dc.description.abstractPurpose: This study was intended to investigate, through resonance frequency analysis (RFA), the stability of implants placed in an early loading protocol via the osteotome sinus floor elevation technique in the posterior maxilla. All implants featured a sandblasted/acid-etched active surface. Materials and Methods: An early loading protocol was considered for patients in whom implants with a sandblasted, large-grit/acid-etched active surface (SLActive) were placed in the posterior maxilla by the osteotome sinus floor elevation technique. Implant stability, which was measured by RFA at surgery and at weekly intervals for the following 6 weeks, was used as the most significant inclusion criterion. At the end of the stability observation period, only implants with a stability quotient of 65 or higher were loaded. Implants were followed for 2 years. Results: Twenty-seven patients received 42 implants, 40 of which were subjected to an early loading protocol 6 weeks after placement. Two years after loading, all 40 implants were surviving, without clinically or radiographically detectible complications. Conclusion: An early loading protocol can be used for SLActive implants placed in the posterior maxilla via the osteotome sinus floor elevation technique if their stability is confirmed by RFA. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:718-724en
dc.rightsrestrictedAccess
dc.sourceInternational Journal of Oral & Maxillofacial Implants
dc.subjectdental implantsen
dc.subjectearly loadingen
dc.subjectimplant stabilityen
dc.subjectresonance frequency analysisen
dc.subjectsinus floor elevationen
dc.subjectsurface propertiesen
dc.titleResonance Frequency Analysis as a Reliable Criterion for Early Loading of Sandblasted/Acid-Etched Active Surface Implants Placed by the Osteotome Sinus Floor Elevation Techniqueen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractТодоровић, Aлександар; Дражић, Радојица; Гачић, Бојан; Стајчић, Зоран; Марковић, Aлекса; Чолић, Сњежана;
dc.citation.volume26
dc.citation.issue4
dc.citation.spage718
dc.citation.epage724
dc.citation.other26(4): 718-724
dc.citation.rankM21
dc.identifier.wos000294523900003
dc.identifier.pmid21841979
dc.identifier.scopus2-s2.0-84555204375
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_smile_1626
dc.type.versionpublishedVersion


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record