Приказ основних података о документу

Preciznost keramičkih kruna izrađenih primenom metoda intraoralnog optičkog skeniranja sistema Cerec® 3D

dc.creatorTrifković, Branka
dc.creatorTodorović, Aleksandar
dc.creatorJevremović, Danimir
dc.creatorPuškar, Tatjana
dc.creatorMarković, Dubravka
dc.date.accessioned2020-07-02T12:28:01Z
dc.date.available2020-07-02T12:28:01Z
dc.date.issued2010
dc.identifier.issn1451-3439
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1549
dc.description.abstractLong term use of intraoral optical scanning methods in the production of fixed dental restorations is one of the recognizable characteristics of Cerec® 3D CAD/CAM system. The aim of this study was to determine the degree of precision of ceramic crowns made by the technique of intraoral optical Cerec®3D scanning system. Material and methods The crowns prepared for the experimental group were scanned by the intraoral optical Cerec® 3D scanning system. In the control group, the porcelain-fused-to-metal crowns were made according to the conventional methodology. The crown accuracy was examined by measuring the size of the marginal gap between the crown and the marginal adaptation zone using the scanning microscope. Discussion The results showed that there was a difference in the accuracy between crowns of the experimental (50.27±31.50 μ) and the control group (132.92±53.21 μ). Conclusion The crowns made using the methods with intraoral optical scanning Cerec 3D system showed a high and clinically acceptable degree of accuracy.en
dc.description.abstractDugogodišnja primena metoda intraoralnog optičkog skeniranja u postupku izrade fiksnih zubnih nadoknada jedna je od osobenosti po kojoj je prepoznatljiv sistem Cerec®3D CAD/CAM. Cilj rada je bio da se utvrdi stepen preciznosti keramičkih kruna izrađenih primenom tehnike intraoralnog optičkog skeniranja sistema Cerec®3D. Ispitivanje je sprovedeno u okviru eksperimentalne grupe kruna u čijoj je izradi primenjena tehnika intraoralnog optičkog skeniranja sistema Cerec®3D. Metalokeramičke krune izrađene konvencionalnom metodologijom bile su kontrolna grupa. Preciznost kruna ispitivana je merenjem veličine marginalnog zjapa između ruba krune i demarkacije preparacije pomoću skenirajućeg elektronskog mikroskopa. Rezultati istraživanja pokazuju da postoji razlika u preciznosti kruna eksperimentalne (50,27±31,50μ) i kontrolne grupe (132,92+53,21μ). Krune izrađene primenom metoda intraoralnog optičkog skeniranja sistema Cerec 3D pokazuju visok i klinički prihvatljiv stepen preciznosti.sr
dc.publisherDruštvo lekara Vojvodine Srpskog lekarskog društva, Novi Sad
dc.rightsopenAccess
dc.sourceStomatološki informator
dc.subjectceramicsen
dc.subjectcrownsen
dc.subjecttomographyen
dc.subjectopticalen
dc.subjectcomputer-aided designen
dc.subjectdental marginal adaptationen
dc.subjectdental prosthesis designen
dc.subjectkeramikasr
dc.subjectkrunicesr
dc.subjectoptičko skeniranjesr
dc.subjectCAD/CAMsr
dc.subjectrubno zaptivanjesr
dc.subjectzubne nadoknadesr
dc.titleAccuracy of porcelain crowns made by using intraoral optical Cerec® 3DCAD/CAM systemen
dc.titlePreciznost keramičkih kruna izrađenih primenom metoda intraoralnog optičkog skeniranja sistema Cerec® 3Dsr
dc.typearticle
dc.rights.licenseARR
dcterms.abstractПушкар, Татјана; Марковић, Дубравка; Јевремовић, Данимир; Тодоровић, Aлександар; Трифковић, Бранка; Прецизност керамичких круна израђених применом метода интраоралног оптичког скенирања система Церец® 3Д; Прецизност керамичких круна израђених применом метода интраоралног оптичког скенирања система Церец® 3Д;
dc.citation.volume16
dc.citation.issue26
dc.citation.spage5
dc.citation.epage9
dc.citation.other16(26): 5-9
dc.citation.rankM53
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_smile_1549
dc.type.versionpublishedVersion


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу