Приказ основних података о документу

Primena CAD/CAM tehnologije u projektovanju i izradi mostova pune anatomske forme na bazi cirkonijum-dioksida

dc.creatorLapčević, Ana
dc.creatorJevremović, Danimir
dc.creatorTrifković, Branka
dc.creatorSantoši, Željko
dc.creatorVukelić, Đorđe
dc.date.accessioned2020-07-02T13:01:49Z
dc.date.available2020-07-02T13:01:49Z
dc.date.issued2015
dc.identifier.issn1821-4932
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/2067
dc.description.abstractDaily progress of dentistry, especially in the field of prosthodontics is introducing new materials and technologies. With the increasing need for aesthetically acceptable and non-metal materials, it came to development and improvement of ceramic materials and computer based systems (CA). The patient came in order to compensate the missing left lateral incisor. Since the adjacent teeth are brushed and the print was taken, casted model has been scanned using 3Shape D800 laboratory scanner. Dental restoration has been designed using 3Shape DentalSystem Premium software and the available tools. After completing the virtual design, the data are sent to the program responsible for CAM Zenotec® mini CAD/CAM device. As a result, the compensation with the full morphology was obtained without the need for finishing works.en
dc.description.abstractStomatologija, posebno stomatološka protetika svakodnevno napreduje uvođenjem novih materijala i tehnologija. Kako se javlja sve veća potreba za estetski prihvatljivim i bezmetalnim materijalima, došlo je do razvoja i unapređenja keramičkih materijala i računarima podržanih sistema (CA). Pacijent se javio radi nadoknade nedostajućeg levog bočnog sekutića. Pošto su susedni zubi zbrušeni i uzet otisak, izliven je model koji je skeniran pomoću 3Shape D 800 laboratorijskog skenera. Zubna nadoknada je dizajnirana pomo ću 3Shape DentalSystem Premium softvera korišćenjem raspoloživih alata. Nakon završenog dizajna virtuelni podaci su poslati u program odgovoran za CAM Zenotec® mini CAD/CAM uređaja. Kao rezultat, dobijena je nadoknada pune morfologije bez potrebe za dorađivanjem.sr
dc.publisherUniverzitet u Novom Sadu - Fakultet tehničkih nauka - Departman za proizvodno mašinstvo, Novi Sad
dc.relationinfo:eu-repo/grantAgreement/MESTD/Technological Development (TD or TR)/35020/RS//
dc.rightsopenAccess
dc.sourceJournal of Production Engineering
dc.subjectCAD/CAMen
dc.subjectzirconium dioxideen
dc.subjectdental restorationsen
dc.subjectCAD/CAMsr
dc.subjectcirkonijum-oksidsr
dc.subjectzubne nadoknadesr
dc.titleApplication of CAD/CAM technology in the design and creation of full anatomic bridge form zirconium dioxideen
dc.titlePrimena CAD/CAM tehnologije u projektovanju i izradi mostova pune anatomske forme na bazi cirkonijum-dioksidasr
dc.typearticle
dc.rights.licenseARR
dcterms.abstractТрифковић, Бранка; Вукелић, Ђорђе; Сантоши, Жељко; Лапчевић, Aна; Јевремовић, Данимир; Примена ЦAД/ЦAМ технологије у пројектовању и изради мостова пуне анатомске форме на бази цирконијум-диоксида; Примена ЦAД/ЦAМ технологије у пројектовању и изради мостова пуне анатомске форме на бази цирконијум-диоксида;
dc.citation.volume18
dc.citation.issue1
dc.citation.spage73
dc.citation.epage75
dc.citation.other18(1): 73-75
dc.citation.rankM52
dc.identifier.fulltexthttps://smile.stomf.bg.ac.rs/bitstream/id/696/2062.pdf
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_smile_2067
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу