In-vitro evaluation of the retention of different prefabricated posts luted with different cements
(Institute of Metals and Technology, 2012)
The aim of this study was to assess and compare the mechanical resistance and the retentive force of metal and composite post systems cemented with different types of cements. Three different designs of prefabricated ...
Nanofoils for soldering and brazing in dental joining practice and jewellery manufacturing
(Institute of Metals and Technology, 2010)
This paper describes the development of novel, reactive Al-Au nano-multilayered foils, their possible application in different fields and a discussion of the nano-foils' suitability for dental and jewellery applications. ...
Experimental analysis of dental-implant load transfer in polymethyl-methacrylate blocks
(Inst Za Kovinske Materiale I In Tehnologie, Ljubjana, 2019)
Dental-implant overload can cause bone resorption. Load-transfer characteristics of dental implants are affected by their macro-design parameters. The goal of this study was to experimentally analyse the load-transfer ...
Aspects of titanium-implant surface modification at the micro and nano levels
(Institute of Metals and Technology, 2012)
The shape and chemical composition, as well as the macro- and microtopography, of an implant surface have been studied widely as the major factors that positively influence implant osseointegration. Titanium and titanium ...
Liquid metal/ceramic interfaces in dental practice and jewellery manufacturing
(Institute of Metals and Technology, 2010)
Metal-ceramic fusing has been the essential step in obtaining materials that benefit from both ceramic and metal constituents. i e where the combined properties of metal and ceramic layers are desirable When considering ...
Biomechanical interactions between bone and metal-ceramic bridges composed of different types of non-noble alloys under vertical loading conditions
(Institute of Metals Technology, 2014)
The purpose of this study was to compare the mechanical properties of three metal-ceramic bridges of different types of dental alloys and to present and evaluate the possible biomechanical interactions between a marginal ...
Mechanical properties of the materials for bruxoguards
(Institute of Metals Technology, 2014)
The aim of this study is to investigate the mechanical properties of polymethyl methacrylate (PMMA) and thermoplastic polycarbonate (TPC) materials in order to produce night bruxoguards. For this purpose we used a static ...
Characterization of glass ionomer cements stored in various solutions
(Inst Za Kovinske Materiale I In Tehnologie, Ljubjana, 2019)
The aim of this work was to evaluate the nano-mechanical properties of glass ionomer materials, the ion concentrations at the surfaces in relation to the storage media and the pH environments using a scanning electron ...
Synthesis of PMMA/ZNO nanoparticles composite used for resin teeth
(Inst Za Kovinske Materiale I In Tehnologie, Ljubjana, 2017)
Wear resistance is one of the most important physical properties of the artificial teeth used in acrylic dentures. The goal of this research was to synthesize a new composite material made of matrix Poly-(methyl ...
Comparison of niti orthodontic archwires and a determination of the characteristic properties
(Institute of Metals and Technology, 2014)
The aim of this paper was to analyse the characteristic properties of six different, commercially available nickel-titanium orthodontic wires with a diameter of 0.305 mm (0.014"). The characteristic properties were determined ...