Приказ основних података о документу

dc.creatorMitrović, Nenad
dc.creatorTanasić, Ivan
dc.creatorŠarac, Dušan
dc.creatorMilošević, Miloš
dc.creatorMisković, Žarko
dc.creatorTihaček-Šojić, Ljiljana
dc.creatorSedmak, Aleksandar
dc.date.accessioned2020-07-02T13:04:38Z
dc.date.available2020-07-02T13:04:38Z
dc.date.issued2016
dc.identifier.issn2452-3216
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/2113
dc.description.abstractStrain analysis in the vicinity of the dental implants were the subject of many research papers. In this study, new experimental method was employed for strain determination in the surrounding area of the axially loaded dental implant, which was embedded in the resin block. This studies can improve understanding of strain distribution, and its possible effects on the surrounding structure. Dental Implant Branemark with dimensions of 14 x 3.75 mm was immersed into rectangular block of polymethil methacrylate in vertical position. Implant was distanced 2 mm and 4 mm from the block sides, and they were named as the surface 1 and surface 2, respectively. Axial load, in the range of 0 - 500 N, was applied using Universal testing machine Tinius Olsen. Digital Image Correlation method was used for measuring deformation. Results were presented in the form of horizontal and vertical strains. Horizontal strains were mostly tensile, with maximum value of 0.3 % on the bottom of the surface 1. This values decreased in the upper area of the block side. Vertical compressive strain were 2-3 times higher on the surface 1, when compared to the surface 2, with maximum values of 0.7 % located on the bottom of the surface 1, and 0.3 % on the bottom of the surface 2. Resin block models could be used for determination of strain distribution under axially loaded implants. Greatest strain concentration were located under the implants apex, in the bottom area of the block. It was concluded that, in this region, strain values decreased linearly with increase of distance from the implants surface.en
dc.publisherElsevier Science Bv, Amsterdam
dc.rightsopenAccess
dc.source21st European Conference on Fracture, (ECF21)
dc.subjectDigital Implant Correlationen
dc.subjectDental implanten
dc.subjectStrain analysisen
dc.subjectBlock modelen
dc.subjectPoly-methyl-methacrylateen
dc.titleAnalysis of the effect of implant distance from the surrounding structure, in the PMMA block modelen
dc.typeconferenceObject
dc.rights.licenseARR
dcterms.abstractМитровић, Ненад; Шарац, Душан; Милошевић, Милош; Тихачек-Шојић, Љиљана; Седмак, Aлександар; Танасић, Иван; Мисковић, Жарко;
dc.citation.volume2
dc.citation.spage1260
dc.citation.epage1265
dc.citation.other2: 1260-1265
dc.identifier.wos000387976801041
dc.identifier.doi10.1016/j.prostr.2016.06.161
dc.identifier.scopus2-s2.0-85041730255
dc.identifier.fulltexthttps://smile.stomf.bg.ac.rs/bitstream/id/727/2108.pdf
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу