Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites
No Thumbnail
Authors
Juloski, Jelena
Carrabba, Michele

Manuel Aragoneses, Juan

Forner, Leopoldo
Vichi, Alessandro
Ferrari, Marco

Article (Published version)

Metadata
Show full item recordAbstract
Purpose: To evaluate the microleakage of Class II cavities restored with experimental low-shrinking resin composites proposed for bulk filling and to measure their microtensile bond strength (mu TBS) to dentin and compare to those of previously marketed low-shrinkage composites. Methods: Class II cavities (7 mm occluso-gingival height, 2 mm mesio-distal depth of the box, 4 mm occlusal depth, 4 mm bucco-lingual width) were prepared in 50 molars and randomly divided into five groups (n=10), according to the material: SureFil SDR flow (SDR), Filtek Silorane (FS) and experimental materials (G-aenial Flo bulk fill, GF; G-aenial Universal Flo bulk fill, GUF; GC Kalore bulk fill, GK). Microleakage was separately assessed at enamel and dentin margins by scoring the depth of silver-nitrate penetration. Twenty teeth divided into five groups (n= 4) were selected for mu TBS testing. The same materials as for microleakage assessment were placed in bulk to mid-coronal dentin. Microtensile beams were... loaded in tension, and mu TBS at failure was calculated in MPa. Microleakage and mu TBS data were analyzed by ANOVA on ranks, followed Dunn's post hoc test (P lt 0.05). Results: Microleakage was not observed at the enamel interface in any of the groups. At the dentin interface, SDR recorded significantly higher microleakage than the other materials. mu TBS of GF, GUF and GK did not differ among each other (33 +/- 12 MPa, 31 +/- 11 MPa, 30 +/- 9 MPa, respectively), while SDR (63 +/- 17 MPa) and FS (55 +/- 17MPa) achieved significantly higher mu TBS values. No direct association between the sealing properties and the bond strength values was observed.
Source:
American Journal of Dentistry, 2013, 26, 5, 271-277Collections
Institution/Community
Stomatološki fakultetTY - JOUR AU - Juloski, Jelena AU - Carrabba, Michele AU - Manuel Aragoneses, Juan AU - Forner, Leopoldo AU - Vichi, Alessandro AU - Ferrari, Marco PY - 2013 UR - https://smile.stomf.bg.ac.rs/handle/123456789/1820 AB - Purpose: To evaluate the microleakage of Class II cavities restored with experimental low-shrinking resin composites proposed for bulk filling and to measure their microtensile bond strength (mu TBS) to dentin and compare to those of previously marketed low-shrinkage composites. Methods: Class II cavities (7 mm occluso-gingival height, 2 mm mesio-distal depth of the box, 4 mm occlusal depth, 4 mm bucco-lingual width) were prepared in 50 molars and randomly divided into five groups (n=10), according to the material: SureFil SDR flow (SDR), Filtek Silorane (FS) and experimental materials (G-aenial Flo bulk fill, GF; G-aenial Universal Flo bulk fill, GUF; GC Kalore bulk fill, GK). Microleakage was separately assessed at enamel and dentin margins by scoring the depth of silver-nitrate penetration. Twenty teeth divided into five groups (n= 4) were selected for mu TBS testing. The same materials as for microleakage assessment were placed in bulk to mid-coronal dentin. Microtensile beams were loaded in tension, and mu TBS at failure was calculated in MPa. Microleakage and mu TBS data were analyzed by ANOVA on ranks, followed Dunn's post hoc test (P lt 0.05). Results: Microleakage was not observed at the enamel interface in any of the groups. At the dentin interface, SDR recorded significantly higher microleakage than the other materials. mu TBS of GF, GUF and GK did not differ among each other (33 +/- 12 MPa, 31 +/- 11 MPa, 30 +/- 9 MPa, respectively), while SDR (63 +/- 17 MPa) and FS (55 +/- 17MPa) achieved significantly higher mu TBS values. No direct association between the sealing properties and the bond strength values was observed. T2 - American Journal of Dentistry T1 - Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites VL - 26 IS - 5 SP - 271 EP - 277 UR - https://hdl.handle.net/21.15107/rcub_smile_1820 ER -
@article{ author = "Juloski, Jelena and Carrabba, Michele and Manuel Aragoneses, Juan and Forner, Leopoldo and Vichi, Alessandro and Ferrari, Marco", year = "2013", abstract = "Purpose: To evaluate the microleakage of Class II cavities restored with experimental low-shrinking resin composites proposed for bulk filling and to measure their microtensile bond strength (mu TBS) to dentin and compare to those of previously marketed low-shrinkage composites. Methods: Class II cavities (7 mm occluso-gingival height, 2 mm mesio-distal depth of the box, 4 mm occlusal depth, 4 mm bucco-lingual width) were prepared in 50 molars and randomly divided into five groups (n=10), according to the material: SureFil SDR flow (SDR), Filtek Silorane (FS) and experimental materials (G-aenial Flo bulk fill, GF; G-aenial Universal Flo bulk fill, GUF; GC Kalore bulk fill, GK). Microleakage was separately assessed at enamel and dentin margins by scoring the depth of silver-nitrate penetration. Twenty teeth divided into five groups (n= 4) were selected for mu TBS testing. The same materials as for microleakage assessment were placed in bulk to mid-coronal dentin. Microtensile beams were loaded in tension, and mu TBS at failure was calculated in MPa. Microleakage and mu TBS data were analyzed by ANOVA on ranks, followed Dunn's post hoc test (P lt 0.05). Results: Microleakage was not observed at the enamel interface in any of the groups. At the dentin interface, SDR recorded significantly higher microleakage than the other materials. mu TBS of GF, GUF and GK did not differ among each other (33 +/- 12 MPa, 31 +/- 11 MPa, 30 +/- 9 MPa, respectively), while SDR (63 +/- 17 MPa) and FS (55 +/- 17MPa) achieved significantly higher mu TBS values. No direct association between the sealing properties and the bond strength values was observed.", journal = "American Journal of Dentistry", title = "Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites", volume = "26", number = "5", pages = "271-277", url = "https://hdl.handle.net/21.15107/rcub_smile_1820" }
Juloski, J., Carrabba, M., Manuel Aragoneses, J., Forner, L., Vichi, A.,& Ferrari, M.. (2013). Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites. in American Journal of Dentistry, 26(5), 271-277. https://hdl.handle.net/21.15107/rcub_smile_1820
Juloski J, Carrabba M, Manuel Aragoneses J, Forner L, Vichi A, Ferrari M. Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites. in American Journal of Dentistry. 2013;26(5):271-277. https://hdl.handle.net/21.15107/rcub_smile_1820 .
Juloski, Jelena, Carrabba, Michele, Manuel Aragoneses, Juan, Forner, Leopoldo, Vichi, Alessandro, Ferrari, Marco, "Microleakage of Class II restorations and microtensile bond strength to dentin of low-shrinkage composites" in American Journal of Dentistry, 26, no. 5 (2013):271-277, https://hdl.handle.net/21.15107/rcub_smile_1820 .