Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization

Authorized Users Only
2015
Authors
Ležaja, Maja
Veljović, Đorđe
Manojlović, Dragica
Milošević, Miloš
Mitrović, Nenad
Janaćković, Đorđe
Miletić, Vesna
Article (Published version)
Metadata
Show full item record
Abstract
Objective. To determine the shear bond strength (SBS) between synthetic controlled porous hydroxyapatite (HAP) inserts and restorative materials and dimensional changes of insert-containing restorations during curing. Methods. Cylinder-shaped HAP inserts (4 mm in diameter, 1.6 mm thick) were cemented in dentin discs (5 mm x 1.6 mm), cut mid-coronally from human third molars, using one of the following materials: universal microhybrid composite Filtek Z250, flowable composite Filtek Ultimate or glass-ionomer Vitrebond (all 3M ESPE). SBS of the same materials to HAP inserts was tested in a universal testing machine. Three-dimensional digital image correlation system Aramis (GOM) was used to measure strains and displacements. Data were statistically analyzed using one-way ANOVA with Tukey's post-test (alpha = 0.05). Results. SBS of restorative materials to HAP inserts ranged between 12.2 +/- 2.1 MPa (Filtek Z250) and 0.7 +/- 0.4 MPa (Filtek Z250 without an adhesive). The 'total-etch' appr...oach of adhesive application significantly increased SBS of both Filtek Z250 (12.2 +/- 2.1 MPa) and Filtek Ultimate flowable (9.5 +/- 2.5 MPa) compared to the 'self-etch' approach (8.2 +/- 1.6 MPa and 4.4 +/- 0.9 MPa, respectively) (p lt 0.05). HAP inserts reduced polymerization shrinkage to below 0.5% as well as displacements in the central region of the restorations. Peripheral shrinkage of restorative materials was similar with and without HAP inserts as were displacements of Filtek Z250 and Vitrebond. Significance. Replacing major part of dentin clinically, especially in large cavities, HAP inserts may shorten clinical working time, improve dimensional stability of the restoration by reducing central shrinkage and displacements and provide adhesive bonding to universal composites following a 'total-etch' approach.

Keywords:
Hydroxyapatite / Inserts / Bond strength / Polymerization shrinkage / Dentin / Composite / Glass-ionomer / Adhesive
Source:
Dental Materials, 2015, 31, 2, 171-181
Publisher:
  • Elsevier Sci Ltd, Oxford
Funding / projects:
  • Development and Application of Methods and Materials for Monitoring New Organic Contaminants, Toxic Compounds and Heavy Metals (RS-172007)
  • Synthesis, processing and applications of nanostructured multifunctional materials with defined properties (RS-45019)
  • Developed new methods for diagnosis and examination mechanical structures (RS-35040)

DOI: 10.1016/j.dental.2014.11.017

ISSN: 0109-5641

PubMed: 25541508

WoS: 000349759400017

Scopus: 2-s2.0-84920937564
[ Google Scholar ]
15
10
URI
https://smile.stomf.bg.ac.rs/handle/123456789/1962
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Ležaja, Maja
AU  - Veljović, Đorđe
AU  - Manojlović, Dragica
AU  - Milošević, Miloš
AU  - Mitrović, Nenad
AU  - Janaćković, Đorđe
AU  - Miletić, Vesna
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1962
AB  - Objective. To determine the shear bond strength (SBS) between synthetic controlled porous hydroxyapatite (HAP) inserts and restorative materials and dimensional changes of insert-containing restorations during curing. Methods. Cylinder-shaped HAP inserts (4 mm in diameter, 1.6 mm thick) were cemented in dentin discs (5 mm x 1.6 mm), cut mid-coronally from human third molars, using one of the following materials: universal microhybrid composite Filtek Z250, flowable composite Filtek Ultimate or glass-ionomer Vitrebond (all 3M ESPE). SBS of the same materials to HAP inserts was tested in a universal testing machine. Three-dimensional digital image correlation system Aramis (GOM) was used to measure strains and displacements. Data were statistically analyzed using one-way ANOVA with Tukey's post-test (alpha = 0.05). Results. SBS of restorative materials to HAP inserts ranged between 12.2 +/- 2.1 MPa (Filtek Z250) and 0.7 +/- 0.4 MPa (Filtek Z250 without an adhesive). The 'total-etch' approach of adhesive application significantly increased SBS of both Filtek Z250 (12.2 +/- 2.1 MPa) and Filtek Ultimate flowable (9.5 +/- 2.5 MPa) compared to the 'self-etch' approach (8.2 +/- 1.6 MPa and 4.4 +/- 0.9 MPa, respectively) (p  lt  0.05). HAP inserts reduced polymerization shrinkage to below 0.5% as well as displacements in the central region of the restorations. Peripheral shrinkage of restorative materials was similar with and without HAP inserts as were displacements of Filtek Z250 and Vitrebond. Significance. Replacing major part of dentin clinically, especially in large cavities, HAP inserts may shorten clinical working time, improve dimensional stability of the restoration by reducing central shrinkage and displacements and provide adhesive bonding to universal composites following a 'total-etch' approach.
PB  - Elsevier Sci Ltd, Oxford
T2  - Dental Materials
T1  - Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization
VL  - 31
IS  - 2
SP  - 171
EP  - 181
DO  - 10.1016/j.dental.2014.11.017
ER  - 
@article{
author = "Ležaja, Maja and Veljović, Đorđe and Manojlović, Dragica and Milošević, Miloš and Mitrović, Nenad and Janaćković, Đorđe and Miletić, Vesna",
year = "2015",
abstract = "Objective. To determine the shear bond strength (SBS) between synthetic controlled porous hydroxyapatite (HAP) inserts and restorative materials and dimensional changes of insert-containing restorations during curing. Methods. Cylinder-shaped HAP inserts (4 mm in diameter, 1.6 mm thick) were cemented in dentin discs (5 mm x 1.6 mm), cut mid-coronally from human third molars, using one of the following materials: universal microhybrid composite Filtek Z250, flowable composite Filtek Ultimate or glass-ionomer Vitrebond (all 3M ESPE). SBS of the same materials to HAP inserts was tested in a universal testing machine. Three-dimensional digital image correlation system Aramis (GOM) was used to measure strains and displacements. Data were statistically analyzed using one-way ANOVA with Tukey's post-test (alpha = 0.05). Results. SBS of restorative materials to HAP inserts ranged between 12.2 +/- 2.1 MPa (Filtek Z250) and 0.7 +/- 0.4 MPa (Filtek Z250 without an adhesive). The 'total-etch' approach of adhesive application significantly increased SBS of both Filtek Z250 (12.2 +/- 2.1 MPa) and Filtek Ultimate flowable (9.5 +/- 2.5 MPa) compared to the 'self-etch' approach (8.2 +/- 1.6 MPa and 4.4 +/- 0.9 MPa, respectively) (p  lt  0.05). HAP inserts reduced polymerization shrinkage to below 0.5% as well as displacements in the central region of the restorations. Peripheral shrinkage of restorative materials was similar with and without HAP inserts as were displacements of Filtek Z250 and Vitrebond. Significance. Replacing major part of dentin clinically, especially in large cavities, HAP inserts may shorten clinical working time, improve dimensional stability of the restoration by reducing central shrinkage and displacements and provide adhesive bonding to universal composites following a 'total-etch' approach.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Dental Materials",
title = "Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization",
volume = "31",
number = "2",
pages = "171-181",
doi = "10.1016/j.dental.2014.11.017"
}
Ležaja, M., Veljović, Đ., Manojlović, D., Milošević, M., Mitrović, N., Janaćković, Đ.,& Miletić, V.. (2015). Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization. in Dental Materials
Elsevier Sci Ltd, Oxford., 31(2), 171-181.
https://doi.org/10.1016/j.dental.2014.11.017
Ležaja M, Veljović Đ, Manojlović D, Milošević M, Mitrović N, Janaćković Đ, Miletić V. Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization. in Dental Materials. 2015;31(2):171-181.
doi:10.1016/j.dental.2014.11.017 .
Ležaja, Maja, Veljović, Đorđe, Manojlović, Dragica, Milošević, Miloš, Mitrović, Nenad, Janaćković, Đorđe, Miletić, Vesna, "Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization" in Dental Materials, 31, no. 2 (2015):171-181,
https://doi.org/10.1016/j.dental.2014.11.017 . .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB