T-scan II occlusal analysis in restorative dentistry
Analiza okluzalnih kontakata T-scan II sistemom u restaurativnoj stomatologiji
Апстракт
The comparison of accufilm markings and computerized T-Scan II force plots of restorations and occlusal interferences in intercuspal position of the lower jaw, before and after occlusal adjustment showed a great improvement in force distribution, balance of occlusal forces and evenness of the right and left side. The computer analysis through T-Scan II system help us to clearly understand what those well balanced occlusal contacts and force distribution really mean for the proper restorative occlusal therapy.
Analiza okluzije primenom okluzalnih indikatora ili kompjutera predstavlja sastavni deo savremene kliničke funkcijske analize. Cilj ovog rada bio je da se prikaže primena kompjuterskog T-Scan II sistema u okluzalnoj terapiji restaurativnim ispunima. T-Scan II kompjuterska analiza okluzije posle okluzalne terapije restaurativnim ispunima omogućuje registivanje broja kontakata, površinu, vreme njihovog trajanja, odnosno ukupno okluzalno opterećenje i raspored sila u odnosu na aproksimativno područje sumiranja rezultanti okluzalnih sila u završnom Ikp mandibule. Kompjuterska analiza pruža podatke o uravnoteženosti ili neuravnoteženosti okluzije što predstavlja važan podatak za pravilan tok i ishod okluzalne terapije restaurativnim ispunima.
Кључне речи:
restoration / occlusion / occlusal indikators / T-Scan II / restaurativni ispun / okluzija / okluzalni indikatori / T-Scan IIИзвор:
Stomatološki glasnik Srbije, 2002, 49, 3-4, 110-113Издавач:
- Srpsko lekarsko društvo - Stomatološka sekcija, Beograd
Колекције
Институција/група
Stomatološki fakultetTY - JOUR AU - Lazić, Vojkan AU - Živković, Slavoljub PY - 2002 UR - https://smile.stomf.bg.ac.rs/handle/123456789/1148 AB - The comparison of accufilm markings and computerized T-Scan II force plots of restorations and occlusal interferences in intercuspal position of the lower jaw, before and after occlusal adjustment showed a great improvement in force distribution, balance of occlusal forces and evenness of the right and left side. The computer analysis through T-Scan II system help us to clearly understand what those well balanced occlusal contacts and force distribution really mean for the proper restorative occlusal therapy. AB - Analiza okluzije primenom okluzalnih indikatora ili kompjutera predstavlja sastavni deo savremene kliničke funkcijske analize. Cilj ovog rada bio je da se prikaže primena kompjuterskog T-Scan II sistema u okluzalnoj terapiji restaurativnim ispunima. T-Scan II kompjuterska analiza okluzije posle okluzalne terapije restaurativnim ispunima omogućuje registivanje broja kontakata, površinu, vreme njihovog trajanja, odnosno ukupno okluzalno opterećenje i raspored sila u odnosu na aproksimativno područje sumiranja rezultanti okluzalnih sila u završnom Ikp mandibule. Kompjuterska analiza pruža podatke o uravnoteženosti ili neuravnoteženosti okluzije što predstavlja važan podatak za pravilan tok i ishod okluzalne terapije restaurativnim ispunima. PB - Srpsko lekarsko društvo - Stomatološka sekcija, Beograd T2 - Stomatološki glasnik Srbije T1 - T-scan II occlusal analysis in restorative dentistry T1 - Analiza okluzalnih kontakata T-scan II sistemom u restaurativnoj stomatologiji VL - 49 IS - 3-4 SP - 110 EP - 113 DO - 10.2298/SGS0204110L ER -
@article{ author = "Lazić, Vojkan and Živković, Slavoljub", year = "2002", abstract = "The comparison of accufilm markings and computerized T-Scan II force plots of restorations and occlusal interferences in intercuspal position of the lower jaw, before and after occlusal adjustment showed a great improvement in force distribution, balance of occlusal forces and evenness of the right and left side. The computer analysis through T-Scan II system help us to clearly understand what those well balanced occlusal contacts and force distribution really mean for the proper restorative occlusal therapy., Analiza okluzije primenom okluzalnih indikatora ili kompjutera predstavlja sastavni deo savremene kliničke funkcijske analize. Cilj ovog rada bio je da se prikaže primena kompjuterskog T-Scan II sistema u okluzalnoj terapiji restaurativnim ispunima. T-Scan II kompjuterska analiza okluzije posle okluzalne terapije restaurativnim ispunima omogućuje registivanje broja kontakata, površinu, vreme njihovog trajanja, odnosno ukupno okluzalno opterećenje i raspored sila u odnosu na aproksimativno područje sumiranja rezultanti okluzalnih sila u završnom Ikp mandibule. Kompjuterska analiza pruža podatke o uravnoteženosti ili neuravnoteženosti okluzije što predstavlja važan podatak za pravilan tok i ishod okluzalne terapije restaurativnim ispunima.", publisher = "Srpsko lekarsko društvo - Stomatološka sekcija, Beograd", journal = "Stomatološki glasnik Srbije", title = "T-scan II occlusal analysis in restorative dentistry, Analiza okluzalnih kontakata T-scan II sistemom u restaurativnoj stomatologiji", volume = "49", number = "3-4", pages = "110-113", doi = "10.2298/SGS0204110L" }
Lazić, V.,& Živković, S.. (2002). T-scan II occlusal analysis in restorative dentistry. in Stomatološki glasnik Srbije Srpsko lekarsko društvo - Stomatološka sekcija, Beograd., 49(3-4), 110-113. https://doi.org/10.2298/SGS0204110L
Lazić V, Živković S. T-scan II occlusal analysis in restorative dentistry. in Stomatološki glasnik Srbije. 2002;49(3-4):110-113. doi:10.2298/SGS0204110L .
Lazić, Vojkan, Živković, Slavoljub, "T-scan II occlusal analysis in restorative dentistry" in Stomatološki glasnik Srbije, 49, no. 3-4 (2002):110-113, https://doi.org/10.2298/SGS0204110L . .