The influence of operator variability on adhesive cementation of fiber posts

No Thumbnail
Authors
Simonetti, Marco
Radović, Ivana
Vano, Michele
Chieffi, Nicoleita
Goracci, Cecilia
Tognini, Francesco
Ferrari, Marco
Article (Published version)
Metadata
Show full item record
Abstract
Purpose: The aim of this study was to evaluate the influence of the operator's experience on the outcome of fiber post cementation using an etch-and-rinse acetone-based adhesive. Materials and Methods: Fifteen human anterior teeth were used in the study. One trained operator performed the endodontic procedures and prepared the roots for the insertion and cementation of the posts. At this point, teeth were divided into 3 groups and distributed to 3 operators to lute the posts: an expert operator (EO), a moderately experienced operator (ME), and an operator with a low level of experience (LE). Quartz fiber posts (DT Light Post #1 or #2, RTD) were used. Posts were cemented using Prime&Bond NT Dual Cure adhesive system (Dentsply Caulk) in combination with the dual-curing resin cement Calibra (Dentsply Caulk). The post retention was assessed with the "thin-slice" push-out test. One-way ANOVA was performed to examine the effect of the operator on push-out strength, followed by post-hoc multi...ple comparisons using Tukey's test, with the significance level set at alpha = 95%. Results: The results of push-out strength testing were as follows: EO (12.44 +/- 3.63 MPa), ME (11.68 +/- 2.64 MPa), LE (11.18 +/- 3.12 MPa). No statistically significant differences were determined among the three groups. Conclusion: There was no statistically significant difference in the retention measured for fiber posts luted by operators with different levels of clinical experience. Given the parameters of this investigation, the level of operator experience in luting fiber posts does not affect post retention under laboratory conditions.

Keywords:
operator / variability / bonding / fiber posts
Source:
Journal of Adhesive Dentistry, 2006, 8, 6, 421-425
Publisher:
  • Quintessence Publishing Co. Inc.

ISSN: 1461-5185

PubMed: 17243600

WoS: 000242915800010

Scopus: 2-s2.0-33846011419
[ Google Scholar ]
10
9
Handle
https://hdl.handle.net/21.15107/rcub_smile_1303
URI
https://smile.stomf.bg.ac.rs/handle/123456789/1303
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Simonetti, Marco
AU  - Radović, Ivana
AU  - Vano, Michele
AU  - Chieffi, Nicoleita
AU  - Goracci, Cecilia
AU  - Tognini, Francesco
AU  - Ferrari, Marco
PY  - 2006
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1303
AB  - Purpose: The aim of this study was to evaluate the influence of the operator's experience on the outcome of fiber post cementation using an etch-and-rinse acetone-based adhesive. Materials and Methods: Fifteen human anterior teeth were used in the study. One trained operator performed the endodontic procedures and prepared the roots for the insertion and cementation of the posts. At this point, teeth were divided into 3 groups and distributed to 3 operators to lute the posts: an expert operator (EO), a moderately experienced operator (ME), and an operator with a low level of experience (LE). Quartz fiber posts (DT Light Post #1 or #2, RTD) were used. Posts were cemented using Prime&Bond NT Dual Cure adhesive system (Dentsply Caulk) in combination with the dual-curing resin cement Calibra (Dentsply Caulk). The post retention was assessed with the "thin-slice" push-out test. One-way ANOVA was performed to examine the effect of the operator on push-out strength, followed by post-hoc multiple comparisons using Tukey's test, with the significance level set at alpha = 95%. Results: The results of push-out strength testing were as follows: EO (12.44 +/- 3.63 MPa), ME (11.68 +/- 2.64 MPa), LE (11.18 +/- 3.12 MPa). No statistically significant differences were determined among the three groups. Conclusion: There was no statistically significant difference in the retention measured for fiber posts luted by operators with different levels of clinical experience. Given the parameters of this investigation, the level of operator experience in luting fiber posts does not affect post retention under laboratory conditions.
PB  - Quintessence Publishing Co. Inc.
T2  - Journal of Adhesive Dentistry
T1  - The influence of operator variability on adhesive cementation of fiber posts
VL  - 8
IS  - 6
SP  - 421
EP  - 425
UR  - https://hdl.handle.net/21.15107/rcub_smile_1303
ER  - 
@article{
author = "Simonetti, Marco and Radović, Ivana and Vano, Michele and Chieffi, Nicoleita and Goracci, Cecilia and Tognini, Francesco and Ferrari, Marco",
year = "2006",
abstract = "Purpose: The aim of this study was to evaluate the influence of the operator's experience on the outcome of fiber post cementation using an etch-and-rinse acetone-based adhesive. Materials and Methods: Fifteen human anterior teeth were used in the study. One trained operator performed the endodontic procedures and prepared the roots for the insertion and cementation of the posts. At this point, teeth were divided into 3 groups and distributed to 3 operators to lute the posts: an expert operator (EO), a moderately experienced operator (ME), and an operator with a low level of experience (LE). Quartz fiber posts (DT Light Post #1 or #2, RTD) were used. Posts were cemented using Prime&Bond NT Dual Cure adhesive system (Dentsply Caulk) in combination with the dual-curing resin cement Calibra (Dentsply Caulk). The post retention was assessed with the "thin-slice" push-out test. One-way ANOVA was performed to examine the effect of the operator on push-out strength, followed by post-hoc multiple comparisons using Tukey's test, with the significance level set at alpha = 95%. Results: The results of push-out strength testing were as follows: EO (12.44 +/- 3.63 MPa), ME (11.68 +/- 2.64 MPa), LE (11.18 +/- 3.12 MPa). No statistically significant differences were determined among the three groups. Conclusion: There was no statistically significant difference in the retention measured for fiber posts luted by operators with different levels of clinical experience. Given the parameters of this investigation, the level of operator experience in luting fiber posts does not affect post retention under laboratory conditions.",
publisher = "Quintessence Publishing Co. Inc.",
journal = "Journal of Adhesive Dentistry",
title = "The influence of operator variability on adhesive cementation of fiber posts",
volume = "8",
number = "6",
pages = "421-425",
url = "https://hdl.handle.net/21.15107/rcub_smile_1303"
}
Simonetti, M., Radović, I., Vano, M., Chieffi, N., Goracci, C., Tognini, F.,& Ferrari, M.. (2006). The influence of operator variability on adhesive cementation of fiber posts. in Journal of Adhesive Dentistry
Quintessence Publishing Co. Inc.., 8(6), 421-425.
https://hdl.handle.net/21.15107/rcub_smile_1303
Simonetti M, Radović I, Vano M, Chieffi N, Goracci C, Tognini F, Ferrari M. The influence of operator variability on adhesive cementation of fiber posts. in Journal of Adhesive Dentistry. 2006;8(6):421-425.
https://hdl.handle.net/21.15107/rcub_smile_1303 .
Simonetti, Marco, Radović, Ivana, Vano, Michele, Chieffi, Nicoleita, Goracci, Cecilia, Tognini, Francesco, Ferrari, Marco, "The influence of operator variability on adhesive cementation of fiber posts" in Journal of Adhesive Dentistry, 8, no. 6 (2006):421-425,
https://hdl.handle.net/21.15107/rcub_smile_1303 .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB