Приказ основних података о документу

dc.creatorPapacchini, Federica
dc.creatorRadović, Ivana
dc.creatorMagni, Elisa
dc.creatorGoracci, Cecilia
dc.creatorMonticelli, Francesca
dc.creatorChieffi, Nicoletta
dc.creatorPolimeni, Antonella
dc.creatorFerrari, Marco
dc.date.accessioned2020-07-02T12:17:57Z
dc.date.available2020-07-02T12:17:57Z
dc.date.issued2008
dc.identifier.issn0894-8275
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1396
dc.description.abstractPurpose: To evaluate the effect of different intermediate resin agents on composite-to-composite microtensile bond strength (mu TBS). Methods: Composite disks (8 x 4 mm) of Gradia Direct Anterior (N= 15) and Filtek Supreme XT (N=15), stored in a saline solution at 37 degrees C for I month, were sandblasted (Microetcher, 50 mu m-Al2O3), cleaned (35% H3PO4), and randomly divided into five groups (N=3) according to the intermediate agent applied. Two flowable composites (Gradia LoFlo; Filtek Supreme XT Flow) and two adhesives (Adper Scotchbond 1XT, Scotchbond Multi-Purpose) were used. As a control, no intermediate agent was applied., Each disk was incrementally repaired (W mm) with the same resin as the respective substrate. By serially cutting each repaired specimen, multiple sticks of about 0.8 mm(2) in cross-section were obtained and loaded in tension until failure at a cross-head speed of 0.5 mm/minute. Data were statistically analyzed. Failure mode was examined by stereo- and scanning electron-microscopy (SEM). Additional specimens were prepared to morphologically evaluate the composite-to-composite interfacial quality by SEM analysis. Results: Composite substrate and intermediate agent were significant factors (Two-way ANOVA, P lt 0.001). Bond strengths achieved with Gradia Direct Anterior were higher than Hick Supreme XT. The application of flowable composites resulted in statistically superior mu TBS than adhesives and control (Tukey test, P lt 0.001). Failure mode was predominantly cohesive (flowable composites), cohesive/adhesive (adhesives) and adhesive (no treatment). Flowable composites and adhesives showed a good interfacial quality.en
dc.publisherMosher and Linder, Inc
dc.rightsrestrictedAccess
dc.sourceAmerican Journal of Dentistry
dc.titleFlowable composites as intermediate agents without adhesive application in resin composite repairen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractПолимени, Aнтонелла; Папаццхини, Федерица; Радовић, Ивана; Магни, Елиса; Феррари, Марцо; Монтицелли, Францесца; Горацци, Цецилиа; Цхиеффи, Ницолетта;
dc.citation.volume21
dc.citation.issue1
dc.citation.spage53
dc.citation.epage58
dc.citation.other21(1): 53-58
dc.citation.rankM23
dc.identifier.wos000253927000012
dc.identifier.scopus2-s2.0-41549157819
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_smile_1396
dc.type.versionpublishedVersion


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу