Ministry of Science and Technological Development of the Republic of Serbia

Link to this page

Ministry of Science and Technological Development of the Republic of Serbia

Authors

Publications

Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns

Trifković, Branka; Budak, Igor; Todorović, A.; Hodolić, Janko; Puškar, Tatjana; Jevremović, Danimir; Vukelić, Đorđe

(Versita, Warsaw, 2012)

TY  - JOUR
AU  - Trifković, Branka
AU  - Budak, Igor
AU  - Todorović, A.
AU  - Hodolić, Janko
AU  - Puškar, Tatjana
AU  - Jevremović, Danimir
AU  - Vukelić, Đorđe
PY  - 2012
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1737
AB  - The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.
PB  - Versita, Warsaw
T2  - Measurement Science Review
T1  - Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns
VL  - 12
IS  - 3
SP  - 90
EP  - 97
DO  - 10.2478/v10048-012-0016-7
ER  - 
@article{
author = "Trifković, Branka and Budak, Igor and Todorović, A. and Hodolić, Janko and Puškar, Tatjana and Jevremović, Danimir and Vukelić, Đorđe",
year = "2012",
abstract = "The paper presents a comparative study of the measuring values of the marginal gap related to the ceramic crowns made by dental CAD/CAM system using the replica technique and SEM. The study was conducted using three experimental groups, which consisted of ceramic crowns manufactured by the Cerec CAD/CAM system. The scanning procedure was carried out using three specialized dental 3D digitization systems from the Cerec family - two types of extraoral optical scanning systems and an intraoral optical scanner. Measurements of the marginal gap were carried out using the replica technique and SEM. The comparison of aggregate values of the marginal gap using the replica technique showed a statistically significant difference between the systems. The measured values of marginal gaps of ceramic crowns using the replica technique were significantly lower compared to those measured by SEM. The results indicate that the choice of technique for measuring the accuracy of ceramic crowns influences the final results of investigation.",
publisher = "Versita, Warsaw",
journal = "Measurement Science Review",
title = "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns",
volume = "12",
number = "3",
pages = "90-97",
doi = "10.2478/v10048-012-0016-7"
}
Trifković, B., Budak, I., Todorović, A., Hodolić, J., Puškar, T., Jevremović, D.,& Vukelić, Đ.. (2012). Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review
Versita, Warsaw., 12(3), 90-97.
https://doi.org/10.2478/v10048-012-0016-7
Trifković B, Budak I, Todorović A, Hodolić J, Puškar T, Jevremović D, Vukelić Đ. Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns. in Measurement Science Review. 2012;12(3):90-97.
doi:10.2478/v10048-012-0016-7 .
Trifković, Branka, Budak, Igor, Todorović, A., Hodolić, Janko, Puškar, Tatjana, Jevremović, Danimir, Vukelić, Đorđe, "Application of Replica Technique and SEM in Accuracy Measurement of Ceramic Crowns" in Measurement Science Review, 12, no. 3 (2012):90-97,
https://doi.org/10.2478/v10048-012-0016-7 . .
21
11
25

Nanofoils for soldering and brazing in dental joining practice and jewellery manufacturing

Raić, Karlo T.; Rudolf, Rebeka; Kosec, Borut; Anžel, Ivan; Lazić, Vojkan; Todorović, Aleksandar

(Institute of Metals and Technology, 2010)

TY  - JOUR
AU  - Raić, Karlo T.
AU  - Rudolf, Rebeka
AU  - Kosec, Borut
AU  - Anžel, Ivan
AU  - Lazić, Vojkan
AU  - Todorović, Aleksandar
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1560
AB  - This paper describes the development of novel, reactive Al-Au nano-multilayered foils, their possible application in different fields and a discussion of the nano-foils' suitability for dental and jewellery applications. Moreover, this study includes the rapid joining of similar and dissimilar materials, by placing multilayer nano-foils and two layers of solder or braze. The foils precisely control the instantaneous release of heat energy for the joining and act as a controllable local heat source. The reactive foils' thickness is in the range 10 nm to less than 100 nm and they contain many nanoscale layers that alternate between materials with high mixing heats, such as Al and Au. The foil between the two solder/braze layers melts the solder/braze with the heat generated by the reaction and bonds the components. The use of reactive foils eliminates the need for a furnace and dramatically increases the soldering/brazing heating rate of the components being bonded. Thus, ceramics and metals can be fused over required areas without the thermal stresses that are encountered in furnace soldering or brazing. In addition, a completely new plasma technology is proposed for the manufacturing of nano-foils and the first results of the preliminary experimental testing are presented.
PB  - Institute of Metals and Technology
T2  - Materiali in Tehnologije
T1  - Nanofoils for soldering and brazing in dental joining practice and jewellery manufacturing
VL  - 43
IS  - 1
SP  - 3
EP  - 9
UR  - https://hdl.handle.net/21.15107/rcub_smile_1560
ER  - 
@article{
author = "Raić, Karlo T. and Rudolf, Rebeka and Kosec, Borut and Anžel, Ivan and Lazić, Vojkan and Todorović, Aleksandar",
year = "2010",
abstract = "This paper describes the development of novel, reactive Al-Au nano-multilayered foils, their possible application in different fields and a discussion of the nano-foils' suitability for dental and jewellery applications. Moreover, this study includes the rapid joining of similar and dissimilar materials, by placing multilayer nano-foils and two layers of solder or braze. The foils precisely control the instantaneous release of heat energy for the joining and act as a controllable local heat source. The reactive foils' thickness is in the range 10 nm to less than 100 nm and they contain many nanoscale layers that alternate between materials with high mixing heats, such as Al and Au. The foil between the two solder/braze layers melts the solder/braze with the heat generated by the reaction and bonds the components. The use of reactive foils eliminates the need for a furnace and dramatically increases the soldering/brazing heating rate of the components being bonded. Thus, ceramics and metals can be fused over required areas without the thermal stresses that are encountered in furnace soldering or brazing. In addition, a completely new plasma technology is proposed for the manufacturing of nano-foils and the first results of the preliminary experimental testing are presented.",
publisher = "Institute of Metals and Technology",
journal = "Materiali in Tehnologije",
title = "Nanofoils for soldering and brazing in dental joining practice and jewellery manufacturing",
volume = "43",
number = "1",
pages = "3-9",
url = "https://hdl.handle.net/21.15107/rcub_smile_1560"
}
Raić, K. T., Rudolf, R., Kosec, B., Anžel, I., Lazić, V.,& Todorović, A.. (2010). Nanofoils for soldering and brazing in dental joining practice and jewellery manufacturing. in Materiali in Tehnologije
Institute of Metals and Technology., 43(1), 3-9.
https://hdl.handle.net/21.15107/rcub_smile_1560
Raić KT, Rudolf R, Kosec B, Anžel I, Lazić V, Todorović A. Nanofoils for soldering and brazing in dental joining practice and jewellery manufacturing. in Materiali in Tehnologije. 2010;43(1):3-9.
https://hdl.handle.net/21.15107/rcub_smile_1560 .
Raić, Karlo T., Rudolf, Rebeka, Kosec, Borut, Anžel, Ivan, Lazić, Vojkan, Todorović, Aleksandar, "Nanofoils for soldering and brazing in dental joining practice and jewellery manufacturing" in Materiali in Tehnologije, 43, no. 1 (2010):3-9,
https://hdl.handle.net/21.15107/rcub_smile_1560 .
12
14

Relationship between microstructure, cytotoxicity and corrosion properties of a Cu-Al-Ni shape memory alloy

Čolić, Miodrag; Rudolf, Rebeka; Stamenković, Dragoslav; Anžel, Ivan; Vucević, Dragana; Jenko, Monika; Lazić, Vojkan; Lojen, Gorazd

(Elsevier Sci Ltd, Oxford, 2010)

TY  - JOUR
AU  - Čolić, Miodrag
AU  - Rudolf, Rebeka
AU  - Stamenković, Dragoslav
AU  - Anžel, Ivan
AU  - Vucević, Dragana
AU  - Jenko, Monika
AU  - Lazić, Vojkan
AU  - Lojen, Gorazd
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1553
AB  - Cu-Al-Ni shape memory alloys (SMAs) have been investigated as materials for medical devices, but their biomedical application is still limited. The aim of this work was to compare the microstructure, corrosion and cytotoxicity in vitro of a Cu-Al-Ni SMA. Rapidly solidified (RS) thin ribbons, manufactured via melt spinning, were used for the tests. The control alloy was a permanent mould casting of the same composition, but without shape memory effect. The results show that RS ribbons are significantly more resistant to corrosion compared with the control alloy, as judged by the lesser release of Cu and Ni into the conditioning medium. These results correlate with the finding that RS ribbons were not cytotoxic to L929 mouse fibroblasts and rat thymocytes. In addition, the RS ribbon conditioning medium inhibited cellular proliferation and IL-2 production by activated rat splenocytes to a much lesser extent. The inhibitory effects were almost completely abolished by conditioning the RS ribbons in culture medium for 4 weeks. Microstructural analysis showed that RS ribbons are martensitic, with boron particles as a minor phase. In contrast, the control Cu-Al-Ni alloy had a complex multiphase microstructure. Examination of the alloy surfaces after conditioning by energy dispersive X-ray and Auger electron spectroscopy showed the formation of Cu and Al oxide layers and confirmed that the metals in RS ribbons are less susceptible to oxidation and corrosion compared with the control alloy. In conclusion, these results suggest that rapid solidification significantly improves the corrosion stability and biocompatibility in vitro of Cu-Al-Ni SMA ribbons.
PB  - Elsevier Sci Ltd, Oxford
T2  - Acta Biomaterialia
T1  - Relationship between microstructure, cytotoxicity and corrosion properties of a Cu-Al-Ni shape memory alloy
VL  - 6
IS  - 1
SP  - 308
EP  - 317
DO  - 10.1016/j.actbio.2009.06.027
ER  - 
@article{
author = "Čolić, Miodrag and Rudolf, Rebeka and Stamenković, Dragoslav and Anžel, Ivan and Vucević, Dragana and Jenko, Monika and Lazić, Vojkan and Lojen, Gorazd",
year = "2010",
abstract = "Cu-Al-Ni shape memory alloys (SMAs) have been investigated as materials for medical devices, but their biomedical application is still limited. The aim of this work was to compare the microstructure, corrosion and cytotoxicity in vitro of a Cu-Al-Ni SMA. Rapidly solidified (RS) thin ribbons, manufactured via melt spinning, were used for the tests. The control alloy was a permanent mould casting of the same composition, but without shape memory effect. The results show that RS ribbons are significantly more resistant to corrosion compared with the control alloy, as judged by the lesser release of Cu and Ni into the conditioning medium. These results correlate with the finding that RS ribbons were not cytotoxic to L929 mouse fibroblasts and rat thymocytes. In addition, the RS ribbon conditioning medium inhibited cellular proliferation and IL-2 production by activated rat splenocytes to a much lesser extent. The inhibitory effects were almost completely abolished by conditioning the RS ribbons in culture medium for 4 weeks. Microstructural analysis showed that RS ribbons are martensitic, with boron particles as a minor phase. In contrast, the control Cu-Al-Ni alloy had a complex multiphase microstructure. Examination of the alloy surfaces after conditioning by energy dispersive X-ray and Auger electron spectroscopy showed the formation of Cu and Al oxide layers and confirmed that the metals in RS ribbons are less susceptible to oxidation and corrosion compared with the control alloy. In conclusion, these results suggest that rapid solidification significantly improves the corrosion stability and biocompatibility in vitro of Cu-Al-Ni SMA ribbons.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Acta Biomaterialia",
title = "Relationship between microstructure, cytotoxicity and corrosion properties of a Cu-Al-Ni shape memory alloy",
volume = "6",
number = "1",
pages = "308-317",
doi = "10.1016/j.actbio.2009.06.027"
}
Čolić, M., Rudolf, R., Stamenković, D., Anžel, I., Vucević, D., Jenko, M., Lazić, V.,& Lojen, G.. (2010). Relationship between microstructure, cytotoxicity and corrosion properties of a Cu-Al-Ni shape memory alloy. in Acta Biomaterialia
Elsevier Sci Ltd, Oxford., 6(1), 308-317.
https://doi.org/10.1016/j.actbio.2009.06.027
Čolić M, Rudolf R, Stamenković D, Anžel I, Vucević D, Jenko M, Lazić V, Lojen G. Relationship between microstructure, cytotoxicity and corrosion properties of a Cu-Al-Ni shape memory alloy. in Acta Biomaterialia. 2010;6(1):308-317.
doi:10.1016/j.actbio.2009.06.027 .
Čolić, Miodrag, Rudolf, Rebeka, Stamenković, Dragoslav, Anžel, Ivan, Vucević, Dragana, Jenko, Monika, Lazić, Vojkan, Lojen, Gorazd, "Relationship between microstructure, cytotoxicity and corrosion properties of a Cu-Al-Ni shape memory alloy" in Acta Biomaterialia, 6, no. 1 (2010):308-317,
https://doi.org/10.1016/j.actbio.2009.06.027 . .
47
37
51

Liquid metal/ceramic interfaces in dental practice and jewellery manufacturing

Raić, Karlo T.; Rudolf, Rebeka; Todorović, Aleksandar; Stamenković, Dragoslav; Anžel, Ivan

(Institute of Metals and Technology, 2010)

TY  - JOUR
AU  - Raić, Karlo T.
AU  - Rudolf, Rebeka
AU  - Todorović, Aleksandar
AU  - Stamenković, Dragoslav
AU  - Anžel, Ivan
PY  - 2010
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1534
AB  - Metal-ceramic fusing has been the essential step in obtaining materials that benefit from both ceramic and metal constituents. i e where the combined properties of metal and ceramic layers are desirable When considering fusing methods. soldering and active metal brazing are the most effective These processes involve braze melting and flowing between the two pieces of material In the first part the phenomena occurring on the boundary between the ceramics and the active filler metal during the metal-ceramics joining are discussed Three interconnected sub-processes are considered (1) wetting of the ceramic surface. (2) chemical reactions at the Interlace and (3) diffusion with a moving interface Then, the appearances at the grain boundary grooves of the ceramic surface are presented as phenomena on the catalytic surface In the second pan, examples from dental practice and jewellery manufacturing are used for comparative analysis Finally we discuss the composition and properties of the soldering and brazing alloys used for dental practice and jewellery manufacturing
PB  - Institute of Metals and Technology
T2  - Materiali in Tehnologije
T1  - Liquid metal/ceramic interfaces in dental practice and jewellery manufacturing
VL  - 44
IS  - 2
SP  - 59
EP  - 66
UR  - https://hdl.handle.net/21.15107/rcub_smile_1534
ER  - 
@article{
author = "Raić, Karlo T. and Rudolf, Rebeka and Todorović, Aleksandar and Stamenković, Dragoslav and Anžel, Ivan",
year = "2010",
abstract = "Metal-ceramic fusing has been the essential step in obtaining materials that benefit from both ceramic and metal constituents. i e where the combined properties of metal and ceramic layers are desirable When considering fusing methods. soldering and active metal brazing are the most effective These processes involve braze melting and flowing between the two pieces of material In the first part the phenomena occurring on the boundary between the ceramics and the active filler metal during the metal-ceramics joining are discussed Three interconnected sub-processes are considered (1) wetting of the ceramic surface. (2) chemical reactions at the Interlace and (3) diffusion with a moving interface Then, the appearances at the grain boundary grooves of the ceramic surface are presented as phenomena on the catalytic surface In the second pan, examples from dental practice and jewellery manufacturing are used for comparative analysis Finally we discuss the composition and properties of the soldering and brazing alloys used for dental practice and jewellery manufacturing",
publisher = "Institute of Metals and Technology",
journal = "Materiali in Tehnologije",
title = "Liquid metal/ceramic interfaces in dental practice and jewellery manufacturing",
volume = "44",
number = "2",
pages = "59-66",
url = "https://hdl.handle.net/21.15107/rcub_smile_1534"
}
Raić, K. T., Rudolf, R., Todorović, A., Stamenković, D.,& Anžel, I.. (2010). Liquid metal/ceramic interfaces in dental practice and jewellery manufacturing. in Materiali in Tehnologije
Institute of Metals and Technology., 44(2), 59-66.
https://hdl.handle.net/21.15107/rcub_smile_1534
Raić KT, Rudolf R, Todorović A, Stamenković D, Anžel I. Liquid metal/ceramic interfaces in dental practice and jewellery manufacturing. in Materiali in Tehnologije. 2010;44(2):59-66.
https://hdl.handle.net/21.15107/rcub_smile_1534 .
Raić, Karlo T., Rudolf, Rebeka, Todorović, Aleksandar, Stamenković, Dragoslav, Anžel, Ivan, "Liquid metal/ceramic interfaces in dental practice and jewellery manufacturing" in Materiali in Tehnologije, 44, no. 2 (2010):59-66,
https://hdl.handle.net/21.15107/rcub_smile_1534 .
4
5