Hodolić, Janko

Link to this page

Authority KeyName Variants
c22ffd86-1970-41ef-ae62-2021e888714a
  • Hodolić, Janko (2)
Projects

Author's Bibliography

Comparative analysis of 3d digitization systems in the field of dental prosthetics

Budak, Igor; Trifković, Branka; Puškar, Tatjana; Vukelić, Đorđe; Vucaj-Cirilović, Viktorija; Hodolić, Janko; Todorović, Aleksandar

(Faculty of Mechanical Engineering in Slavonski Brod, Faculty of Electrical Engineering in Osijek, Faculty of Civil Engineering in Osijek, 2013)

TY  - JOUR
AU  - Budak, Igor
AU  - Trifković, Branka
AU  - Puškar, Tatjana
AU  - Vukelić, Đorđe
AU  - Vucaj-Cirilović, Viktorija
AU  - Hodolić, Janko
AU  - Todorović, Aleksandar
PY  - 2013
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1845
AB  - Amongst the modern engineering technologies which have found broad application in the field of dentistry, one of the most widely used is the 3D digitization. This paper deals with the application of 3D digitization systems in the field of dental prosthetics, and attempt to contribute in this field through comparative analysis of this kind of systems. Special attention is focused on extra oral 3D digitization systems and among them on non specialized dental 3D digitization systems. Beside the general overview and analysis of nine different systems, this paper presents experimental results of comparative accuracy analysis of two high-end 3D digitization systems - Atos II Triple Scan and Zeiss Metrotom 1500. Investigation was based on CAD inspection technique and included 3D and 2D cross sectional analysis. Results related to 3D analysis show that the majority of deviations are in positive direction, concentrated around 0,025 mm. Results of 2D analysis implicate the conclusion that the accuracy of the analysed systems is dependent on surface shape as well as on the model position during the process of 3D digitization.
PB  - Faculty of Mechanical Engineering in Slavonski Brod, Faculty of Electrical Engineering in Osijek, Faculty of Civil Engineering in Osijek
T2  - Tehnički vjesnik
T1  - Comparative analysis of 3d digitization systems in the field of dental prosthetics
VL  - 20
IS  - 2
SP  - 291
EP  - 296
UR  - https://hdl.handle.net/21.15107/rcub_smile_1845
ER  - 
@article{
author = "Budak, Igor and Trifković, Branka and Puškar, Tatjana and Vukelić, Đorđe and Vucaj-Cirilović, Viktorija and Hodolić, Janko and Todorović, Aleksandar",
year = "2013",
abstract = "Amongst the modern engineering technologies which have found broad application in the field of dentistry, one of the most widely used is the 3D digitization. This paper deals with the application of 3D digitization systems in the field of dental prosthetics, and attempt to contribute in this field through comparative analysis of this kind of systems. Special attention is focused on extra oral 3D digitization systems and among them on non specialized dental 3D digitization systems. Beside the general overview and analysis of nine different systems, this paper presents experimental results of comparative accuracy analysis of two high-end 3D digitization systems - Atos II Triple Scan and Zeiss Metrotom 1500. Investigation was based on CAD inspection technique and included 3D and 2D cross sectional analysis. Results related to 3D analysis show that the majority of deviations are in positive direction, concentrated around 0,025 mm. Results of 2D analysis implicate the conclusion that the accuracy of the analysed systems is dependent on surface shape as well as on the model position during the process of 3D digitization.",
publisher = "Faculty of Mechanical Engineering in Slavonski Brod, Faculty of Electrical Engineering in Osijek, Faculty of Civil Engineering in Osijek",
journal = "Tehnički vjesnik",
title = "Comparative analysis of 3d digitization systems in the field of dental prosthetics",
volume = "20",
number = "2",
pages = "291-296",
url = "https://hdl.handle.net/21.15107/rcub_smile_1845"
}
Budak, I., Trifković, B., Puškar, T., Vukelić, Đ., Vucaj-Cirilović, V., Hodolić, J.,& Todorović, A.. (2013). Comparative analysis of 3d digitization systems in the field of dental prosthetics. in Tehnički vjesnik
Faculty of Mechanical Engineering in Slavonski Brod, Faculty of Electrical Engineering in Osijek, Faculty of Civil Engineering in Osijek., 20(2), 291-296.
https://hdl.handle.net/21.15107/rcub_smile_1845
Budak I, Trifković B, Puškar T, Vukelić Đ, Vucaj-Cirilović V, Hodolić J, Todorović A. Comparative analysis of 3d digitization systems in the field of dental prosthetics. in Tehnički vjesnik. 2013;20(2):291-296.
https://hdl.handle.net/21.15107/rcub_smile_1845 .
Budak, Igor, Trifković, Branka, Puškar, Tatjana, Vukelić, Đorđe, Vucaj-Cirilović, Viktorija, Hodolić, Janko, Todorović, Aleksandar, "Comparative analysis of 3d digitization systems in the field of dental prosthetics" in Tehnički vjesnik, 20, no. 2 (2013):291-296,
https://hdl.handle.net/21.15107/rcub_smile_1845 .
11
12

Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns

Trifković, Branka; Budak, Igor; Todorović, A.; Hodolić, Janko; Puškar, Tatjana; Jevremović, Danimir; Vukelić, Đorđe

(Versita, Warsaw, 2012)

TY  - JOUR
AU  - Trifković, Branka
AU  - Budak, Igor
AU  - Todorović, A.
AU  - Hodolić, Janko
AU  - Puškar, Tatjana
AU  - Jevremović, Danimir
AU  - Vukelić, Đorđe
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1737
AB  - The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
PB  - Versita, Warsaw
T2  - Measurement Science Review
T1  - Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns
VL  - 12
IS  - 3
SP  - 90
EP  - 97
DO  - 10.2478/v10048-012-0016-7
ER  - 
@article{
author = "Trifković, Branka and Budak, Igor and Todorović, A. and Hodolić, Janko and Puškar, Tatjana and Jevremović, Danimir and Vukelić, Đorđe",
year = "2012",
abstract = "The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.",
publisher = "Versita, Warsaw",
journal = "Measurement Science Review",
title = "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns",
volume = "12",
number = "3",
pages = "90-97",
doi = "10.2478/v10048-012-0016-7"
}
Trifković, B., Budak, I., Todorović, A., Hodolić, J., Puškar, T., Jevremović, D.,& Vukelić, Đ.. (2012). Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review
Versita, Warsaw., 12(3), 90-97.
https://doi.org/10.2478/v10048-012-0016-7
Trifković B, Budak I, Todorović A, Hodolić J, Puškar T, Jevremović D, Vukelić Đ. Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review. 2012;12(3):90-97.
doi:10.2478/v10048-012-0016-7 .
Trifković, Branka, Budak, Igor, Todorović, A., Hodolić, Janko, Puškar, Tatjana, Jevremović, Danimir, Vukelić, Đorđe, "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns" in Measurement Science Review, 12, no. 3 (2012):90-97,
https://doi.org/10.2478/v10048-012-0016-7 . .
21
11
25