Sinobad, Tamara

Link to this page

Authority KeyName Variants
2da8702e-15b0-4093-965c-b9c18a21832f
  • Sinobad, Tamara (4)
Projects
No records found.

Author's Bibliography

Skeletal changes in patients with mandibular prognathism after mandibular set back and bimaxillary surgery: A comparative cephalometric study

Sinobad, Vladimir; Strajnić, Ljiljana; Sinobad, Tamara

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2020)

TY  - JOUR
AU  - Sinobad, Vladimir
AU  - Strajnić, Ljiljana
AU  - Sinobad, Tamara
PY  - 2020
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2495
AB  - Bacground/Aim. Recently, maxillary and bimaxillary surgery gained the primacy in the surgical correction of class III deformities. The aim of this investigation was to compare the changes in the skeletal relationships in patients with mandibular prognathism after bimaxillary surgery. Methods. The study included 70 subjects divided into three groups. Twenty class III patients of the experimental group 1 underwent bilateral sagittal ramus osteotomy and twenty patients of the experimental group 2 were subjected to bimaxillary surgery. The control group consisted of 30 subjects with skeletal class I and physiological occlusion. Cephalometric research was conducted on 110 lateral cephalometric radiographs made in subjects of the experimental groups 1 and 2 before and after surgery and in subjects of the control group. Using the computer program "Dr. Ceph", 30 linear and angular skeletal variables were analyzed on each radiograph. Results. Bimaxillary osteotomies changed most of variables that characterize the mandibular prognathism. The changes in the sagittal plane included the significant increase of sella-nasion to the A point (SNA) angle (by 4º on the average) and the A point to B point (ANB) angle (6°), and significant reduction in angles sellanasion to the B point (SNB) (3º), gonial angle (ArGoMe) (8°), gonial angle inferior (NGoMe) (6.2º), and Björks sum (7°). The vertical relationships were normalized by significant reduction in overall anterior face height N-Me (by 5 mm on the average), the lower anterior face height ANS-Me (4 mm), significant increase in the total posterior face height S-Go (2.5-3 mm), lower posterior face height PNS-Go (4 mm), and significant reduction of the basal and mandibular plane angles. Conclusion. Compared to the isolated mandibular operations, bimaxillary surgery changes more efficiently the sagittal and vertical skeletal relations in patients with class III deformities and harmonizes more successfully the entire skeletal facial profile.
AB  - Uvod/Cilj. Maksilarna i bimaksilarna hirurgija dobila je nedavno primat u hirurškim korekcijama deformiteta klase III. Cilj ovog istraživanja je bio da se uporede promene u skeletnim odnosima kod bolesnika sa mandibularnim prognatizmom posle bimaksilarne operacije. Metode. Ispitivanjem je obuhvaćeno 70 ispitanika podeljenih u tri grupe. Dvadeset ispitanika klase III eksperimentalne grupe 1 podvrgnuto je bilateralnoj sagitalnoj ramus osteotomiji, a dvadeset ispitanika eksperimentalne grupe 2 podvrgnuto je bimaksilarnoj operaciji. Kontrolnu grupu činilo je 30 ispitanika sa skeletnom klasom I i fiziološkom okluzijom. Rendgen-kraniometrijsko istraživanje obavljeno je na 110 bočnih telerendgen snimaka urađenih kod ispitanika u eksperimentalnim grupama 1 i 2 pre i posle operacije i ispitanika kontrolne grupe. Koristeći kompjuterski program "Dr.Ceph", na svakom telerendgenu analizirano je 30 linearnih i ugaonih skeletnih varijabli. Rezultati. Bimaksilarna osteotomija promenila je većinu varijabli koje karakterišu mandibularni prognatizam. Promene u sagitalnoj ravni uključuju značajan porast ugla maksilarnog prognatizma (SNA) (od 4º u proseku) i ugla gagitalnog odnosa tela gornje i donje vilice (ANB) ugla (6°), značajno smanjenje uglova ugao mandibularnog prognatizma (SNB) (3º), ganialnog ugla (ArGoMe) (8°), donjeg gonialnog ugla (NGoMe) (6,2º), i Bjorkovog poligona (7°). Vertikalni odnosi su normalizovani značajnim smanjenjem ukupne prednje visine lica NMe (od 5 mm u proseku), prednje donje visine lica (ANBMe) (4 mm), povećanjem ukupne zadnje visine lica M-Go (2,5-3 mm), zadnje donje visine lice PNS-Go (4 mm), i značajnim smanjenjem mandibularnih uglova. Zaključak. U poređenju sa izolovanom mandibularnom operacijom bimaksilarna hirurgija menja efikasnije sagitalne i vertikalne skeletne odnose kod bolesnik sa deformitetima klase III i uspešnije harmonizuje ceo skeletni profil lica.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - Skeletal changes in patients with mandibular prognathism after mandibular set back and bimaxillary surgery: A comparative cephalometric study
T1  - Skeletne promene kod bolesnika sa mandibularnim prognatizmom nakon mandibularne i bimaksilarne hirurgije - komparativna rendgenkraniometrijska studija
VL  - 77
IS  - 4
SP  - 395
EP  - 404
DO  - 10.2298/VSP171017087S
ER  - 
@article{
author = "Sinobad, Vladimir and Strajnić, Ljiljana and Sinobad, Tamara",
year = "2020",
abstract = "Bacground/Aim. Recently, maxillary and bimaxillary surgery gained the primacy in the surgical correction of class III deformities. The aim of this investigation was to compare the changes in the skeletal relationships in patients with mandibular prognathism after bimaxillary surgery. Methods. The study included 70 subjects divided into three groups. Twenty class III patients of the experimental group 1 underwent bilateral sagittal ramus osteotomy and twenty patients of the experimental group 2 were subjected to bimaxillary surgery. The control group consisted of 30 subjects with skeletal class I and physiological occlusion. Cephalometric research was conducted on 110 lateral cephalometric radiographs made in subjects of the experimental groups 1 and 2 before and after surgery and in subjects of the control group. Using the computer program "Dr. Ceph", 30 linear and angular skeletal variables were analyzed on each radiograph. Results. Bimaxillary osteotomies changed most of variables that characterize the mandibular prognathism. The changes in the sagittal plane included the significant increase of sella-nasion to the A point (SNA) angle (by 4º on the average) and the A point to B point (ANB) angle (6°), and significant reduction in angles sellanasion to the B point (SNB) (3º), gonial angle (ArGoMe) (8°), gonial angle inferior (NGoMe) (6.2º), and Björks sum (7°). The vertical relationships were normalized by significant reduction in overall anterior face height N-Me (by 5 mm on the average), the lower anterior face height ANS-Me (4 mm), significant increase in the total posterior face height S-Go (2.5-3 mm), lower posterior face height PNS-Go (4 mm), and significant reduction of the basal and mandibular plane angles. Conclusion. Compared to the isolated mandibular operations, bimaxillary surgery changes more efficiently the sagittal and vertical skeletal relations in patients with class III deformities and harmonizes more successfully the entire skeletal facial profile., Uvod/Cilj. Maksilarna i bimaksilarna hirurgija dobila je nedavno primat u hirurškim korekcijama deformiteta klase III. Cilj ovog istraživanja je bio da se uporede promene u skeletnim odnosima kod bolesnika sa mandibularnim prognatizmom posle bimaksilarne operacije. Metode. Ispitivanjem je obuhvaćeno 70 ispitanika podeljenih u tri grupe. Dvadeset ispitanika klase III eksperimentalne grupe 1 podvrgnuto je bilateralnoj sagitalnoj ramus osteotomiji, a dvadeset ispitanika eksperimentalne grupe 2 podvrgnuto je bimaksilarnoj operaciji. Kontrolnu grupu činilo je 30 ispitanika sa skeletnom klasom I i fiziološkom okluzijom. Rendgen-kraniometrijsko istraživanje obavljeno je na 110 bočnih telerendgen snimaka urađenih kod ispitanika u eksperimentalnim grupama 1 i 2 pre i posle operacije i ispitanika kontrolne grupe. Koristeći kompjuterski program "Dr.Ceph", na svakom telerendgenu analizirano je 30 linearnih i ugaonih skeletnih varijabli. Rezultati. Bimaksilarna osteotomija promenila je većinu varijabli koje karakterišu mandibularni prognatizam. Promene u sagitalnoj ravni uključuju značajan porast ugla maksilarnog prognatizma (SNA) (od 4º u proseku) i ugla gagitalnog odnosa tela gornje i donje vilice (ANB) ugla (6°), značajno smanjenje uglova ugao mandibularnog prognatizma (SNB) (3º), ganialnog ugla (ArGoMe) (8°), donjeg gonialnog ugla (NGoMe) (6,2º), i Bjorkovog poligona (7°). Vertikalni odnosi su normalizovani značajnim smanjenjem ukupne prednje visine lica NMe (od 5 mm u proseku), prednje donje visine lica (ANBMe) (4 mm), povećanjem ukupne zadnje visine lica M-Go (2,5-3 mm), zadnje donje visine lice PNS-Go (4 mm), i značajnim smanjenjem mandibularnih uglova. Zaključak. U poređenju sa izolovanom mandibularnom operacijom bimaksilarna hirurgija menja efikasnije sagitalne i vertikalne skeletne odnose kod bolesnik sa deformitetima klase III i uspešnije harmonizuje ceo skeletni profil lica.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "Skeletal changes in patients with mandibular prognathism after mandibular set back and bimaxillary surgery: A comparative cephalometric study, Skeletne promene kod bolesnika sa mandibularnim prognatizmom nakon mandibularne i bimaksilarne hirurgije - komparativna rendgenkraniometrijska studija",
volume = "77",
number = "4",
pages = "395-404",
doi = "10.2298/VSP171017087S"
}
Sinobad, V., Strajnić, L.,& Sinobad, T.. (2020). Skeletal changes in patients with mandibular prognathism after mandibular set back and bimaxillary surgery: A comparative cephalometric study. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 77(4), 395-404.
https://doi.org/10.2298/VSP171017087S
Sinobad V, Strajnić L, Sinobad T. Skeletal changes in patients with mandibular prognathism after mandibular set back and bimaxillary surgery: A comparative cephalometric study. in Vojnosanitetski pregled. 2020;77(4):395-404.
doi:10.2298/VSP171017087S .
Sinobad, Vladimir, Strajnić, Ljiljana, Sinobad, Tamara, "Skeletal changes in patients with mandibular prognathism after mandibular set back and bimaxillary surgery: A comparative cephalometric study" in Vojnosanitetski pregled, 77, no. 4 (2020):395-404,
https://doi.org/10.2298/VSP171017087S . .
2
1
2

Evaluation of photometric methods in assessment of dimensional stability of elastomeric impression materials

Sinobad, Tamara

(Univerzitet u Beogradu, Stomatološki fakultet, 2016)

TY  - THES
AU  - Sinobad, Tamara
PY  - 2016
UR  - http://eteze.bg.ac.rs/application/showtheses?thesesId=3935
UR  - https://fedorabg.bg.ac.rs/fedora/get/o:13235/bdef:Content/download
UR  - https://fedorabg.bg.ac.rs/fedora/get/o:13308/bdef:Izvestaj/download
UR  - http://vbs.rs/scripts/cobiss?command=DISPLAY&base=70036&RID=48250127
UR  - http://nardus.mpn.gov.rs/123456789/6744
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/992
AB  - Dental impression materials are used to reproduce the form and relations of teeth and  surrounding oral tissues, and the impressions are used for fabricating diagnostic and  master casts. Dimensional stability of elastomeric impression materials under various  conditions, is pivotal factor for the accuracy and durability of the final prosthetic  restorations. It is defined as the ability of a material to retain its size and form over time.  The aim of this study was to evaluate different possibilities of the original photometric  methods in assessment of dimensional stability of elastomeric impression materials and  to determine their efficiency and precision in comparison with the reference method  recommended by the valid standards for dental elastomeric impression materials (ISO  4823:2000, ANSI/ADA Specification No.19).  Five elastomeric impression materials were used in this study: two condensation  silicones (Oranwash L - Zhermack and Xantopren L blue - Heraeus Kulzer), two  addition silicones (Elite HD + light body - Zhermack and Variotime Light Flow -  Heraeus Kulzer) and one polyether (ImpregumTM Soft 3M ESPE). A specific stainless  steel test block, made according to the recommendations of ISO standard, was used for  the fabrication of the samples of tested impression materials. Dimensional stability of  the impression materials was examined as a function of time (5min, 30min, 1h and 24h  after removal from the test block) at the temperatures of 23ºC, 35ºC and 40ºC. The  effect of each applied disinfectant (5.25% NaOCl, glutaraldehyde, benzalkonium  chloride – Sterigum and aerosol with ethanol and isopropanol - Zeta 7) was tested as well..
AB  - U stomatologiji se otisni materijali upotrebljavaju za reprodukciju oblika i odnosa zuba i  okolnih oralnih tkiva, a dobijeni otisci se koriste za izradu dijagnostičkih i master  modela. Dimenzionalna stabilnost elastomernih otisnih materijala u različitim uslovima,  važan je faktor koji direktno utiče na preciznost i trajnost indirektno izrađenih  definitivnih zubnih nadoknada. Definiše se kao sposobnost materijala da zadrži svoju  veličinu i oblik tokom vremena.  Cilj ovog istraživanja je ispitivanje različitih mogućnosti originalnih fotometrijskih  metoda u proceni dimenzionalne stabilnosti elastomernih otisnih materijala i utvrđivanje  njihove efikasnosti i preciznosti u poređenju sa referentnom metodom koju preporučuju  važeći standardi za elastomerne otisne materijale u stomatologiji (ISO 4823:2000,  ANSI/ADA Specifikacija br.19).  Za potrebe ovog istraživanja korišćeno je pet elastomernih otisnih materijala: dva  kondenzaciona silikona (Oranwash L–Zhermack i Xantopren L blue–Heraeus Kulzer),  dva adiciona silikona (Elite HD+ light body–Zhermack i Variotime Light Flow–Heraeus  Kulzer) i jedan polietar (ImpregumTM Soft 3M ESPE). Uzorci ispitivanih otisnih  materijala dobijeni su iz specijalne modle od nerđajućeg čelika koja je izrađena prema  preporukama važećih standarda. Dimenzionalna stabilnost otisnih materijala ispitana je  u zavisnosti od vremena (5min, 30min, 60min i 24h od momenta odvajanja otiska od  modle), pri temperaturama od 23ºC, 35ºC i 40ºC, kao i pod uticajem različitih  dezinficijenasa (5,25% NaOCl, glutaraldehid, benzalkonijum hlorid –Sterigum i sprej na  bazi etanola i izopropanola – Zeta 7)...
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Evaluation of photometric methods in assessment of dimensional stability of elastomeric impression materials
T1  - Evaluacija fotometrijskih metoda u ispitivanju dimenzionalne stabilnosti elastomernih otisnih materijala
UR  - https://hdl.handle.net/21.15107/rcub_nardus_6744
ER  - 
@phdthesis{
author = "Sinobad, Tamara",
year = "2016",
abstract = "Dental impression materials are used to reproduce the form and relations of teeth and  surrounding oral tissues, and the impressions are used for fabricating diagnostic and  master casts. Dimensional stability of elastomeric impression materials under various  conditions, is pivotal factor for the accuracy and durability of the final prosthetic  restorations. It is defined as the ability of a material to retain its size and form over time.  The aim of this study was to evaluate different possibilities of the original photometric  methods in assessment of dimensional stability of elastomeric impression materials and  to determine their efficiency and precision in comparison with the reference method  recommended by the valid standards for dental elastomeric impression materials (ISO  4823:2000, ANSI/ADA Specification No.19).  Five elastomeric impression materials were used in this study: two condensation  silicones (Oranwash L - Zhermack and Xantopren L blue - Heraeus Kulzer), two  addition silicones (Elite HD + light body - Zhermack and Variotime Light Flow -  Heraeus Kulzer) and one polyether (ImpregumTM Soft 3M ESPE). A specific stainless  steel test block, made according to the recommendations of ISO standard, was used for  the fabrication of the samples of tested impression materials. Dimensional stability of  the impression materials was examined as a function of time (5min, 30min, 1h and 24h  after removal from the test block) at the temperatures of 23ºC, 35ºC and 40ºC. The  effect of each applied disinfectant (5.25% NaOCl, glutaraldehyde, benzalkonium  chloride – Sterigum and aerosol with ethanol and isopropanol - Zeta 7) was tested as well.., U stomatologiji se otisni materijali upotrebljavaju za reprodukciju oblika i odnosa zuba i  okolnih oralnih tkiva, a dobijeni otisci se koriste za izradu dijagnostičkih i master  modela. Dimenzionalna stabilnost elastomernih otisnih materijala u različitim uslovima,  važan je faktor koji direktno utiče na preciznost i trajnost indirektno izrađenih  definitivnih zubnih nadoknada. Definiše se kao sposobnost materijala da zadrži svoju  veličinu i oblik tokom vremena.  Cilj ovog istraživanja je ispitivanje različitih mogućnosti originalnih fotometrijskih  metoda u proceni dimenzionalne stabilnosti elastomernih otisnih materijala i utvrđivanje  njihove efikasnosti i preciznosti u poređenju sa referentnom metodom koju preporučuju  važeći standardi za elastomerne otisne materijale u stomatologiji (ISO 4823:2000,  ANSI/ADA Specifikacija br.19).  Za potrebe ovog istraživanja korišćeno je pet elastomernih otisnih materijala: dva  kondenzaciona silikona (Oranwash L–Zhermack i Xantopren L blue–Heraeus Kulzer),  dva adiciona silikona (Elite HD+ light body–Zhermack i Variotime Light Flow–Heraeus  Kulzer) i jedan polietar (ImpregumTM Soft 3M ESPE). Uzorci ispitivanih otisnih  materijala dobijeni su iz specijalne modle od nerđajućeg čelika koja je izrađena prema  preporukama važećih standarda. Dimenzionalna stabilnost otisnih materijala ispitana je  u zavisnosti od vremena (5min, 30min, 60min i 24h od momenta odvajanja otiska od  modle), pri temperaturama od 23ºC, 35ºC i 40ºC, kao i pod uticajem različitih  dezinficijenasa (5,25% NaOCl, glutaraldehid, benzalkonijum hlorid –Sterigum i sprej na  bazi etanola i izopropanola – Zeta 7)...",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Evaluation of photometric methods in assessment of dimensional stability of elastomeric impression materials, Evaluacija fotometrijskih metoda u ispitivanju dimenzionalne stabilnosti elastomernih otisnih materijala",
url = "https://hdl.handle.net/21.15107/rcub_nardus_6744"
}
Sinobad, T.. (2016). Evaluation of photometric methods in assessment of dimensional stability of elastomeric impression materials. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_nardus_6744
Sinobad T. Evaluation of photometric methods in assessment of dimensional stability of elastomeric impression materials. 2016;.
https://hdl.handle.net/21.15107/rcub_nardus_6744 .
Sinobad, Tamara, "Evaluation of photometric methods in assessment of dimensional stability of elastomeric impression materials" (2016),
https://hdl.handle.net/21.15107/rcub_nardus_6744 .

The effect of disinfectants on dimensional stability of addition and condensation silicone impressions

Sinobad, Tamara; Obradović-Đuričić, Kosovka; Nikolić, Zoran; Dodić, Slobodan; Lazić, Vojkan; Sinobad, Vladimir; Jesenko-Rokvić, Aleksandra

(Vojnomedicinska akademija - Institut za naučne informacije, Beograd, 2014)

TY  - JOUR
AU  - Sinobad, Tamara
AU  - Obradović-Đuričić, Kosovka
AU  - Nikolić, Zoran
AU  - Dodić, Slobodan
AU  - Lazić, Vojkan
AU  - Sinobad, Vladimir
AU  - Jesenko-Rokvić, Aleksandra
PY  - 2014
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1875
AB  - Background/Aim. Dimensional stability and accuracy of an impression after chemical disinfection by immersion in disinfectants are crucial for the accuracy of final prosthetic restorations. The aim of this study was to assess the deformation of addition and condensation silicone impressions after disinfection in antimicrobial solutions. Methods. A total of 120 impressions were made on the model of the upper arch representing three full metal-ceramic crown preparations. Four impression materials were used: two condensation silicones (Oranwash L - Zhermack and Xantopren L Blue - Heraeus Kulzer) and two addition silicones (Elite H-D + regular body - Zhermack and Flexitime correct flow - Heraeus Kulzer). After removal from the model the impressions were immediately immersed in appropriate disinfectant (glutaraldehyde, benzalkonium chloride - Sterigum and 5.25% NaOCl) for a period of 10 min. The control group consisted of samples that were not treated with disinfectant solution. Consecutive measurements of identical impressions were realized with a Canon G9 (12 megapixels, 2 fps, 6x/24x), and automated with a computer Asus Lamborghini VX-2R Intel C2D 2.4 GHz, by using Remote Capture software package, so that time-depending series of images of the same impression were obtained. Results. The dimensional changes of all the samples were significant both as a function of time and the applied disinfectant. The results show significant differences of the obtained dimensional changes between the group of condensation silicones and the group of addition silicones for the same time, and the same applied disinfectant (p = 0.026, F = 3.95). Conclusion. The greatest dimensional changes of addition and condensation silicone impressions appear in the first hour after their separation from the model.
AB  - Uvod/Cilj. Dimenzionalna stabilnost i preciznost otiska posle hemijske dezinfekcije potapanjem u dezinficijens predstavljaju osnovu za preciznost definitivnih zubnih nadoknada. Cilj ovog istraživanja bio je da se proceni dimenzionalna stabilnost otisaka izrađenih od adicionih i kondenzacionih silikona posle dezinfekcije u antimikrobnim rastvorima. Metode. Napravljen je uzorak od 120 otisaka, dobijenih otiskivanjem modela gornje vilice sa ispreparisanim zubima za metalokeramičke krune. Od otisnih materijala korišćena su dva kondenzaciona silikona (Oranwash L - Zhermack i Xantopren L Blue - Heraeus Kulzer) i dva adiciona silikona (Elite H-D + regular body - Zhermack i Flexitime correct flow - Heraeus Kulzer). Odmah po odvajanju od modela, otisci su potopljeni u odgovarajući dezinficijens (glutaraldehid, benzalkonijum-hlorid - Sterigum i 5,25% NaOCl) u trajanju od 10 min. Kontrolnu grupu činili su uzorci koji nisu tretirani dezinficijensom. Uzastopna merenja istovetnih otisaka vršena su pomoću fotoaparata Canon G9 (12 megapiksela, 2 fps, 6x/24x), a automatizovana sa računara Asus VX 2R Lamborghini- Intel C2D 2,4 GHz, korišćenjem opcija softverskog paketa Remote Capture tako da su dobijene vremenske serije fotografija istog otiska. Rezultati. Utvrđene su izražene dimenzionalne promene svih uzoraka kako u funkciji vremena tako i u funkciji primenjenog dezinficijensa. Rezultati pokazuju postojanje značajnih razlika dimenzionalnih promena između grupe kondenzacionih silikona i grupe adicionih silikona za isto vreme i isti primenjeni dezinficijens (p = 0,026, F = 3,95). Zaključak. Najveće dimenzionalne promene otisaka uzetih adicionim i kondenzacionim silikonima beleže se u prvom satu po odvajanju sa modela.
PB  - Vojnomedicinska akademija - Institut za naučne informacije, Beograd
T2  - Vojnosanitetski pregled
T1  - The effect of disinfectants on dimensional stability of addition and condensation silicone impressions
T1  - Uticaj dezinficijenasa na dimenzionalnu stabilnost otisaka izrađenih od adicionih i kondenzacionih silikona
VL  - 71
IS  - 3
SP  - 251
EP  - 258
DO  - 10.2298/VSP120709037S
ER  - 
@article{
author = "Sinobad, Tamara and Obradović-Đuričić, Kosovka and Nikolić, Zoran and Dodić, Slobodan and Lazić, Vojkan and Sinobad, Vladimir and Jesenko-Rokvić, Aleksandra",
year = "2014",
abstract = "Background/Aim. Dimensional stability and accuracy of an impression after chemical disinfection by immersion in disinfectants are crucial for the accuracy of final prosthetic restorations. The aim of this study was to assess the deformation of addition and condensation silicone impressions after disinfection in antimicrobial solutions. Methods. A total of 120 impressions were made on the model of the upper arch representing three full metal-ceramic crown preparations. Four impression materials were used: two condensation silicones (Oranwash L - Zhermack and Xantopren L Blue - Heraeus Kulzer) and two addition silicones (Elite H-D + regular body - Zhermack and Flexitime correct flow - Heraeus Kulzer). After removal from the model the impressions were immediately immersed in appropriate disinfectant (glutaraldehyde, benzalkonium chloride - Sterigum and 5.25% NaOCl) for a period of 10 min. The control group consisted of samples that were not treated with disinfectant solution. Consecutive measurements of identical impressions were realized with a Canon G9 (12 megapixels, 2 fps, 6x/24x), and automated with a computer Asus Lamborghini VX-2R Intel C2D 2.4 GHz, by using Remote Capture software package, so that time-depending series of images of the same impression were obtained. Results. The dimensional changes of all the samples were significant both as a function of time and the applied disinfectant. The results show significant differences of the obtained dimensional changes between the group of condensation silicones and the group of addition silicones for the same time, and the same applied disinfectant (p = 0.026, F = 3.95). Conclusion. The greatest dimensional changes of addition and condensation silicone impressions appear in the first hour after their separation from the model., Uvod/Cilj. Dimenzionalna stabilnost i preciznost otiska posle hemijske dezinfekcije potapanjem u dezinficijens predstavljaju osnovu za preciznost definitivnih zubnih nadoknada. Cilj ovog istraživanja bio je da se proceni dimenzionalna stabilnost otisaka izrađenih od adicionih i kondenzacionih silikona posle dezinfekcije u antimikrobnim rastvorima. Metode. Napravljen je uzorak od 120 otisaka, dobijenih otiskivanjem modela gornje vilice sa ispreparisanim zubima za metalokeramičke krune. Od otisnih materijala korišćena su dva kondenzaciona silikona (Oranwash L - Zhermack i Xantopren L Blue - Heraeus Kulzer) i dva adiciona silikona (Elite H-D + regular body - Zhermack i Flexitime correct flow - Heraeus Kulzer). Odmah po odvajanju od modela, otisci su potopljeni u odgovarajući dezinficijens (glutaraldehid, benzalkonijum-hlorid - Sterigum i 5,25% NaOCl) u trajanju od 10 min. Kontrolnu grupu činili su uzorci koji nisu tretirani dezinficijensom. Uzastopna merenja istovetnih otisaka vršena su pomoću fotoaparata Canon G9 (12 megapiksela, 2 fps, 6x/24x), a automatizovana sa računara Asus VX 2R Lamborghini- Intel C2D 2,4 GHz, korišćenjem opcija softverskog paketa Remote Capture tako da su dobijene vremenske serije fotografija istog otiska. Rezultati. Utvrđene su izražene dimenzionalne promene svih uzoraka kako u funkciji vremena tako i u funkciji primenjenog dezinficijensa. Rezultati pokazuju postojanje značajnih razlika dimenzionalnih promena između grupe kondenzacionih silikona i grupe adicionih silikona za isto vreme i isti primenjeni dezinficijens (p = 0,026, F = 3,95). Zaključak. Najveće dimenzionalne promene otisaka uzetih adicionim i kondenzacionim silikonima beleže se u prvom satu po odvajanju sa modela.",
publisher = "Vojnomedicinska akademija - Institut za naučne informacije, Beograd",
journal = "Vojnosanitetski pregled",
title = "The effect of disinfectants on dimensional stability of addition and condensation silicone impressions, Uticaj dezinficijenasa na dimenzionalnu stabilnost otisaka izrađenih od adicionih i kondenzacionih silikona",
volume = "71",
number = "3",
pages = "251-258",
doi = "10.2298/VSP120709037S"
}
Sinobad, T., Obradović-Đuričić, K., Nikolić, Z., Dodić, S., Lazić, V., Sinobad, V.,& Jesenko-Rokvić, A.. (2014). The effect of disinfectants on dimensional stability of addition and condensation silicone impressions. in Vojnosanitetski pregled
Vojnomedicinska akademija - Institut za naučne informacije, Beograd., 71(3), 251-258.
https://doi.org/10.2298/VSP120709037S
Sinobad T, Obradović-Đuričić K, Nikolić Z, Dodić S, Lazić V, Sinobad V, Jesenko-Rokvić A. The effect of disinfectants on dimensional stability of addition and condensation silicone impressions. in Vojnosanitetski pregled. 2014;71(3):251-258.
doi:10.2298/VSP120709037S .
Sinobad, Tamara, Obradović-Đuričić, Kosovka, Nikolić, Zoran, Dodić, Slobodan, Lazić, Vojkan, Sinobad, Vladimir, Jesenko-Rokvić, Aleksandra, "The effect of disinfectants on dimensional stability of addition and condensation silicone impressions" in Vojnosanitetski pregled, 71, no. 3 (2014):251-258,
https://doi.org/10.2298/VSP120709037S . .
1
20
11
19

Analiza dimenzionalne stabilnosti elastomernih otisnih materijala

Sinobad, Tamara

(Univerzitet u Beogradu, Stomatološki fakultet, 2010)

TY  - THES
AU  - Sinobad, Tamara
PY  - 2010
UR  - https://plus.sr.cobiss.net/opac7/bib/1024104078
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/493
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Analiza dimenzionalne stabilnosti elastomernih otisnih materijala
UR  - https://hdl.handle.net/21.15107/rcub_smile_493
ER  - 
@mastersthesis{
author = "Sinobad, Tamara",
year = "2010",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Analiza dimenzionalne stabilnosti elastomernih otisnih materijala",
url = "https://hdl.handle.net/21.15107/rcub_smile_493"
}
Sinobad, T.. (2010). Analiza dimenzionalne stabilnosti elastomernih otisnih materijala. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_493
Sinobad T. Analiza dimenzionalne stabilnosti elastomernih otisnih materijala. 2010;.
https://hdl.handle.net/21.15107/rcub_smile_493 .
Sinobad, Tamara, "Analiza dimenzionalne stabilnosti elastomernih otisnih materijala" (2010),
https://hdl.handle.net/21.15107/rcub_smile_493 .