Приказ основних података о документу

dc.creatorBrković, Božidar
dc.creatorSavić, Miroslav
dc.creatorAndrić, Miroslav
dc.creatorJurišić, Milan
dc.creatorTodorović, Ljubomir
dc.date.accessioned2020-07-02T12:29:03Z
dc.date.available2020-07-02T12:29:03Z
dc.date.issued2010
dc.identifier.issn1432-6981
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1565
dc.description.abstractThere is no data concerning the use of the intraseptal anaesthesia (ISA) for single tooth extraction. The aims of this study were to compare the clinical efficacy and haemodynamic responses of the ISA with the periodontal ligament anaesthesia (PLA) for single tooth extraction. Thirty-five randomly selected healthy patients (ASA I) undergoing maxillary lateral incisors extraction entered the study. Onset of anaesthesia, the width of the anaesthetic field and duration of anaesthesia were recorded by pinprick testing. Intensity of anaesthesia was evaluated on a visual analogue scale. Haemodynamic parameters were recorded simultaneously at different time points after anaesthesia injection. The two techniques of local anaesthesia did not show statistically significant differences regarding the success rate and onset of anaesthesia, while the duration of the ISA on the buccal site was significantly longer in comparison with the PLA. The intensity of the achieved anaesthesia, estimated by the experienced pain during procedure, pointed out that pain was recorded in 24% of cases in the ISA group, and in 19% in the PLA group without significant differences. Postoperative pain was found to be smaller in the ISA group (70.9% of treated sites) than in the PLA group (81.3% of treated sites); however, this difference was not significant. Although the heart rate increased in both groups, there were no significant differences in the patients' haemodynamic response between the ISA and the PLA. The results of the present study indicate that both techniques are useful and suitable for the routine tooth extraction.en
dc.publisherSpringer Heidelberg, Heidelberg
dc.relationinfo:eu-repo/grantAgreement/MESTD/MPN2006-2010/156039/RS//
dc.rightsrestrictedAccess
dc.sourceClinical Oral Investigations
dc.subjectIntraseptal local anaesthesiaen
dc.subjectPeriodontal ligament anaesthesiaen
dc.subjectTooth extractionen
dc.subjectAnaesthetic parametersen
dc.subjectHaemodynamic parametersen
dc.titleIntraseptal vs. periodontal ligament anaesthesia for maxillary tooth extraction: quality of local anaesthesia and haemodynamic responseen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractЈуришић, Милан; Aндрић, Мирослав; Брковић, Божидар; Тодоровић, Љубомир; Савић, Мирослав;
dc.citation.volume14
dc.citation.issue6
dc.citation.spage675
dc.citation.epage681
dc.citation.other14(6): 675-681
dc.citation.rankM21
dc.identifier.wos000284155700008
dc.identifier.doi10.1007/s00784-009-0352-7
dc.identifier.pmid19902278
dc.identifier.scopus2-s2.0-78449255792
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу