Canal wall thickness after preparation with NiTi rotary files

Authorized Users Only
2012
Authors
Brkanić, Tatjana
Stojšin, Ivana
Živković, Slavoljub
Vukoje, Karolina
Article (Published version)
Metadata
Show full item record
Abstract
Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed, and safety of the preparation procedure. AIM: The aim of this research was to investigate measurement of maximal and minimal residual dentine thickness (RDT) and canal diameter after the canal preparation with different NiTi rotary files. METHODS: The research has been conducted on extracted human teeth in vitro conditions. The teeth have been divided in seven groups (20 teeth per group) depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper, and hand GT. The canals have been shaped in a crown-down manner and irrigated with 5.25% sodium hypochlorite. The roots of the teeth have been cut 1 and 3 mm from the apex. Apical preparation quality has been assessed under the polariz...ed light microscope. RESULTS: The maximal residual dentine thickness at distance 1 mm from apex, ranged from 1.16 to 1.45 mm, and at distance 3 mm from apex, from 1.44 to 1.84 mm. The minimal dentine thickness at distance 1 mm from apex ranged from 0.52 to 0.73 mm, and at distance 3 mm from apex, from 0.66 to 0.83 mm. The canal diameters after preparation at distance 1 mm from apex ranged from 0.42 to 0.49 mm, and at distance 3 mm from apex, from 0.53 to 0.63 mm. CONCLUSIONS: There was no significant difference neither in maximal and minimal RDT, nor in canal diameters shaped with different NiTi instruments tested. All tested NiTi files have accomplished good quality preparation of apical root canal parts. Microsc. Res. Tech., 2011.

Keywords:
residual dentin thickness / canal diameter / nickel-titanium / polarized light microscopy
Source:
Microscopy Research & Technique, 2012, 75, 3, 253-257
Publisher:
  • Wiley-Blackwell, Malden

DOI: 10.1002/jemt.21049

ISSN: 1059-910X

PubMed: 22038595

WoS: 000300689600001

Scopus: 2-s2.0-84857360724
[ Google Scholar ]
4
3
URI
http://smile.stomf.bg.ac.rs/handle/123456789/1751
Collections
  • Radovi istraživača
Institution
Stomatološki fakultet
TY  - JOUR
AU  - Brkanić, Tatjana
AU  - Stojšin, Ivana
AU  - Živković, Slavoljub
AU  - Vukoje, Karolina
PY  - 2012
UR  - http://smile.stomf.bg.ac.rs/handle/123456789/1751
AB  - Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed, and safety of the preparation procedure. AIM: The aim of this research was to investigate measurement of maximal and minimal residual dentine thickness (RDT) and canal diameter after the canal preparation with different NiTi rotary files. METHODS: The research has been conducted on extracted human teeth in vitro conditions. The teeth have been divided in seven groups (20 teeth per group) depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper, and hand GT. The canals have been shaped in a crown-down manner and irrigated with 5.25% sodium hypochlorite. The roots of the teeth have been cut 1 and 3 mm from the apex. Apical preparation quality has been assessed under the polarized light microscope. RESULTS: The maximal residual dentine thickness at distance 1 mm from apex, ranged from 1.16 to 1.45 mm, and at distance 3 mm from apex, from 1.44 to 1.84 mm. The minimal dentine thickness at distance 1 mm from apex ranged from 0.52 to 0.73 mm, and at distance 3 mm from apex, from 0.66 to 0.83 mm. The canal diameters after preparation at distance 1 mm from apex ranged from 0.42 to 0.49 mm, and at distance 3 mm from apex, from 0.53 to 0.63 mm. CONCLUSIONS: There was no significant difference neither in maximal and minimal RDT, nor in canal diameters shaped with different NiTi instruments tested. All tested NiTi files have accomplished good quality preparation of apical root canal parts. Microsc. Res. Tech., 2011.
PB  - Wiley-Blackwell, Malden
C3  - Microscopy Research & Technique
T1  - Canal wall thickness after preparation with NiTi rotary files
VL  - 75
IS  - 3
SP  - 253
EP  - 257
DO  - 10.1002/jemt.21049
ER  - 
@article{
author = "Brkanić, Tatjana and Stojšin, Ivana and Živković, Slavoljub and Vukoje, Karolina",
year = "2012",
url = "http://smile.stomf.bg.ac.rs/handle/123456789/1751",
abstract = "Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed, and safety of the preparation procedure. AIM: The aim of this research was to investigate measurement of maximal and minimal residual dentine thickness (RDT) and canal diameter after the canal preparation with different NiTi rotary files. METHODS: The research has been conducted on extracted human teeth in vitro conditions. The teeth have been divided in seven groups (20 teeth per group) depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper, and hand GT. The canals have been shaped in a crown-down manner and irrigated with 5.25% sodium hypochlorite. The roots of the teeth have been cut 1 and 3 mm from the apex. Apical preparation quality has been assessed under the polarized light microscope. RESULTS: The maximal residual dentine thickness at distance 1 mm from apex, ranged from 1.16 to 1.45 mm, and at distance 3 mm from apex, from 1.44 to 1.84 mm. The minimal dentine thickness at distance 1 mm from apex ranged from 0.52 to 0.73 mm, and at distance 3 mm from apex, from 0.66 to 0.83 mm. The canal diameters after preparation at distance 1 mm from apex ranged from 0.42 to 0.49 mm, and at distance 3 mm from apex, from 0.53 to 0.63 mm. CONCLUSIONS: There was no significant difference neither in maximal and minimal RDT, nor in canal diameters shaped with different NiTi instruments tested. All tested NiTi files have accomplished good quality preparation of apical root canal parts. Microsc. Res. Tech., 2011.",
publisher = "Wiley-Blackwell, Malden",
journal = "Microscopy Research & Technique",
title = "Canal wall thickness after preparation with NiTi rotary files",
volume = "75",
number = "3",
pages = "253-257",
doi = "10.1002/jemt.21049"
}
Brkanić T, Stojšin I, Živković S, Vukoje K. Canal wall thickness after preparation with NiTi rotary files. Microscopy Research & Technique. 2012;75(3):253-257
Brkanić, T., Stojšin, I., Živković, S.,& Vukoje, K. (2012). Canal wall thickness after preparation with NiTi rotary files.
Microscopy Research & TechniqueWiley-Blackwell, Malden., 75(3), 253-257.
https://doi.org/10.1002/jemt.21049
Brkanić Tatjana, Stojšin Ivana, Živković Slavoljub, Vukoje Karolina, "Canal wall thickness after preparation with NiTi rotary files" 75, no. 3 (2012):253-257,
https://doi.org/10.1002/jemt.21049 .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback