Van Meerbeek, Bart

Link to this page

Authority KeyName Variants
0e8bd937-46c5-49db-b17a-408604bf26f4
  • Van Meerbeek, Bart (5)
Projects

Author's Bibliography

Curing characteristics of flowable and sculptable bulk-fill composites

Miletić, Vesna; Pongprueksa, Pong; de Munck, Jan; Brooks, Neil R.; Van Meerbeek, Bart

(Springer Heidelberg, Heidelberg, 2017)

TY  - JOUR
AU  - Miletić, Vesna
AU  - Pongprueksa, Pong
AU  - de Munck, Jan
AU  - Brooks, Neil R.
AU  - Van Meerbeek, Bart
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2191
AB  - The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (alpha = 0.05). DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.
PB  - Springer Heidelberg, Heidelberg
T2  - Clinical Oral Investigations
T1  - Curing characteristics of flowable and sculptable bulk-fill composites
VL  - 21
IS  - 4
SP  - 1201
EP  - 1212
DO  - 10.1007/s00784-016-1894-0
ER  - 
@article{
author = "Miletić, Vesna and Pongprueksa, Pong and de Munck, Jan and Brooks, Neil R. and Van Meerbeek, Bart",
year = "2017",
abstract = "The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (alpha = 0.05). DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.",
publisher = "Springer Heidelberg, Heidelberg",
journal = "Clinical Oral Investigations",
title = "Curing characteristics of flowable and sculptable bulk-fill composites",
volume = "21",
number = "4",
pages = "1201-1212",
doi = "10.1007/s00784-016-1894-0"
}
Miletić, V., Pongprueksa, P., de Munck, J., Brooks, N. R.,& Van Meerbeek, B.. (2017). Curing characteristics of flowable and sculptable bulk-fill composites. in Clinical Oral Investigations
Springer Heidelberg, Heidelberg., 21(4), 1201-1212.
https://doi.org/10.1007/s00784-016-1894-0
Miletić V, Pongprueksa P, de Munck J, Brooks NR, Van Meerbeek B. Curing characteristics of flowable and sculptable bulk-fill composites. in Clinical Oral Investigations. 2017;21(4):1201-1212.
doi:10.1007/s00784-016-1894-0 .
Miletić, Vesna, Pongprueksa, Pong, de Munck, Jan, Brooks, Neil R., Van Meerbeek, Bart, "Curing characteristics of flowable and sculptable bulk-fill composites" in Clinical Oral Investigations, 21, no. 4 (2017):1201-1212,
https://doi.org/10.1007/s00784-016-1894-0 . .
75
33
63

Effect of resin and photoinitiator on color, translucency and color stability of conventional and low-shrinkage model composites

Manojlović, Dragica; Dramićanin, Miroslav D.; Ležaja, Maja; Pongprueksa, Pong; Van Meerbeek, Bart; Miletić, Vesna

(Elsevier Sci Ltd, Oxford, 2016)

TY  - JOUR
AU  - Manojlović, Dragica
AU  - Dramićanin, Miroslav D.
AU  - Ležaja, Maja
AU  - Pongprueksa, Pong
AU  - Van Meerbeek, Bart
AU  - Miletić, Vesna
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2145
AB  - Objective. To study the effect of a low-shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on color, translucency, and color stability of model resin-based composites (RBCs). Methods. Four micro-hybrid RBCs were prepared containing barium-glass fillers in bisphenol A-glycidyl-methacrylate (BisGMA) and triethyleneglycol-dimethacrylate (TEGDMA) or urethane-based low-shrinkage monomer FIT-852 (FIT; Esstech Inc.) and TEGDMA matrix. Camphorquinone (CQ)/amine or Lucirin TPO were used as photoinitiators. Commercial low-shrinkage RBCs (Charisma Diamond, Heraeus Kulzer and N'Durance, Septodont) and conventional RBCs (Tetric EvoCeram, Ivoclar Vivadent and Filtek Z250, 3M ESPE) were used as controls. Color and translucency were measured using Thermo Scientific Evolution (Thermo Fisher Scientific) and SpectroShade (TM) Micro (MHT Optic Research) spectrophotometers. Color stability was evaluated after immersion in black tea (pure, with milk or lemon) and distilled water. Data were analyzed using analyses of variance with Tukey's post-test (alpha = 0.05). Results. Photoinitiators had no significant effect on baseline color. Initially whiter FIT-based RBCs showed greater staining in all staining solutions than BisGMA-based RBCs. TPO-containing RBCs showed better color stability than CQ-containing RBCs irrespective of the base monomer. Tea and tea with lemon induced greatest color changes. Adding milk to tea significantly reduced material staining. Significance. Urethane-based low-shrinkage monomer FIT and conventional BisGMA affected color, translucency and color stability of their respective RBCs. Despite being used in posterior teeth, low-shrinkage RBCs are expected to have favorable optical and esthetic properties. Manufacturers are urged to provide information on optical properties of monomers and monomer mixtures in their low-shrinkage RBCs to allow understanding of interaction with fillers and photoinitiators.
PB  - Elsevier Sci Ltd, Oxford
T2  - Dental Materials
T1  - Effect of resin and photoinitiator on color, translucency and color stability of conventional and low-shrinkage model composites
VL  - 32
IS  - 2
SP  - 183
EP  - 191
DO  - 10.1016/j.dental.2015.11.027
ER  - 
@article{
author = "Manojlović, Dragica and Dramićanin, Miroslav D. and Ležaja, Maja and Pongprueksa, Pong and Van Meerbeek, Bart and Miletić, Vesna",
year = "2016",
abstract = "Objective. To study the effect of a low-shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on color, translucency, and color stability of model resin-based composites (RBCs). Methods. Four micro-hybrid RBCs were prepared containing barium-glass fillers in bisphenol A-glycidyl-methacrylate (BisGMA) and triethyleneglycol-dimethacrylate (TEGDMA) or urethane-based low-shrinkage monomer FIT-852 (FIT; Esstech Inc.) and TEGDMA matrix. Camphorquinone (CQ)/amine or Lucirin TPO were used as photoinitiators. Commercial low-shrinkage RBCs (Charisma Diamond, Heraeus Kulzer and N'Durance, Septodont) and conventional RBCs (Tetric EvoCeram, Ivoclar Vivadent and Filtek Z250, 3M ESPE) were used as controls. Color and translucency were measured using Thermo Scientific Evolution (Thermo Fisher Scientific) and SpectroShade (TM) Micro (MHT Optic Research) spectrophotometers. Color stability was evaluated after immersion in black tea (pure, with milk or lemon) and distilled water. Data were analyzed using analyses of variance with Tukey's post-test (alpha = 0.05). Results. Photoinitiators had no significant effect on baseline color. Initially whiter FIT-based RBCs showed greater staining in all staining solutions than BisGMA-based RBCs. TPO-containing RBCs showed better color stability than CQ-containing RBCs irrespective of the base monomer. Tea and tea with lemon induced greatest color changes. Adding milk to tea significantly reduced material staining. Significance. Urethane-based low-shrinkage monomer FIT and conventional BisGMA affected color, translucency and color stability of their respective RBCs. Despite being used in posterior teeth, low-shrinkage RBCs are expected to have favorable optical and esthetic properties. Manufacturers are urged to provide information on optical properties of monomers and monomer mixtures in their low-shrinkage RBCs to allow understanding of interaction with fillers and photoinitiators.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Dental Materials",
title = "Effect of resin and photoinitiator on color, translucency and color stability of conventional and low-shrinkage model composites",
volume = "32",
number = "2",
pages = "183-191",
doi = "10.1016/j.dental.2015.11.027"
}
Manojlović, D., Dramićanin, M. D., Ležaja, M., Pongprueksa, P., Van Meerbeek, B.,& Miletić, V.. (2016). Effect of resin and photoinitiator on color, translucency and color stability of conventional and low-shrinkage model composites. in Dental Materials
Elsevier Sci Ltd, Oxford., 32(2), 183-191.
https://doi.org/10.1016/j.dental.2015.11.027
Manojlović D, Dramićanin MD, Ležaja M, Pongprueksa P, Van Meerbeek B, Miletić V. Effect of resin and photoinitiator on color, translucency and color stability of conventional and low-shrinkage model composites. in Dental Materials. 2016;32(2):183-191.
doi:10.1016/j.dental.2015.11.027 .
Manojlović, Dragica, Dramićanin, Miroslav D., Ležaja, Maja, Pongprueksa, Pong, Van Meerbeek, Bart, Miletić, Vesna, "Effect of resin and photoinitiator on color, translucency and color stability of conventional and low-shrinkage model composites" in Dental Materials, 32, no. 2 (2016):183-191,
https://doi.org/10.1016/j.dental.2015.11.027 . .
41
24
36

Effect of Evaporation on the Shelf Life of a Universal Adhesive

Pongprueksa, Pong; Miletić, Vesna; de Munck, Jan; Brooks, Neil R.; Meersman, F.; Nies, E.; Van Meerbeek, Bart; Van Landuyt, Kirsten L.

(Operative Dentistry Inc, Indianapolis, 2014)

TY  - JOUR
AU  - Pongprueksa, Pong
AU  - Miletić, Vesna
AU  - de Munck, Jan
AU  - Brooks, Neil R.
AU  - Meersman, F.
AU  - Nies, E.
AU  - Van Meerbeek, Bart
AU  - Van Landuyt, Kirsten L.
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1879
AB  - Objectives: The purpose of this study was to evaluate how evaporation affects the shelf life of a one-bottle universal adhesive. Methods: Three different versions of Scotchbond Universal (SBU, 3M ESPE, Seefeld, Germany) were prepared using a weight-loss technique. SBU0 was left open to the air until maximal weight loss was obtained, whereas SBU50 was left open until 50% of evaporation occurred. In contrast, SBU100 was kept closed and was assumed to contain the maximum concentration of all ingredients. The degree of conversion (DC) was determined by using Fourier transform infrared spectroscopy on different substrates (on dentin or glass plate and mixed with dentin powder); ultimate microtensile strength and microtensile bond strength to dentin were measured as well. Results: DC of the 100% solvent-containing adhesive (SBU100) was higher than that of the 50% (SBU50) and 0% (SBU0) solvent-containing adhesives for all substrates. DC of the adhesive applied onto glass and dehydrated dentin was higher than that applied onto dentin. Even though the ultimate microtensile strength of SBU0 was much higher than that of SBU50 and SBU100, its bond strength to dentin was significantly lower. Conclusions: Evaporation of adhesive ingredients may jeopardize the shelf life of a one-bottle universal system by reducing the degree of conversion and impairing bond strength. However, negative effects only became evident after more than 50% evaporation.
PB  - Operative Dentistry Inc, Indianapolis
T2  - Operative Dentistry
T1  - Effect of Evaporation on the Shelf Life of a Universal Adhesive
VL  - 39
IS  - 5
SP  - 500
EP  - 507
DO  - 10.2341/13-195
ER  - 
@article{
author = "Pongprueksa, Pong and Miletić, Vesna and de Munck, Jan and Brooks, Neil R. and Meersman, F. and Nies, E. and Van Meerbeek, Bart and Van Landuyt, Kirsten L.",
year = "2014",
abstract = "Objectives: The purpose of this study was to evaluate how evaporation affects the shelf life of a one-bottle universal adhesive. Methods: Three different versions of Scotchbond Universal (SBU, 3M ESPE, Seefeld, Germany) were prepared using a weight-loss technique. SBU0 was left open to the air until maximal weight loss was obtained, whereas SBU50 was left open until 50% of evaporation occurred. In contrast, SBU100 was kept closed and was assumed to contain the maximum concentration of all ingredients. The degree of conversion (DC) was determined by using Fourier transform infrared spectroscopy on different substrates (on dentin or glass plate and mixed with dentin powder); ultimate microtensile strength and microtensile bond strength to dentin were measured as well. Results: DC of the 100% solvent-containing adhesive (SBU100) was higher than that of the 50% (SBU50) and 0% (SBU0) solvent-containing adhesives for all substrates. DC of the adhesive applied onto glass and dehydrated dentin was higher than that applied onto dentin. Even though the ultimate microtensile strength of SBU0 was much higher than that of SBU50 and SBU100, its bond strength to dentin was significantly lower. Conclusions: Evaporation of adhesive ingredients may jeopardize the shelf life of a one-bottle universal system by reducing the degree of conversion and impairing bond strength. However, negative effects only became evident after more than 50% evaporation.",
publisher = "Operative Dentistry Inc, Indianapolis",
journal = "Operative Dentistry",
title = "Effect of Evaporation on the Shelf Life of a Universal Adhesive",
volume = "39",
number = "5",
pages = "500-507",
doi = "10.2341/13-195"
}
Pongprueksa, P., Miletić, V., de Munck, J., Brooks, N. R., Meersman, F., Nies, E., Van Meerbeek, B.,& Van Landuyt, K. L.. (2014). Effect of Evaporation on the Shelf Life of a Universal Adhesive. in Operative Dentistry
Operative Dentistry Inc, Indianapolis., 39(5), 500-507.
https://doi.org/10.2341/13-195
Pongprueksa P, Miletić V, de Munck J, Brooks NR, Meersman F, Nies E, Van Meerbeek B, Van Landuyt KL. Effect of Evaporation on the Shelf Life of a Universal Adhesive. in Operative Dentistry. 2014;39(5):500-507.
doi:10.2341/13-195 .
Pongprueksa, Pong, Miletić, Vesna, de Munck, Jan, Brooks, Neil R., Meersman, F., Nies, E., Van Meerbeek, Bart, Van Landuyt, Kirsten L., "Effect of Evaporation on the Shelf Life of a Universal Adhesive" in Operative Dentistry, 39, no. 5 (2014):500-507,
https://doi.org/10.2341/13-195 . .
1
11
11
13

Degree of conversion and monomer elution of CQ/amine and TPO adhesives

Pongprueksa, Pong; Miletić, Vesna; Janssens, Henriette; Van Landuyt, Kirsten L.; de Munck, Jan; Godderis, Lode; Van Meerbeek, Bart

(Elsevier Sci Ltd, Oxford, 2014)

TY  - JOUR
AU  - Pongprueksa, Pong
AU  - Miletić, Vesna
AU  - Janssens, Henriette
AU  - Van Landuyt, Kirsten L.
AU  - de Munck, Jan
AU  - Godderis, Lode
AU  - Van Meerbeek, Bart
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1861
AB  - Objective. To evaluate the effect of photo-initiator on the degree of conversion (DC) and elution of Bis-GMA and HEMA for 8 one-step adhesive formulations. Methods. We used Scotchbond Universal ('SBU-CQ/amine 4.0', 3M ESPE), containing about 2 wt% camphorquinone (CQ) and 2 wt% ethyl-4-dimethylamino benzoate( EDMAB), an experimental 'SBU-TPO 2.1' version, containing 2.1 wt% diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO), and 6 experimental LUB adhesives (Kuraray Noritake), namely 'LUB-CQ/amine 0.7', 'LUB-CQ/amine 1.4', 'LUB-CQ/amine 4.0', 'LUBTPO 0.35', 'LUB-TPO 0.7' and 'LUB-TPO 2.0', respectively containing 0.35 wt% CQ and 0.35 wt% EDMAB, 0.7 wt% CQ and 0.7 wt% EDMAB, 2.0 wt% CQ and 2.0 wt% EDMAB, 0.35 wt% TPO, 0.7 wt% TPO, and 2.0 wt% TPO. DC was measured using micro-Raman spectroscopy. Additional specimens were immersed in ethanol for 24 h to determine the elution of Bis-GMA and HEMA using HPLC. Results. DC of the respective SBU and LUB adhesives was alike at high photo-initiator concentration. At low concentration, TPO was significantly more efficient than CQ/amine (LUB adhesives only). A statistically significant positive photo-initiator concentration effect on DC was noted for both CQ/amine and TPO (LUB adhesives only). A statistically significant inversephoto-initiator concentration effect on HEMA elution was noted for both the CQ/amine and TPO-containing LUB adhesives. A significantly strong correlation was found between DC and Bis-GMA elution (R-2 = 0.744, p = 0.026), and between DC and HEMA elution (R-2 = 0.913, p = 0.002) for the LUB adhesives. Significance. The photo-initiator kind and concentration affect DC and the Bis-GMA/HEMAelution. TPO can be used as an alternative photo-initiator for CQ/amine.
PB  - Elsevier Sci Ltd, Oxford
T2  - Dental Materials
T1  - Degree of conversion and monomer elution of CQ/amine and TPO adhesives
VL  - 30
IS  - 6
SP  - 695
EP  - 701
DO  - 10.1016/j.dental.2014.03.007
ER  - 
@article{
author = "Pongprueksa, Pong and Miletić, Vesna and Janssens, Henriette and Van Landuyt, Kirsten L. and de Munck, Jan and Godderis, Lode and Van Meerbeek, Bart",
year = "2014",
abstract = "Objective. To evaluate the effect of photo-initiator on the degree of conversion (DC) and elution of Bis-GMA and HEMA for 8 one-step adhesive formulations. Methods. We used Scotchbond Universal ('SBU-CQ/amine 4.0', 3M ESPE), containing about 2 wt% camphorquinone (CQ) and 2 wt% ethyl-4-dimethylamino benzoate( EDMAB), an experimental 'SBU-TPO 2.1' version, containing 2.1 wt% diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO), and 6 experimental LUB adhesives (Kuraray Noritake), namely 'LUB-CQ/amine 0.7', 'LUB-CQ/amine 1.4', 'LUB-CQ/amine 4.0', 'LUBTPO 0.35', 'LUB-TPO 0.7' and 'LUB-TPO 2.0', respectively containing 0.35 wt% CQ and 0.35 wt% EDMAB, 0.7 wt% CQ and 0.7 wt% EDMAB, 2.0 wt% CQ and 2.0 wt% EDMAB, 0.35 wt% TPO, 0.7 wt% TPO, and 2.0 wt% TPO. DC was measured using micro-Raman spectroscopy. Additional specimens were immersed in ethanol for 24 h to determine the elution of Bis-GMA and HEMA using HPLC. Results. DC of the respective SBU and LUB adhesives was alike at high photo-initiator concentration. At low concentration, TPO was significantly more efficient than CQ/amine (LUB adhesives only). A statistically significant positive photo-initiator concentration effect on DC was noted for both CQ/amine and TPO (LUB adhesives only). A statistically significant inversephoto-initiator concentration effect on HEMA elution was noted for both the CQ/amine and TPO-containing LUB adhesives. A significantly strong correlation was found between DC and Bis-GMA elution (R-2 = 0.744, p = 0.026), and between DC and HEMA elution (R-2 = 0.913, p = 0.002) for the LUB adhesives. Significance. The photo-initiator kind and concentration affect DC and the Bis-GMA/HEMAelution. TPO can be used as an alternative photo-initiator for CQ/amine.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Dental Materials",
title = "Degree of conversion and monomer elution of CQ/amine and TPO adhesives",
volume = "30",
number = "6",
pages = "695-701",
doi = "10.1016/j.dental.2014.03.007"
}
Pongprueksa, P., Miletić, V., Janssens, H., Van Landuyt, K. L., de Munck, J., Godderis, L.,& Van Meerbeek, B.. (2014). Degree of conversion and monomer elution of CQ/amine and TPO adhesives. in Dental Materials
Elsevier Sci Ltd, Oxford., 30(6), 695-701.
https://doi.org/10.1016/j.dental.2014.03.007
Pongprueksa P, Miletić V, Janssens H, Van Landuyt KL, de Munck J, Godderis L, Van Meerbeek B. Degree of conversion and monomer elution of CQ/amine and TPO adhesives. in Dental Materials. 2014;30(6):695-701.
doi:10.1016/j.dental.2014.03.007 .
Pongprueksa, Pong, Miletić, Vesna, Janssens, Henriette, Van Landuyt, Kirsten L., de Munck, Jan, Godderis, Lode, Van Meerbeek, Bart, "Degree of conversion and monomer elution of CQ/amine and TPO adhesives" in Dental Materials, 30, no. 6 (2014):695-701,
https://doi.org/10.1016/j.dental.2014.03.007 . .
37
29
37

Monomer-to-polymer conversion and micro-tensile bond strength to dentine of experimental and commercial adhesives containing diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide or a camphorquinone/amine photo-initiator system

Miletić, Vesna; Pongprueksa, Pong; de Munck, Jan; Brooks, Neil R.; Van Meerbeek, Bart

(Elsevier Sci Ltd, Oxford, 2013)

TY  - JOUR
AU  - Miletić, Vesna
AU  - Pongprueksa, Pong
AU  - de Munck, Jan
AU  - Brooks, Neil R.
AU  - Van Meerbeek, Bart
PY  - 2013
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1847
AB  - Objectives: To compare the degree of conversion (DC) of adhesives initiated by diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO) or a camphorquinone/tertiary amine system (CQ/Amine) as well as their 'immediate' micro-tensile bond strength (mu TBS) to bur-cut dentine. Methods: DC of Scotch bond Universal('SBU';3MESPE), its experimental counter part containing TPO as photo-initiator system, an experimental G-aenial Bond ('Ga-B'; GC) adhesive formulation, and an experimental LUB-102 adhesive formulation ('LUB', Kuraray Noritake), containing as photo-initiatior system either 2 wt% CQ along with 2 wt% tertiary amine ('SBU_CQ/Amine'; 'Ga-B_CQ/Amine'; 'LUB_CQ/Amine'), or 2 wt% TPO ('SBU_TPO'; 'Ga-B_TPO'; 'LUB_TPO'), was determined using Fourier-transform infrared spectroscopy(FTIR), after being cured with a dual wave length light-curing unit(blue phase 20i, Ivoclar Vivadent). The same adhesive formulations were applied to bur-cut mid-coronal dentine of intact human molars, and subjected to a mTBS test after 1-week water storage. Besides being applied following a self-etch (SE) application mode, the adhesive formulations SBU_CQ/Amine and SBU_TPO were also applied following an etch-and-rinse (E&R) mode, this both for DS and mTBS measurement. Results: No significant difference in DC was found for any of the adhesive formulations, except for SBU_CQ/Amine_SE and SBU_TPO_SE. For both SBU formulations, a significantly higher DC was reached for the E&R than the SE approach. Regarding mTBS, no significant differences were recorded, except for the significantly higher mTBS measured for SBU_CQ/Amine_E&R and SBU_TPO_E&R. Conclusions: In self-etch adhesives, the photo-initiator TPO may be used instead of CQ/Amine. The curing and 'immediate' bonding efficiency depended on the application protocol (E&R versus SE), but not on the photo-initiator system. Clinical significance: The photo-initiator TPO may be used in self-etch adhesives instead of CQ/Amine with similar curing and 'immediate' bonding efficiency.
PB  - Elsevier Sci Ltd, Oxford
T2  - Journal of Dentistry
T1  - Monomer-to-polymer conversion and micro-tensile bond strength to dentine of experimental and commercial adhesives containing diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide or a camphorquinone/amine photo-initiator system
VL  - 41
IS  - 10
SP  - 918
EP  - 926
DO  - 10.1016/j.jdent.2013.07.007
ER  - 
@article{
author = "Miletić, Vesna and Pongprueksa, Pong and de Munck, Jan and Brooks, Neil R. and Van Meerbeek, Bart",
year = "2013",
abstract = "Objectives: To compare the degree of conversion (DC) of adhesives initiated by diphenyl(2,4,6-trimethylbenzoyl) phosphine oxide (TPO) or a camphorquinone/tertiary amine system (CQ/Amine) as well as their 'immediate' micro-tensile bond strength (mu TBS) to bur-cut dentine. Methods: DC of Scotch bond Universal('SBU';3MESPE), its experimental counter part containing TPO as photo-initiator system, an experimental G-aenial Bond ('Ga-B'; GC) adhesive formulation, and an experimental LUB-102 adhesive formulation ('LUB', Kuraray Noritake), containing as photo-initiatior system either 2 wt% CQ along with 2 wt% tertiary amine ('SBU_CQ/Amine'; 'Ga-B_CQ/Amine'; 'LUB_CQ/Amine'), or 2 wt% TPO ('SBU_TPO'; 'Ga-B_TPO'; 'LUB_TPO'), was determined using Fourier-transform infrared spectroscopy(FTIR), after being cured with a dual wave length light-curing unit(blue phase 20i, Ivoclar Vivadent). The same adhesive formulations were applied to bur-cut mid-coronal dentine of intact human molars, and subjected to a mTBS test after 1-week water storage. Besides being applied following a self-etch (SE) application mode, the adhesive formulations SBU_CQ/Amine and SBU_TPO were also applied following an etch-and-rinse (E&R) mode, this both for DS and mTBS measurement. Results: No significant difference in DC was found for any of the adhesive formulations, except for SBU_CQ/Amine_SE and SBU_TPO_SE. For both SBU formulations, a significantly higher DC was reached for the E&R than the SE approach. Regarding mTBS, no significant differences were recorded, except for the significantly higher mTBS measured for SBU_CQ/Amine_E&R and SBU_TPO_E&R. Conclusions: In self-etch adhesives, the photo-initiator TPO may be used instead of CQ/Amine. The curing and 'immediate' bonding efficiency depended on the application protocol (E&R versus SE), but not on the photo-initiator system. Clinical significance: The photo-initiator TPO may be used in self-etch adhesives instead of CQ/Amine with similar curing and 'immediate' bonding efficiency.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Journal of Dentistry",
title = "Monomer-to-polymer conversion and micro-tensile bond strength to dentine of experimental and commercial adhesives containing diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide or a camphorquinone/amine photo-initiator system",
volume = "41",
number = "10",
pages = "918-926",
doi = "10.1016/j.jdent.2013.07.007"
}
Miletić, V., Pongprueksa, P., de Munck, J., Brooks, N. R.,& Van Meerbeek, B.. (2013). Monomer-to-polymer conversion and micro-tensile bond strength to dentine of experimental and commercial adhesives containing diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide or a camphorquinone/amine photo-initiator system. in Journal of Dentistry
Elsevier Sci Ltd, Oxford., 41(10), 918-926.
https://doi.org/10.1016/j.jdent.2013.07.007
Miletić V, Pongprueksa P, de Munck J, Brooks NR, Van Meerbeek B. Monomer-to-polymer conversion and micro-tensile bond strength to dentine of experimental and commercial adhesives containing diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide or a camphorquinone/amine photo-initiator system. in Journal of Dentistry. 2013;41(10):918-926.
doi:10.1016/j.jdent.2013.07.007 .
Miletić, Vesna, Pongprueksa, Pong, de Munck, Jan, Brooks, Neil R., Van Meerbeek, Bart, "Monomer-to-polymer conversion and micro-tensile bond strength to dentine of experimental and commercial adhesives containing diphenyl(2,4,6-trimethylbenzoyl)phosphine oxide or a camphorquinone/amine photo-initiator system" in Journal of Dentistry, 41, no. 10 (2013):918-926,
https://doi.org/10.1016/j.jdent.2013.07.007 . .
27
20
23