SMILE – Repository of the Faculty of Dental Medicine
University of Belgrade - Faculty of Dental Medicine
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Remaining Unreacted Methacrylate Groups in Resin-Based Composite With Respect to Sample Preparation and Storing Conditions Using Micro-Raman Spectroscopy

Authorized Users Only
2008
Authors
Miletić, Vesna
Santini, Ario
Article (Published version)
Metadata
Show full item record
Abstract
The aim of this study was to measure degree of conversion (DC) of resin-based composites (RBCs) using micro-Raman spectroscopy followed by different sample preparation procedures and storing conditions. Ninety samples of Tetric EvoCeram (Ivoclar Vivadent, Schaan, Liechtenstein) were prepared in standardized molds and cured with a high powered LED light-curing unit, bluephase (R)) (Ivoclar Vivadent, Schaan, Liechtenstein) for 20 s. Samples were allocated to eight groups. DC of groups I and 2 was recorded without or after polishing. DC in groups 3 and 4 was recorded from vertically sectioned samples versus "split" samples. DC in groups 5-8 was recorded after storing samples at room temperature and humidity, in 90 +/- 2% humidity at 37 +/- 1 degrees C, distilled water at 37 +/- 1 degrees C or buffered incubation medium (BIM) at 37 +/- 1 degrees C for 24 h. Mean values of DC in polished and unpolished samples were 63.6% (+/- 3.2%) and 54.7% (+/- 5.2%), respectively (p lt 0.0001). There w...as no significant difference in DC after sample-sectioning (p > 0.05). Significantly higher DC values were obtained after storing samples in BIM (76.8% +/- 2.1%) than in distilled water (59.7% +/- 5.7%), extreme humidity (60.3% +/- 3.9%) or in room conditions (63.6% +/- 3.2%) (P lt 0.001). DC of an RBC measured by micro-Raman spectroscopy may be affected by differences in sample preparation and storing conditions, making it difficult to extrapolate data from in vitro studies into clinically relevant information.

Keywords:
micro-Raman spectroscopy / degree of conversion / resin-based composites / adhesive restorations / dental materials
Source:
Journal of Biomedical Materials Research Part B: Applied Biomaterials, 2008, 87B, 2, 468-474
Publisher:
  • Wiley, Hoboken

DOI: 10.1002/jbm.b.31128

ISSN: 1552-4973

PubMed: 18506816

WoS: 000260355000021

Scopus: 2-s2.0-55049139944
[ Google Scholar ]
45
34
URI
https://smile.stomf.bg.ac.rs/handle/123456789/1450
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Miletić, Vesna
AU  - Santini, Ario
PY  - 2008
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1450
AB  - The aim of this study was to measure degree of conversion (DC) of resin-based composites (RBCs) using micro-Raman spectroscopy followed by different sample preparation procedures and storing conditions. Ninety samples of Tetric EvoCeram (Ivoclar Vivadent, Schaan, Liechtenstein) were prepared in standardized molds and cured with a high powered LED light-curing unit, bluephase (R)) (Ivoclar Vivadent, Schaan, Liechtenstein) for 20 s. Samples were allocated to eight groups. DC of groups I and 2 was recorded without or after polishing. DC in groups 3 and 4 was recorded from vertically sectioned samples versus "split" samples. DC in groups 5-8 was recorded after storing samples at room temperature and humidity, in 90 +/- 2% humidity at 37 +/- 1 degrees C, distilled water at 37 +/- 1 degrees C or buffered incubation medium (BIM) at 37 +/- 1 degrees C for 24 h. Mean values of DC in polished and unpolished samples were 63.6% (+/- 3.2%) and 54.7% (+/- 5.2%), respectively (p  lt  0.0001). There was no significant difference in DC after sample-sectioning (p > 0.05). Significantly higher DC values were obtained after storing samples in BIM (76.8% +/- 2.1%) than in distilled water (59.7% +/- 5.7%), extreme humidity (60.3% +/- 3.9%) or in room conditions (63.6% +/- 3.2%) (P  lt  0.001). DC of an RBC measured by micro-Raman spectroscopy may be affected by differences in sample preparation and storing conditions, making it difficult to extrapolate data from in vitro studies into clinically relevant information.
PB  - Wiley, Hoboken
T2  - Journal of Biomedical Materials Research Part B: Applied Biomaterials
T1  - Remaining Unreacted Methacrylate Groups in Resin-Based Composite With Respect to Sample Preparation and Storing Conditions Using Micro-Raman Spectroscopy
VL  - 87B
IS  - 2
SP  - 468
EP  - 474
DO  - 10.1002/jbm.b.31128
ER  - 
@article{
author = "Miletić, Vesna and Santini, Ario",
year = "2008",
abstract = "The aim of this study was to measure degree of conversion (DC) of resin-based composites (RBCs) using micro-Raman spectroscopy followed by different sample preparation procedures and storing conditions. Ninety samples of Tetric EvoCeram (Ivoclar Vivadent, Schaan, Liechtenstein) were prepared in standardized molds and cured with a high powered LED light-curing unit, bluephase (R)) (Ivoclar Vivadent, Schaan, Liechtenstein) for 20 s. Samples were allocated to eight groups. DC of groups I and 2 was recorded without or after polishing. DC in groups 3 and 4 was recorded from vertically sectioned samples versus "split" samples. DC in groups 5-8 was recorded after storing samples at room temperature and humidity, in 90 +/- 2% humidity at 37 +/- 1 degrees C, distilled water at 37 +/- 1 degrees C or buffered incubation medium (BIM) at 37 +/- 1 degrees C for 24 h. Mean values of DC in polished and unpolished samples were 63.6% (+/- 3.2%) and 54.7% (+/- 5.2%), respectively (p  lt  0.0001). There was no significant difference in DC after sample-sectioning (p > 0.05). Significantly higher DC values were obtained after storing samples in BIM (76.8% +/- 2.1%) than in distilled water (59.7% +/- 5.7%), extreme humidity (60.3% +/- 3.9%) or in room conditions (63.6% +/- 3.2%) (P  lt  0.001). DC of an RBC measured by micro-Raman spectroscopy may be affected by differences in sample preparation and storing conditions, making it difficult to extrapolate data from in vitro studies into clinically relevant information.",
publisher = "Wiley, Hoboken",
journal = "Journal of Biomedical Materials Research Part B: Applied Biomaterials",
title = "Remaining Unreacted Methacrylate Groups in Resin-Based Composite With Respect to Sample Preparation and Storing Conditions Using Micro-Raman Spectroscopy",
volume = "87B",
number = "2",
pages = "468-474",
doi = "10.1002/jbm.b.31128"
}
Miletić, V.,& Santini, A.. (2008). Remaining Unreacted Methacrylate Groups in Resin-Based Composite With Respect to Sample Preparation and Storing Conditions Using Micro-Raman Spectroscopy. in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Wiley, Hoboken., 87B(2), 468-474.
https://doi.org/10.1002/jbm.b.31128
Miletić V, Santini A. Remaining Unreacted Methacrylate Groups in Resin-Based Composite With Respect to Sample Preparation and Storing Conditions Using Micro-Raman Spectroscopy. in Journal of Biomedical Materials Research Part B: Applied Biomaterials. 2008;87B(2):468-474.
doi:10.1002/jbm.b.31128 .
Miletić, Vesna, Santini, Ario, "Remaining Unreacted Methacrylate Groups in Resin-Based Composite With Respect to Sample Preparation and Storing Conditions Using Micro-Raman Spectroscopy" in Journal of Biomedical Materials Research Part B: Applied Biomaterials, 87B, no. 2 (2008):468-474,
https://doi.org/10.1002/jbm.b.31128 . .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB