Приказ основних података о документу

dc.creatorBiočanin, Vladimir
dc.creatorMilić, Marija
dc.creatorBrajković, Denis
dc.creatorBrković, Božidar
dc.creatorStojić, Dragica
dc.creatorTodorović, Ljubomir
dc.date.accessioned2020-07-02T12:35:17Z
dc.date.available2020-07-02T12:35:17Z
dc.date.issued2011
dc.identifier.issn1107-1141
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1660
dc.description.abstractObjective. The aim of this study was to investigate quality and safety of supplemental intraoral anesthesia - periodontal ligament anaesthesia (PDL) and intraseptal anaesthesia (ISA) after computer-controlled articaine delivery. Method. 54 ASA I volunteers randomly divided into 2 groups participated in this study. 0.4 ml of 4% articaine with 1:100.000 epinephrine were randomly administered with computer-controlled local anaesthetic delivery system on the mesial and distal side of maxillary lateral incisor for ISA or PDL. An electric pulp tester was used to test the pulpal anaesthesia, in 2-minute cycles for 60 minutes. Anaesthesia was considered successful when 2 or more consecutive no-response at 80 readings were obtained. Soft-tissue anaesthesia was measured by pin-prick test. Results. Success rates for ISA and PDL were 77.8% and 55.6% respectively, but difference was not statistically significant (p>0.05). Duration of complete pulpal anaesthesia was significantly longer (p lt 0.05) with the ISA in comparison to the PDL. The width of anesthetizied field was significantly greater (p lt 0.05) with the ISA than with the PDL, both for attached gingiva and oral mucosa. No side effects were recorded during the study. Conclusion. The results of this study indicate that the ISA technique is successful in obtaining complete pulpal anaesthesia of upper lateral incisors and soft-tissue anaesthesia in this area.en
dc.publisherUdruženje stomatologa Balkana
dc.rightsopenAccess
dc.sourceBalkan Journal of Stomatology
dc.subjectintraseptal anaesthesiaen
dc.subjectperiodontal ligament anaesthesiaen
dc.subjectarticaineen
dc.subjectcomputer-controlled local anaesthetic delivery systemen
dc.titleEfficacy of computer-controlled articaine delivery for supplemental intraoral anaesthesiaen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractСтојић, Драгица; Тодоровић, Љубомир; Брајковић, Денис; Биочанин, Владимир; Брковић, Божидар; Милић, Марија;
dc.citation.volume15
dc.citation.issue1
dc.citation.spage11
dc.citation.epage14
dc.citation.other15(1): 11-14
dc.citation.rankM52
dc.identifier.fulltexthttps://smile.stomf.bg.ac.rs/bitstream/id/410/1655.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_smile_1660
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу