Đorđević, Igor

Link to this page

Authority KeyName Variants
orcid::0000-0003-2695-4577
  • Đorđević, Igor (21)
Projects

Author's Bibliography

Occlusal appliances: An alternative in pain treatment of temporomandibular disorders

Đorđević, Igor; Todorović, Ana; Lazić, Vojkan; Obradović-Đuričić, Kosovka; Milekić, Bojana; Stamenković, Dejan

(Srpsko lekarsko društvo, Beograd, 2019)

TY  - JOUR
AU  - Đorđević, Igor
AU  - Todorović, Ana
AU  - Lazić, Vojkan
AU  - Obradović-Đuričić, Kosovka
AU  - Milekić, Bojana
AU  - Stamenković, Dejan
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2471
AB  - Introduction/Objective The pain that originates from musculoskeletal structures of the mastication system is one of the symptoms belonging to the category of temporomandibular disorders or temporomandibular dysfunction (TMD). The objective of the research was to evaluate the effect of therapy with stabilizing occlusal splint in the control of painful symptoms of TMD in comparison with the effect of drug therapy. Methods Using standard Research Diagnostic Criteria for Temporomandibular Disorders diagnostic protocol proposed by Dworkin and LeResche, a group of 44 patients with painful TMD was included. The patients were divided into three treatment groups by random selection. The first group was treated with stabilization occlusal splint for a period of one month. In the two control groups, therapy with non-steroidal anti-inflammatory drug ibuprofen (Brufen, Mylan, Canonsburg, PA, USA) or a combination therapy of ibuprofen and diazepam, a medication from the benzodiazepine family (Diazepam, Hemofarm, Vršac, Serbia) was carried out over a period of three weeks. In order to assess the effects of the therapy with stabilizing occlusal splint and the drug therapy, before and after the therapy, pain intensity measurements were performed with visual analogue scale and digital pressure algometer. Results A significant reduction in the intensity of painful symptoms was achieved in all three therapeutic groups. No significant differences in the effectiveness of pain reduction between the proposed therapeutic modalities were noted. Conclusion The obtained results confirm that the therapy with stabilization occlusal splint is a valid procedure in the reduction of pain in patients with TMD.
AB  - Uvod/Cilj Bol porekla mišićno-skeletnih struktura mastikatornog sistema predstavlja jedan od simptoma koji pripadaju kategoriji temporomandibularnih poremećaja ili temporomandibularnih disfunkcija (TMD). Cilj istraživanja je bio da se proceni efekat terapije stabilizacionim okluzalnim splintom u kontroli bolnih simptoma TMD u poređenju sa efektom terapije lekovima. Metode Korišćenjem standardnog dijagnostičkog protokola (RDC/TMD) predloženog od strane Dvorkina i Lerešea, izdvojena je grupa od 44 bolesnika sa bolnim temporomandibularnim disfunkcijama. Bolesnici su podeljeni u tri terapijske grupe slučajnim izborom. Prva grupa je podvrgnuta terapiji stabilizacionim okluzalnim splintom u periodu od mesec dana. U dve kontrolne grupe je sprovedena terapija nesteroidnim antiinflamatornim lekom ibuprofenom (brufen, Mylan) ili kombinacijom ibuprofena i leka iz grupe benzodiazepina - diazepama (diazepam, Hemofarm) u periodu od tri nedelje. U cilju procene efekata terapije stabilizacionim okluzalnim splintom i terapije lekovima, pre i posle sprovedene terapije izvedena su merenja intenziteta bola vizuelnom analognom skalom i digitalnim pritisnim algometrom. Rezultati U sve tri terapijske grupe postignuto je značajno smanjenje intenziteta bolnih simptoma. Nisu zabeležene značajne razlike u uspešnosti smanjenja bola između predloženih terapijskih modaliteta. Zaključak Dobijeni rezultati potvrđuju da je terapija stabilizacionim okluzalnim splintom validna procedura u smanjenju bola kod bolesnika sa TMD.
PB  - Srpsko lekarsko društvo, Beograd
T2  - Srpski arhiv za celokupno lekarstvo
T1  - Occlusal appliances: An alternative in pain treatment of temporomandibular disorders
T1  - Okluzalni splint - alternativa u terapiji bolesnika sa temporomandibularnim disfunkcijama
VL  - 147
IS  - 9-10
SP  - 541
EP  - 546
DO  - 10.2298/SARH190118064D
ER  - 
@article{
author = "Đorđević, Igor and Todorović, Ana and Lazić, Vojkan and Obradović-Đuričić, Kosovka and Milekić, Bojana and Stamenković, Dejan",
year = "2019",
abstract = "Introduction/Objective The pain that originates from musculoskeletal structures of the mastication system is one of the symptoms belonging to the category of temporomandibular disorders or temporomandibular dysfunction (TMD). The objective of the research was to evaluate the effect of therapy with stabilizing occlusal splint in the control of painful symptoms of TMD in comparison with the effect of drug therapy. Methods Using standard Research Diagnostic Criteria for Temporomandibular Disorders diagnostic protocol proposed by Dworkin and LeResche, a group of 44 patients with painful TMD was included. The patients were divided into three treatment groups by random selection. The first group was treated with stabilization occlusal splint for a period of one month. In the two control groups, therapy with non-steroidal anti-inflammatory drug ibuprofen (Brufen, Mylan, Canonsburg, PA, USA) or a combination therapy of ibuprofen and diazepam, a medication from the benzodiazepine family (Diazepam, Hemofarm, Vršac, Serbia) was carried out over a period of three weeks. In order to assess the effects of the therapy with stabilizing occlusal splint and the drug therapy, before and after the therapy, pain intensity measurements were performed with visual analogue scale and digital pressure algometer. Results A significant reduction in the intensity of painful symptoms was achieved in all three therapeutic groups. No significant differences in the effectiveness of pain reduction between the proposed therapeutic modalities were noted. Conclusion The obtained results confirm that the therapy with stabilization occlusal splint is a valid procedure in the reduction of pain in patients with TMD., Uvod/Cilj Bol porekla mišićno-skeletnih struktura mastikatornog sistema predstavlja jedan od simptoma koji pripadaju kategoriji temporomandibularnih poremećaja ili temporomandibularnih disfunkcija (TMD). Cilj istraživanja je bio da se proceni efekat terapije stabilizacionim okluzalnim splintom u kontroli bolnih simptoma TMD u poređenju sa efektom terapije lekovima. Metode Korišćenjem standardnog dijagnostičkog protokola (RDC/TMD) predloženog od strane Dvorkina i Lerešea, izdvojena je grupa od 44 bolesnika sa bolnim temporomandibularnim disfunkcijama. Bolesnici su podeljeni u tri terapijske grupe slučajnim izborom. Prva grupa je podvrgnuta terapiji stabilizacionim okluzalnim splintom u periodu od mesec dana. U dve kontrolne grupe je sprovedena terapija nesteroidnim antiinflamatornim lekom ibuprofenom (brufen, Mylan) ili kombinacijom ibuprofena i leka iz grupe benzodiazepina - diazepama (diazepam, Hemofarm) u periodu od tri nedelje. U cilju procene efekata terapije stabilizacionim okluzalnim splintom i terapije lekovima, pre i posle sprovedene terapije izvedena su merenja intenziteta bola vizuelnom analognom skalom i digitalnim pritisnim algometrom. Rezultati U sve tri terapijske grupe postignuto je značajno smanjenje intenziteta bolnih simptoma. Nisu zabeležene značajne razlike u uspešnosti smanjenja bola između predloženih terapijskih modaliteta. Zaključak Dobijeni rezultati potvrđuju da je terapija stabilizacionim okluzalnim splintom validna procedura u smanjenju bola kod bolesnika sa TMD.",
publisher = "Srpsko lekarsko društvo, Beograd",
journal = "Srpski arhiv za celokupno lekarstvo",
title = "Occlusal appliances: An alternative in pain treatment of temporomandibular disorders, Okluzalni splint - alternativa u terapiji bolesnika sa temporomandibularnim disfunkcijama",
volume = "147",
number = "9-10",
pages = "541-546",
doi = "10.2298/SARH190118064D"
}
Đorđević, I., Todorović, A., Lazić, V., Obradović-Đuričić, K., Milekić, B.,& Stamenković, D.. (2019). Occlusal appliances: An alternative in pain treatment of temporomandibular disorders. in Srpski arhiv za celokupno lekarstvo
Srpsko lekarsko društvo, Beograd., 147(9-10), 541-546.
https://doi.org/10.2298/SARH190118064D
Đorđević I, Todorović A, Lazić V, Obradović-Đuričić K, Milekić B, Stamenković D. Occlusal appliances: An alternative in pain treatment of temporomandibular disorders. in Srpski arhiv za celokupno lekarstvo. 2019;147(9-10):541-546.
doi:10.2298/SARH190118064D .
Đorđević, Igor, Todorović, Ana, Lazić, Vojkan, Obradović-Đuričić, Kosovka, Milekić, Bojana, Stamenković, Dejan, "Occlusal appliances: An alternative in pain treatment of temporomandibular disorders" in Srpski arhiv za celokupno lekarstvo, 147, no. 9-10 (2019):541-546,
https://doi.org/10.2298/SARH190118064D . .
2
3
4

Biological complications of the cement-retained implantsupported restorations

Miličić-Lazić, Minja; Jakšić, Milica; Todorović, Ana; Đorđević, Igor; Lazić, Vojkan

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2019)

TY  - JOUR
AU  - Miličić-Lazić, Minja
AU  - Jakšić, Milica
AU  - Todorović, Ana
AU  - Đorđević, Igor
AU  - Lazić, Vojkan
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2426
AB  - Dental cements have been established in practice since 1878, and technological advances in the field of implant pros-thetics have directly influenced the development of materials in this area. Although the retention type of implant-supported restorations can be dual, it is nowadays known that the overall rate of technical complications is higher for cement-retained restorations by 2% over screw-retained restorations. Biological complications, including peri-implant mucositis, periimplantitis, bone loss around implants, soft-tissue recession and fistula suppuration, are also more frequent with cement-retained restorations. The most common of these, periimplantitis is often related to factors depending on a clinician.
AB  - Materijali za fiksiranje zubnih protetskih nadoknada utemeljeni su u stomatološkoj praksi od 1878. godine, a tehnološki napredak na polju implant-protetike direktno je uticao i na razvoj materijala u ovoj oblasti. Iako mehanizam vezivanja fiksnih nadoknada može biti dvojak, danas se zna da je ukupna stopa tehničkih komplikacija veća kod cementno retiniranih nadoknada za 2% u odnosnu na retenciju šrafom. Biološke komplikacije u koje se ubrajaju periimplantatni mukozitis, periimplantitis, gubitak kosti oko implantata, recesija mekih tkiva i pojava fistule, takođe su učestalije kod cementno retiniranih zubnih nadoknada. Najzastupljenija među njima, periimplantitis, često se dovodi u vezu sa "lekar-zavisnim" parametrima.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Biological complications of the cement-retained implantsupported restorations
T1  - Biološke komplikacije cementom retiniranih nadoknada na implantatima
VL  - 66
IS  - 4
SP  - 189
EP  - 195
DO  - 10.2478/sdj-2019-0020
ER  - 
@article{
author = "Miličić-Lazić, Minja and Jakšić, Milica and Todorović, Ana and Đorđević, Igor and Lazić, Vojkan",
year = "2019",
abstract = "Dental cements have been established in practice since 1878, and technological advances in the field of implant pros-thetics have directly influenced the development of materials in this area. Although the retention type of implant-supported restorations can be dual, it is nowadays known that the overall rate of technical complications is higher for cement-retained restorations by 2% over screw-retained restorations. Biological complications, including peri-implant mucositis, periimplantitis, bone loss around implants, soft-tissue recession and fistula suppuration, are also more frequent with cement-retained restorations. The most common of these, periimplantitis is often related to factors depending on a clinician., Materijali za fiksiranje zubnih protetskih nadoknada utemeljeni su u stomatološkoj praksi od 1878. godine, a tehnološki napredak na polju implant-protetike direktno je uticao i na razvoj materijala u ovoj oblasti. Iako mehanizam vezivanja fiksnih nadoknada može biti dvojak, danas se zna da je ukupna stopa tehničkih komplikacija veća kod cementno retiniranih nadoknada za 2% u odnosnu na retenciju šrafom. Biološke komplikacije u koje se ubrajaju periimplantatni mukozitis, periimplantitis, gubitak kosti oko implantata, recesija mekih tkiva i pojava fistule, takođe su učestalije kod cementno retiniranih zubnih nadoknada. Najzastupljenija među njima, periimplantitis, često se dovodi u vezu sa "lekar-zavisnim" parametrima.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Biological complications of the cement-retained implantsupported restorations, Biološke komplikacije cementom retiniranih nadoknada na implantatima",
volume = "66",
number = "4",
pages = "189-195",
doi = "10.2478/sdj-2019-0020"
}
Miličić-Lazić, M., Jakšić, M., Todorović, A., Đorđević, I.,& Lazić, V.. (2019). Biological complications of the cement-retained implantsupported restorations. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 66(4), 189-195.
https://doi.org/10.2478/sdj-2019-0020
Miličić-Lazić M, Jakšić M, Todorović A, Đorđević I, Lazić V. Biological complications of the cement-retained implantsupported restorations. in Stomatološki glasnik Srbije. 2019;66(4):189-195.
doi:10.2478/sdj-2019-0020 .
Miličić-Lazić, Minja, Jakšić, Milica, Todorović, Ana, Đorđević, Igor, Lazić, Vojkan, "Biological complications of the cement-retained implantsupported restorations" in Stomatološki glasnik Srbije, 66, no. 4 (2019):189-195,
https://doi.org/10.2478/sdj-2019-0020 . .

Stress assessment in patients with clinically diagnosed sleep bruxism

Miletić, Ana; Lazić, Zoran; Todorović, Ana; Đorđević, Igor; Popović, Danica; Lazić, Vojkan

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2018)

TY  - JOUR
AU  - Miletić, Ana
AU  - Lazić, Zoran
AU  - Todorović, Ana
AU  - Đorđević, Igor
AU  - Popović, Danica
AU  - Lazić, Vojkan
PY  - 2018
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2332
AB  - Background/Aim. Many studies investigated association between stress, anxiety or personality traits and sleep bruxism (SB), but results are still contradictory. We aimed to investigate whether there is a relation between clinically diagnosed sleep bruxism and salivary cortisol levels as one of the major stress biomarkers and to examine psychological factors and personality traits specific to sleep bruxism. Methods. A total of 23 sleep bruxism patients and 42 healthy non-sleep bruxism adults participated in this study. Diagnose of sleep-bruxism was assessed by self-report and clinical examination and also confirmed by bed-partner. Morning saliva was collected from all participants for analyses of the cortisol level. Sleep bruxism patients underwent a psychodiagnostic personality interpretation using the Minnesota Multiphasic Personality Inventory - MMPI-202 test. Results. Statistically significant difference between levels of morning salivary cortisol in the group of SB patients and the control group was recorded (t = 2.943, p  lt  0.01). Analysis of the personality profiles indicated that the sleep bruxism patients avoid contact with unpleasant feelings, especially depression, suppress the aggression and censor the expression of anger and rage. Conclusion. This study showed that patients with sleep bruxism have higher levels of salivary cortisol. Personality traits such as depression, hypomania and suppressed aggression were found to be common characteristics in patients with sleep bruxism. Present findings might support the hypothesis that sleep bruxism and psychological states such as stress may be related, but the cross-sectional nature of this study does not allow us to draw conclusions about the causal relationship between stress, personality traits and sleep bruxism.
AB  - Uvod/Cilj. Mnoge studije ispitivale su povezanost između stresa, anksioznosti, crta ličnosti i bruksizma, ali su rezultati i dalje kontradiktorni. Cilj ove studije bio je da se ispita da li postoji povezanost između klinički dijagnostikovanog bruksizma koji se javlja tokom spavanja i koncentracije kortizola u salivi koja se smatra jednim od glavnih biomarkera stresa, kao i da se ispitaju psihološki faktori i crte ličnosti osoba sa bruksizmom. Metode. Studija je obuhvatila 23 bolesnika sa bruksizmom i 42 zdrava ispitanika bez znakova bruksizma. Dijagnoza bruksizma uspostavljena je na osnovu spostvene izjave i kliničkog pregleda kao i potvrde partnera. Uzorci jutarnje pljuvačke prikupljani su radi analize kortizola. Bolesnici sa bruksizmom podvrgnuti su psihodijagnostičkom ispitivanju pomoću Minesota multifaznog testa ličnosti - MMPI-202. Rezultati. U grupi bolesnika sa bruksizmom registrovana je značajno veća koncentracija kortizola u pljuvačci u poređenju sa pacijentima bez znakova bruksizma (t = 2.943, p  lt  0.01). Psihodijagnostička interpretacija profila ličnosti pokazala je da ispitanike sa bruksizmom karakteriše izbegavanje kontakta sa neprijatnim osećanjima, posebno depresijom i potiskivanje agresivnosti, odnosno izražena autocenzura na otvoreno ispoljavanje ljutnje i besa. Zaključak. Kod bolesnika sa bruksizmom registrovane su povećane koncentracije kortizola u salivi. Psihodijagnostička analiza ukazuje da su depresija, hipomanija i supresija agresije izražene kod bolesnika sa bruksizmom. Nalazi bi mogli da podrže hipotezu povezanosti bruksizma u toku spavanja i stresa, ali priroda ove studije ne dozvoljava izvođenje zaključaka o uzročnoj povezanosti stresa, crta ličnosti i bruksizma u toku spavanja.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Stress assessment in patients with clinically diagnosed sleep bruxism
T1  - Procena stresa kod bolesnika sa klinički dijagnostikovanim bruksizmom
VL  - 75
IS  - 10
SP  - 1014
EP  - 1019
DO  - 10.2298/VSP160902029M
ER  - 
@article{
author = "Miletić, Ana and Lazić, Zoran and Todorović, Ana and Đorđević, Igor and Popović, Danica and Lazić, Vojkan",
year = "2018",
abstract = "Background/Aim. Many studies investigated association between stress, anxiety or personality traits and sleep bruxism (SB), but results are still contradictory. We aimed to investigate whether there is a relation between clinically diagnosed sleep bruxism and salivary cortisol levels as one of the major stress biomarkers and to examine psychological factors and personality traits specific to sleep bruxism. Methods. A total of 23 sleep bruxism patients and 42 healthy non-sleep bruxism adults participated in this study. Diagnose of sleep-bruxism was assessed by self-report and clinical examination and also confirmed by bed-partner. Morning saliva was collected from all participants for analyses of the cortisol level. Sleep bruxism patients underwent a psychodiagnostic personality interpretation using the Minnesota Multiphasic Personality Inventory - MMPI-202 test. Results. Statistically significant difference between levels of morning salivary cortisol in the group of SB patients and the control group was recorded (t = 2.943, p  lt  0.01). Analysis of the personality profiles indicated that the sleep bruxism patients avoid contact with unpleasant feelings, especially depression, suppress the aggression and censor the expression of anger and rage. Conclusion. This study showed that patients with sleep bruxism have higher levels of salivary cortisol. Personality traits such as depression, hypomania and suppressed aggression were found to be common characteristics in patients with sleep bruxism. Present findings might support the hypothesis that sleep bruxism and psychological states such as stress may be related, but the cross-sectional nature of this study does not allow us to draw conclusions about the causal relationship between stress, personality traits and sleep bruxism., Uvod/Cilj. Mnoge studije ispitivale su povezanost između stresa, anksioznosti, crta ličnosti i bruksizma, ali su rezultati i dalje kontradiktorni. Cilj ove studije bio je da se ispita da li postoji povezanost između klinički dijagnostikovanog bruksizma koji se javlja tokom spavanja i koncentracije kortizola u salivi koja se smatra jednim od glavnih biomarkera stresa, kao i da se ispitaju psihološki faktori i crte ličnosti osoba sa bruksizmom. Metode. Studija je obuhvatila 23 bolesnika sa bruksizmom i 42 zdrava ispitanika bez znakova bruksizma. Dijagnoza bruksizma uspostavljena je na osnovu spostvene izjave i kliničkog pregleda kao i potvrde partnera. Uzorci jutarnje pljuvačke prikupljani su radi analize kortizola. Bolesnici sa bruksizmom podvrgnuti su psihodijagnostičkom ispitivanju pomoću Minesota multifaznog testa ličnosti - MMPI-202. Rezultati. U grupi bolesnika sa bruksizmom registrovana je značajno veća koncentracija kortizola u pljuvačci u poređenju sa pacijentima bez znakova bruksizma (t = 2.943, p  lt  0.01). Psihodijagnostička interpretacija profila ličnosti pokazala je da ispitanike sa bruksizmom karakteriše izbegavanje kontakta sa neprijatnim osećanjima, posebno depresijom i potiskivanje agresivnosti, odnosno izražena autocenzura na otvoreno ispoljavanje ljutnje i besa. Zaključak. Kod bolesnika sa bruksizmom registrovane su povećane koncentracije kortizola u salivi. Psihodijagnostička analiza ukazuje da su depresija, hipomanija i supresija agresije izražene kod bolesnika sa bruksizmom. Nalazi bi mogli da podrže hipotezu povezanosti bruksizma u toku spavanja i stresa, ali priroda ove studije ne dozvoljava izvođenje zaključaka o uzročnoj povezanosti stresa, crta ličnosti i bruksizma u toku spavanja.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Stress assessment in patients with clinically diagnosed sleep bruxism, Procena stresa kod bolesnika sa klinički dijagnostikovanim bruksizmom",
volume = "75",
number = "10",
pages = "1014-1019",
doi = "10.2298/VSP160902029M"
}
Miletić, A., Lazić, Z., Todorović, A., Đorđević, I., Popović, D.,& Lazić, V.. (2018). Stress assessment in patients with clinically diagnosed sleep bruxism. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 75(10), 1014-1019.
https://doi.org/10.2298/VSP160902029M
Miletić A, Lazić Z, Todorović A, Đorđević I, Popović D, Lazić V. Stress assessment in patients with clinically diagnosed sleep bruxism. in Vojnosanitetski pregled. 2018;75(10):1014-1019.
doi:10.2298/VSP160902029M .
Miletić, Ana, Lazić, Zoran, Todorović, Ana, Đorđević, Igor, Popović, Danica, Lazić, Vojkan, "Stress assessment in patients with clinically diagnosed sleep bruxism" in Vojnosanitetski pregled, 75, no. 10 (2018):1014-1019,
https://doi.org/10.2298/VSP160902029M . .
8
2
5

Implant retained nasal epithesis: Case report

Todorović, Ana; Đorđević, Igor; Konstantinović, Vitomir; Popović, Danica; Lazić, Vojkan

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2017)

TY  - JOUR
AU  - Todorović, Ana
AU  - Đorđević, Igor
AU  - Konstantinović, Vitomir
AU  - Popović, Danica
AU  - Lazić, Vojkan
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2203
AB  - Nasal defects can occur as a result of head and neck trauma, or due to partial or complete ablation or resection of the tumor in the nasal area and surroundings. Smaller defects can be reconstructed surgically while large defects are mainly reconstructed combined surgically and prosthetically. The aim of this paper was to present prosthetic reconstruction of the nasal defect by colored vinyl polysiloxane prosthesis retained with craniofacial basal disc implants. An adequate aesthetics and stability of the prosthesis was achieved during mandible and mimic muscles movements.
AB  - Defekti nosa mogu nastati kao posledica traume glave i vrata ili usled delimične ili potpune ablacije, odnosno resekcije tumora predela nosa i okoline. Manji defekti nosa se rekonstruišu hirurški, dok se veliki defekti uglavnom rekonstruišu kombinovano, kako hirurški tako i protetski. Cilj ovoga rada bio je da se prikaže protetska rekonstrukcija defekta nosa protezom izrađenom od vinil-polisiloksana u boji sa retencijom preko kraniofacijalnih bazalnih disk-implantata. Ovakvom protetskom nadoknadom postignute su zadovoljavajuća estetika i stabilnost proteze pri pokretima mandibule i mimičnih mišića.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Implant retained nasal epithesis: Case report
T1  - Retencija proteze nosa pomoću implantata – prikaz slučaja
VL  - 64
IS  - 2
SP  - 94
EP  - 99
DO  - 10.1515/sdj-2017-0010
ER  - 
@article{
author = "Todorović, Ana and Đorđević, Igor and Konstantinović, Vitomir and Popović, Danica and Lazić, Vojkan",
year = "2017",
abstract = "Nasal defects can occur as a result of head and neck trauma, or due to partial or complete ablation or resection of the tumor in the nasal area and surroundings. Smaller defects can be reconstructed surgically while large defects are mainly reconstructed combined surgically and prosthetically. The aim of this paper was to present prosthetic reconstruction of the nasal defect by colored vinyl polysiloxane prosthesis retained with craniofacial basal disc implants. An adequate aesthetics and stability of the prosthesis was achieved during mandible and mimic muscles movements., Defekti nosa mogu nastati kao posledica traume glave i vrata ili usled delimične ili potpune ablacije, odnosno resekcije tumora predela nosa i okoline. Manji defekti nosa se rekonstruišu hirurški, dok se veliki defekti uglavnom rekonstruišu kombinovano, kako hirurški tako i protetski. Cilj ovoga rada bio je da se prikaže protetska rekonstrukcija defekta nosa protezom izrađenom od vinil-polisiloksana u boji sa retencijom preko kraniofacijalnih bazalnih disk-implantata. Ovakvom protetskom nadoknadom postignute su zadovoljavajuća estetika i stabilnost proteze pri pokretima mandibule i mimičnih mišića.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Implant retained nasal epithesis: Case report, Retencija proteze nosa pomoću implantata – prikaz slučaja",
volume = "64",
number = "2",
pages = "94-99",
doi = "10.1515/sdj-2017-0010"
}
Todorović, A., Đorđević, I., Konstantinović, V., Popović, D.,& Lazić, V.. (2017). Implant retained nasal epithesis: Case report. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 64(2), 94-99.
https://doi.org/10.1515/sdj-2017-0010
Todorović A, Đorđević I, Konstantinović V, Popović D, Lazić V. Implant retained nasal epithesis: Case report. in Stomatološki glasnik Srbije. 2017;64(2):94-99.
doi:10.1515/sdj-2017-0010 .
Todorović, Ana, Đorđević, Igor, Konstantinović, Vitomir, Popović, Danica, Lazić, Vojkan, "Implant retained nasal epithesis: Case report" in Stomatološki glasnik Srbije, 64, no. 2 (2017):94-99,
https://doi.org/10.1515/sdj-2017-0010 . .

Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis

Ivanjac, Filip; Konstantinović, Vitomir; Lazić, Vojkan; Đorđević, Igor; Ihde, Stefan

(Lippincott Williams & Wilkins, Philadelphia, 2016)

TY  - JOUR
AU  - Ivanjac, Filip
AU  - Konstantinović, Vitomir
AU  - Lazić, Vojkan
AU  - Đorđević, Igor
AU  - Ihde, Stefan
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2166
AB  - Implant stability is a principal precondition for the success of implant therapy. Extraoral implants (EO) are mainly used for anchoring of maxillofacial epithesis. However, assessment of implant stability is mostly based on principles derived from oral implants. The aim of this study was to investigate clinical stability of EO craniofacial disk implants (single, double, and triple) by resonance frequency analysis at different stages of the bone's healing. Twenty patients with orbital (11), nasal (5), and auricular (4) defects with 50 EO implants placed for epithesis anchorage were included. Implant stability was measured 3 times; after implant placement, at 3 months and at least after 6 months. A significant increase in implant stability values was noted between all of the measurements, except for triple-disk implants between third and sixth months, and screw implants between 0 and third months. Disk implants showed lower implant stability quotient (ISQ) values compared with screw implants. Triple-disk implants showed better stability compared with single and double-disk implants. Based on resonance frequency analysis values, disk implants could be safely loaded when their ISQ values are 38 (single disks), 47 (double disks), and 48 (triple disks). According to resonance frequency analysis, disk implant stability increased over time, which showed good osseointegration and increasing mineralization. Although EO screw implants showed higher ISQ values than disk implants, disk-type implants can be safely loaded even if lower values of stability are measured.
PB  - Lippincott Williams & Wilkins, Philadelphia
T2  - Journal of Craniofacial Surgery
T1  - Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis
VL  - 27
IS  - 2
SP  - E185
EP  - E189
DO  - 10.1097/SCS.0000000000002443
ER  - 
@article{
author = "Ivanjac, Filip and Konstantinović, Vitomir and Lazić, Vojkan and Đorđević, Igor and Ihde, Stefan",
year = "2016",
abstract = "Implant stability is a principal precondition for the success of implant therapy. Extraoral implants (EO) are mainly used for anchoring of maxillofacial epithesis. However, assessment of implant stability is mostly based on principles derived from oral implants. The aim of this study was to investigate clinical stability of EO craniofacial disk implants (single, double, and triple) by resonance frequency analysis at different stages of the bone's healing. Twenty patients with orbital (11), nasal (5), and auricular (4) defects with 50 EO implants placed for epithesis anchorage were included. Implant stability was measured 3 times; after implant placement, at 3 months and at least after 6 months. A significant increase in implant stability values was noted between all of the measurements, except for triple-disk implants between third and sixth months, and screw implants between 0 and third months. Disk implants showed lower implant stability quotient (ISQ) values compared with screw implants. Triple-disk implants showed better stability compared with single and double-disk implants. Based on resonance frequency analysis values, disk implants could be safely loaded when their ISQ values are 38 (single disks), 47 (double disks), and 48 (triple disks). According to resonance frequency analysis, disk implant stability increased over time, which showed good osseointegration and increasing mineralization. Although EO screw implants showed higher ISQ values than disk implants, disk-type implants can be safely loaded even if lower values of stability are measured.",
publisher = "Lippincott Williams & Wilkins, Philadelphia",
journal = "Journal of Craniofacial Surgery",
title = "Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis",
volume = "27",
number = "2",
pages = "E185-E189",
doi = "10.1097/SCS.0000000000002443"
}
Ivanjac, F., Konstantinović, V., Lazić, V., Đorđević, I.,& Ihde, S.. (2016). Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis. in Journal of Craniofacial Surgery
Lippincott Williams & Wilkins, Philadelphia., 27(2), E185-E189.
https://doi.org/10.1097/SCS.0000000000002443
Ivanjac F, Konstantinović V, Lazić V, Đorđević I, Ihde S. Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis. in Journal of Craniofacial Surgery. 2016;27(2):E185-E189.
doi:10.1097/SCS.0000000000002443 .
Ivanjac, Filip, Konstantinović, Vitomir, Lazić, Vojkan, Đorđević, Igor, Ihde, Stefan, "Assessment of Stability of Craniofacial Implants by Resonant Frequency Analysis" in Journal of Craniofacial Surgery, 27, no. 2 (2016):E185-E189,
https://doi.org/10.1097/SCS.0000000000002443 . .
3
5
3
5

Fiber reinforced composite bridge as a replacement for missing upper permanent lateral incisor: A case report

Todorović, Ana; Popović, Danica; Đorđević, Igor; Lazić, Vojkan

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2016)

TY  - JOUR
AU  - Todorović, Ana
AU  - Popović, Danica
AU  - Đorđević, Igor
AU  - Lazić, Vojkan
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2104
AB  - Hypodontia of upper lateral incisors is significant aesthetic problem in young people. Ideal solution to this problem would be an implant placement, but there is a problem of unfinished growth and development. It is therefore necessary to have a temporary solution in order to maintain normal stomatognathic system functions and solve aesthetic problems until the final restoration is placed. The aim of this study was to show the possibility of treating hypodontia of permanent upper lateral incisors by creating adhesive bridge in one visit. A 15-year-old patient was referred to the Department for Prosthodontics, School of Dental Medicine in Belgrade with hypodontia of permanent upper lateral incisors. The patient had braces until 14 years of age after which she was rehabilitated with partial denture that was neither aesthetically nor functionally acceptable solution for her and significantly affected her emotional security. The adhesive bridge was made using GC composite fibers and a set of GC composite materials for the purpose of temporary replacement of missing teeth. This treatment provided good functional and aesthetic results. The space for the placement of two endosseous implants is preserved and a period of adaptation positively influenced the patient's social development in sensitive adolescent age.
AB  - Hipodoncija gornjih lateralnih sekutića predstavlja značajan estetski problem mladih osoba. Idealno rešenje ovog problema bi predstavljala ugradnja implantata i izrada krunice, ali je prisutan problem nezavršenog rasta i razvoja. Zbog toga je neophodno izraditi privremeno rešenje, kako bi se normalno odvijale funkcije stomatognatnog sistema i rešili estetski problemi, sve do izrade trajne nadoknade. Cilj ovog rada bio je da se prikaže mogućnost zbrinjavanja hipodoncije stalnih gornjih lateralnih sekutića izradom adhezivnog mosta u jednoj poseti. Pacijentkinja starosti 15 godina javila se na Kliniku za stomatološku protetiku Stomatološkog fakulteta u Beogradu sa hipodoncijom stalnih gornjih lateralnih sekutića. U anamnezi je navela da je nosila fiksni ortodontski aparat do svoje 14. godine, a potom bila rehabilitovana parcijalnom pločastom protezom, kojom nije bila zadovoljna ni estetski ni funkcionalno, što je značajno uticalo na njenu emocionalnu nesigurnost. Izrađen je adhezivni most primenom GC kompozitnih vlakana i setom GC kompozitnih materijala sa ciljem privremene nadoknade neizniklih zuba. Primenjenom terapijom je postignut zadovoljavajući funkcionalni i estetski rezultat do momenta realizacije trajnog protetskog rešenja. Sačuvan je prostor za ugradnju dva endosealna implantata, a period adaptacije je pozitvno uticao na socijalni razvoj osobe u osetljivom pubertetskom dobu. .
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Fiber reinforced composite bridge as a replacement for missing upper permanent lateral incisor: A case report
T1  - Vlaknima ojačan kompozitni most kao zamena za neiznikli gornji stalni lateralni sekutić - prikaz bolesnika
VL  - 63
IS  - 3
SP  - 133
EP  - 138
DO  - 10.1515/sdj-2016-0014
ER  - 
@article{
author = "Todorović, Ana and Popović, Danica and Đorđević, Igor and Lazić, Vojkan",
year = "2016",
abstract = "Hypodontia of upper lateral incisors is significant aesthetic problem in young people. Ideal solution to this problem would be an implant placement, but there is a problem of unfinished growth and development. It is therefore necessary to have a temporary solution in order to maintain normal stomatognathic system functions and solve aesthetic problems until the final restoration is placed. The aim of this study was to show the possibility of treating hypodontia of permanent upper lateral incisors by creating adhesive bridge in one visit. A 15-year-old patient was referred to the Department for Prosthodontics, School of Dental Medicine in Belgrade with hypodontia of permanent upper lateral incisors. The patient had braces until 14 years of age after which she was rehabilitated with partial denture that was neither aesthetically nor functionally acceptable solution for her and significantly affected her emotional security. The adhesive bridge was made using GC composite fibers and a set of GC composite materials for the purpose of temporary replacement of missing teeth. This treatment provided good functional and aesthetic results. The space for the placement of two endosseous implants is preserved and a period of adaptation positively influenced the patient's social development in sensitive adolescent age., Hipodoncija gornjih lateralnih sekutića predstavlja značajan estetski problem mladih osoba. Idealno rešenje ovog problema bi predstavljala ugradnja implantata i izrada krunice, ali je prisutan problem nezavršenog rasta i razvoja. Zbog toga je neophodno izraditi privremeno rešenje, kako bi se normalno odvijale funkcije stomatognatnog sistema i rešili estetski problemi, sve do izrade trajne nadoknade. Cilj ovog rada bio je da se prikaže mogućnost zbrinjavanja hipodoncije stalnih gornjih lateralnih sekutića izradom adhezivnog mosta u jednoj poseti. Pacijentkinja starosti 15 godina javila se na Kliniku za stomatološku protetiku Stomatološkog fakulteta u Beogradu sa hipodoncijom stalnih gornjih lateralnih sekutića. U anamnezi je navela da je nosila fiksni ortodontski aparat do svoje 14. godine, a potom bila rehabilitovana parcijalnom pločastom protezom, kojom nije bila zadovoljna ni estetski ni funkcionalno, što je značajno uticalo na njenu emocionalnu nesigurnost. Izrađen je adhezivni most primenom GC kompozitnih vlakana i setom GC kompozitnih materijala sa ciljem privremene nadoknade neizniklih zuba. Primenjenom terapijom je postignut zadovoljavajući funkcionalni i estetski rezultat do momenta realizacije trajnog protetskog rešenja. Sačuvan je prostor za ugradnju dva endosealna implantata, a period adaptacije je pozitvno uticao na socijalni razvoj osobe u osetljivom pubertetskom dobu. .",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Fiber reinforced composite bridge as a replacement for missing upper permanent lateral incisor: A case report, Vlaknima ojačan kompozitni most kao zamena za neiznikli gornji stalni lateralni sekutić - prikaz bolesnika",
volume = "63",
number = "3",
pages = "133-138",
doi = "10.1515/sdj-2016-0014"
}
Todorović, A., Popović, D., Đorđević, I.,& Lazić, V.. (2016). Fiber reinforced composite bridge as a replacement for missing upper permanent lateral incisor: A case report. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 63(3), 133-138.
https://doi.org/10.1515/sdj-2016-0014
Todorović A, Popović D, Đorđević I, Lazić V. Fiber reinforced composite bridge as a replacement for missing upper permanent lateral incisor: A case report. in Stomatološki glasnik Srbije. 2016;63(3):133-138.
doi:10.1515/sdj-2016-0014 .
Todorović, Ana, Popović, Danica, Đorđević, Igor, Lazić, Vojkan, "Fiber reinforced composite bridge as a replacement for missing upper permanent lateral incisor: A case report" in Stomatološki glasnik Srbije, 63, no. 3 (2016):133-138,
https://doi.org/10.1515/sdj-2016-0014 . .
1

Synthesis and characterization of hardened cu-fe-ni-p alloy

Brovc, G.; Drazić, G.; Karpe, B.; Đorđević, Igor; Lojen, Gorazd; Kosec, Borut; Bizjak, M.

(Faculty of Metallurgy, 2015)

TY  - JOUR
AU  - Brovc, G.
AU  - Drazić, G.
AU  - Karpe, B.
AU  - Đorđević, Igor
AU  - Lojen, Gorazd
AU  - Kosec, Borut
AU  - Bizjak, M.
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2061
AB  - In the manufacturing industry of electrical contacts, the prohibition of the use of toxic metals (Cd, Be), and desire to avoid the alloying with precious metals (Ag) has created a need for new alloys with good electrical conductivity and high mechanical properties at elevated temperatures. As a potentially useful material for this purpose, we have analyzed the continuously cast Cu-Fe-Ni-P alloy in various heat treatment conditions. Sequence of phase transformations during heat treatment was followed by 4 point D.C. electrical resistivity measuring method, and analyzed by scanning (SEM) and transmission (TEM) electron microscopy. Measurements of Vickers hardness and electrical conductivity after various heat treatment procedures indicate on high potential of Cu-Fe-Ni-P alloys as a material for electrical contacts.
PB  - Faculty of Metallurgy
T2  - Metalurgija
T1  - Synthesis and characterization of hardened cu-fe-ni-p alloy
VL  - 54
IS  - 1
SP  - 51
EP  - 54
UR  - https://hdl.handle.net/21.15107/rcub_smile_2061
ER  - 
@article{
author = "Brovc, G. and Drazić, G. and Karpe, B. and Đorđević, Igor and Lojen, Gorazd and Kosec, Borut and Bizjak, M.",
year = "2015",
abstract = "In the manufacturing industry of electrical contacts, the prohibition of the use of toxic metals (Cd, Be), and desire to avoid the alloying with precious metals (Ag) has created a need for new alloys with good electrical conductivity and high mechanical properties at elevated temperatures. As a potentially useful material for this purpose, we have analyzed the continuously cast Cu-Fe-Ni-P alloy in various heat treatment conditions. Sequence of phase transformations during heat treatment was followed by 4 point D.C. electrical resistivity measuring method, and analyzed by scanning (SEM) and transmission (TEM) electron microscopy. Measurements of Vickers hardness and electrical conductivity after various heat treatment procedures indicate on high potential of Cu-Fe-Ni-P alloys as a material for electrical contacts.",
publisher = "Faculty of Metallurgy",
journal = "Metalurgija",
title = "Synthesis and characterization of hardened cu-fe-ni-p alloy",
volume = "54",
number = "1",
pages = "51-54",
url = "https://hdl.handle.net/21.15107/rcub_smile_2061"
}
Brovc, G., Drazić, G., Karpe, B., Đorđević, I., Lojen, G., Kosec, B.,& Bizjak, M.. (2015). Synthesis and characterization of hardened cu-fe-ni-p alloy. in Metalurgija
Faculty of Metallurgy., 54(1), 51-54.
https://hdl.handle.net/21.15107/rcub_smile_2061
Brovc G, Drazić G, Karpe B, Đorđević I, Lojen G, Kosec B, Bizjak M. Synthesis and characterization of hardened cu-fe-ni-p alloy. in Metalurgija. 2015;54(1):51-54.
https://hdl.handle.net/21.15107/rcub_smile_2061 .
Brovc, G., Drazić, G., Karpe, B., Đorđević, Igor, Lojen, Gorazd, Kosec, Borut, Bizjak, M., "Synthesis and characterization of hardened cu-fe-ni-p alloy" in Metalurgija, 54, no. 1 (2015):51-54,
https://hdl.handle.net/21.15107/rcub_smile_2061 .
3
3

Contouring the emergence profile of peri-implant soft tissue by provisionals on implants: Case report

Lazić, Vojkan; Todorović, Ana; Đorđević, Igor; Milošević, Nataša; Popović, Danica; Miletić, Ana

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2015)

TY  - JOUR
AU  - Lazić, Vojkan
AU  - Todorović, Ana
AU  - Đorđević, Igor
AU  - Milošević, Nataša
AU  - Popović, Danica
AU  - Miletić, Ana
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2054
AB  - Aesthetic outcome of implant therapy involves the appropriate architecture of peri-implant soft tissue and interdental papilla. The dynamic compression technique of soft tissue is mentioned in contemporary literature as one of the methods for achieving optimal emergence profile. The aim of this case report was to present soft tissue prosthetic modeling with temporary crowns on implants for obtaining an emergence profile of final restoration. A 25-year-old female patient with missing left maxillary central incisor was referred to the Department of Oral Surgery School of Dental Medicine University in Belgrade for dental implant placement. After detailed planning, implant placement of Straumann Bone level implant NC O 3, 3×12 mm (StraumannR Bone Level NC), in the position of 21 was performed. Upon completion of osseointegration period, screw retained laboratory temporary crown was fabricated. During the next 3 months emergence profile was scalloped by creating additional pressure on the soft tissue with periodic adding the composite resin material to a temporary crown. The created emergence profile was transferred to the master cast by using customized impression coping, making possible fabrication of the final implant restoration according to the design made with provisional restoration. Soft tissue conditioning using temporary dental restorations on implants presents a non-invasive method with predictable aesthetic result.
AB  - Estetski uspeh implantološke terapije podrazumeva odgovarajuću arhitekturu periimplantatnih mekih tkiva i interdentalne papile. Tehnika dinamičke kompresije mekih tkiva pominje se u savremenoj literaturi kao jedna od metoda za postizanje optimalnog izlaznog profila. Cilj ovog rada je bio da se predstavi mogućnost protetičkog modelovanja mekih tkiva zubnom nadoknadom na implantatu za dobijanje izlaznog profila definitivne nadoknade. Žena stara 25 godina sa nedostatkom centralnog sekutića u gornjoj vilici s leve strane upućena je na Kliniku za oralnu hirurgiju Stomatološkog fakulteta Univerziteta u Beogradu radi ugradnje implantata. Posle detaljnog planiranja, u predelu zuba 21 ugrađen je Straumann Bone level implant NC O 3,3×12,0 mm (Straumann® Bone Level NC). Po završenom periodu oseointegracije izrađena je laboratorijska privremena krunica retinirana zavrtnjem. Tokom sledeća tri meseca izlazni profil je oblikovan periodičnim stvaranjem dodatnog pritiska na meka tkiva dodavanjem kompozitnog materijala na privremenu krunicu. Izlazni mekotkivni profil je pomoću individualizovanog transfera pozicije implantata prenet na radni model, što je omogućilo izradu konačne keramičke hibridne krunice prema dizajnu koji je kreiran privremenom nadoknadom. Priprema mekih tkiva privremenim zubnim nadoknadama na implantatima je neinvazivna klinička metoda s predvidljivim estetskim rezultatom i zadovoljavajućom visinom i širinom interdentalne papile.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Contouring the emergence profile of peri-implant soft tissue by provisionals on implants: Case report
T1  - Oblikovanje mekih tkiva privremenim zubnim nadoknadama na implantatima - prikaz slučaja
VL  - 62
IS  - 4
SP  - 196
EP  - 201
DO  - 10.1515/sdj-2015-0020
ER  - 
@article{
author = "Lazić, Vojkan and Todorović, Ana and Đorđević, Igor and Milošević, Nataša and Popović, Danica and Miletić, Ana",
year = "2015",
abstract = "Aesthetic outcome of implant therapy involves the appropriate architecture of peri-implant soft tissue and interdental papilla. The dynamic compression technique of soft tissue is mentioned in contemporary literature as one of the methods for achieving optimal emergence profile. The aim of this case report was to present soft tissue prosthetic modeling with temporary crowns on implants for obtaining an emergence profile of final restoration. A 25-year-old female patient with missing left maxillary central incisor was referred to the Department of Oral Surgery School of Dental Medicine University in Belgrade for dental implant placement. After detailed planning, implant placement of Straumann Bone level implant NC O 3, 3×12 mm (StraumannR Bone Level NC), in the position of 21 was performed. Upon completion of osseointegration period, screw retained laboratory temporary crown was fabricated. During the next 3 months emergence profile was scalloped by creating additional pressure on the soft tissue with periodic adding the composite resin material to a temporary crown. The created emergence profile was transferred to the master cast by using customized impression coping, making possible fabrication of the final implant restoration according to the design made with provisional restoration. Soft tissue conditioning using temporary dental restorations on implants presents a non-invasive method with predictable aesthetic result., Estetski uspeh implantološke terapije podrazumeva odgovarajuću arhitekturu periimplantatnih mekih tkiva i interdentalne papile. Tehnika dinamičke kompresije mekih tkiva pominje se u savremenoj literaturi kao jedna od metoda za postizanje optimalnog izlaznog profila. Cilj ovog rada je bio da se predstavi mogućnost protetičkog modelovanja mekih tkiva zubnom nadoknadom na implantatu za dobijanje izlaznog profila definitivne nadoknade. Žena stara 25 godina sa nedostatkom centralnog sekutića u gornjoj vilici s leve strane upućena je na Kliniku za oralnu hirurgiju Stomatološkog fakulteta Univerziteta u Beogradu radi ugradnje implantata. Posle detaljnog planiranja, u predelu zuba 21 ugrađen je Straumann Bone level implant NC O 3,3×12,0 mm (Straumann® Bone Level NC). Po završenom periodu oseointegracije izrađena je laboratorijska privremena krunica retinirana zavrtnjem. Tokom sledeća tri meseca izlazni profil je oblikovan periodičnim stvaranjem dodatnog pritiska na meka tkiva dodavanjem kompozitnog materijala na privremenu krunicu. Izlazni mekotkivni profil je pomoću individualizovanog transfera pozicije implantata prenet na radni model, što je omogućilo izradu konačne keramičke hibridne krunice prema dizajnu koji je kreiran privremenom nadoknadom. Priprema mekih tkiva privremenim zubnim nadoknadama na implantatima je neinvazivna klinička metoda s predvidljivim estetskim rezultatom i zadovoljavajućom visinom i širinom interdentalne papile.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Contouring the emergence profile of peri-implant soft tissue by provisionals on implants: Case report, Oblikovanje mekih tkiva privremenim zubnim nadoknadama na implantatima - prikaz slučaja",
volume = "62",
number = "4",
pages = "196-201",
doi = "10.1515/sdj-2015-0020"
}
Lazić, V., Todorović, A., Đorđević, I., Milošević, N., Popović, D.,& Miletić, A.. (2015). Contouring the emergence profile of peri-implant soft tissue by provisionals on implants: Case report. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 62(4), 196-201.
https://doi.org/10.1515/sdj-2015-0020
Lazić V, Todorović A, Đorđević I, Milošević N, Popović D, Miletić A. Contouring the emergence profile of peri-implant soft tissue by provisionals on implants: Case report. in Stomatološki glasnik Srbije. 2015;62(4):196-201.
doi:10.1515/sdj-2015-0020 .
Lazić, Vojkan, Todorović, Ana, Đorđević, Igor, Milošević, Nataša, Popović, Danica, Miletić, Ana, "Contouring the emergence profile of peri-implant soft tissue by provisionals on implants: Case report" in Stomatološki glasnik Srbije, 62, no. 4 (2015):196-201,
https://doi.org/10.1515/sdj-2015-0020 . .
2

Implant retained orbital prosthesis: Case report

Lazić, Vojkan; Konstantinović, Vitomir; Đorđević, Igor; Mihailović, Milinko

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2015)

TY  - JOUR
AU  - Lazić, Vojkan
AU  - Konstantinović, Vitomir
AU  - Đorđević, Igor
AU  - Mihailović, Milinko
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2041
AB  - Orbital defects after tumor resection (exenteration of orbital content) have been traditionally reconstructed with adhesive-retained craniofacial prostheses, also known as epistheses. The breakthrough in rehabilitation of facial defects with implant-retained prostheses has come with development of modern silicones (vynilpolysiloxane) and bone anchorage called osseointegration. Craniofacial implant technology offers improved reconstructive options to patients. This paper describes therapeutical procedure on a patient who received craniofacial implant-retained orbital prosthesis after orbital exenteration. The patient reported excellent prosthesis handling and stability.
AB  - Orbitalna oštećenja nastala resekcijom tumora (egzenteracija sadržaja orbite) se uglavnom rekonstruišu kraniofacijalnim protezama pričvršćenim adhezivima koji se nazivaju i epitezama. Izuzetne mogućnosti u rehabilitaciji defekata lica sa implantatno retiniranim protezama nastale su razvojem savremenih silikona (vinilpolisiloksana) i oseointegracijom implantata. Kraniofacijalna implantatna tehnologija danas pruža široke i poboljšane rekonstruktivne mogućnosti. U ovom radu je opisana terapijska procedura na pacijentu sa defektom orbite gde je izrađena implantatno retinirana orbitalna proteza. Pacijent je posle završene terapije bio zadovoljan zbog jednostavnog rukovanja i izuzetne stabilnosti proteze.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Implant retained orbital prosthesis: Case report
T1  - Implantatno retinirana orbitalna proteza - prikaz slučaja
VL  - 62
IS  - 2
SP  - 89
EP  - 94
DO  - 10.1515/sdj-2015-0010
ER  - 
@article{
author = "Lazić, Vojkan and Konstantinović, Vitomir and Đorđević, Igor and Mihailović, Milinko",
year = "2015",
abstract = "Orbital defects after tumor resection (exenteration of orbital content) have been traditionally reconstructed with adhesive-retained craniofacial prostheses, also known as epistheses. The breakthrough in rehabilitation of facial defects with implant-retained prostheses has come with development of modern silicones (vynilpolysiloxane) and bone anchorage called osseointegration. Craniofacial implant technology offers improved reconstructive options to patients. This paper describes therapeutical procedure on a patient who received craniofacial implant-retained orbital prosthesis after orbital exenteration. The patient reported excellent prosthesis handling and stability., Orbitalna oštećenja nastala resekcijom tumora (egzenteracija sadržaja orbite) se uglavnom rekonstruišu kraniofacijalnim protezama pričvršćenim adhezivima koji se nazivaju i epitezama. Izuzetne mogućnosti u rehabilitaciji defekata lica sa implantatno retiniranim protezama nastale su razvojem savremenih silikona (vinilpolisiloksana) i oseointegracijom implantata. Kraniofacijalna implantatna tehnologija danas pruža široke i poboljšane rekonstruktivne mogućnosti. U ovom radu je opisana terapijska procedura na pacijentu sa defektom orbite gde je izrađena implantatno retinirana orbitalna proteza. Pacijent je posle završene terapije bio zadovoljan zbog jednostavnog rukovanja i izuzetne stabilnosti proteze.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Implant retained orbital prosthesis: Case report, Implantatno retinirana orbitalna proteza - prikaz slučaja",
volume = "62",
number = "2",
pages = "89-94",
doi = "10.1515/sdj-2015-0010"
}
Lazić, V., Konstantinović, V., Đorđević, I.,& Mihailović, M.. (2015). Implant retained orbital prosthesis: Case report. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 62(2), 89-94.
https://doi.org/10.1515/sdj-2015-0010
Lazić V, Konstantinović V, Đorđević I, Mihailović M. Implant retained orbital prosthesis: Case report. in Stomatološki glasnik Srbije. 2015;62(2):89-94.
doi:10.1515/sdj-2015-0010 .
Lazić, Vojkan, Konstantinović, Vitomir, Đorđević, Igor, Mihailović, Milinko, "Implant retained orbital prosthesis: Case report" in Stomatološki glasnik Srbije, 62, no. 2 (2015):89-94,
https://doi.org/10.1515/sdj-2015-0010 . .

Assessment of implant stability by resonant frequency analysis

Konstantinović, Vitomir; Ivanjac, Filip; Lazić, Vojkan; Đorđević, Igor

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2015)

TY  - JOUR
AU  - Konstantinović, Vitomir
AU  - Ivanjac, Filip
AU  - Lazić, Vojkan
AU  - Đorđević, Igor
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2030
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Assessment of implant stability by resonant frequency analysis
T1  - Procena stabilnosti implantata analizom rezonantne frekvencije
VL  - 72
IS  - 2
SP  - 169
EP  - 174
DO  - 10.2298/VSP130801063K
ER  - 
@article{
author = "Konstantinović, Vitomir and Ivanjac, Filip and Lazić, Vojkan and Đorđević, Igor",
year = "2015",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Assessment of implant stability by resonant frequency analysis, Procena stabilnosti implantata analizom rezonantne frekvencije",
volume = "72",
number = "2",
pages = "169-174",
doi = "10.2298/VSP130801063K"
}
Konstantinović, V., Ivanjac, F., Lazić, V.,& Đorđević, I.. (2015). Assessment of implant stability by resonant frequency analysis. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 72(2), 169-174.
https://doi.org/10.2298/VSP130801063K
Konstantinović V, Ivanjac F, Lazić V, Đorđević I. Assessment of implant stability by resonant frequency analysis. in Vojnosanitetski pregled. 2015;72(2):169-174.
doi:10.2298/VSP130801063K .
Konstantinović, Vitomir, Ivanjac, Filip, Lazić, Vojkan, Đorđević, Igor, "Assessment of implant stability by resonant frequency analysis" in Vojnosanitetski pregled, 72, no. 2 (2015):169-174,
https://doi.org/10.2298/VSP130801063K . .
3
5
3
9

Association of Functional Polymorphisms in Matrix Metalloproteinase-9 and Glutathione S-Transferase T1 Genes with Temporomandibular Disorders

Milošević, Nataša; Nikolić, Nadja; Đorđević, Igor; Todorović, Ana; Lazić, Vojkan; Milašin, Jelena

(Quintessence Publishing Co Inc, Hanover Park, 2015)

TY  - JOUR
AU  - Milošević, Nataša
AU  - Nikolić, Nadja
AU  - Đorđević, Igor
AU  - Todorović, Ana
AU  - Lazić, Vojkan
AU  - Milašin, Jelena
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2021
AB  - Aims: To investigate the potential role of polymorphisms in matrix metalloproteinase-9 (MMP-9), glutathione S-transferase M1 (GSTM1) and T1 (GSTT1), and methylenetetrahydrofolate reductase (MTHFR) genes as risk factors for development of temporomandibular disorders (TMD) in a Serbian population. Methods: This case-control study included 282 subjects: 100 with TMD and 182 healthy controls. Genotyping was done by means of polymerase chain reaction (PCR)/restriction fragment length polymorphism (RFLP) for single nucleotide polymorphisms (SNPs) analysis (C-1562T MMP-9 and C677T MTHFR) or multiplex PCR and real-time PCR methods for deletion analysis (GSTM1, GSTT1) of DNA obtained from buccal swabs. The association of gene variants with TMD risk was determined by calculating odds ratios (OR) and their 95% confidence intervals (CI). Results: A statistically significant difference in genotype and allele frequencies was found between the TMD group and controls for the MMP-9 SNP. Heterozygotes (CT) were significantly more frequent in the TMD group than in the control group and carriers of the T allele had an approximately twofold increase of TMD risk (OR = 2.13, 95% CI = 1.24-3.67, P = .005). The null GSTT1 genotype as well as the combined non-null GSTM1/null GSTT1 were associated with lower risk of TMD (OR = 0.28, CI = 0.10-0.74, P = .004 and OR = 0.16, CI = 0.03-0.58, P  lt  .001, respectively). GSTM1 alone and MTHFR polymorphisms did not show an association with TMD. Conclusion: The C-1562T SNP in the promoter region of the MMP-9 gene, the GSTT1 null, as well as the combined GSTM1 non-null and GSTT1 null genotypes are modulators of TMD risk in a Serbian population.
PB  - Quintessence Publishing Co Inc, Hanover Park
T2  - Journal of Oral & Facial Pain & Headache
T1  - Association of Functional Polymorphisms in Matrix Metalloproteinase-9 and Glutathione S-Transferase T1 Genes with Temporomandibular Disorders
VL  - 29
IS  - 3
SP  - 279
EP  - 285
DO  - 10.11607/ofph.1343
ER  - 
@article{
author = "Milošević, Nataša and Nikolić, Nadja and Đorđević, Igor and Todorović, Ana and Lazić, Vojkan and Milašin, Jelena",
year = "2015",
abstract = "Aims: To investigate the potential role of polymorphisms in matrix metalloproteinase-9 (MMP-9), glutathione S-transferase M1 (GSTM1) and T1 (GSTT1), and methylenetetrahydrofolate reductase (MTHFR) genes as risk factors for development of temporomandibular disorders (TMD) in a Serbian population. Methods: This case-control study included 282 subjects: 100 with TMD and 182 healthy controls. Genotyping was done by means of polymerase chain reaction (PCR)/restriction fragment length polymorphism (RFLP) for single nucleotide polymorphisms (SNPs) analysis (C-1562T MMP-9 and C677T MTHFR) or multiplex PCR and real-time PCR methods for deletion analysis (GSTM1, GSTT1) of DNA obtained from buccal swabs. The association of gene variants with TMD risk was determined by calculating odds ratios (OR) and their 95% confidence intervals (CI). Results: A statistically significant difference in genotype and allele frequencies was found between the TMD group and controls for the MMP-9 SNP. Heterozygotes (CT) were significantly more frequent in the TMD group than in the control group and carriers of the T allele had an approximately twofold increase of TMD risk (OR = 2.13, 95% CI = 1.24-3.67, P = .005). The null GSTT1 genotype as well as the combined non-null GSTM1/null GSTT1 were associated with lower risk of TMD (OR = 0.28, CI = 0.10-0.74, P = .004 and OR = 0.16, CI = 0.03-0.58, P  lt  .001, respectively). GSTM1 alone and MTHFR polymorphisms did not show an association with TMD. Conclusion: The C-1562T SNP in the promoter region of the MMP-9 gene, the GSTT1 null, as well as the combined GSTM1 non-null and GSTT1 null genotypes are modulators of TMD risk in a Serbian population.",
publisher = "Quintessence Publishing Co Inc, Hanover Park",
journal = "Journal of Oral & Facial Pain & Headache",
title = "Association of Functional Polymorphisms in Matrix Metalloproteinase-9 and Glutathione S-Transferase T1 Genes with Temporomandibular Disorders",
volume = "29",
number = "3",
pages = "279-285",
doi = "10.11607/ofph.1343"
}
Milošević, N., Nikolić, N., Đorđević, I., Todorović, A., Lazić, V.,& Milašin, J.. (2015). Association of Functional Polymorphisms in Matrix Metalloproteinase-9 and Glutathione S-Transferase T1 Genes with Temporomandibular Disorders. in Journal of Oral & Facial Pain & Headache
Quintessence Publishing Co Inc, Hanover Park., 29(3), 279-285.
https://doi.org/10.11607/ofph.1343
Milošević N, Nikolić N, Đorđević I, Todorović A, Lazić V, Milašin J. Association of Functional Polymorphisms in Matrix Metalloproteinase-9 and Glutathione S-Transferase T1 Genes with Temporomandibular Disorders. in Journal of Oral & Facial Pain & Headache. 2015;29(3):279-285.
doi:10.11607/ofph.1343 .
Milošević, Nataša, Nikolić, Nadja, Đorđević, Igor, Todorović, Ana, Lazić, Vojkan, Milašin, Jelena, "Association of Functional Polymorphisms in Matrix Metalloproteinase-9 and Glutathione S-Transferase T1 Genes with Temporomandibular Disorders" in Journal of Oral & Facial Pain & Headache, 29, no. 3 (2015):279-285,
https://doi.org/10.11607/ofph.1343 . .
14
9
11

Hydroxyapatite coatings on cp-titanium grade-2 surfaces prepared with plasma spraying

Rudolf, Rebeka; Stamenković, Dragoslav; Aleksić, Zoran; Jenko, Monika; Đorđević, Igor; Todorović, Aleksandar; Jokanović, Vukoman; Raić, Karlo T.

(Inst Za Kovinske Materiale I In Tehnologie, Ljubjana, 2015)

TY  - JOUR
AU  - Rudolf, Rebeka
AU  - Stamenković, Dragoslav
AU  - Aleksić, Zoran
AU  - Jenko, Monika
AU  - Đorđević, Igor
AU  - Todorović, Aleksandar
AU  - Jokanović, Vukoman
AU  - Raić, Karlo T.
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1982
AB  - Thin hydroxyapatite coatings were produced on Cp-Titanium Grade-2 samples, with new high-voltage pulse-power equipment PJ-100 (Plasma Jet, Serbia) in order to get a more stable implant structure appropriate for further clinical applications. A comparative analysis of differently prepared surfaces of the Cp-Titanium Grade-2 samples was done before the hydroxyapatite was applied. Microstructural observation of the modified hydroxyapatite/implant surface was done using scanning-electron-microscopy imaging and Auger electron spectroscopy, with the aim of detecting the morphology and the elements contained in the new surfaces of the samples. The results confirmed that the surface of Cp-Titanium Grade-2 modified with hydroxyapatite is very similar to the bone structure.
PB  - Inst Za Kovinske Materiale I In Tehnologie, Ljubjana
T2  - Materiali in Tehnologije
T1  - Hydroxyapatite coatings on cp-titanium grade-2 surfaces prepared with plasma spraying
VL  - 49
IS  - 1
SP  - 81
EP  - 86
UR  - https://hdl.handle.net/21.15107/rcub_vinar_427
ER  - 
@article{
author = "Rudolf, Rebeka and Stamenković, Dragoslav and Aleksić, Zoran and Jenko, Monika and Đorđević, Igor and Todorović, Aleksandar and Jokanović, Vukoman and Raić, Karlo T.",
year = "2015",
abstract = "Thin hydroxyapatite coatings were produced on Cp-Titanium Grade-2 samples, with new high-voltage pulse-power equipment PJ-100 (Plasma Jet, Serbia) in order to get a more stable implant structure appropriate for further clinical applications. A comparative analysis of differently prepared surfaces of the Cp-Titanium Grade-2 samples was done before the hydroxyapatite was applied. Microstructural observation of the modified hydroxyapatite/implant surface was done using scanning-electron-microscopy imaging and Auger electron spectroscopy, with the aim of detecting the morphology and the elements contained in the new surfaces of the samples. The results confirmed that the surface of Cp-Titanium Grade-2 modified with hydroxyapatite is very similar to the bone structure.",
publisher = "Inst Za Kovinske Materiale I In Tehnologie, Ljubjana",
journal = "Materiali in Tehnologije",
title = "Hydroxyapatite coatings on cp-titanium grade-2 surfaces prepared with plasma spraying",
volume = "49",
number = "1",
pages = "81-86",
url = "https://hdl.handle.net/21.15107/rcub_vinar_427"
}
Rudolf, R., Stamenković, D., Aleksić, Z., Jenko, M., Đorđević, I., Todorović, A., Jokanović, V.,& Raić, K. T.. (2015). Hydroxyapatite coatings on cp-titanium grade-2 surfaces prepared with plasma spraying. in Materiali in Tehnologije
Inst Za Kovinske Materiale I In Tehnologie, Ljubjana., 49(1), 81-86.
https://hdl.handle.net/21.15107/rcub_vinar_427
Rudolf R, Stamenković D, Aleksić Z, Jenko M, Đorđević I, Todorović A, Jokanović V, Raić KT. Hydroxyapatite coatings on cp-titanium grade-2 surfaces prepared with plasma spraying. in Materiali in Tehnologije. 2015;49(1):81-86.
https://hdl.handle.net/21.15107/rcub_vinar_427 .
Rudolf, Rebeka, Stamenković, Dragoslav, Aleksić, Zoran, Jenko, Monika, Đorđević, Igor, Todorović, Aleksandar, Jokanović, Vukoman, Raić, Karlo T., "Hydroxyapatite coatings on cp-titanium grade-2 surfaces prepared with plasma spraying" in Materiali in Tehnologije, 49, no. 1 (2015):81-86,
https://hdl.handle.net/21.15107/rcub_vinar_427 .
2

Mechanical properties of the materials for bruxoguards

Lazić, Vojkan; Špadijer-Gostović, Aleksandra; Romcević, Neborga; Đorđević, Igor; Todorović, Ana; Milošević, Nataša; Rudolf, Rebeka

(Institute of Metals Technology, 2014)

TY  - JOUR
AU  - Lazić, Vojkan
AU  - Špadijer-Gostović, Aleksandra
AU  - Romcević, Neborga
AU  - Đorđević, Igor
AU  - Todorović, Ana
AU  - Milošević, Nataša
AU  - Rudolf, Rebeka
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1942
AB  - The aim of this study is to investigate the mechanical properties of polymethyl methacrylate (PMMA) and thermoplastic polycarbonate (TPC) materials in order to produce night bruxoguards. For this purpose we used a static tensile test. In the next step the microstructures of PMMA and TPC were observed. Within this framework special attention was paid to the examination of the tensile-test tube fracture surfaces for both materials. This approach revealed that PMMA is a brittle and TPC is a plastic material. Certain mechanical properties and a review of the crucial areas confirmed that the TPC material is extremely favourable for making occlusal splints.
PB  - Institute of Metals Technology
T2  - Materiali in Tehnologije
T1  - Mechanical properties of the materials for bruxoguards
VL  - 48
IS  - 6
SP  - 811
EP  - 816
UR  - https://hdl.handle.net/21.15107/rcub_smile_1942
ER  - 
@article{
author = "Lazić, Vojkan and Špadijer-Gostović, Aleksandra and Romcević, Neborga and Đorđević, Igor and Todorović, Ana and Milošević, Nataša and Rudolf, Rebeka",
year = "2014",
abstract = "The aim of this study is to investigate the mechanical properties of polymethyl methacrylate (PMMA) and thermoplastic polycarbonate (TPC) materials in order to produce night bruxoguards. For this purpose we used a static tensile test. In the next step the microstructures of PMMA and TPC were observed. Within this framework special attention was paid to the examination of the tensile-test tube fracture surfaces for both materials. This approach revealed that PMMA is a brittle and TPC is a plastic material. Certain mechanical properties and a review of the crucial areas confirmed that the TPC material is extremely favourable for making occlusal splints.",
publisher = "Institute of Metals Technology",
journal = "Materiali in Tehnologije",
title = "Mechanical properties of the materials for bruxoguards",
volume = "48",
number = "6",
pages = "811-816",
url = "https://hdl.handle.net/21.15107/rcub_smile_1942"
}
Lazić, V., Špadijer-Gostović, A., Romcević, N., Đorđević, I., Todorović, A., Milošević, N.,& Rudolf, R.. (2014). Mechanical properties of the materials for bruxoguards. in Materiali in Tehnologije
Institute of Metals Technology., 48(6), 811-816.
https://hdl.handle.net/21.15107/rcub_smile_1942
Lazić V, Špadijer-Gostović A, Romcević N, Đorđević I, Todorović A, Milošević N, Rudolf R. Mechanical properties of the materials for bruxoguards. in Materiali in Tehnologije. 2014;48(6):811-816.
https://hdl.handle.net/21.15107/rcub_smile_1942 .
Lazić, Vojkan, Špadijer-Gostović, Aleksandra, Romcević, Neborga, Đorđević, Igor, Todorović, Ana, Milošević, Nataša, Rudolf, Rebeka, "Mechanical properties of the materials for bruxoguards" in Materiali in Tehnologije, 48, no. 6 (2014):811-816,
https://hdl.handle.net/21.15107/rcub_smile_1942 .
1
1

Comparison of resorbable membranes for guided bone regeneration of human and bovine origin

Lazić, Zoran; Bubalo, Marija; Milović, Radomir; Matijević, Stevo; Magić, Marko; Đorđević, Igor

(Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd, 2014)

TY  - JOUR
AU  - Lazić, Zoran
AU  - Bubalo, Marija
AU  - Milović, Radomir
AU  - Matijević, Stevo
AU  - Magić, Marko
AU  - Đorđević, Igor
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1923
AB  - The properties of membranes for guided bone regeneration have been described by a number of authors. These involve biocompatibility, appropriate barrier features (mechanical prevention of soft tissue proliferation), tissue integration, immunologic neutrality, preservation of the space for new alveolar bone, and simplicity of application. Such membrane must hold out against the masticatory forces and tissue tension of the flap, and prevent the collapse of soft tissues and wound space reduction. The property of integration into the tissue guarantees wound stabilization and inhibits epithelial migration. The aim of this study was to compare and evaluate the influence of human resorbable demineralized membrane (RHDM) and bovine resorbable demineralized membrane (RBDM) on bone regeneration. The experiment, approved by the Ethical Committee, was performed on six dogs and conducted into three phases. Bone defects were created in all six dogs on the left side of the mandible, 8 weeks after extraction of the second, third and fourth premolar. One defect was covered with 200 μm thick RHDM, one with 200 μm thick RBDM, and the third defect was left empty (control defect). The pathohistological analysis was done two, four and six months after the surgery. In the third phase samples of bone tissue were taken and subjected to patohistological analysis. In all six dogs the defects treated with RHDM 200μm thick showed a higher level of bone regeneration in comparison with the defect treated with RBDM 200 μm thick and especially with the control defect. Our results demonstrated that the human membrane showed the least soft tissue ingrowth and promoted better bone formation at 6 months compared with a bovine one.
AB  - Svojstva membrane za vođenu koštanu regeneraciju opisali su brojni autori. Ona uključuju biokompatibilnost, odgovarajuću barijernu moć (mehaničko sprečavanje proliferacije mekog tkiva), tkivnu integraciju, imunološku inertnost, očuvanje prostora za novu alveolarnu kost i jednostavnost primene. Membrana mora da izdrži sile žvakanja i tkivne tenzije režnja, da spreči kolaps mekih tkiva i smanjenje prostora rane. Svojstvo tkivne integracije omogućava stabilizaciju rane i inhibiciju epitelne migracije. Cilj studije je bio da ispita uticaj humane resorptivne demineralizovane membrane (RHDM) i bovine resorptivne demineralizovane membrane (RBDM) na koštanu regeneraciju i da ih međusobno uporedi. Eksperimentalna studija rađena na 6 pasa rase nemački ovčar, sprovedena je u tri faze. U prvoj fazi izvršena je ekstrakcija drugog, trećeg i četvrtog premolara sa leve strane. Osam nedelja nakon ekstrakcije, formirana su tri defekta na levoj strani mandibule i prekrivena humanom membranom debljine 200μm, bovinom membranom debljine 200 μm a treći defekt je ostavljen prazan (kontrolni defekt). Patohistološka analiza rađena je nakon dva, četiri i šest meseci posle hirurške intervencije. U trećoj fazi uzorci koštanog tkiva podvrgnuti su patohistološkoj analizi. Kod svih 6 pasa, defekti prekriveni humanom membranom debljine 200 μm, pokazali su patohistološkom analizom znatno veći stepen koštane regeneracije u poređenju sa defektima prekrivenim sa bovinom membranom i naročito sa kontrolnim defektom. Naši rezultati su pokazali da je humana membrana pokazala najmanje prorastanje mekim tkivom i bolju koštanu regeneraciju nakon 6 meseci u poređenju sa bovinom.
PB  - Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd
T2  - Acta veterinaria
T1  - Comparison of resorbable membranes for guided bone regeneration of human and bovine origin
T1  - Poređenje resorptivnih membrana u vođenoj koštanoj regeneraciji humanog i bovinog porekla
VL  - 64
IS  - 4
SP  - 477
EP  - 492
DO  - 10.2478/acve-2014-0045
ER  - 
@article{
author = "Lazić, Zoran and Bubalo, Marija and Milović, Radomir and Matijević, Stevo and Magić, Marko and Đorđević, Igor",
year = "2014",
abstract = "The properties of membranes for guided bone regeneration have been described by a number of authors. These involve biocompatibility, appropriate barrier features (mechanical prevention of soft tissue proliferation), tissue integration, immunologic neutrality, preservation of the space for new alveolar bone, and simplicity of application. Such membrane must hold out against the masticatory forces and tissue tension of the flap, and prevent the collapse of soft tissues and wound space reduction. The property of integration into the tissue guarantees wound stabilization and inhibits epithelial migration. The aim of this study was to compare and evaluate the influence of human resorbable demineralized membrane (RHDM) and bovine resorbable demineralized membrane (RBDM) on bone regeneration. The experiment, approved by the Ethical Committee, was performed on six dogs and conducted into three phases. Bone defects were created in all six dogs on the left side of the mandible, 8 weeks after extraction of the second, third and fourth premolar. One defect was covered with 200 μm thick RHDM, one with 200 μm thick RBDM, and the third defect was left empty (control defect). The pathohistological analysis was done two, four and six months after the surgery. In the third phase samples of bone tissue were taken and subjected to patohistological analysis. In all six dogs the defects treated with RHDM 200μm thick showed a higher level of bone regeneration in comparison with the defect treated with RBDM 200 μm thick and especially with the control defect. Our results demonstrated that the human membrane showed the least soft tissue ingrowth and promoted better bone formation at 6 months compared with a bovine one., Svojstva membrane za vođenu koštanu regeneraciju opisali su brojni autori. Ona uključuju biokompatibilnost, odgovarajuću barijernu moć (mehaničko sprečavanje proliferacije mekog tkiva), tkivnu integraciju, imunološku inertnost, očuvanje prostora za novu alveolarnu kost i jednostavnost primene. Membrana mora da izdrži sile žvakanja i tkivne tenzije režnja, da spreči kolaps mekih tkiva i smanjenje prostora rane. Svojstvo tkivne integracije omogućava stabilizaciju rane i inhibiciju epitelne migracije. Cilj studije je bio da ispita uticaj humane resorptivne demineralizovane membrane (RHDM) i bovine resorptivne demineralizovane membrane (RBDM) na koštanu regeneraciju i da ih međusobno uporedi. Eksperimentalna studija rađena na 6 pasa rase nemački ovčar, sprovedena je u tri faze. U prvoj fazi izvršena je ekstrakcija drugog, trećeg i četvrtog premolara sa leve strane. Osam nedelja nakon ekstrakcije, formirana su tri defekta na levoj strani mandibule i prekrivena humanom membranom debljine 200μm, bovinom membranom debljine 200 μm a treći defekt je ostavljen prazan (kontrolni defekt). Patohistološka analiza rađena je nakon dva, četiri i šest meseci posle hirurške intervencije. U trećoj fazi uzorci koštanog tkiva podvrgnuti su patohistološkoj analizi. Kod svih 6 pasa, defekti prekriveni humanom membranom debljine 200 μm, pokazali su patohistološkom analizom znatno veći stepen koštane regeneracije u poređenju sa defektima prekrivenim sa bovinom membranom i naročito sa kontrolnim defektom. Naši rezultati su pokazali da je humana membrana pokazala najmanje prorastanje mekim tkivom i bolju koštanu regeneraciju nakon 6 meseci u poređenju sa bovinom.",
publisher = "Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd",
journal = "Acta veterinaria",
title = "Comparison of resorbable membranes for guided bone regeneration of human and bovine origin, Poređenje resorptivnih membrana u vođenoj koštanoj regeneraciji humanog i bovinog porekla",
volume = "64",
number = "4",
pages = "477-492",
doi = "10.2478/acve-2014-0045"
}
Lazić, Z., Bubalo, M., Milović, R., Matijević, S., Magić, M.,& Đorđević, I.. (2014). Comparison of resorbable membranes for guided bone regeneration of human and bovine origin. in Acta veterinaria
Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd., 64(4), 477-492.
https://doi.org/10.2478/acve-2014-0045
Lazić Z, Bubalo M, Milović R, Matijević S, Magić M, Đorđević I. Comparison of resorbable membranes for guided bone regeneration of human and bovine origin. in Acta veterinaria. 2014;64(4):477-492.
doi:10.2478/acve-2014-0045 .
Lazić, Zoran, Bubalo, Marija, Milović, Radomir, Matijević, Stevo, Magić, Marko, Đorđević, Igor, "Comparison of resorbable membranes for guided bone regeneration of human and bovine origin" in Acta veterinaria, 64, no. 4 (2014):477-492,
https://doi.org/10.2478/acve-2014-0045 . .
2
2
3

Transcutaneous electrical nerve stimulation therapy in reduction of orofacial pain

Đorđević, Igor; Lazić, Vojkan; Todorović, Ana; Čairović, Aleksandra; Veselinović, Valentina; Živković, Slavoljub

(Srpsko lekarsko društvo, Beograd, 2014)

TY  - JOUR
AU  - Đorđević, Igor
AU  - Lazić, Vojkan
AU  - Todorović, Ana
AU  - Čairović, Aleksandra
AU  - Veselinović, Valentina
AU  - Živković, Slavoljub
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1919
AB  - Introduction Patients with craniomandibular disorders suffer from hypertonic, fatigued and painful masticatory muscles. This condition can lead to limitation of mandibular jaw movements. All of these symptoms and signs are included in myofascial pain dysfunction syndrome. Transcutaneous electrical nerve stimulation (TENS) has been used for treatment of these patients. Objective The aim of this study was to assess the effect of TENS therapy on chronic pain reduction in patients with the muscular dysfunction symptom. Methods In order to evaluate the effect of TENS therapy before and after the treatment, Craniomandibular Index (Helkimo) was used. Pain intensity was measured by VAS. Patients had TENS treatment over two-week period. BURST TENS modality was used. Current intensity was individually adjusted. Results Two patients did not respond to TENS therapy. Complete pain reduction was recorded in 8 patients, while pain reduction was not significantly different after TENS therapy in 10 patients. Conclusion TENS therapy was confirmed as therapeutic procedure in orofacial muscle relaxation and pain reduction.
AB  - Uvod Hiperaktivnost mastikatorne muskulature, pojačan tonus mišića, zamor i bol, uz smanjenje opsega funkcijskih kretnji donje vilice, jesu znaci i simptomi miofascijalnog bolnog disfunkcijskog sindroma. Različiti terapijski modaliteti koriste se u lečenju, među kojima je i terapija transkutanom električnom nervnom stimulacijom (TENS). Cilj rada Cilj rada bila je klinička potvrda efekta terapije TENS na intenzitet hroničnog bola kod osoba sa simptomima disfunkcije mišića. Metode rada Radi procene terapije TENS korišćen je Helkimov kraniomandibularni indeks. Za kvantifikaciju intenziteta bola pre i posle lečenja primenjena je vizuelno-analogna skala (VAS). Pacijenti su podvrgnuti terapiji tri puta nedeljno u trajanju od 40 minuta tokom dve nedelje. Primenjen je modalitet burst (kratki impulsi dužine 10 ms i frekvencije 2-3 Hz) uz individualno podešavanje intenziteta strujnog impulsa. Rezultati Nisu primećeni negativni sporedni efekti terapije TENS. Potpuno smanjenje intenziteta bola zabeleženo je kod osam ispitanika. Kod 10 ispitanika smanjenje bola nije bilo značajno. Dva pacijenta nisu reagovala na primenjenu terapiju. Zaključak Terapija TENS se preporučuje osobama s manjim stepenom kraniomandibularnih disfunkcija bez obzira na intenzitet bola.
PB  - Srpsko lekarsko društvo, Beograd
T2  - Srpski arhiv za celokupno lekarstvo
T1  - Transcutaneous electrical nerve stimulation therapy in reduction of orofacial pain
T1  - Terapija orofacijalnog bola transkutanom električnom nervnom stimulacijom
VL  - 142
IS  - 3-4
SP  - 150
EP  - 154
DO  - 10.2298/SARH1404150D
ER  - 
@article{
author = "Đorđević, Igor and Lazić, Vojkan and Todorović, Ana and Čairović, Aleksandra and Veselinović, Valentina and Živković, Slavoljub",
year = "2014",
abstract = "Introduction Patients with craniomandibular disorders suffer from hypertonic, fatigued and painful masticatory muscles. This condition can lead to limitation of mandibular jaw movements. All of these symptoms and signs are included in myofascial pain dysfunction syndrome. Transcutaneous electrical nerve stimulation (TENS) has been used for treatment of these patients. Objective The aim of this study was to assess the effect of TENS therapy on chronic pain reduction in patients with the muscular dysfunction symptom. Methods In order to evaluate the effect of TENS therapy before and after the treatment, Craniomandibular Index (Helkimo) was used. Pain intensity was measured by VAS. Patients had TENS treatment over two-week period. BURST TENS modality was used. Current intensity was individually adjusted. Results Two patients did not respond to TENS therapy. Complete pain reduction was recorded in 8 patients, while pain reduction was not significantly different after TENS therapy in 10 patients. Conclusion TENS therapy was confirmed as therapeutic procedure in orofacial muscle relaxation and pain reduction., Uvod Hiperaktivnost mastikatorne muskulature, pojačan tonus mišića, zamor i bol, uz smanjenje opsega funkcijskih kretnji donje vilice, jesu znaci i simptomi miofascijalnog bolnog disfunkcijskog sindroma. Različiti terapijski modaliteti koriste se u lečenju, među kojima je i terapija transkutanom električnom nervnom stimulacijom (TENS). Cilj rada Cilj rada bila je klinička potvrda efekta terapije TENS na intenzitet hroničnog bola kod osoba sa simptomima disfunkcije mišića. Metode rada Radi procene terapije TENS korišćen je Helkimov kraniomandibularni indeks. Za kvantifikaciju intenziteta bola pre i posle lečenja primenjena je vizuelno-analogna skala (VAS). Pacijenti su podvrgnuti terapiji tri puta nedeljno u trajanju od 40 minuta tokom dve nedelje. Primenjen je modalitet burst (kratki impulsi dužine 10 ms i frekvencije 2-3 Hz) uz individualno podešavanje intenziteta strujnog impulsa. Rezultati Nisu primećeni negativni sporedni efekti terapije TENS. Potpuno smanjenje intenziteta bola zabeleženo je kod osam ispitanika. Kod 10 ispitanika smanjenje bola nije bilo značajno. Dva pacijenta nisu reagovala na primenjenu terapiju. Zaključak Terapija TENS se preporučuje osobama s manjim stepenom kraniomandibularnih disfunkcija bez obzira na intenzitet bola.",
publisher = "Srpsko lekarsko društvo, Beograd",
journal = "Srpski arhiv za celokupno lekarstvo",
title = "Transcutaneous electrical nerve stimulation therapy in reduction of orofacial pain, Terapija orofacijalnog bola transkutanom električnom nervnom stimulacijom",
volume = "142",
number = "3-4",
pages = "150-154",
doi = "10.2298/SARH1404150D"
}
Đorđević, I., Lazić, V., Todorović, A., Čairović, A., Veselinović, V.,& Živković, S.. (2014). Transcutaneous electrical nerve stimulation therapy in reduction of orofacial pain. in Srpski arhiv za celokupno lekarstvo
Srpsko lekarsko društvo, Beograd., 142(3-4), 150-154.
https://doi.org/10.2298/SARH1404150D
Đorđević I, Lazić V, Todorović A, Čairović A, Veselinović V, Živković S. Transcutaneous electrical nerve stimulation therapy in reduction of orofacial pain. in Srpski arhiv za celokupno lekarstvo. 2014;142(3-4):150-154.
doi:10.2298/SARH1404150D .
Đorđević, Igor, Lazić, Vojkan, Todorović, Ana, Čairović, Aleksandra, Veselinović, Valentina, Živković, Slavoljub, "Transcutaneous electrical nerve stimulation therapy in reduction of orofacial pain" in Srpski arhiv za celokupno lekarstvo, 142, no. 3-4 (2014):150-154,
https://doi.org/10.2298/SARH1404150D . .
2
1
2

Prosthetic therapy of the lateral facial defect

Lazić, Vojkan; Đorđević, Igor

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2012)

TY  - JOUR
AU  - Lazić, Vojkan
AU  - Đorđević, Igor
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1723
AB  - Introduction. Facial defects may arise as a result of head and neck trauma or facial tumor ablation. Minor defects can be reconstructed surgically while large defects usually need combined surgical and prosthetic reconstruction. The aim of this study was to present the prosthetic reconstruction of the lateral facial defect using facial colored acrylic prosthesis. Case Report. A male patient with a maxillary defect on the left side and a large lateral facial defect on the same side received an obturator prosthesis as well as a facial colored acrylic prosthesis (facial-orbit) retained by the glasses frame. Satisfied aesthetics was accomplished. However, the stability of the prostheses during mandibular movements could not be achieved which resulted in saliva leakage over the lips. Conclusion. Better functional and aesthetic outcome could be achieved by combined surgical and prosthetic treatment of such large facial defect.
AB  - Uvod. Defekti lica mogu nastati kao posledica povrede glave i vrata ili usled ablacije tumora predela lica ili okoline. Manji defekti se rekonstruišu hirurški, dok se velika oštećenja uglavnom rekonstruišu kombinovano, primenom hirurških i protetičkih metoda. Cilj rada je bio da se prikaže protetička rekonstrukcija lateralnog defekta lica facijalnom protezom od akrilata u boji. Prikaz bolesnika. Muškarcu s defektom levog dela maksile i velikim lateralnim defektom lica s iste strane izrađene su opturator- proteza i proteza lica (orbito-facijalna) od akrilata u boji retiniranom preko okvira naočara. Time je postignut zadovoljavajući estetski izgled, ali nije postignuta stabilnost pri kretnjama mandibule, s posledičnim curenjem pljuvačke preko komisure usana. Zaključak. Bolji funkcionalni i estetski ishod bi se mogli postići hirurško- protetičkom terapijom ovako velikog defekta lica.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Prosthetic therapy of the lateral facial defect
T1  - Protetička terapija lateralnog defekta lica
VL  - 59
IS  - 3
SP  - 164
EP  - 168
DO  - 10.2298/SGS1203164L
ER  - 
@article{
author = "Lazić, Vojkan and Đorđević, Igor",
year = "2012",
abstract = "Introduction. Facial defects may arise as a result of head and neck trauma or facial tumor ablation. Minor defects can be reconstructed surgically while large defects usually need combined surgical and prosthetic reconstruction. The aim of this study was to present the prosthetic reconstruction of the lateral facial defect using facial colored acrylic prosthesis. Case Report. A male patient with a maxillary defect on the left side and a large lateral facial defect on the same side received an obturator prosthesis as well as a facial colored acrylic prosthesis (facial-orbit) retained by the glasses frame. Satisfied aesthetics was accomplished. However, the stability of the prostheses during mandibular movements could not be achieved which resulted in saliva leakage over the lips. Conclusion. Better functional and aesthetic outcome could be achieved by combined surgical and prosthetic treatment of such large facial defect., Uvod. Defekti lica mogu nastati kao posledica povrede glave i vrata ili usled ablacije tumora predela lica ili okoline. Manji defekti se rekonstruišu hirurški, dok se velika oštećenja uglavnom rekonstruišu kombinovano, primenom hirurških i protetičkih metoda. Cilj rada je bio da se prikaže protetička rekonstrukcija lateralnog defekta lica facijalnom protezom od akrilata u boji. Prikaz bolesnika. Muškarcu s defektom levog dela maksile i velikim lateralnim defektom lica s iste strane izrađene su opturator- proteza i proteza lica (orbito-facijalna) od akrilata u boji retiniranom preko okvira naočara. Time je postignut zadovoljavajući estetski izgled, ali nije postignuta stabilnost pri kretnjama mandibule, s posledičnim curenjem pljuvačke preko komisure usana. Zaključak. Bolji funkcionalni i estetski ishod bi se mogli postići hirurško- protetičkom terapijom ovako velikog defekta lica.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Prosthetic therapy of the lateral facial defect, Protetička terapija lateralnog defekta lica",
volume = "59",
number = "3",
pages = "164-168",
doi = "10.2298/SGS1203164L"
}
Lazić, V.,& Đorđević, I.. (2012). Prosthetic therapy of the lateral facial defect. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 59(3), 164-168.
https://doi.org/10.2298/SGS1203164L
Lazić V, Đorđević I. Prosthetic therapy of the lateral facial defect. in Stomatološki glasnik Srbije. 2012;59(3):164-168.
doi:10.2298/SGS1203164L .
Lazić, Vojkan, Đorđević, Igor, "Prosthetic therapy of the lateral facial defect" in Stomatološki glasnik Srbije, 59, no. 3 (2012):164-168,
https://doi.org/10.2298/SGS1203164L . .

Comparative analysis of both stabilization appliance therapy and pharmacotherapy succses in temporomandibular disorder patients

Đorđević, Igor

(Univerzitet u Beogradu, Stomatološki fakultet, 2012)

TY  - THES
AU  - Đorđević, Igor
PY  - 2012
UR  - http://eteze.bg.ac.rs/application/showtheses?thesesId=574
UR  - https://fedorabg.bg.ac.rs/fedora/get/o:6731/bdef:Content/download
UR  - http://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=1024183950
UR  - http://nardus.mpn.gov.rs/123456789/2683
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/960
AB  - Pains that originate from the musculoskeletal structures of the masticatory system belong to sum of complaints that are included in a category of musculoskeletal disorders also known as tempororomandibular disorders (TMD). Pain is the most prominent TMD related symptom. Acute pain is associated with clinical condicions of intensive, rapid and severe pain onset combined with accompanying disturbances over a short time course. Chronic TMD related pain is defined as slowly developed and persistend symptom associated with psychologic, behavioral and psychosocial factors. There is significant relationship between chronic TMD related pain and depressive symptoms, similar to others musculoskeletal chronic pain patients. In a threatment of patients with TMD pain related symptoms there are several therapeutic modalites being used. Pharmacologic therapy can be effective adjunct in managing TMD pain related symptoms. Both occlusal apliance therapy and pharmacotherapy are customary in clinical practice and the most commonly used modalites in TMD pain reducing. The goal of this study is to assess the stabilization appliance therapy as a reliable procedure in reducing TMD related pain comparing with pharmacotherapy procedures. Using standarsided diagnostic protocol called Research Diagnostic Criteria for TMD (RDC/TMD) provided by Dworkin and LeResche a group of 44 patients with TMD related pain complains were singled out. After the chosen patients inlisted they were divided into three groups by random. The first group involved was subjected to stabilization appliance therapy in one month time duration. Two control groups were treated by Ibuprofen or Ibuprofen and Diazepam drug combination, respectively, in tree weeks time period. In order to evaluate effects both stabilization appliance and pharmacotherapy before and after proposed therapy we conducted measurements of intensity TMD related pain symptoms. For quantification of pain intensity prior to and after therapy both Visual Analogue Scale and digital pressure algometer were used. During the treatment serious side effect were not observed. In all three groups we achived notable pain reducing. There was no significally differenses in pain reducing sucsess between proposed modalites. Obtained results confirming the fact that occlisal stabilization appliance therapy to be valid therapeutic procedure in TMD pain reducing. Therefore, it should be recomended as useful and safe method in TMD pain therapy...
AB  - Bol koji potiče iz mišićno-skeletnih struktura mastikatornog sistema spada u grupu simptoma koji pripadaju kategoriji temporomandibularnih poremećaja ili temporomandibularnih disfunkcija (TMD). Bol u regiji lica, vilica i viličnih zglobova predstavlja najizraženiji i dominantan simptom temporomandibularnih disfunkcija i glavni razlog posete lekaru. Akutni bol je udružen sa kliničkom slikom intenzivnih, naglih i oštrih napada bolnih simptoma kombinovanih sa pratećim disfunkcijama, u kratkom vremenskom periodu. Bol hroničnog toka kod temporomandibularnih disfunkcija se definiše kao sporo napredujući i perzistentni simptom, udružen sa psihološkim faktorima, psihosocijalnim faktorima i faktorima bolnog ponašanja. Postoji značajna povezanost između hroničnog TMD bola i simptoma i znakova depresije, što je karakteristično i za hronične muskuloskeletne poremećaje izvan regije glave i vrata. Kontrola bola u pacijenata sa temporomandibularnim disfunkcijama obuhvata različite terapijske modalitete. Terapija lekovima predstavlja vid dopunske terapije u lečenju bolnih simptoma. Terapija stabilizacionim okluzalnim splintom i terapija lekovima su uobičajene procedure u svakodnevnoj kliničkoj praksi i najčešće se koriste u kontroli bola i redukciji simptoma i znakova temporomandibularnih disfunkcija. Cilj istraživanja je bio da se proceni efekat terapije stabilizacionim okluzalnim splintom kao procedure u kontroli bolnih simptoma TMD u poređenju sa efektom terapije lekovima. Koristeći standardni dijagnostički protokol (RDC/TMD) predložen od strane Dworkin-a i LeResche-a izdvojena je grupa od 44 pacijenta sa bolnim temporomandibularnim disfunkcijama. Pacijenti koji su uključeni u istraživanje su podeljeni u tri terapijske grupe slučajnim izborom. Prva grupa je podvrgnuta terapiji stabilizacionim okluzalnim splintom u vremenskom periodu od mesec dana. U dve kontrolne grupe je sprovedena terapija Ibuprofenom i kombinacijom Ibuprofena i Diazepama u periodu od tri nedelje. U cilju procene efekata terapije stabilizacionim okluzalnim splintom i terapije lekovima, pre i posle sprovedene terapije izvedena su merenja intenziteta bola. Kvantifikacija intenziteta bola izvršena je vizualnom analognom skalom (VAS) i digitalnim pritisnim algometrom. Tokom terapije nisu zabeleženi negativni sporedni efekti. U sve tri terapijske grupe postignuta je značajna redukcija intenziteta bolnih simptoma. Nisu zabeležene značajne razlike u uspešnosti redukcije bola između predloženih terapijskih modaliteta. Dobijeni rezultati potvrđuju da je terapija stabilizacionim okluzalnim splintom validna procedura u redukciji bola u pacijenata sa TMD. Zato se terapija stabilizacionim okluzalnim splintom može preporučiti kao pouzdan i bezbedan metod u kontroli bola orofacijalne regije muskuloskeletnog porekla...
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Comparative analysis of both stabilization appliance therapy and pharmacotherapy succses in temporomandibular disorder patients
T1  - Uporedna analiza uspešnosti stabilizacionog splinta i farmakoterapije u osoba sa temporomandibularnim disfunkcijama
UR  - https://hdl.handle.net/21.15107/rcub_nardus_2683
ER  - 
@phdthesis{
author = "Đorđević, Igor",
year = "2012",
abstract = "Pains that originate from the musculoskeletal structures of the masticatory system belong to sum of complaints that are included in a category of musculoskeletal disorders also known as tempororomandibular disorders (TMD). Pain is the most prominent TMD related symptom. Acute pain is associated with clinical condicions of intensive, rapid and severe pain onset combined with accompanying disturbances over a short time course. Chronic TMD related pain is defined as slowly developed and persistend symptom associated with psychologic, behavioral and psychosocial factors. There is significant relationship between chronic TMD related pain and depressive symptoms, similar to others musculoskeletal chronic pain patients. In a threatment of patients with TMD pain related symptoms there are several therapeutic modalites being used. Pharmacologic therapy can be effective adjunct in managing TMD pain related symptoms. Both occlusal apliance therapy and pharmacotherapy are customary in clinical practice and the most commonly used modalites in TMD pain reducing. The goal of this study is to assess the stabilization appliance therapy as a reliable procedure in reducing TMD related pain comparing with pharmacotherapy procedures. Using standarsided diagnostic protocol called Research Diagnostic Criteria for TMD (RDC/TMD) provided by Dworkin and LeResche a group of 44 patients with TMD related pain complains were singled out. After the chosen patients inlisted they were divided into three groups by random. The first group involved was subjected to stabilization appliance therapy in one month time duration. Two control groups were treated by Ibuprofen or Ibuprofen and Diazepam drug combination, respectively, in tree weeks time period. In order to evaluate effects both stabilization appliance and pharmacotherapy before and after proposed therapy we conducted measurements of intensity TMD related pain symptoms. For quantification of pain intensity prior to and after therapy both Visual Analogue Scale and digital pressure algometer were used. During the treatment serious side effect were not observed. In all three groups we achived notable pain reducing. There was no significally differenses in pain reducing sucsess between proposed modalites. Obtained results confirming the fact that occlisal stabilization appliance therapy to be valid therapeutic procedure in TMD pain reducing. Therefore, it should be recomended as useful and safe method in TMD pain therapy..., Bol koji potiče iz mišićno-skeletnih struktura mastikatornog sistema spada u grupu simptoma koji pripadaju kategoriji temporomandibularnih poremećaja ili temporomandibularnih disfunkcija (TMD). Bol u regiji lica, vilica i viličnih zglobova predstavlja najizraženiji i dominantan simptom temporomandibularnih disfunkcija i glavni razlog posete lekaru. Akutni bol je udružen sa kliničkom slikom intenzivnih, naglih i oštrih napada bolnih simptoma kombinovanih sa pratećim disfunkcijama, u kratkom vremenskom periodu. Bol hroničnog toka kod temporomandibularnih disfunkcija se definiše kao sporo napredujući i perzistentni simptom, udružen sa psihološkim faktorima, psihosocijalnim faktorima i faktorima bolnog ponašanja. Postoji značajna povezanost između hroničnog TMD bola i simptoma i znakova depresije, što je karakteristično i za hronične muskuloskeletne poremećaje izvan regije glave i vrata. Kontrola bola u pacijenata sa temporomandibularnim disfunkcijama obuhvata različite terapijske modalitete. Terapija lekovima predstavlja vid dopunske terapije u lečenju bolnih simptoma. Terapija stabilizacionim okluzalnim splintom i terapija lekovima su uobičajene procedure u svakodnevnoj kliničkoj praksi i najčešće se koriste u kontroli bola i redukciji simptoma i znakova temporomandibularnih disfunkcija. Cilj istraživanja je bio da se proceni efekat terapije stabilizacionim okluzalnim splintom kao procedure u kontroli bolnih simptoma TMD u poređenju sa efektom terapije lekovima. Koristeći standardni dijagnostički protokol (RDC/TMD) predložen od strane Dworkin-a i LeResche-a izdvojena je grupa od 44 pacijenta sa bolnim temporomandibularnim disfunkcijama. Pacijenti koji su uključeni u istraživanje su podeljeni u tri terapijske grupe slučajnim izborom. Prva grupa je podvrgnuta terapiji stabilizacionim okluzalnim splintom u vremenskom periodu od mesec dana. U dve kontrolne grupe je sprovedena terapija Ibuprofenom i kombinacijom Ibuprofena i Diazepama u periodu od tri nedelje. U cilju procene efekata terapije stabilizacionim okluzalnim splintom i terapije lekovima, pre i posle sprovedene terapije izvedena su merenja intenziteta bola. Kvantifikacija intenziteta bola izvršena je vizualnom analognom skalom (VAS) i digitalnim pritisnim algometrom. Tokom terapije nisu zabeleženi negativni sporedni efekti. U sve tri terapijske grupe postignuta je značajna redukcija intenziteta bolnih simptoma. Nisu zabeležene značajne razlike u uspešnosti redukcije bola između predloženih terapijskih modaliteta. Dobijeni rezultati potvrđuju da je terapija stabilizacionim okluzalnim splintom validna procedura u redukciji bola u pacijenata sa TMD. Zato se terapija stabilizacionim okluzalnim splintom može preporučiti kao pouzdan i bezbedan metod u kontroli bola orofacijalne regije muskuloskeletnog porekla...",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Comparative analysis of both stabilization appliance therapy and pharmacotherapy succses in temporomandibular disorder patients, Uporedna analiza uspešnosti stabilizacionog splinta i farmakoterapije u osoba sa temporomandibularnim disfunkcijama",
url = "https://hdl.handle.net/21.15107/rcub_nardus_2683"
}
Đorđević, I.. (2012). Comparative analysis of both stabilization appliance therapy and pharmacotherapy succses in temporomandibular disorder patients. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_nardus_2683
Đorđević I. Comparative analysis of both stabilization appliance therapy and pharmacotherapy succses in temporomandibular disorder patients. 2012;.
https://hdl.handle.net/21.15107/rcub_nardus_2683 .
Đorđević, Igor, "Comparative analysis of both stabilization appliance therapy and pharmacotherapy succses in temporomandibular disorder patients" (2012),
https://hdl.handle.net/21.15107/rcub_nardus_2683 .

Occlusal splints in reversible occlusal therapy of craniomandibular dysfunction

Lazić, Vojkan; Đorđević, Igor; Todorović, Ana

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2011)

TY  - JOUR
AU  - Lazić, Vojkan
AU  - Đorđević, Igor
AU  - Todorović, Ana
PY  - 2011
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1638
AB  - Craniomandibular dysfunction (CMD) is a set of structural and functional disorders of different etiology that affects temporomandibular joint (TMJ) and orofacial muscles. The most common etiologic factors are psychogenic, occlusal, trauma and congenital anomalies of craniofacial structures. About 75% of the examined population have mild symptoms of CMD while 3-4% have more severe symptoms which require medical attention. The main symptoms why people seek for medical attention are: facial pain which increases with chewing and irradiates in surrounding areas and pain in TMJ which irradiates in the ear canal, temporal area or neck. Painful restriction of mandible during mouth opening and eccentric movements is frequent as well as mandible deviation or deflection. Sound effects in TMJ such as popping or clicking during mouth opening are common. Initial and least invasive therapeutic procedure is reversible occlusal therapy using splints. There are two main types of occlusal splints: stabilization and relaxation. First type of splints works on condyle stabilization in orthopedically stable position; it is superoanterior condylar position in articular fossa with position of intercondylar discs between condyle and articular fossa when working cusps of the antagonists are in maximal contact with the splint. Another type of splint causes disocclussion of posterior teeth and eliminates negative effects of occlusal interference in the intercuspal position or during eccentric mandibular movements. During therapy, occlusal splint temporarily changes occlusal relationships as well as relations within TMJ, causing reduction of CMD symptoms. The best therapeutic effect for reduction of CMD symptoms is achieved by combination of physical therapy and medication.
AB  - Kraniomandibularne disfunkcije (KMD) jesu skup strukturnih i funkcijskih poremećaja različite etiologije koji zahvataju temporomandibularne zglobove (TMZ) i orofacijalnu muskulaturu. Najčešći etiološki faktori su psihogeni; slede okluzalni faktori, povrede i kongenitalne anomalije u predelu lica i vilica. Rasprostranjenost blagih simptoma KMD je oko 75%, dok 3-4% ispitanika ima teže simptome i potrebna im je lekarska pomoć. Glavne tegobe zbog kojih se osobe sa KMD javljaju lekaru jesu bol u predelu lica koji se pojačava pri žvakanju i širi se u okolne delove i bol u predelu TMZ koji se širi u ušni kanal, temporalno ili u vrat. Česta su i bolna ograničenja pokreta mandibule pri otvaranju usta i ekscentričnim kretnjama sa devijacijom ili defleksijom sredine donje vilice. Neretko se čuju i zvučni efekti preskakanja ili kliktanja u TMZ pri pokretanju donje vilice. Inicijalna i najmanje invazivna terapijska mera je reverzibilna okluzalna terapija splintovima. Okluzalni splintovi mogu biti stabilizacioni i relaksacioni. Prvi imaju zadatak da stabilizuju kondile u ortopedski stabilnom položaju - superoanteriorni položaj kondila u fosi artikularis sa pravilno interponiranim diskusima, kada se potporne kvržice antagonista nalaze u maksimalnom kontaktu sa pločom splinta. Drugi splintovi dovode do disokluzije bočnih zuba i eliminacije štetnog efekta okluzalnih interferenci u interkuspalnom položaju ili pri ekscentričnim kretnjama mandibule. Tokom terapije okluzalnim splintom privremeno se menjaju okluzalni i odnosi unutar TMZ do smanjenja simptoma KMD. Najbolji terapijski efekat suzbijanja simptoma KMD postiže se u kombinaciji s određenim vidovima fizikalne i medikamentne terapije.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - Occlusal splints in reversible occlusal therapy of craniomandibular dysfunction
T1  - Okluzalni splintovi u reverzibilnoj okluzalnoj terapiji kraniomandibularnih disfunkcija
VL  - 58
IS  - 3
SP  - 156
EP  - 162
DO  - 10.2298/SGS1103156L
ER  - 
@article{
author = "Lazić, Vojkan and Đorđević, Igor and Todorović, Ana",
year = "2011",
abstract = "Craniomandibular dysfunction (CMD) is a set of structural and functional disorders of different etiology that affects temporomandibular joint (TMJ) and orofacial muscles. The most common etiologic factors are psychogenic, occlusal, trauma and congenital anomalies of craniofacial structures. About 75% of the examined population have mild symptoms of CMD while 3-4% have more severe symptoms which require medical attention. The main symptoms why people seek for medical attention are: facial pain which increases with chewing and irradiates in surrounding areas and pain in TMJ which irradiates in the ear canal, temporal area or neck. Painful restriction of mandible during mouth opening and eccentric movements is frequent as well as mandible deviation or deflection. Sound effects in TMJ such as popping or clicking during mouth opening are common. Initial and least invasive therapeutic procedure is reversible occlusal therapy using splints. There are two main types of occlusal splints: stabilization and relaxation. First type of splints works on condyle stabilization in orthopedically stable position; it is superoanterior condylar position in articular fossa with position of intercondylar discs between condyle and articular fossa when working cusps of the antagonists are in maximal contact with the splint. Another type of splint causes disocclussion of posterior teeth and eliminates negative effects of occlusal interference in the intercuspal position or during eccentric mandibular movements. During therapy, occlusal splint temporarily changes occlusal relationships as well as relations within TMJ, causing reduction of CMD symptoms. The best therapeutic effect for reduction of CMD symptoms is achieved by combination of physical therapy and medication., Kraniomandibularne disfunkcije (KMD) jesu skup strukturnih i funkcijskih poremećaja različite etiologije koji zahvataju temporomandibularne zglobove (TMZ) i orofacijalnu muskulaturu. Najčešći etiološki faktori su psihogeni; slede okluzalni faktori, povrede i kongenitalne anomalije u predelu lica i vilica. Rasprostranjenost blagih simptoma KMD je oko 75%, dok 3-4% ispitanika ima teže simptome i potrebna im je lekarska pomoć. Glavne tegobe zbog kojih se osobe sa KMD javljaju lekaru jesu bol u predelu lica koji se pojačava pri žvakanju i širi se u okolne delove i bol u predelu TMZ koji se širi u ušni kanal, temporalno ili u vrat. Česta su i bolna ograničenja pokreta mandibule pri otvaranju usta i ekscentričnim kretnjama sa devijacijom ili defleksijom sredine donje vilice. Neretko se čuju i zvučni efekti preskakanja ili kliktanja u TMZ pri pokretanju donje vilice. Inicijalna i najmanje invazivna terapijska mera je reverzibilna okluzalna terapija splintovima. Okluzalni splintovi mogu biti stabilizacioni i relaksacioni. Prvi imaju zadatak da stabilizuju kondile u ortopedski stabilnom položaju - superoanteriorni položaj kondila u fosi artikularis sa pravilno interponiranim diskusima, kada se potporne kvržice antagonista nalaze u maksimalnom kontaktu sa pločom splinta. Drugi splintovi dovode do disokluzije bočnih zuba i eliminacije štetnog efekta okluzalnih interferenci u interkuspalnom položaju ili pri ekscentričnim kretnjama mandibule. Tokom terapije okluzalnim splintom privremeno se menjaju okluzalni i odnosi unutar TMZ do smanjenja simptoma KMD. Najbolji terapijski efekat suzbijanja simptoma KMD postiže se u kombinaciji s određenim vidovima fizikalne i medikamentne terapije.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "Occlusal splints in reversible occlusal therapy of craniomandibular dysfunction, Okluzalni splintovi u reverzibilnoj okluzalnoj terapiji kraniomandibularnih disfunkcija",
volume = "58",
number = "3",
pages = "156-162",
doi = "10.2298/SGS1103156L"
}
Lazić, V., Đorđević, I.,& Todorović, A.. (2011). Occlusal splints in reversible occlusal therapy of craniomandibular dysfunction. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 58(3), 156-162.
https://doi.org/10.2298/SGS1103156L
Lazić V, Đorđević I, Todorović A. Occlusal splints in reversible occlusal therapy of craniomandibular dysfunction. in Stomatološki glasnik Srbije. 2011;58(3):156-162.
doi:10.2298/SGS1103156L .
Lazić, Vojkan, Đorđević, Igor, Todorović, Ana, "Occlusal splints in reversible occlusal therapy of craniomandibular dysfunction" in Stomatološki glasnik Srbije, 58, no. 3 (2011):156-162,
https://doi.org/10.2298/SGS1103156L . .

The effect of repeated casting on the biocompatibility of a dental gold alloy

Stamenković, Dragoslav; Čairović, Aleksandra; Čolić, Miodrag; Rudolf, Rebeka; Radović, Katarina; Đorđević, Igor

(Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd, 2009)

TY  - JOUR
AU  - Stamenković, Dragoslav
AU  - Čairović, Aleksandra
AU  - Čolić, Miodrag
AU  - Rudolf, Rebeka
AU  - Radović, Katarina
AU  - Đorđević, Igor
PY  - 2009
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1478
AB  - Although highly noble Au alloys have been considered as biocompatible dental materials, little is known about whether recasting affects their biocompatibility. The aim of this work was to study the effect of repeated casting procedures on the microstructure and biocompatibilty of a noble Au dental alloy. The prepared samples of one- four- and eight times melted/cast Dentor S were used to study primary cutaneous irritation and sensibilization on experimental animals. The extract of the alloy prepared by conditioning the Dentor S samples in a cell culture medium was used to study the cytotoxicity on L929 cells. The elemental composition and surface changes of the alloy were examined by Energy Dispersive X-ray (EDX) analysis and optical microscopy, respectively. Our results showed that repeated casting decreased the biocompatibility of Dentor S, manifested as decreased metabolic and proliferative activities of L929 cells and that the effect correlated with the number of melting/casting procedures. However, neither sample of Dentor S caused irritation and sensibilization on experimental animals. EDX showed that recasting slightly increased the content of Au and Cu and slightly decreased the content of Pt, Pd and Zn. These changes correlated with the observations by optical microscopy. In conclusion, our results show that repeated casting of noble Au alloy changes its microstructure and decreases the biocompatibilty, suggesting that this procedure should be avoided in dental practice.
AB  - Visoko plemenite legure su biokompatibilni materijali, ali je malo poznato da li ponovljena livenja legura utiču na njihovu biokompatibilnost. Cilj ovog rada je bio da se utvrdi efekat ponovljenog topljenja i livenja na mikrostrukturu i biokompatibilnost visoko plemenitih dentalnih legura zlata. Pripremjena je serija uzoraka od jednom, četiri i osam puta topljene i livene Dentor S legure za ispitivanje primarne iritacije kože i senzibilizacije na eksperimentalnim životinjama, kao i in vitro ispitivanje citotoksičnosti na L929 ćelijama. Hemijski sastav i promena površine legure ispitivana je EDX analizom i optičkim mikroskopom. Naši rezultati su ukazali da ponavljana livenja smanjuju biokompatibilnost Dentor S legure, koja se manifestuje smanjenjem metabolitičke i proliferativne aktivnosti L929 ćelija i da je efekat u korelaciji s brojem topljenja i livenja. Ni jedan uzorak Dentor S legure ne uzrokuje iritaciju i senzibilizaciju eksperimentalnih životinja. EDX analiza dokazuje da ponovna livenja blago povećavaju procenat Au i Cu i blago smanjuju procenat Pt, Pd i Zn. Ove promene su u korelaciji sa zapažanjima na optičkom mikroskopu. Autori zaključuju da ponovljena livenja visoko plemenitih legura zlata menjaju mikrostrukturu i smanjuju biokompatibilnost i preporučuju da se ova procedura izbegava u svakodnevnoj praksi.
PB  - Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd
T2  - Acta veterinaria
T1  - The effect of repeated casting on the biocompatibility of a dental gold alloy
T1  - Uticaj ponavljanog livenja na biokompatibilnost dentalnih legura zlata
VL  - 59
IS  - 5-6
SP  - 641
EP  - 652
DO  - 10.2298/AVB0906641S
ER  - 
@article{
author = "Stamenković, Dragoslav and Čairović, Aleksandra and Čolić, Miodrag and Rudolf, Rebeka and Radović, Katarina and Đorđević, Igor",
year = "2009",
abstract = "Although highly noble Au alloys have been considered as biocompatible dental materials, little is known about whether recasting affects their biocompatibility. The aim of this work was to study the effect of repeated casting procedures on the microstructure and biocompatibilty of a noble Au dental alloy. The prepared samples of one- four- and eight times melted/cast Dentor S were used to study primary cutaneous irritation and sensibilization on experimental animals. The extract of the alloy prepared by conditioning the Dentor S samples in a cell culture medium was used to study the cytotoxicity on L929 cells. The elemental composition and surface changes of the alloy were examined by Energy Dispersive X-ray (EDX) analysis and optical microscopy, respectively. Our results showed that repeated casting decreased the biocompatibility of Dentor S, manifested as decreased metabolic and proliferative activities of L929 cells and that the effect correlated with the number of melting/casting procedures. However, neither sample of Dentor S caused irritation and sensibilization on experimental animals. EDX showed that recasting slightly increased the content of Au and Cu and slightly decreased the content of Pt, Pd and Zn. These changes correlated with the observations by optical microscopy. In conclusion, our results show that repeated casting of noble Au alloy changes its microstructure and decreases the biocompatibilty, suggesting that this procedure should be avoided in dental practice., Visoko plemenite legure su biokompatibilni materijali, ali je malo poznato da li ponovljena livenja legura utiču na njihovu biokompatibilnost. Cilj ovog rada je bio da se utvrdi efekat ponovljenog topljenja i livenja na mikrostrukturu i biokompatibilnost visoko plemenitih dentalnih legura zlata. Pripremjena je serija uzoraka od jednom, četiri i osam puta topljene i livene Dentor S legure za ispitivanje primarne iritacije kože i senzibilizacije na eksperimentalnim životinjama, kao i in vitro ispitivanje citotoksičnosti na L929 ćelijama. Hemijski sastav i promena površine legure ispitivana je EDX analizom i optičkim mikroskopom. Naši rezultati su ukazali da ponavljana livenja smanjuju biokompatibilnost Dentor S legure, koja se manifestuje smanjenjem metabolitičke i proliferativne aktivnosti L929 ćelija i da je efekat u korelaciji s brojem topljenja i livenja. Ni jedan uzorak Dentor S legure ne uzrokuje iritaciju i senzibilizaciju eksperimentalnih životinja. EDX analiza dokazuje da ponovna livenja blago povećavaju procenat Au i Cu i blago smanjuju procenat Pt, Pd i Zn. Ove promene su u korelaciji sa zapažanjima na optičkom mikroskopu. Autori zaključuju da ponovljena livenja visoko plemenitih legura zlata menjaju mikrostrukturu i smanjuju biokompatibilnost i preporučuju da se ova procedura izbegava u svakodnevnoj praksi.",
publisher = "Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd",
journal = "Acta veterinaria",
title = "The effect of repeated casting on the biocompatibility of a dental gold alloy, Uticaj ponavljanog livenja na biokompatibilnost dentalnih legura zlata",
volume = "59",
number = "5-6",
pages = "641-652",
doi = "10.2298/AVB0906641S"
}
Stamenković, D., Čairović, A., Čolić, M., Rudolf, R., Radović, K.,& Đorđević, I.. (2009). The effect of repeated casting on the biocompatibility of a dental gold alloy. in Acta veterinaria
Univerzitet u Beogradu - Fakultet veterinarske medicine, Beograd., 59(5-6), 641-652.
https://doi.org/10.2298/AVB0906641S
Stamenković D, Čairović A, Čolić M, Rudolf R, Radović K, Đorđević I. The effect of repeated casting on the biocompatibility of a dental gold alloy. in Acta veterinaria. 2009;59(5-6):641-652.
doi:10.2298/AVB0906641S .
Stamenković, Dragoslav, Čairović, Aleksandra, Čolić, Miodrag, Rudolf, Rebeka, Radović, Katarina, Đorđević, Igor, "The effect of repeated casting on the biocompatibility of a dental gold alloy" in Acta veterinaria, 59, no. 5-6 (2009):641-652,
https://doi.org/10.2298/AVB0906641S . .
3
2
4

Efekat transkutane električne nervne stimulacije na redukciju hroničnog mišićnog bola

Đorđević, Igor

(Univerzitet u Beogradu, Stomatološki fakultet, 2005)

TY  - THES
AU  - Đorđević, Igor
PY  - 2005
UR  - https://plus.sr.cobiss.net/opac7/bib/1024042638
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/420
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Efekat transkutane električne nervne stimulacije na redukciju hroničnog mišićnog bola
UR  - https://hdl.handle.net/21.15107/rcub_smile_420
ER  - 
@mastersthesis{
author = "Đorđević, Igor",
year = "2005",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Efekat transkutane električne nervne stimulacije na redukciju hroničnog mišićnog bola",
url = "https://hdl.handle.net/21.15107/rcub_smile_420"
}
Đorđević, I.. (2005). Efekat transkutane električne nervne stimulacije na redukciju hroničnog mišićnog bola. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_420
Đorđević I. Efekat transkutane električne nervne stimulacije na redukciju hroničnog mišićnog bola. 2005;.
https://hdl.handle.net/21.15107/rcub_smile_420 .
Đorđević, Igor, "Efekat transkutane električne nervne stimulacije na redukciju hroničnog mišićnog bola" (2005),
https://hdl.handle.net/21.15107/rcub_smile_420 .

The relationship between craniomandibular disorders and occlusal disharmonies in the adolescent population of the Republic of Serbia

Dodić, Slobodan; Sinobad, Vladimir; Đorđević, Igor

(Srpsko lekarsko društvo - Stomatološka sekcija, Beograd, 2004)

TY  - JOUR
AU  - Dodić, Slobodan
AU  - Sinobad, Vladimir
AU  - Đorđević, Igor
PY  - 2004
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1229
AB  - Using a special questionnaire adapted for computer evaluation, the prevalence of signs and symptoms of craniomandibular disorders (CMD) and occlusal disharmonies was investigated in a group of 500 adolescents of the Republic of Serbia ranging between 18 and 25 years of age. The presence of signs (symptoms) of CMD and occlusal discrepancies was established using clinical exsamination and evaluated according to the clinical disfunction index (D i) and index of the occlusal state (Oi) proposed by Helkimo et al. 1974. The results of this study revealed that 327 (65.4%) adolescents in the examined group had at least one sign (symptom) of CMD, (Di > 1), and that 271 (54.2%) adolescent had also mild, or severe occlusal discrepancies (Oi > 1). The percentage of persons with signs(symptoms) of CMD was significantly greater in the group having occlusal discrepancies (X = 7.76, P lt 0.01). The multiple regression analysis of the obtained data and the ODDS ratio confirmed the risk of CMD in the group with occlusal discrepancies to be 2.5 times greater than in the group of adolescents without occlusal discrepancies.
AB  - Cilj istraživanja je bio da se utvrdi rasprostranjenost znakova (simptoma) kraniomandibularnih disfunkcija (CMD) i odredjenih oblika okluzalnih disharmonija u populaciji od 500 ispitanika starosti 18-25 godina iz raznih regiona Republike Srbije. Prisustvo znakova (simptoma) CMD-a kao i okluzalnih disharmonija utvrdjivano je kliničkim pregledom i vrednovano pomoću indeksa difunkcije (Di) i okluzalnog indeksa (Oi) po Helkimu. Utvrdjeno je da 327 ispitanika (65.4%) ima barem neki znak CMD-a, a da 271 (54.2%) ispitanika ima prisutne okluzalne disharmonije (nepodudarnost sredine zubnih nizova u IKP, odsustvo kontakata sa antagonistima u IKP, prisustvo okluzalnih smetnji, gubitak zuba). Koristeći metod multipne regresione analize i ODDS - odnos utvrdjeno je da je rizik od kraniomandibularnih disfunkcija kod ispitanika sa prisustvom okluzalnih disharmonija 2.5 puta veći u odnosu na ispitanike bez takvih disharmonija.
PB  - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
T2  - Stomatološki glasnik Srbije
T1  - The relationship between craniomandibular disorders and occlusal disharmonies in the adolescent population of the Republic of Serbia
T1  - Odnos između kraniomandibularnih disfunkcija i okluzalnih disharmonija u polpulaciji adolescenata Republike Srbije
VL  - 51
IS  - 2
SP  - 83
EP  - 88
DO  - 10.2298/SGS0402083D
ER  - 
@article{
author = "Dodić, Slobodan and Sinobad, Vladimir and Đorđević, Igor",
year = "2004",
abstract = "Using a special questionnaire adapted for computer evaluation, the prevalence of signs and symptoms of craniomandibular disorders (CMD) and occlusal disharmonies was investigated in a group of 500 adolescents of the Republic of Serbia ranging between 18 and 25 years of age. The presence of signs (symptoms) of CMD and occlusal discrepancies was established using clinical exsamination and evaluated according to the clinical disfunction index (D i) and index of the occlusal state (Oi) proposed by Helkimo et al. 1974. The results of this study revealed that 327 (65.4%) adolescents in the examined group had at least one sign (symptom) of CMD, (Di > 1), and that 271 (54.2%) adolescent had also mild, or severe occlusal discrepancies (Oi > 1). The percentage of persons with signs(symptoms) of CMD was significantly greater in the group having occlusal discrepancies (X = 7.76, P lt 0.01). The multiple regression analysis of the obtained data and the ODDS ratio confirmed the risk of CMD in the group with occlusal discrepancies to be 2.5 times greater than in the group of adolescents without occlusal discrepancies., Cilj istraživanja je bio da se utvrdi rasprostranjenost znakova (simptoma) kraniomandibularnih disfunkcija (CMD) i odredjenih oblika okluzalnih disharmonija u populaciji od 500 ispitanika starosti 18-25 godina iz raznih regiona Republike Srbije. Prisustvo znakova (simptoma) CMD-a kao i okluzalnih disharmonija utvrdjivano je kliničkim pregledom i vrednovano pomoću indeksa difunkcije (Di) i okluzalnog indeksa (Oi) po Helkimu. Utvrdjeno je da 327 ispitanika (65.4%) ima barem neki znak CMD-a, a da 271 (54.2%) ispitanika ima prisutne okluzalne disharmonije (nepodudarnost sredine zubnih nizova u IKP, odsustvo kontakata sa antagonistima u IKP, prisustvo okluzalnih smetnji, gubitak zuba). Koristeći metod multipne regresione analize i ODDS - odnos utvrdjeno je da je rizik od kraniomandibularnih disfunkcija kod ispitanika sa prisustvom okluzalnih disharmonija 2.5 puta veći u odnosu na ispitanike bez takvih disharmonija.",
publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd",
journal = "Stomatološki glasnik Srbije",
title = "The relationship between craniomandibular disorders and occlusal disharmonies in the adolescent population of the Republic of Serbia, Odnos između kraniomandibularnih disfunkcija i okluzalnih disharmonija u polpulaciji adolescenata Republike Srbije",
volume = "51",
number = "2",
pages = "83-88",
doi = "10.2298/SGS0402083D"
}
Dodić, S., Sinobad, V.,& Đorđević, I.. (2004). The relationship between craniomandibular disorders and occlusal disharmonies in the adolescent population of the Republic of Serbia. in Stomatološki glasnik Srbije
Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 51(2), 83-88.
https://doi.org/10.2298/SGS0402083D
Dodić S, Sinobad V, Đorđević I. The relationship between craniomandibular disorders and occlusal disharmonies in the adolescent population of the Republic of Serbia. in Stomatološki glasnik Srbije. 2004;51(2):83-88.
doi:10.2298/SGS0402083D .
Dodić, Slobodan, Sinobad, Vladimir, Đorđević, Igor, "The relationship between craniomandibular disorders and occlusal disharmonies in the adolescent population of the Republic of Serbia" in Stomatološki glasnik Srbije, 51, no. 2 (2004):83-88,
https://doi.org/10.2298/SGS0402083D . .
1