Rašuo, Boško P.

Link to this page

Authority KeyName Variants
orcid::0000-0002-0912-6844
  • Rašuo, Boško P. (1)
Projects
No records found.

Author's Bibliography

Simulation of crack propagation in titanium mini dental implants (MDI)

Grbović, Aleksandar; Rašuo, Boško P.; Vidanović, Nenad D.; Perić, Mirjana

(Univerzitet u Beogradu - Mašinski fakultet, Beograd, 2011)

TY  - JOUR
AU  - Grbović, Aleksandar
AU  - Rašuo, Boško P.
AU  - Vidanović, Nenad D.
AU  - Perić, Mirjana
PY  - 2011
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1643
AB  - Developments in mini dental implants (MDI) manufacturing are aimed at making them more biocompatible and, at the same time, lighter, more durable and simultaneously safer than the existing implants. But, occasionally, during installation the failure of MDI may occur or cracks may appear, which could lead to the later failure of MDI. In order to understand and assess crack growth in titanium MDI, Finite Element (FE) software packages ANSYS v13 and FRANC3D v5 have been used. Using FRANC3D software different crack sizes and shapes have been modeled and simulations of crack propagations in three-dimensional model of MDI have been performed. Based on simulation results, the approximate fatigue life of damaged MDI was calculated.
AB  - Unapređenja u proizvodnji mini dentalnih implantata (MDI) su uglavnom usmerena ka povećanju njihove biokompatibilnosti i, u isto vreme, izdržljivosti i bezbednosti, ali i ka smanjenju njihovih dimenzija u odnosu na postojeće implantate. Međutim, tokom ugradnje MDI-a može doći do njegovog loma ili nastanka prsline koja kasnije može prouzrokovati lom. Da bi se analiziralo širenje prsline u titanijumskom MDI-u, korišćeni su softveri za primenu metode konačnih elemenata (MKE) ANSYS v13 i FRANC3D v5. Korišćenjem FRANC3D programa izmodelirane su prsline različitih veličina i oblika na 3D geometriji MDI-a i izvršeno je simuliranje njihovog širenja. Na osnovu rezultata simulacije izračunat je približan zamorni vek oštećenog MDI-a.
PB  - Univerzitet u Beogradu - Mašinski fakultet, Beograd
T2  - FME Transactions
T1  - Simulation of crack propagation in titanium mini dental implants (MDI)
T1  - Simulacija širenja prsline u titanijumskim mini dentalnim implantima (MDI)
VL  - 39
IS  - 4
SP  - 165
EP  - 170
UR  - https://hdl.handle.net/21.15107/rcub_smile_1643
ER  - 
@article{
author = "Grbović, Aleksandar and Rašuo, Boško P. and Vidanović, Nenad D. and Perić, Mirjana",
year = "2011",
abstract = "Developments in mini dental implants (MDI) manufacturing are aimed at making them more biocompatible and, at the same time, lighter, more durable and simultaneously safer than the existing implants. But, occasionally, during installation the failure of MDI may occur or cracks may appear, which could lead to the later failure of MDI. In order to understand and assess crack growth in titanium MDI, Finite Element (FE) software packages ANSYS v13 and FRANC3D v5 have been used. Using FRANC3D software different crack sizes and shapes have been modeled and simulations of crack propagations in three-dimensional model of MDI have been performed. Based on simulation results, the approximate fatigue life of damaged MDI was calculated., Unapređenja u proizvodnji mini dentalnih implantata (MDI) su uglavnom usmerena ka povećanju njihove biokompatibilnosti i, u isto vreme, izdržljivosti i bezbednosti, ali i ka smanjenju njihovih dimenzija u odnosu na postojeće implantate. Međutim, tokom ugradnje MDI-a može doći do njegovog loma ili nastanka prsline koja kasnije može prouzrokovati lom. Da bi se analiziralo širenje prsline u titanijumskom MDI-u, korišćeni su softveri za primenu metode konačnih elemenata (MKE) ANSYS v13 i FRANC3D v5. Korišćenjem FRANC3D programa izmodelirane su prsline različitih veličina i oblika na 3D geometriji MDI-a i izvršeno je simuliranje njihovog širenja. Na osnovu rezultata simulacije izračunat je približan zamorni vek oštećenog MDI-a.",
publisher = "Univerzitet u Beogradu - Mašinski fakultet, Beograd",
journal = "FME Transactions",
title = "Simulation of crack propagation in titanium mini dental implants (MDI), Simulacija širenja prsline u titanijumskim mini dentalnim implantima (MDI)",
volume = "39",
number = "4",
pages = "165-170",
url = "https://hdl.handle.net/21.15107/rcub_smile_1643"
}
Grbović, A., Rašuo, B. P., Vidanović, N. D.,& Perić, M.. (2011). Simulation of crack propagation in titanium mini dental implants (MDI). in FME Transactions
Univerzitet u Beogradu - Mašinski fakultet, Beograd., 39(4), 165-170.
https://hdl.handle.net/21.15107/rcub_smile_1643
Grbović A, Rašuo BP, Vidanović ND, Perić M. Simulation of crack propagation in titanium mini dental implants (MDI). in FME Transactions. 2011;39(4):165-170.
https://hdl.handle.net/21.15107/rcub_smile_1643 .
Grbović, Aleksandar, Rašuo, Boško P., Vidanović, Nenad D., Perić, Mirjana, "Simulation of crack propagation in titanium mini dental implants (MDI)" in FME Transactions, 39, no. 4 (2011):165-170,
https://hdl.handle.net/21.15107/rcub_smile_1643 .
22