Приказ основних података о документу

dc.creatorTrifković, Branka
dc.creatorBudak, Igor
dc.creatorTodorović, Aleksandar
dc.creatorVukelić, Đorđe
dc.creatorLazić, Vojkan
dc.creatorPuškar, Tatjana
dc.date.accessioned2020-07-02T12:53:12Z
dc.date.available2020-07-02T12:53:12Z
dc.date.issued2014
dc.identifier.issn0263-2241
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1931
dc.description.abstractImplementation of the methods of 3D digitization in dental practice is a modern and sophisticated alternative to the method of conventional impressions. Among many different methods of 3D digitization applied in dentistry, optical methods can be considered as today mostly applied, especially in the field of prosthodontics. The developments of this kind of systems have converged in two main directions - extraoral and intraoral systems. The main quality parameters for evaluating measuring performances of 3D digitization methods and systems include accuracy and precision. By introducing LED blue light in intra-and extraoral cameras, the Cerec system has significantly improved the quality of 3D digitization results. As the technical features of cameras in both types of systems are identical and the difference of the digitization methods is connected only to operating environments, the main goal of the research was to analyze whether different digitization conditions significantly influence the systems' measuring performances. Analyzes were focused on investigating accuracy and precision of two mentioned specialized dental optical systems on the basis of CAD inspection, with special attention on evaluating statistically significant differences within the obtained results. Statistically significant difference was not found in systems' precision, while the extra oral system was found as of significantly higher accuracy.en
dc.publisherElsevier Sci Ltd, Oxford
dc.relationinfo:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/35020/RS//
dc.rightsrestrictedAccess
dc.sourceMeasurement
dc.subject3D digitizationen
dc.subjectOptical dental systemsen
dc.subjectMeasuring performancesen
dc.subjectAccuracyen
dc.subjectPrecisionen
dc.titleComparative analysis on measuring performances of dental intraoral and extraoral optical 3D digitization systemsen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractТодоровић, Aлександар; Будак, Игор; Пушкар, Татјана; Лазић, Војкан; Трифковић, Бранка; Вукелић, Ђорђе;
dc.citation.volume47
dc.citation.spage45
dc.citation.epage53
dc.citation.other47: 45-53
dc.citation.rankM21
dc.identifier.wos000328196600008
dc.identifier.doi10.1016/j.measurement.2013.08.051
dc.identifier.scopus2-s2.0-84883739122
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу