatka pojedinačnog zuba u bočnoj regiji. Materijal i metod. U kliničku studiju, uključeno je 25 adhezivnih nadoknada. Odabir pacijenata, principi preparacije, kao i tehnika izrade mostova urađeni su prema važećim standardima u ovoj oblasti. Pacijenti su praćeni na svakih 6 meseci tokom dvogodišnjeg perioda. Rezultati su statistički obrađeni. Rezultati. Uspešnost nadoknada u prvoj godini iznosi 91.1%, dok kumulativna uspešnost tokom druge godine (24 meseca) iznosi 86.6%. Takođe, ocena boje, teksture i marginalnog prebojavanja daje zadovoljavajuće rezulate tokom perioda praćenja. Zaključak. Kompozitne nadoknade ojačane vlaknima su minimalno invazivni, estetski i pouzdan način tretmana minimalne krezubosti bočnog segmenta denticije.
PB  - Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš
T2  - Acta stomatologica Naissi
T1  - A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period
T1  - Klinička evaluacija inlej-retiniranih adhezivnih mostova tokom dvogodišnjeg opservacionog perioda
VL  - 26
IS  - 62
SP  - 997
EP  - 1006
UR  - https://hdl.handle.net/21.15107/rcub_smile_1546
ER  - 
@article{
author = "Jevremović, Danimir and Bošković, Mirjana V. and Puškar, Tatjana and Williams, Robert J. and Trifković, Branka and Eggbeer, Dominic",
year = "2010",
abstract = "Introduction. Inlay retained adhesive restorations present a conservative approach when a single tooth is missing in the posterior region. Material and methods. Twenty five restorations were included in the clinical study. Patient selection, preparation technique as well as denture fabrication followed current principles in this area. Patients were examined every 6 months over a 2 year examination period. Results were statistically analyzed. Results. The success rate for the first year comes to 91.1%, while cumulative success probability during the second year (24 months) was 86.6%. Furthermore, colour, texture and marginal staining were satisfactory during the observation period. Conclusion. Fibre-reinforced composite adhesive dentures are a tooth preserving, minimally invasive, aesthetic and reliable treatment option for single tooth replacement in the posterior area., Uvod. Inlej retinirani adhezivni mostovi predstavljaju konzervativni modalitet tretmana nedostatka pojedinačnog zuba u bočnoj regiji. Materijal i metod. U kliničku studiju, uključeno je 25 adhezivnih nadoknada. Odabir pacijenata, principi preparacije, kao i tehnika izrade mostova urađeni su prema važećim standardima u ovoj oblasti. Pacijenti su praćeni na svakih 6 meseci tokom dvogodišnjeg perioda. Rezultati su statistički obrađeni. Rezultati. Uspešnost nadoknada u prvoj godini iznosi 91.1%, dok kumulativna uspešnost tokom druge godine (24 meseca) iznosi 86.6%. Takođe, ocena boje, teksture i marginalnog prebojavanja daje zadovoljavajuće rezulate tokom perioda praćenja. Zaključak. Kompozitne nadoknade ojačane vlaknima su minimalno invazivni, estetski i pouzdan način tretmana minimalne krezubosti bočnog segmenta denticije.",
publisher = "Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš",
journal = "Acta stomatologica Naissi",
title = "A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period, Klinička evaluacija inlej-retiniranih adhezivnih mostova tokom dvogodišnjeg opservacionog perioda",
volume = "26",
number = "62",
pages = "997-1006",
url = "https://hdl.handle.net/21.15107/rcub_smile_1546"
}
Jevremović, D., Bošković, M. V., Puškar, T., Williams, R. J., Trifković, B.,& Eggbeer, D.. (2010). A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period. in Acta stomatologica Naissi
Univerzitet u Nišu - Medicinski fakultet, Niš i Klinika za stomatologiju, Niš., 26(62), 997-1006.
https://hdl.handle.net/21.15107/rcub_smile_1546
Jevremović D, Bošković MV, Puškar T, Williams RJ, Trifković B, Eggbeer D. A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period. in Acta stomatologica Naissi. 2010;26(62):997-1006.
https://hdl.handle.net/21.15107/rcub_smile_1546 .
Jevremović, Danimir, Bošković, Mirjana V., Puškar, Tatjana, Williams, Robert J., Trifković, Branka, Eggbeer, Dominic, "A clinical evaluation of inlay-retained fixed partial dentures after a two-year observation period" in Acta stomatologica Naissi, 26, no. 62 (2010):997-1006,
https://hdl.handle.net/21.15107/rcub_smile_1546 .
2