Приказ основних података о документу
T-Scan II computerized occlusal analysis
Kompjuterska analiza okluzije T-Scan II sistemom
dc.creator | Lazić, Vojkan | |
dc.creator | Živković, Slavoljub | |
dc.creator | Popović, Gorjana | |
dc.date.accessioned | 2020-07-02T12:06:50Z | |
dc.date.available | 2020-07-02T12:06:50Z | |
dc.date.issued | 2004 | |
dc.identifier.issn | 0039-1743 | |
dc.identifier.uri | https://smile.stomf.bg.ac.rs/handle/123456789/1226 | |
dc.description.abstract | Occlusal analysis using computerized technology has become a part of modern information technology. The aim of this study was to show the possibilities of T-Scan II computerized occlusal analyzer in prosthetic and restorative postinsertion occlusal problems. The T-Scan II computerized occlusal analysis (Tekscan, Boston, USA) is an integral part of clinical functional analyses in prosthetic and restorative insertions. The T-Scan II computerized system can quickly determine prematurities, high points, regions of excessive force and nonuniform force concentration. It can also calculate disocclusion time accurately. Occlusal foil indicators can determine only the position, number and relative force of occlusal contacts. | en |
dc.description.abstract | Analiza okluzije primenom okluzalnih indikatora ili kompjutera predstavlja sastavni deo savremene kliničke funkcijske analize. Cilj ovog rada bio je da se prikaže mogućnost kompjuterskog T-Scan sistema u analizi okluzije. Nova generacija T-Scan sistema (T-Scan II, Tekscan, USA) za kompjutersku analizu okluzije pre i posle okluzalne terapije restaurativnim ispunima ili zubnim nadoknadama omogućuje veoma precizno registrovanje broja kontakata, površinu, vreme njihovog trajanja, odnosno ukupno okluzalno opterećenje i raspored sila u odnosu na aproksimativno područje sumiranja rezultanti okluzalnih sila u završnom interkuspalnom položaju (Ikp) mandibule. Kompjuterska analiza pruža podatke o uravnoteženosti ili neuravnoteženosti okluzije odnosno registruje i intenzitet okluzalnih kontakata kao I distribuciju okluzalnih sila što predstavlja važan podatak za pravilan tok i ishod okluzalne terapije. | sr |
dc.publisher | Srpsko lekarsko društvo - Stomatološka sekcija, Beograd | |
dc.rights | openAccess | |
dc.rights.uri | https://creativecommons.org/licenses/by-sa/4.0/ | |
dc.source | Stomatološki glasnik Srbije | |
dc.subject | occlusion | en |
dc.subject | occlusal therapy | en |
dc.subject | occlusal indicators | en |
dc.subject | T-Scan II | en |
dc.subject | okluzija | sr |
dc.subject | okluzalna terapija | sr |
dc.subject | okluzalni indikatori | sr |
dc.subject | T-Scan II | sr |
dc.title | T-Scan II computerized occlusal analysis | en |
dc.title | Kompjuterska analiza okluzije T-Scan II sistemom | sr |
dc.type | article | |
dc.rights.license | BY-SA | |
dcterms.abstract | Живковић, Славољуб; Лазић, Војкан; Поповић, Горјана; Компјутерска анализа оклузије Т-Сцан ИИ системом; Компјутерска анализа оклузије Т-Сцан ИИ системом; | |
dc.citation.volume | 51 | |
dc.citation.issue | 1 | |
dc.citation.spage | 24 | |
dc.citation.epage | 29 | |
dc.citation.other | 51(1): 24-29 | |
dc.identifier.doi | 10.2298/SGS0401024L | |
dc.identifier.fulltext | https://smile.stomf.bg.ac.rs/bitstream/id/104/1221.pdf | |
dc.type.version | publishedVersion |