Приказ основних података о документу

dc.creatorAntonijević, Đorđe
dc.creatorObradović-Đuričić, Kosovka
dc.creatorRakočević, Zoran
dc.creatorMedigović, Ivana
dc.date.accessioned2020-07-02T12:46:20Z
dc.date.available2020-07-02T12:46:20Z
dc.date.issued2013
dc.identifier.issn0882-2786
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1827
dc.description.abstractPurpose: The aim of this in vitro study was to investigate the potential of digital and conventional radiography to detect small amounts of residual dental luting cements around implant abutments. Materials and Methods: Artificial cement and aluminum overhangs in varying thicknesses, heights, and depths were radiographed adjacent to implant restorations with a radiovisiography sensor. Five trained evaluators were asked to identify the smallest depth of overhang that could be detected on radiographs. Results: For detection of cement overhangs adjacent to implant abutments, a luting agent must have greater radiopacity than what is recommended by relevant International Organization for Standardization directives. To detect a 0.1-mm-thick portion of excess cement adjacent to an implant abutment, the cement should have a radiopacity of at least 1.7 mm of aluminum for high-resolution digital radiographs and 2.2 mm of aluminum for film-based radiographs. Two-way analysis of variance revealed that the thickness of the specimens, type of imaging detector, and type of cement all affected the radiopacity threshold for artificial cement excess (P lt .05). The height of the specimens and the surrounding structures were not statistically significant factors in cement detection. Conclusions: Digital radiography offers better possibilities for visualization of cement excess than conventional radiography.en
dc.publisherQuintessence Publishing Co Inc, Hanover Park
dc.rightsopenAccess
dc.sourceInternational Journal of Oral & Maxillofacial Implants
dc.subjectcement overhangen
dc.subjectdigital radiographyen
dc.subjectluting cementen
dc.subjectradiopacityen
dc.titleIn Vitro Radiographic Detection of Cement Overhangs on Cement-Retained Implant Restorationsen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractAнтонијевић, Ђорђе; Обрадовић-Ђуричић, Косовка; Ракочевић, Зоран; Медиговић, Ивана;
dc.citation.volume28
dc.citation.issue4
dc.citation.spage1068
dc.citation.epage1075
dc.citation.other28(4): 1068-1075
dc.citation.rankM22
dc.identifier.wos000322424700016
dc.identifier.doi10.11607/jomi.3057
dc.identifier.pmid23869365
dc.identifier.scopus2-s2.0-84899770900
dc.identifier.fulltexthttps://smile.stomf.bg.ac.rs/bitstream/id/3337/1822.pdf
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу