Приказ основних података о документу

Utvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometrom

dc.creatorPuškar, Tatjana
dc.creatorWilliams, Robert J.
dc.creatorEggbeer, Dominic
dc.creatorJevremović, Danimir
dc.creatorLapčević, Ana
dc.creatorTrifković, Branka
dc.creatorVukelić, Đorđe
dc.date.accessioned2020-07-02T12:43:58Z
dc.date.available2020-07-02T12:43:58Z
dc.date.issued2013
dc.identifier.issn1821-4932
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1791
dc.description.abstractCorrosion resistance is one of the characteristics that dental alloy should possess as it should be placed in the oral cavity. Adverse tissue reactions of the gingiva and the periodontium close to dental cast alloys may be caused by the effects of released metal elements. Corrosion effect of dental Co-Cr-Mo alloy was investigated by ICP MS according to the EN ISO 10271 and EN ISO 22674. Co- Cr dental alloy Remanium GM 800+ (Dentaurum Ispringen, Germany was tested in artificial saliva for 7 days at 37ºC. The released metals were detected by Nexion 300X ICP MS (Perkin Elmer, USA). The results showed that the metal release was very low for Co, Cr and Mo, far below the permitted levels. ICP-MS can be considered as very reliable method for such a research.en
dc.description.abstractOtpornost na koroziju je jedna od karakteristika koju poseduju stomatološke legure koje trebaju biti postavljene u usnoj duplji. Neželjene reakcije tkiva gingive i parodoncijuma sa stomatološkim legurama može biti uzrokovano efektima oslobođenih metalnih elemenata. Efekat korozije stomatološke Co- Cr -Mo legure ispitana je ICP MS prema EN ISO 10271 i EN ISO 22674 . Co- Cr stomatološke legure Remanium GM 800 + ( Dentaurum Ispringen , testirano u Nemačkoj u veštačkoj pljuvački tokom 7 dana na 37º C. Otkriveni su oslobođeni metali Nekion 300Ks ICP MS ( Perkin Elmer , SAD ). Rezultati su pokazali veoma slabo oslobađanje metala, Cr i Mo , daleko ispod dozvoljenih nivoa. ICP -MS može smatrati veoma pouzdan metod za ovakvo istraživanje .sr
dc.publisherUniverzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
dc.rightsopenAccess
dc.sourceJournal of Production Engineering
dc.subjectdental alloyen
dc.subjectcorrosion resistanceen
dc.subjectICP MSen
dc.subjectstomatološke leguresr
dc.subjectotpornost na korozijusr
dc.subjectICP MSsr
dc.titleDetermination of corrosion characteristics of dental alloy by inductively coupled plasma mass spectrometryen
dc.titleUtvrđivanje korozionih karakteristika stomatološke legure sa induktivno spregnutim plazma masenim spektrometromsr
dc.typearticle
dc.rights.licenseARR
dcterms.abstractВукелић, Ђорђе; Лапчевић, Aна; Јевремовић, Данимир; Еггбеер, Доминиц; Пушкар, Татјана; Wиллиамс, Роберт Ј.; Трифковић, Бранка; Утврђивање корозионих карактеристика стоматолошке легуре са индуктивно спрегнутим плазма масеним спектрометром; Утврђивање корозионих карактеристика стоматолошке легуре са индуктивно спрегнутим плазма масеним спектрометром;
dc.citation.volume16
dc.citation.issue1
dc.citation.spage77
dc.citation.epage80
dc.citation.other16(1): 77-80
dc.citation.rankM52
dc.identifier.fulltexthttps://smile.stomf.bg.ac.rs/bitstream/id/502/1786.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_smile_1791
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу