dc.description.abstractIntroduction: The purpose of this study was to evaluate the effect of autoclave sterilization on cyclic fatigue resistance of rotary endodontic instruments made of traditional and new nickel-titanium (NiTi) alloys. Methods: Four NiTi rotary endodontic instruments of the same size (tip diameter 0.40 mm and constant .04 taper) were selected: K3, Mtwo, Vortex, and K3 XF prototypes. Each group was then divided into 2 subgroups, unsterilized instruments and sterilized instruments. The sterilized instruments were subjected to 10 cycles of autoclave sterilization. Twelve files from each different subgroup were tested for cyclic fatigue resistance. Means and standard deviations of number of cycles to failure (NCF) and fragment length of the fractured tip were calculated for each group, and data were statistically analyzed (P lt .05). Results: Comparing the results between unsterilized and sterilized instruments for each type of file, differences were statistically significant (P lt .05) only between sterilized and unsterilized K3XF files (762 versus 651 NCF). The other instruments did not show significant differences (P > .05) in the mean NCF as a result of sterilization cycles (K3, 424 versus 439 NCF; Mtwo, 409 versus 419 NCF; Vortex, 454 versus 480 NCF). Comparing the results among the different groups, K3 XF (either sterilized or not) showed a mean NCF significantly higher than all other files(P lt .05). Conclusions: Repeated cycles of autoclave sterilization do not seem to influence the mechanical properties of NiTi endodontic instruments except for the K3 XF prototypes of rotary instruments that demonstrated a significant increase of cyclic fatigue resistance. (J Endod 2012;38:222-225)en
dc.publisherElsevier Science Inc, New York
dc.rightsrestrictedAccess
dc.sourceJournal of Endodontics
dc.subjectAutoclave sterilizationen
dc.subjectcyclic fatigueen
dc.subjectNiTi instrumentsen
dc.titleExperimental Evaluation on the Influence of Autoclave Sterilization on the Cyclic Fatigue of New Nickel-Titanium Rotary Instrumentsen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractГамбарини, Гианлуца; Цостанзо, Aлберто; Плотино, Гианлуца; Гранде, Ницола М.; Тестарелли, Луца; Петровић, Рената;
dc.citation.volume38
dc.citation.issue2
dc.citation.spage222
dc.citation.epage225
dc.citation.other38(2): 222-225
dc.citation.rankaM21
dc.identifier.wos000300195900018
dc.identifier.doi10.1016/j.joen.2011.10.017
dc.identifier.pmid22244641
dc.identifier.scopus2-s2.0-84855961014
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу