Krstanović, Goranka

Link to this page

Authority KeyName Variants
4c848cc8-fbfe-499c-ad82-ae4833f61ab6
  • Krstanović, Goranka (3)
Projects
No records found.

Author's Bibliography

Light transmission through fiber post: The effect on adhesion, elastic modulus and hardness of dual-cure resin cement

Radović, Ivana; Corciolani, Gabriele; Magni, Elisa; Krstanović, Goranka; Pavlović, Vladimir; Vulićević, Zoran; Ferrari, Marco

(Elsevier Sci Ltd, Oxford, 2009)

TY  - JOUR
AU  - Radović, Ivana
AU  - Corciolani, Gabriele
AU  - Magni, Elisa
AU  - Krstanović, Goranka
AU  - Pavlović, Vladimir
AU  - Vulićević, Zoran
AU  - Ferrari, Marco
PY  - 2009
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1487
AB  - Objectives. The aim of this study was to investigate the effect of fiber post light transmitting ability to the continuity of resin cement-root dentin (C-RD) and resin cement-fiber post (C-FP) interface, elastic modulus and hardness of a dual-cure resin cement. Methods. Spectrophotometric measurements were applied for the determination of light transmission at coronal, middle and apical level as well as at the apical tip through Tech 21 X-OP (TECH) and DT Light Post (DT). Posts were cemented using dual-cured resin cement (Calibra). Roots were sectioned longitudinally through the post. Epoxy resin replicas were made and used to evaluate C-RD and C-FP interface under SEM. Modulus of elasticity (E) and Vicker's hardness (VH) of the cement layer were assessed. Results. No light transmission was detected through TECH. Light transmission through DT decreased from coronal to apical and rose at the apical tip. TECH presented a significantly lower percentage of continuous C-RD and C-FP interface in comparison to DT. Coronal third of C-RD interface in TECH specimens had a significantly higher percentage of continuity than apical third. No regional differences in continuity of C-RD interface were found in DT specimens. E and VH were significantly lower when TECH was used, and decreased from coronal to apical for both posts. Significance. Cementation of fiber post with no light transmitting ability using a dual-cured resin cement resulted in lower E and VH of the cement layer, and lower percentage of continuous C-RD and C-FP interface in comparison to cementation of light transmitting fiber post.
PB  - Elsevier Sci Ltd, Oxford
T2  - Dental Materials
T1  - Light transmission through fiber post: The effect on adhesion, elastic modulus and hardness of dual-cure resin cement
VL  - 25
IS  - 7
SP  - 837
EP  - 844
DO  - 10.1016/j.dental.2009.01.004
ER  - 
@article{
author = "Radović, Ivana and Corciolani, Gabriele and Magni, Elisa and Krstanović, Goranka and Pavlović, Vladimir and Vulićević, Zoran and Ferrari, Marco",
year = "2009",
abstract = "Objectives. The aim of this study was to investigate the effect of fiber post light transmitting ability to the continuity of resin cement-root dentin (C-RD) and resin cement-fiber post (C-FP) interface, elastic modulus and hardness of a dual-cure resin cement. Methods. Spectrophotometric measurements were applied for the determination of light transmission at coronal, middle and apical level as well as at the apical tip through Tech 21 X-OP (TECH) and DT Light Post (DT). Posts were cemented using dual-cured resin cement (Calibra). Roots were sectioned longitudinally through the post. Epoxy resin replicas were made and used to evaluate C-RD and C-FP interface under SEM. Modulus of elasticity (E) and Vicker's hardness (VH) of the cement layer were assessed. Results. No light transmission was detected through TECH. Light transmission through DT decreased from coronal to apical and rose at the apical tip. TECH presented a significantly lower percentage of continuous C-RD and C-FP interface in comparison to DT. Coronal third of C-RD interface in TECH specimens had a significantly higher percentage of continuity than apical third. No regional differences in continuity of C-RD interface were found in DT specimens. E and VH were significantly lower when TECH was used, and decreased from coronal to apical for both posts. Significance. Cementation of fiber post with no light transmitting ability using a dual-cured resin cement resulted in lower E and VH of the cement layer, and lower percentage of continuous C-RD and C-FP interface in comparison to cementation of light transmitting fiber post.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Dental Materials",
title = "Light transmission through fiber post: The effect on adhesion, elastic modulus and hardness of dual-cure resin cement",
volume = "25",
number = "7",
pages = "837-844",
doi = "10.1016/j.dental.2009.01.004"
}
Radović, I., Corciolani, G., Magni, E., Krstanović, G., Pavlović, V., Vulićević, Z.,& Ferrari, M.. (2009). Light transmission through fiber post: The effect on adhesion, elastic modulus and hardness of dual-cure resin cement. in Dental Materials
Elsevier Sci Ltd, Oxford., 25(7), 837-844.
https://doi.org/10.1016/j.dental.2009.01.004
Radović I, Corciolani G, Magni E, Krstanović G, Pavlović V, Vulićević Z, Ferrari M. Light transmission through fiber post: The effect on adhesion, elastic modulus and hardness of dual-cure resin cement. in Dental Materials. 2009;25(7):837-844.
doi:10.1016/j.dental.2009.01.004 .
Radović, Ivana, Corciolani, Gabriele, Magni, Elisa, Krstanović, Goranka, Pavlović, Vladimir, Vulićević, Zoran, Ferrari, Marco, "Light transmission through fiber post: The effect on adhesion, elastic modulus and hardness of dual-cure resin cement" in Dental Materials, 25, no. 7 (2009):837-844,
https://doi.org/10.1016/j.dental.2009.01.004 . .
57
45
53

Zastupljenost povreda čvrstih zubnih tkiva u dece

Krstanović, Goranka

(Univerzitet u Beogradu, Stomatološki fakultet, 2009)

TY  - THES
AU  - Krstanović, Goranka
PY  - 2009
UR  - https://plus.sr.cobiss.net/opac7/bib/1024101518
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/483
PB  - Univerzitet u Beogradu, Stomatološki fakultet
T1  - Zastupljenost povreda čvrstih zubnih tkiva u dece
UR  - https://hdl.handle.net/21.15107/rcub_smile_483
ER  - 
@mastersthesis{
author = "Krstanović, Goranka",
year = "2009",
publisher = "Univerzitet u Beogradu, Stomatološki fakultet",
title = "Zastupljenost povreda čvrstih zubnih tkiva u dece",
url = "https://hdl.handle.net/21.15107/rcub_smile_483"
}
Krstanović, G.. (2009). Zastupljenost povreda čvrstih zubnih tkiva u dece. 
Univerzitet u Beogradu, Stomatološki fakultet..
https://hdl.handle.net/21.15107/rcub_smile_483
Krstanović G. Zastupljenost povreda čvrstih zubnih tkiva u dece. 2009;.
https://hdl.handle.net/21.15107/rcub_smile_483 .
Krstanović, Goranka, "Zastupljenost povreda čvrstih zubnih tkiva u dece" (2009),
https://hdl.handle.net/21.15107/rcub_smile_483 .

Microtensile bond strength of self-etching adhesives to dentin

Vulićević, Zoran; Radović, Ivana; Krstanović, Goranka; Mandić, Jelena; Cury, Alvaro Hafiz; Ferrari, Marco

(Savez inženjera metalurgije Srbije, Beograd, 2008)

TY  - JOUR
AU  - Vulićević, Zoran
AU  - Radović, Ivana
AU  - Krstanović, Goranka
AU  - Mandić, Jelena
AU  - Cury, Alvaro Hafiz
AU  - Ferrari, Marco
PY  - 2008
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1404
AB  - The aim of this study was to determine micro tensile bond strength of two and one-step self-etching adhesive systems to dentin. 25 intact human third molars were used. Flat surfaces of mid-coronal dentin were exposed and the teeth were divided into 5 groups (n=5). Composite build-ups were made using the following self-etching systems / composite materials: 2-step self-etching system Contax / Ecusphere Carat (DMG), 2-step self-etching system AdheSE / Tetric Ceram (Ivoclar Vivadent), 1-step 2-components self etching system Futurabond NR / Grandio (Voco) and 1-step 1-component self-etching adhesive G Bond / Gradia Direct (GC Corp.). Two-step etch-and-rinse system PQ Clear with Amelogen Universal composite resin (Ultra dent) was used in the control group. Bond strength was assessed with the non-trimming micro tensile technique. Statistical analysis was performed using the 1-way ANOVA, followed by the Tukey test for post-hoc comparisons (p lt 0.05). Investigated self-etching systems showed satisfactory values of micro tensile bond strength to dentin after 24 hours. Two-step self-etching system AdheSE resulted in significantly higher bond strength than all the other groups (p lt 0.001). Micro tensile bond strength of self-etching systems Contax, Futurabond NR and G Bond was comparable to the etch-and-rinse system PQ Clear. .
AB  - Cilj rada bio je da se odredi jačina veze dvofaznih i jednofaznih samonagrizajućih adhezivnih sistema sa dentinom. Površine dentina su eksponirane na 25 intaktnih trećih molara i zubi su podeljeni u 5 grupa (n=5). Izrađene su kompozitne nadogradnje korišćenjem sledećih samonagrizajućih adheziva / kompozitnih materijala: dvofazni samonagrizajući sistem Contax / Ecusphere Carat (DMG), dvofazni samonagrizajući sistem AdheSE / Tetric Ceram (Ivoclar Vivadent), jednofazni dvokomponentni samonagrizajući sistem Futurabond NR / Grandio (Voco) i jednofazni jednokomponentni samonagrizajući sistem G Bond / Gradia Direct (GC Corp.). Dvofazni adhezivni sistem sa potpunim nagrizanjem PQ Clear sa Amelogen Universal kompozitnim materijalom (Ultradent) korišćen je u kontrolnoj grupi. Jačina veze određena je testom otpornosti mikrouzoraka na kidanje. Rezultati su statistički analizirani jednofaktorskom analizom varijanse (ANOVA) i Tukey testom (p lt 0.05). Ispitivani samonagrizajući sistemi pokazali su zadovoljavajuće vrednosti jačine veze sa dentinom nakon 24 časa. Jačina veze dvofaznog samonagrizajućeg sistema AdheSE bila je značajno viša nego jačina veze u ostalim grupama (p lt 0.001). Jačine veze samonagrizajućih sistema Contax, Futurabond NR i G Bond nisu se statistički značajno razlikovale od jačine veze sistema sa potpunim nagrizanjem PQ Clear. .
PB  - Savez inženjera metalurgije Srbije, Beograd
T2  - Metalurgija
T1  - Microtensile bond strength of self-etching adhesives to dentin
VL  - 14
IS  - 2
SP  - 101
EP  - 109
UR  - https://hdl.handle.net/21.15107/rcub_smile_1404
ER  - 
@article{
author = "Vulićević, Zoran and Radović, Ivana and Krstanović, Goranka and Mandić, Jelena and Cury, Alvaro Hafiz and Ferrari, Marco",
year = "2008",
abstract = "The aim of this study was to determine micro tensile bond strength of two and one-step self-etching adhesive systems to dentin. 25 intact human third molars were used. Flat surfaces of mid-coronal dentin were exposed and the teeth were divided into 5 groups (n=5). Composite build-ups were made using the following self-etching systems / composite materials: 2-step self-etching system Contax / Ecusphere Carat (DMG), 2-step self-etching system AdheSE / Tetric Ceram (Ivoclar Vivadent), 1-step 2-components self etching system Futurabond NR / Grandio (Voco) and 1-step 1-component self-etching adhesive G Bond / Gradia Direct (GC Corp.). Two-step etch-and-rinse system PQ Clear with Amelogen Universal composite resin (Ultra dent) was used in the control group. Bond strength was assessed with the non-trimming micro tensile technique. Statistical analysis was performed using the 1-way ANOVA, followed by the Tukey test for post-hoc comparisons (p lt 0.05). Investigated self-etching systems showed satisfactory values of micro tensile bond strength to dentin after 24 hours. Two-step self-etching system AdheSE resulted in significantly higher bond strength than all the other groups (p lt 0.001). Micro tensile bond strength of self-etching systems Contax, Futurabond NR and G Bond was comparable to the etch-and-rinse system PQ Clear. ., Cilj rada bio je da se odredi jačina veze dvofaznih i jednofaznih samonagrizajućih adhezivnih sistema sa dentinom. Površine dentina su eksponirane na 25 intaktnih trećih molara i zubi su podeljeni u 5 grupa (n=5). Izrađene su kompozitne nadogradnje korišćenjem sledećih samonagrizajućih adheziva / kompozitnih materijala: dvofazni samonagrizajući sistem Contax / Ecusphere Carat (DMG), dvofazni samonagrizajući sistem AdheSE / Tetric Ceram (Ivoclar Vivadent), jednofazni dvokomponentni samonagrizajući sistem Futurabond NR / Grandio (Voco) i jednofazni jednokomponentni samonagrizajući sistem G Bond / Gradia Direct (GC Corp.). Dvofazni adhezivni sistem sa potpunim nagrizanjem PQ Clear sa Amelogen Universal kompozitnim materijalom (Ultradent) korišćen je u kontrolnoj grupi. Jačina veze određena je testom otpornosti mikrouzoraka na kidanje. Rezultati su statistički analizirani jednofaktorskom analizom varijanse (ANOVA) i Tukey testom (p lt 0.05). Ispitivani samonagrizajući sistemi pokazali su zadovoljavajuće vrednosti jačine veze sa dentinom nakon 24 časa. Jačina veze dvofaznog samonagrizajućeg sistema AdheSE bila je značajno viša nego jačina veze u ostalim grupama (p lt 0.001). Jačine veze samonagrizajućih sistema Contax, Futurabond NR i G Bond nisu se statistički značajno razlikovale od jačine veze sistema sa potpunim nagrizanjem PQ Clear. .",
publisher = "Savez inženjera metalurgije Srbije, Beograd",
journal = "Metalurgija",
title = "Microtensile bond strength of self-etching adhesives to dentin",
volume = "14",
number = "2",
pages = "101-109",
url = "https://hdl.handle.net/21.15107/rcub_smile_1404"
}
Vulićević, Z., Radović, I., Krstanović, G., Mandić, J., Cury, A. H.,& Ferrari, M.. (2008). Microtensile bond strength of self-etching adhesives to dentin. in Metalurgija
Savez inženjera metalurgije Srbije, Beograd., 14(2), 101-109.
https://hdl.handle.net/21.15107/rcub_smile_1404
Vulićević Z, Radović I, Krstanović G, Mandić J, Cury AH, Ferrari M. Microtensile bond strength of self-etching adhesives to dentin. in Metalurgija. 2008;14(2):101-109.
https://hdl.handle.net/21.15107/rcub_smile_1404 .
Vulićević, Zoran, Radović, Ivana, Krstanović, Goranka, Mandić, Jelena, Cury, Alvaro Hafiz, Ferrari, Marco, "Microtensile bond strength of self-etching adhesives to dentin" in Metalurgija, 14, no. 2 (2008):101-109,
https://hdl.handle.net/21.15107/rcub_smile_1404 .