SMILE – Repozitorijum Stomatološkog fakulteta
Univerzitet u Beogradu - Stomatološki fakultet
    • English
    • Српски
    • Српски (Serbia)
  • Srpski (latinica) 
    • Engleski
    • Srpski (ćirilica)
    • Srpski (latinica)
  • Prijava
Pregled zapisa 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • Pregled zapisa
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • Pregled zapisa
JavaScript is disabled for your browser. Some features of this site may not work without it.

Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization

Samo za registrovane korisnike
2015
Autori
Ležaja, Maja
Veljović, Đorđe
Manojlović, Dragica
Milošević, Miloš
Mitrović, Nenad
Janaćković, Đorđe
Miletić, Vesna
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentu
Apstrakt
Objective. To determine the shear bond strength (SBS) between synthetic controlled porous hydroxyapatite (HAP) inserts and restorative materials and dimensional changes of insert-containing restorations during curing. Methods. Cylinder-shaped HAP inserts (4 mm in diameter, 1.6 mm thick) were cemented in dentin discs (5 mm x 1.6 mm), cut mid-coronally from human third molars, using one of the following materials: universal microhybrid composite Filtek Z250, flowable composite Filtek Ultimate or glass-ionomer Vitrebond (all 3M ESPE). SBS of the same materials to HAP inserts was tested in a universal testing machine. Three-dimensional digital image correlation system Aramis (GOM) was used to measure strains and displacements. Data were statistically analyzed using one-way ANOVA with Tukey's post-test (alpha = 0.05). Results. SBS of restorative materials to HAP inserts ranged between 12.2 +/- 2.1 MPa (Filtek Z250) and 0.7 +/- 0.4 MPa (Filtek Z250 without an adhesive). The 'total-etch' appr...oach of adhesive application significantly increased SBS of both Filtek Z250 (12.2 +/- 2.1 MPa) and Filtek Ultimate flowable (9.5 +/- 2.5 MPa) compared to the 'self-etch' approach (8.2 +/- 1.6 MPa and 4.4 +/- 0.9 MPa, respectively) (p lt 0.05). HAP inserts reduced polymerization shrinkage to below 0.5% as well as displacements in the central region of the restorations. Peripheral shrinkage of restorative materials was similar with and without HAP inserts as were displacements of Filtek Z250 and Vitrebond. Significance. Replacing major part of dentin clinically, especially in large cavities, HAP inserts may shorten clinical working time, improve dimensional stability of the restoration by reducing central shrinkage and displacements and provide adhesive bonding to universal composites following a 'total-etch' approach.

Ključne reči:
Hydroxyapatite / Inserts / Bond strength / Polymerization shrinkage / Dentin / Composite / Glass-ionomer / Adhesive
Izvor:
Dental Materials, 2015, 31, 2, 171-181
Izdavač:
  • Elsevier Sci Ltd, Oxford
Finansiranje / projekti:
  • Razvoj i primena metoda i materijala za monitoring novih zagađujućih i toksičnih organskih materija i teških metala (RS-172007)
  • Sinteza, razvoj tehnologija dobijanja i primena nanostrukturnih multifunkcionalnih materijala definisanih svojstava (RS-45019)
  • Razvoj savremenih metoda dijagnostike i ispitivanja mašinskih struktura (RS-35040)

DOI: 10.1016/j.dental.2014.11.017

ISSN: 0109-5641

PubMed: 25541508

WoS: 000349759400017

Scopus: 2-s2.0-84920937564
[ Google Scholar ]
18
10
URI
https://smile.stomf.bg.ac.rs/handle/123456789/1962
Kolekcije
  • Radovi istraživača
Institucija/grupa
Stomatološki fakultet
TY  - JOUR
AU  - Ležaja, Maja
AU  - Veljović, Đorđe
AU  - Manojlović, Dragica
AU  - Milošević, Miloš
AU  - Mitrović, Nenad
AU  - Janaćković, Đorđe
AU  - Miletić, Vesna
PY  - 2015
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1962
AB  - Objective. To determine the shear bond strength (SBS) between synthetic controlled porous hydroxyapatite (HAP) inserts and restorative materials and dimensional changes of insert-containing restorations during curing. Methods. Cylinder-shaped HAP inserts (4 mm in diameter, 1.6 mm thick) were cemented in dentin discs (5 mm x 1.6 mm), cut mid-coronally from human third molars, using one of the following materials: universal microhybrid composite Filtek Z250, flowable composite Filtek Ultimate or glass-ionomer Vitrebond (all 3M ESPE). SBS of the same materials to HAP inserts was tested in a universal testing machine. Three-dimensional digital image correlation system Aramis (GOM) was used to measure strains and displacements. Data were statistically analyzed using one-way ANOVA with Tukey's post-test (alpha = 0.05). Results. SBS of restorative materials to HAP inserts ranged between 12.2 +/- 2.1 MPa (Filtek Z250) and 0.7 +/- 0.4 MPa (Filtek Z250 without an adhesive). The 'total-etch' approach of adhesive application significantly increased SBS of both Filtek Z250 (12.2 +/- 2.1 MPa) and Filtek Ultimate flowable (9.5 +/- 2.5 MPa) compared to the 'self-etch' approach (8.2 +/- 1.6 MPa and 4.4 +/- 0.9 MPa, respectively) (p  lt  0.05). HAP inserts reduced polymerization shrinkage to below 0.5% as well as displacements in the central region of the restorations. Peripheral shrinkage of restorative materials was similar with and without HAP inserts as were displacements of Filtek Z250 and Vitrebond. Significance. Replacing major part of dentin clinically, especially in large cavities, HAP inserts may shorten clinical working time, improve dimensional stability of the restoration by reducing central shrinkage and displacements and provide adhesive bonding to universal composites following a 'total-etch' approach.
PB  - Elsevier Sci Ltd, Oxford
T2  - Dental Materials
T1  - Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization
VL  - 31
IS  - 2
SP  - 171
EP  - 181
DO  - 10.1016/j.dental.2014.11.017
ER  - 
@article{
author = "Ležaja, Maja and Veljović, Đorđe and Manojlović, Dragica and Milošević, Miloš and Mitrović, Nenad and Janaćković, Đorđe and Miletić, Vesna",
year = "2015",
abstract = "Objective. To determine the shear bond strength (SBS) between synthetic controlled porous hydroxyapatite (HAP) inserts and restorative materials and dimensional changes of insert-containing restorations during curing. Methods. Cylinder-shaped HAP inserts (4 mm in diameter, 1.6 mm thick) were cemented in dentin discs (5 mm x 1.6 mm), cut mid-coronally from human third molars, using one of the following materials: universal microhybrid composite Filtek Z250, flowable composite Filtek Ultimate or glass-ionomer Vitrebond (all 3M ESPE). SBS of the same materials to HAP inserts was tested in a universal testing machine. Three-dimensional digital image correlation system Aramis (GOM) was used to measure strains and displacements. Data were statistically analyzed using one-way ANOVA with Tukey's post-test (alpha = 0.05). Results. SBS of restorative materials to HAP inserts ranged between 12.2 +/- 2.1 MPa (Filtek Z250) and 0.7 +/- 0.4 MPa (Filtek Z250 without an adhesive). The 'total-etch' approach of adhesive application significantly increased SBS of both Filtek Z250 (12.2 +/- 2.1 MPa) and Filtek Ultimate flowable (9.5 +/- 2.5 MPa) compared to the 'self-etch' approach (8.2 +/- 1.6 MPa and 4.4 +/- 0.9 MPa, respectively) (p  lt  0.05). HAP inserts reduced polymerization shrinkage to below 0.5% as well as displacements in the central region of the restorations. Peripheral shrinkage of restorative materials was similar with and without HAP inserts as were displacements of Filtek Z250 and Vitrebond. Significance. Replacing major part of dentin clinically, especially in large cavities, HAP inserts may shorten clinical working time, improve dimensional stability of the restoration by reducing central shrinkage and displacements and provide adhesive bonding to universal composites following a 'total-etch' approach.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Dental Materials",
title = "Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization",
volume = "31",
number = "2",
pages = "171-181",
doi = "10.1016/j.dental.2014.11.017"
}
Ležaja, M., Veljović, Đ., Manojlović, D., Milošević, M., Mitrović, N., Janaćković, Đ.,& Miletić, V.. (2015). Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization. in Dental Materials
Elsevier Sci Ltd, Oxford., 31(2), 171-181.
https://doi.org/10.1016/j.dental.2014.11.017
Ležaja M, Veljović Đ, Manojlović D, Milošević M, Mitrović N, Janaćković Đ, Miletić V. Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization. in Dental Materials. 2015;31(2):171-181.
doi:10.1016/j.dental.2014.11.017 .
Ležaja, Maja, Veljović, Đorđe, Manojlović, Dragica, Milošević, Miloš, Mitrović, Nenad, Janaćković, Đorđe, Miletić, Vesna, "Bond strength of restorative materials to hydroxyapatite inserts and dimensional changes of insert-containing restorations during polymerization" in Dental Materials, 31, no. 2 (2015):171-181,
https://doi.org/10.1016/j.dental.2014.11.017 . .

DSpace software copyright © 2002-2015  DuraSpace
O SMILE – School of dental Medicine dIgitaL archivE | Pošaljite zapažanja

OpenAIRERCUB
 

 

Kompletan repozitorijumGrupeAutoriNasloviTemeOva institucijaAutoriNasloviTeme

Statistika

Pregled statistika

DSpace software copyright © 2002-2015  DuraSpace
O SMILE – School of dental Medicine dIgitaL archivE | Pošaljite zapažanja

OpenAIRERCUB