Show simple item record

dc.creatorWeinlaender, Michael
dc.creatorLeković, Vojislav
dc.creatorŠpadijer-Gostović, Aleksandra
dc.creatorMiličić, Biljana
dc.creatorKrennmair, Gerald
dc.creatorPlenk, Hanns, Jr.
dc.date.accessioned2020-07-02T12:24:08Z
dc.date.available2020-07-02T12:24:08Z
dc.date.issued2009
dc.identifier.issn0905-7161
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1490
dc.description.abstractObjectives: A new method is introduced for the esthetic evaluation of the periimplant mucogingival complex through collection of standardized oral photographs and computer-assisted measurement of reproducible data. Using this method, different soft tissue and crown parameters in the dentogingival complex can be measured and the esthetic outcome monitored. Material and methods: A photographic device for standardized oral photography and a standard protocol for the esthetic evaluation of the crown-mucogingival complex is presented, comprising six soft tissue parameters: (1) mesial and (2) distal papilla areas, (3) mesial and (4) distal papilla heights, (5) soft tissue-crown perimeter, and (6) gingival recession. In order to demonstrate the reproducibility of standardized oral photographs and the accuracy of the measurement of the six parameters, the data obtained in each of two such standardized clinical photographs, taken at 10-14 days intervals, of the anterior maxillary region from 10 patients with no apparent dental disease were compared. For the statistical analysis of the reproducibility of these dependent data the 95% confidence interval and the coefficients of variation were calculated from measurement means and ranges of each of the above parameters, pooled from all 10 patients. Results: Statistical analysis revealed high reproducibility with no significant differences between the range of mean values of all six parameter measurements on the first and second standardized oral photograph of the same patient, respectively. Conclusion: Gingivomorphometry on standardized oral photographs can be considered to be an accurate and reproducible method for the evaluation and measurement of different dentogingival and periimplant parameters.en
dc.publisherWiley, Hoboken
dc.rightsrestrictedAccess
dc.sourceClinical Oral Implants Research
dc.subjectcomputerized measurementsen
dc.subjectesthetic evaluationen
dc.subjectstandardized photographyen
dc.titleGingivomorphometry - esthetic evaluation of the crown-mucogingival complex: a new method for collection and measurement of standardized and reproducible data in oral photographyen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractWеинлаендер, Мицхаел; Миличић, Биљана; Шпадијер-Гостовић, Aлександра; Лековић, Војислав; Креннмаир, Гералд; Пленк, Ханнс, Јр.;
dc.citation.volume20
dc.citation.issue5
dc.citation.spage526
dc.citation.epage530
dc.citation.other20(5): 526-530
dc.citation.rankaM21
dc.identifier.wos000265145700014
dc.identifier.doi10.1111/j.1600-0501.2008.01685.x
dc.identifier.pmid19522978
dc.identifier.scopus2-s2.0-64549152127
dc.type.versionpublishedVersion


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record