Morphological evaluation of 2-and 1-step self-etching system interfaces with dentin
Samo za registrovane korisnike
2006
Članak u časopisu (Objavljena verzija)

Metapodaci
Prikaz svih podataka o dokumentuApstrakt
This in vitro study evaluated the resin-dentin interface formed by two 2-step and two 1-step self-etching adhesive systems under SEM. Class V cavities (4 x 2.5 x 1.5 mm) were prepared on the buccal surfaces of 25 extracted intact human third molars using a carbide bur in a high-speed handpiece. Four self-etching systems with corresponding resins were used: two 2-step systems, AdheSE (Ivoclar Vivadent) and Contax (DMG Hamburg), one 1-step/2 components system Futurabond NR (Voco) and a 1-step/1 component adhesive G-Bond (GC Corp). An etch and rinse system, PQ Clear (Ultradent), was used as a control. The teeth were thermocycled (500 cycles, 5 degrees/55 degrees C, 30 seconds dwell time), and 2 sections were made longitudinally through the restorations with a low-speed diamond saw, producing approximately 1-mm wide samples. The samples were polished with silicon carbide paper of increasing grit (400-1000), demineralized (6N HCl, 30 seconds), deproteinized (2.5% NaOCl, 10 minutes), left to... air dry for 24 hours in a desiccator under low vacuum pressure, gold sputtered and viewed under SEM (JEOL-JSM-646OLV). In the AdheSE, Contax and Futurabond NR specimens, resin tag penetration into the tubules and lateral tags could be seen. G-Bond showed different interface morphology, with a tight, thin continuous junction and almost no resin penetration into tubules. PQ Clear samples exhibited the highest number of resin tags with numerous lateral tags. A clearly defined hybrid layer was seen in the Contax and PQ Clear specimens. Investigated self-etching systems showed similar interfacial morphology with dentin, except for the 1 step/1 component adhesive G-Bond. The degree of demineralization and interaction with dentin correlated with the acidity of the self-etching primers/adhesives. Fewer resin tags were formed with self-etching primers/adhesives than with the etch and rinse system.
Izvor:
Operative Dentistry, 2006, 31, 6, 710-718Izdavač:
- Operative Dentistry Inc, Indianapolis
DOI: 10.2341/05-145
ISSN: 0361-7734
PubMed: 17153982
WoS: 000242051300013
Scopus: 2-s2.0-33845351751
Kolekcije
Institucija/grupa
Stomatološki fakultetTY - JOUR AU - Radović, I. AU - Vulićević, Zoran AU - Garcia-Godoy, Franklin PY - 2006 UR - https://smile.stomf.bg.ac.rs/handle/123456789/1317 AB - This in vitro study evaluated the resin-dentin interface formed by two 2-step and two 1-step self-etching adhesive systems under SEM. Class V cavities (4 x 2.5 x 1.5 mm) were prepared on the buccal surfaces of 25 extracted intact human third molars using a carbide bur in a high-speed handpiece. Four self-etching systems with corresponding resins were used: two 2-step systems, AdheSE (Ivoclar Vivadent) and Contax (DMG Hamburg), one 1-step/2 components system Futurabond NR (Voco) and a 1-step/1 component adhesive G-Bond (GC Corp). An etch and rinse system, PQ Clear (Ultradent), was used as a control. The teeth were thermocycled (500 cycles, 5 degrees/55 degrees C, 30 seconds dwell time), and 2 sections were made longitudinally through the restorations with a low-speed diamond saw, producing approximately 1-mm wide samples. The samples were polished with silicon carbide paper of increasing grit (400-1000), demineralized (6N HCl, 30 seconds), deproteinized (2.5% NaOCl, 10 minutes), left to air dry for 24 hours in a desiccator under low vacuum pressure, gold sputtered and viewed under SEM (JEOL-JSM-646OLV). In the AdheSE, Contax and Futurabond NR specimens, resin tag penetration into the tubules and lateral tags could be seen. G-Bond showed different interface morphology, with a tight, thin continuous junction and almost no resin penetration into tubules. PQ Clear samples exhibited the highest number of resin tags with numerous lateral tags. A clearly defined hybrid layer was seen in the Contax and PQ Clear specimens. Investigated self-etching systems showed similar interfacial morphology with dentin, except for the 1 step/1 component adhesive G-Bond. The degree of demineralization and interaction with dentin correlated with the acidity of the self-etching primers/adhesives. Fewer resin tags were formed with self-etching primers/adhesives than with the etch and rinse system. PB - Operative Dentistry Inc, Indianapolis T2 - Operative Dentistry T1 - Morphological evaluation of 2-and 1-step self-etching system interfaces with dentin VL - 31 IS - 6 SP - 710 EP - 718 DO - 10.2341/05-145 ER -
@article{ author = "Radović, I. and Vulićević, Zoran and Garcia-Godoy, Franklin", year = "2006", abstract = "This in vitro study evaluated the resin-dentin interface formed by two 2-step and two 1-step self-etching adhesive systems under SEM. Class V cavities (4 x 2.5 x 1.5 mm) were prepared on the buccal surfaces of 25 extracted intact human third molars using a carbide bur in a high-speed handpiece. Four self-etching systems with corresponding resins were used: two 2-step systems, AdheSE (Ivoclar Vivadent) and Contax (DMG Hamburg), one 1-step/2 components system Futurabond NR (Voco) and a 1-step/1 component adhesive G-Bond (GC Corp). An etch and rinse system, PQ Clear (Ultradent), was used as a control. The teeth were thermocycled (500 cycles, 5 degrees/55 degrees C, 30 seconds dwell time), and 2 sections were made longitudinally through the restorations with a low-speed diamond saw, producing approximately 1-mm wide samples. The samples were polished with silicon carbide paper of increasing grit (400-1000), demineralized (6N HCl, 30 seconds), deproteinized (2.5% NaOCl, 10 minutes), left to air dry for 24 hours in a desiccator under low vacuum pressure, gold sputtered and viewed under SEM (JEOL-JSM-646OLV). In the AdheSE, Contax and Futurabond NR specimens, resin tag penetration into the tubules and lateral tags could be seen. G-Bond showed different interface morphology, with a tight, thin continuous junction and almost no resin penetration into tubules. PQ Clear samples exhibited the highest number of resin tags with numerous lateral tags. A clearly defined hybrid layer was seen in the Contax and PQ Clear specimens. Investigated self-etching systems showed similar interfacial morphology with dentin, except for the 1 step/1 component adhesive G-Bond. The degree of demineralization and interaction with dentin correlated with the acidity of the self-etching primers/adhesives. Fewer resin tags were formed with self-etching primers/adhesives than with the etch and rinse system.", publisher = "Operative Dentistry Inc, Indianapolis", journal = "Operative Dentistry", title = "Morphological evaluation of 2-and 1-step self-etching system interfaces with dentin", volume = "31", number = "6", pages = "710-718", doi = "10.2341/05-145" }
Radović, I., Vulićević, Z.,& Garcia-Godoy, F.. (2006). Morphological evaluation of 2-and 1-step self-etching system interfaces with dentin. in Operative Dentistry Operative Dentistry Inc, Indianapolis., 31(6), 710-718. https://doi.org/10.2341/05-145
Radović I, Vulićević Z, Garcia-Godoy F. Morphological evaluation of 2-and 1-step self-etching system interfaces with dentin. in Operative Dentistry. 2006;31(6):710-718. doi:10.2341/05-145 .
Radović, I., Vulićević, Zoran, Garcia-Godoy, Franklin, "Morphological evaluation of 2-and 1-step self-etching system interfaces with dentin" in Operative Dentistry, 31, no. 6 (2006):710-718, https://doi.org/10.2341/05-145 . .