Приказ основних података о документу

dc.creatorKoković, Vladimir
dc.creatorKršljak, Elena
dc.creatorAndrić, Miroslav
dc.creatorBrković, Božidar
dc.creatorMiličić, Biljana
dc.creatorJurišić, Milan
dc.creatorRahman, Muhammed Mustahsen
dc.creatorHaemmerle, Christoph H. F.
dc.date.accessioned2020-07-02T12:54:34Z
dc.date.available2020-07-02T12:54:34Z
dc.date.issued2014
dc.identifier.issn1056-6163
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1953
dc.description.abstractObjectives:Bone vascularity is an important factor in process of osseointegration. The aim of this study was to find whether or not blood perfusion of the bone around the prepared implant sites influences subsequent implant stability.Methods:Patients with bilaterally edentulous mandible were treated with dental implants. Bone vascularity in implant sites was previously noted using Laser Doppler Flowmetry (LDF). Implant stability quotient (ISQ) was measured during follow-up period of 26th week. Statistical distribution and correlation between LDF and ISQ values were presented. Other variables (type of implant loading; sex and distance from the apical part of implant sites to the roof of the mandibular canal) were collected and correlated with LDF values.Results:The mean recorded LDF value was 53.05 perfusion unit. Eighteen implants were immediately loaded, and the other 18 were early loaded. In the group of early loaded implants, a statistically significant correlation between mean value of LDF and changing value of resonance frequency analysis (P lt 0.05) was noted at 5th, 6th, 12th, and 26th weeks. Using Pearson coefficient of correlation, there was no statistically significant relationship between other variables and LDF values.Conclusion:LDF values of implant sites might determine future implant stability.en
dc.publisherLippincott Williams & Wilkins, Philadelphia
dc.relationinfo:eu-repo/grantAgreement/MESTD/Basic Research (BR or ON)/175021/RS//
dc.rightsopenAccess
dc.sourceImplant Dentistry
dc.subjectbone vascularityen
dc.subjectLaser Doppler Flowmetryen
dc.subjectmandibleen
dc.subjectposterioren
dc.subjectimplant stabilityen
dc.titleCorrelation of Bone Vascularity in the Posterior Mandible and Subsequent Implant Stability: A Preliminary Studyen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractAндрић, Мирослав; Коковић, Владимир; Хаеммерле, Цхристопх Х. Ф.; Рахман, Мухаммед Мустахсен; Јуришић, Милан; Брковић, Божидар; Кршљак, Елена; Миличић, Биљана;
dc.citation.volume23
dc.citation.issue2
dc.citation.spage200
dc.citation.epage205
dc.citation.other23(2): 200-205
dc.citation.rankM22
dc.identifier.wos000333568400017
dc.identifier.doi10.1097/ID.0000000000000057
dc.identifier.pmid24614879
dc.identifier.scopus2-s2.0-84897111039
dc.identifier.fulltexthttps://smile.stomf.bg.ac.rs/bitstream/id/3360/1948.pdf
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу