Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study

Stošić, Miljan; Geler, Katarina; Petrović, Violeta; Jovanović-Medojević, Milica

(Univerzitet u Beogradu - Medicinski fakultet, Beograd, 2023)

TY  - JOUR
AU  - Stošić, Miljan
AU  - Geler, Katarina
AU  - Petrović, Violeta
AU  - Jovanović-Medojević, Milica
PY  - 2023
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/3279
AB  - Introduction: Preparation of glide path is an important precondition for the safe use of rotary NiTi instruments during endodontic treatment. Aim: The aim of this study was to examine the duration of glide path preparation as well as all the changes in canal morphology and canal diameter after the use of hand K-files and NiTi rotary PathFiles. Material and methods: This research was performed on a total of twenty Endo Training Blocks (Dentsply, Maillefer, Switzerland). The glide path was prepared using hand stainless steel K-files ISO #10-15-20 (Dentsply, Sirona, USA) (n = 10) and NiTi rotary PathFiles ISO #13, #16 and #19 (Dentsply, Sirona, Switzerland) (n = 10). The time required to establish the glide path was measured with an iPhone stopwatch (Apple Inc. Cupertino, California). The images of the apical segment of canals before and after glide path preparation were taken under the stereomicroscope (Boeco BSZ-405, Germany), and then images were analyzed and processed with Scopeimage 9.0 (Teleskop, Austria). Statistical analysis was performed with the Mann-Whitney test at the level of significance 5% (a = 0.05). Results: A statistically significant difference was observed in terms of the time required for glide path preparation. The mean total time for glide path preparation was significantly longer with K-files (382 ± 62 s) than with PathFile (200 ± 11 s) (p < 0.05). A statistically significant difference in terms of changing the morphology of the apical part of the canal (p > 0.05) was not observed. The difference in the diameter of the root canal was at the limit of statistical significance (p ≈ 0.05). Conclusion: Instrumentation with NiTi rotary PathFiles reduces the time required for glide path preparation. Preparing endodontic space for rotary instrumentation with hand K-Files and rotary PathFiles leads to similar changes in the morphology of the apical segment. A slightly larger diameter of the root canal was measured after preparation with the hand K-files.
AB  - Uvod: Uspostavljanje instrumentacione putanje je važan preduslov za bezbednu primenu mašinskih NiTi instrumentata tokom oblikovanja kanalskih sistema. Cilj: Cilj ovog rada je bio da se uporedi vreme potrebno za formiranje instrumentacione putanje, kao i promene u morfologiji apikalnog segmenta i prečniku apikalnog otvora kanala posle primene ručnih K-turpija i mašinskih PathFile instrumenata. Materijal i metode: Istraživanje je realizovano na 20 "endo trening" modela (Dentsply Maillefer, Switzerland). Instrumentaciona putanja je uspostavljena primenom ručnih K-turpija od nerđajućeg čelika (#10-15-20) (Dentsply, Sirona, Switzerland) (n = 10), odnosno mašinskih PathFile NiTi instrumenata (Dentsply, Sirona, Switzerland) (n = 10). Vreme potrebno za uspostavljanje instrumentacione putanje mereno je iPhone stopwatch (Apple Inc. Cupertino, California). Slike apikalnog segmenta kanala, pre i posle formiranja instrumentacione putanje, snimane su stereomikroskopom (Boeco BSZ-405, Germany), a zatim obrađene i analizirane u softverskom programu Scopeimage 9.0. Dobijeni podaci statistički su obrađeni Man-Vitnijevim (Mann-Whitney) testom (a = 0,05). Rezultati: Uočena je statistički značajna razlika u pogledu vremena potrebnog za uspostavljanje instrumentacione putanje između ručnih K-turpija (6 min. 22 s) i mašinskih PathFile instrumenata (3 min. 20 s) (p < 0,05). U pogledu morfologije apikalnog segmenta nisu uočene značajne razlike (p > 0,05). Razlike u prečniku apikalnog otvora bile su na granici statističke značajnosti (p ≈ 0,05). Zaključak: Primena mašinskih PathFile instrumenata rezultirala je bržim formiranjem instrumentacione putanje u poređenju sa ručnim K-turpijama. Obe ispitivane grupe instrumenata dovele su do sličnih promena u morfologiji apikalnog segmenta kanala. Nešto veći prečnik apikalnog otvora kanala izmeren je posle primene ručnih K-turpija.
PB  - Univerzitet u Beogradu - Medicinski fakultet, Beograd
T2  - Medicinski podmladak
T1  - Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study
T1  - Formiranje instrumentacione putanje ručnim i mašinskim instrumentima u povijenim kanalima - in vitro studija
VL  - 74
IS  - 2
SP  - 62
EP  - 67
DO  - 10.5937/mp74-39415
ER  - 
@article{
author = "Stošić, Miljan and Geler, Katarina and Petrović, Violeta and Jovanović-Medojević, Milica",
year = "2023",
abstract = "Introduction: Preparation of glide path is an important precondition for the safe use of rotary NiTi instruments during endodontic treatment. Aim: The aim of this study was to examine the duration of glide path preparation as well as all the changes in canal morphology and canal diameter after the use of hand K-files and NiTi rotary PathFiles. Material and methods: This research was performed on a total of twenty Endo Training Blocks (Dentsply, Maillefer, Switzerland). The glide path was prepared using hand stainless steel K-files ISO #10-15-20 (Dentsply, Sirona, USA) (n = 10) and NiTi rotary PathFiles ISO #13, #16 and #19 (Dentsply, Sirona, Switzerland) (n = 10). The time required to establish the glide path was measured with an iPhone stopwatch (Apple Inc. Cupertino, California). The images of the apical segment of canals before and after glide path preparation were taken under the stereomicroscope (Boeco BSZ-405, Germany), and then images were analyzed and processed with Scopeimage 9.0 (Teleskop, Austria). Statistical analysis was performed with the Mann-Whitney test at the level of significance 5% (a = 0.05). Results: A statistically significant difference was observed in terms of the time required for glide path preparation. The mean total time for glide path preparation was significantly longer with K-files (382 ± 62 s) than with PathFile (200 ± 11 s) (p < 0.05). A statistically significant difference in terms of changing the morphology of the apical part of the canal (p > 0.05) was not observed. The difference in the diameter of the root canal was at the limit of statistical significance (p ≈ 0.05). Conclusion: Instrumentation with NiTi rotary PathFiles reduces the time required for glide path preparation. Preparing endodontic space for rotary instrumentation with hand K-Files and rotary PathFiles leads to similar changes in the morphology of the apical segment. A slightly larger diameter of the root canal was measured after preparation with the hand K-files., Uvod: Uspostavljanje instrumentacione putanje je važan preduslov za bezbednu primenu mašinskih NiTi instrumentata tokom oblikovanja kanalskih sistema. Cilj: Cilj ovog rada je bio da se uporedi vreme potrebno za formiranje instrumentacione putanje, kao i promene u morfologiji apikalnog segmenta i prečniku apikalnog otvora kanala posle primene ručnih K-turpija i mašinskih PathFile instrumenata. Materijal i metode: Istraživanje je realizovano na 20 "endo trening" modela (Dentsply Maillefer, Switzerland). Instrumentaciona putanja je uspostavljena primenom ručnih K-turpija od nerđajućeg čelika (#10-15-20) (Dentsply, Sirona, Switzerland) (n = 10), odnosno mašinskih PathFile NiTi instrumenata (Dentsply, Sirona, Switzerland) (n = 10). Vreme potrebno za uspostavljanje instrumentacione putanje mereno je iPhone stopwatch (Apple Inc. Cupertino, California). Slike apikalnog segmenta kanala, pre i posle formiranja instrumentacione putanje, snimane su stereomikroskopom (Boeco BSZ-405, Germany), a zatim obrađene i analizirane u softverskom programu Scopeimage 9.0. Dobijeni podaci statistički su obrađeni Man-Vitnijevim (Mann-Whitney) testom (a = 0,05). Rezultati: Uočena je statistički značajna razlika u pogledu vremena potrebnog za uspostavljanje instrumentacione putanje između ručnih K-turpija (6 min. 22 s) i mašinskih PathFile instrumenata (3 min. 20 s) (p < 0,05). U pogledu morfologije apikalnog segmenta nisu uočene značajne razlike (p > 0,05). Razlike u prečniku apikalnog otvora bile su na granici statističke značajnosti (p ≈ 0,05). Zaključak: Primena mašinskih PathFile instrumenata rezultirala je bržim formiranjem instrumentacione putanje u poređenju sa ručnim K-turpijama. Obe ispitivane grupe instrumenata dovele su do sličnih promena u morfologiji apikalnog segmenta kanala. Nešto veći prečnik apikalnog otvora kanala izmeren je posle primene ručnih K-turpija.",
publisher = "Univerzitet u Beogradu - Medicinski fakultet, Beograd",
journal = "Medicinski podmladak",
title = "Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study, Formiranje instrumentacione putanje ručnim i mašinskim instrumentima u povijenim kanalima - in vitro studija",
volume = "74",
number = "2",
pages = "62-67",
doi = "10.5937/mp74-39415"
}
Stošić, M., Geler, K., Petrović, V.,& Jovanović-Medojević, M.. (2023). Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study. in Medicinski podmladak
Univerzitet u Beogradu - Medicinski fakultet, Beograd., 74(2), 62-67.
https://doi.org/10.5937/mp74-39415
Stošić M, Geler K, Petrović V, Jovanović-Medojević M. Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study. in Medicinski podmladak. 2023;74(2):62-67.
doi:10.5937/mp74-39415 .
Stošić, Miljan, Geler, Katarina, Petrović, Violeta, Jovanović-Medojević, Milica, "Glide path preparation with hand K-files and rotary PathFiles in simulated curved root canals: An in vitro study" in Medicinski podmladak, 74, no. 2 (2023):62-67,
https://doi.org/10.5937/mp74-39415 . .

Comparison of the efficiency of cleaning and disinfection protocols for hand endodontic instruments

Jovanović-Medojević, Milica; Opačić-Galić, Vanja; Geler, Katarina; Pavlica, Dušan

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2023)

TY  - JOUR
AU  - Jovanović-Medojević, Milica
AU  - Opačić-Galić, Vanja
AU  - Geler, Katarina
AU  - Pavlica, Dušan
PY  - 2023
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/3273
AB  - Background/Aim. There is no standard protocol for cleaning and disinfection of used endodontic instruments before their sterilization and reuse. The aim of this study was to determine the efficiency of the different methods of removing biological debris from different types of used hand stainless steel endodontic instruments. Methods. A total of 120 hand stainless steel endodontic instruments: KerrTM reamers, KerrTM files, and HedströmTM files, each forty ISO 25, used for root canal treatment on extracted teeth, were analyzed. The used instruments were divided into four groups based on different decontamination protocols. The evaluation of the efficiency of the cleaning methods was based on the evaluation of the amount of stained organic residues on the instruments (Van Gieson staining). Samples were analyzed by stereomicroscopy (x40). Statistical analysis was performed using the Mann-Whitney U test for the KerrTM reamers and HedströmTM files, while the One-Way ANOVA/Bonferroni test was used for the KerrTM files, at a significance level of 5% (a = 0.05). Results. Residual biological debris was observed on 93.3% of all the samples taken. The thermal disinfectant cleaning method showed the lowest contamination values for all types of instruments. The method of mechanical cleaning showed that the mean value of maximum biologic contamination (MBC) was 58.5% for the KerrTM reamers and 56.2% for KerrTM files, while for HedströmTM files, the highest MBC (50.2%) was shown by the ultrasonic method of cleaning. Conclusion. The use of a thermal disinfectant was the most efficient cleaning method for all three types of hand endodontic instruments.
AB  - Uvod/Cilj. Ne postoji standard za čišćenje i dezinfekciju upotrebljenih endodontskih instrumenata pre njihove sterilizacije i ponovnog korišćenja. Cilj rada bio je da se ustanovi efikasnost različitih metoda uklanjanja ostataka biološkog materijala sa radnih površina upotrebljenih ručnih endodontskih instrumenata od nerđajućeg čelika. Metode. Analizirano je ukupno 120 ručnih endodontskih instrumenata od nerđajućeg čelika: po četrdeset KerrTM proširivača, KerrTM turpija i HedströmTM turpija ISO 25, upotrebljenih za obradu kanala korena na ekstrahovanim zubima. Na osnovu protokola koji je korišćen za dekontaminaciju instrumenata, upotrebljeni instrumenti su podeljeni u četiri grupe. Procena efikasnosti korišćenih metoda čišćenja zasnovana je na proceni količine prebojenih organskih ostataka na instrumentima (bojenje po Van Gieson-u). Uzorci su analizirani stereomikroskopijom (x40). Statistička analiza dobijenih rezultata izvršena je MannWhitney U testom za KerrTM proširivače i HedströmTM turpije dok je za KerrTM turpije korišćen One-Way ANOVA/Bonferoni test, na nivou pouzdanosti od 5% (a = 0,05). Rezultati. Prisustvo rezidualnih ostataka biološkog materijala uočeno je na 93,3% svih analiziranih instrumenata. Metoda čišćenja toplotnim dezinfikatorom pokazala je najniže vrednosti kontaminacije za sve tipove instrumenata. Metoda mehaničkog čišćenja pokazala je da je srednja vrednost parametra maksimum biološke kontaminacije (MBK) bila 58,5% za KerrTM proširivače i 56,2% za KerrTM turpije, dok je za HedströmTM turpije najviša vrednost MBK (50,2%) bila posle ultrazvučne metode čišćenja instrumenata. Zaključak. Primena toplotnog dezinfikatora je najefikasnija metoda čišćenja za sva tri tipa ručnih endodontskih instrumenata.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Comparison of the efficiency of cleaning and disinfection protocols for hand endodontic instruments
T1  - Upoređivanje efikasnosti protokola čišćenja i dezinfekcije ručnih endodontskih instrumenata
VL  - 80
IS  - 7
SP  - 596
EP  - 603
DO  - 10.2298/VSP220913103J
ER  - 
@article{
author = "Jovanović-Medojević, Milica and Opačić-Galić, Vanja and Geler, Katarina and Pavlica, Dušan",
year = "2023",
abstract = "Background/Aim. There is no standard protocol for cleaning and disinfection of used endodontic instruments before their sterilization and reuse. The aim of this study was to determine the efficiency of the different methods of removing biological debris from different types of used hand stainless steel endodontic instruments. Methods. A total of 120 hand stainless steel endodontic instruments: KerrTM reamers, KerrTM files, and HedströmTM files, each forty ISO 25, used for root canal treatment on extracted teeth, were analyzed. The used instruments were divided into four groups based on different decontamination protocols. The evaluation of the efficiency of the cleaning methods was based on the evaluation of the amount of stained organic residues on the instruments (Van Gieson staining). Samples were analyzed by stereomicroscopy (x40). Statistical analysis was performed using the Mann-Whitney U test for the KerrTM reamers and HedströmTM files, while the One-Way ANOVA/Bonferroni test was used for the KerrTM files, at a significance level of 5% (a = 0.05). Results. Residual biological debris was observed on 93.3% of all the samples taken. The thermal disinfectant cleaning method showed the lowest contamination values for all types of instruments. The method of mechanical cleaning showed that the mean value of maximum biologic contamination (MBC) was 58.5% for the KerrTM reamers and 56.2% for KerrTM files, while for HedströmTM files, the highest MBC (50.2%) was shown by the ultrasonic method of cleaning. Conclusion. The use of a thermal disinfectant was the most efficient cleaning method for all three types of hand endodontic instruments., Uvod/Cilj. Ne postoji standard za čišćenje i dezinfekciju upotrebljenih endodontskih instrumenata pre njihove sterilizacije i ponovnog korišćenja. Cilj rada bio je da se ustanovi efikasnost različitih metoda uklanjanja ostataka biološkog materijala sa radnih površina upotrebljenih ručnih endodontskih instrumenata od nerđajućeg čelika. Metode. Analizirano je ukupno 120 ručnih endodontskih instrumenata od nerđajućeg čelika: po četrdeset KerrTM proširivača, KerrTM turpija i HedströmTM turpija ISO 25, upotrebljenih za obradu kanala korena na ekstrahovanim zubima. Na osnovu protokola koji je korišćen za dekontaminaciju instrumenata, upotrebljeni instrumenti su podeljeni u četiri grupe. Procena efikasnosti korišćenih metoda čišćenja zasnovana je na proceni količine prebojenih organskih ostataka na instrumentima (bojenje po Van Gieson-u). Uzorci su analizirani stereomikroskopijom (x40). Statistička analiza dobijenih rezultata izvršena je MannWhitney U testom za KerrTM proširivače i HedströmTM turpije dok je za KerrTM turpije korišćen One-Way ANOVA/Bonferoni test, na nivou pouzdanosti od 5% (a = 0,05). Rezultati. Prisustvo rezidualnih ostataka biološkog materijala uočeno je na 93,3% svih analiziranih instrumenata. Metoda čišćenja toplotnim dezinfikatorom pokazala je najniže vrednosti kontaminacije za sve tipove instrumenata. Metoda mehaničkog čišćenja pokazala je da je srednja vrednost parametra maksimum biološke kontaminacije (MBK) bila 58,5% za KerrTM proširivače i 56,2% za KerrTM turpije, dok je za HedströmTM turpije najviša vrednost MBK (50,2%) bila posle ultrazvučne metode čišćenja instrumenata. Zaključak. Primena toplotnog dezinfikatora je najefikasnija metoda čišćenja za sva tri tipa ručnih endodontskih instrumenata.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Comparison of the efficiency of cleaning and disinfection protocols for hand endodontic instruments, Upoređivanje efikasnosti protokola čišćenja i dezinfekcije ručnih endodontskih instrumenata",
volume = "80",
number = "7",
pages = "596-603",
doi = "10.2298/VSP220913103J"
}
Jovanović-Medojević, M., Opačić-Galić, V., Geler, K.,& Pavlica, D.. (2023). Comparison of the efficiency of cleaning and disinfection protocols for hand endodontic instruments. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 80(7), 596-603.
https://doi.org/10.2298/VSP220913103J
Jovanović-Medojević M, Opačić-Galić V, Geler K, Pavlica D. Comparison of the efficiency of cleaning and disinfection protocols for hand endodontic instruments. in Vojnosanitetski pregled. 2023;80(7):596-603.
doi:10.2298/VSP220913103J .
Jovanović-Medojević, Milica, Opačić-Galić, Vanja, Geler, Katarina, Pavlica, Dušan, "Comparison of the efficiency of cleaning and disinfection protocols for hand endodontic instruments" in Vojnosanitetski pregled, 80, no. 7 (2023):596-603,
https://doi.org/10.2298/VSP220913103J . .
1

Poređenje protokola čišćenja i dezinfekcije ručnih endodontskih instrumenta

Geler, Katarina

(Univerzitet u Beogradu, Stomatološki fakultet, 2021)

TY  - THES
AU  - Geler, Katarina
PY  - 2021
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/3044
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Poređenje protokola čišćenja i dezinfekcije ručnih endodontskih instrumenta
UR  - https://hdl.handle.net/21.15107/rcub_smile_3044
ER  - 
@misc{
author = "Geler, Katarina",
year = "2021",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Poređenje protokola čišćenja i dezinfekcije ručnih endodontskih instrumenta",
url = "https://hdl.handle.net/21.15107/rcub_smile_3044"
}
Geler, K.. (2021). Poređenje protokola čišćenja i dezinfekcije ručnih endodontskih instrumenta. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_3044
Geler K. Poređenje protokola čišćenja i dezinfekcije ručnih endodontskih instrumenta. 2021;.
https://hdl.handle.net/21.15107/rcub_smile_3044 .
Geler, Katarina, "Poređenje protokola čišćenja i dezinfekcije ručnih endodontskih instrumenta" (2021),
https://hdl.handle.net/21.15107/rcub_smile_3044 .