dc.description.abstractObjectives: To determine the degree of conversion (DC) over 48 h post-curing of resin mixtures containing trimethylbenzoyl-diphenylphosphine oxide (TPO) initiator cured by a polywave or a monowave LED light-curing unit (LCU). Methods: In resin mixtures based on equal weight percent (wt%) of BisGMA and TEGDMA the following initiators were added: 0.2 wt% camphorquinone (CQ) + 0.8 wt% ethyl-4-dimethylaminobenzoate (EDMAB) (Group 1); 1 wt% TPO (Group 2) and 0.1 wt% CQ + 0.4 wt% EDMAB + 0.5 wt% TPO (Group 3). Half of the samples in each group (n = 5) were cured using a polywave (bluephase (R) G2, Ivoclar Vivadent) or a monowave LED LCU (bluephase (R), Ivoclar Vivadent). The DC was measured using micro-Raman spectroscopy within 5 min and then 1, 3, 6, 24 and 48 h post-irradiation. The data were analysed using general linear model and two-way ANOVA for the factors 'time', 'material', 'surface' and 'LCU' at alpha = 0.05. Results: The initial DC values obtained upon light curing remained similar over a 48 h period. bluephase (R) G2 produced the highest DC in Group 2 followed by Group 3, and Group 1. bluephase (R) resulted in the highest DC in Group 1, followed by Group 2 and Group 3 (p lt 0.05). Conclusions: Unfilled resin materials containing both TPO- and CQ-amine initiators are effectively cured using bluephase (R) G2. Resin mixture with the same wt% of initiators is better cured when TPO is the only initiator, compared to CQ-amine only or combined TPO and CQ-amine system. After initial light cure, no additional conversion of uncured monomers was detected in an unfilled resin material over 48 h at 37 degrees C.en
dc.publisherElsevier Sci Ltd, Oxford
dc.relationIADR
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/172007/RS//
dc.rightsrestrictedAccess
dc.sourceJournal of Dentistry
dc.subjectDegree of conversionen
dc.subjectDimethacrylatesen
dc.subjectInitiatorsen
dc.subjectRamanen
dc.subjectComposite resinen
dc.subjectTPOen
dc.titleMicro-Raman spectroscopic analysis of the degree of conversion of composite resins containing different initiators cured by polywave or monowave LED unitsen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractСантини, Aрио; Милетић, Весна;
dc.citation.volume40
dc.citation.issue2
dc.citation.spage106
dc.citation.epage113
dc.citation.other40(2): 106-113
dc.citation.rankaM21
dc.identifier.wos000299317100002
dc.identifier.doi10.1016/j.jdent.2011.10.018
dc.identifier.pmid22094322
dc.identifier.scopus2-s2.0-84855902611
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу