Приказ основних података о документу

dc.creatorGoracci, Cecilia
dc.creatorCadenaro, Milena
dc.creatorFontanive, Luca
dc.creatorGiangrosso, Giuseppe
dc.creatorJuloski, Jelena
dc.creatorVichi, Alessandro
dc.creatorFerrari, Marco
dc.date.accessioned2020-07-02T12:51:08Z
dc.date.available2020-07-02T12:51:08Z
dc.date.issued2014
dc.identifier.issn0109-5641
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1899
dc.description.abstractObjectives.To assess depth of cure (DOC), degree of conversion (DC), and flexural strength( FS) of several resin composites with low-stress behavior. Methods. SonicFill (Kerr), SureFil((R)) SDRTM (Dentsply), everX Posterior (GC), Kalore (GC), and Filtek Silorane (3M ESPE) were tested. DOC was measured with the Acetone Shake test. DC was assessed with Fourier Transform Infra-Red spectroscopy on top and at the bottom of 4 mm-thick disk-shaped specimens. Bottom to top ratios of DC percentages were calculated. FS was evaluated with the Three-Point Bending test. DOC, DC, and FS data were statistically analyzed. Results. SureFil((R)) SDRTM and everX Posterior achieved significantly greater DOC than Kalore and Filtek Silorane. Also, SonicFill had significantly greater DOC than Filtek Silorane. Mean top DCs ranged between 71.46% and 52.44%. Kalore and everX Posterior had significantly lower top DCs than the other materials. Mean DC values at 4 mm ranged largely from 57.95% to 6.82%. Kalore and Filtek Silorane had the lowest values of bottom DC and the difference was statistically significant. EverX Posterior and SonicFill recorded significantly higher FSs than the other materials. Significance. SureFil((R)) SDRTM and everX Posterior exhibited DOC over 4 mm, the maximum thickness recommended for bulk placement, while SonicFill recorded DOC values very close to the 4 mm threshold. SonicFill achieved the highest DC at the irradiated surface, as well as at 4 mm depth. SureFil((R)) SDRTM demonstrated similarly uniform curing through the bulk increment. All the tested composites complied with the requirements of FS established by ISO 4049/2009.en
dc.publisherElsevier Sci Ltd, Oxford
dc.rightsrestrictedAccess
dc.sourceDental Materials
dc.subjectBulk-fillen
dc.subjectFlexural strengthen
dc.subjectLow-stressen
dc.subjectPolymerizationen
dc.subjectResin compositeaen
dc.titlePolymerization efficiency and flexural strength of low-stress restorative compositesen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractГорацци, Цецилиа; Вицхи, Aлессандро; Фонтаниве, Луца; Гиангроссо, Гиусеппе; Јулоски, Јелена; Цаденаро, Милена; Феррари, Марцо;
dc.citation.volume30
dc.citation.issue6
dc.citation.spage688
dc.citation.epage694
dc.citation.other30(6): 688-694
dc.citation.rankaM21
dc.identifier.wos000335924300012
dc.identifier.doi10.1016/j.dental.2014.03.006
dc.identifier.pmid24703547
dc.identifier.scopus2-s2.0-84900816289
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу