SMILE – Repository of the Faculty of Dental Medicine
University of Belgrade - Faculty of Dental Medicine
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites

Authorized Users Only
2016
Authors
Miletić, Vesna
Perić, Dejan
Milošević, Miloš
Manojlović, Dragica
Mitrović, Nenad
Article (Published version)
Metadata
Show full item record
Abstract
Objective. To compare strain and displacement of sculptable bulk-fill, low-shrinkage and conventional composites as well as dye penetration along the dentin-restoration interface. Methods. Modified Class II cavities (N= 5/group) were filled with sculptable bulk-fill (Filtek Bulk Fill Posterior, 3M ESPE; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; fiber-reinforced EverX Posterior, GC; giomer Beautifil Bulk, Schofu), low-shrinkage (Kalore, GC), nanohybrid (Tetric EvoCeram, Ivoclar Vivadent) or microhybrid (Filtek Z250, 3M ESPE) composites. Strain and displacement were determined using the 3D digital image correlation method based on two cameras with 1 mu m displacement sensitivity and 1600 x 1200 pixel resolution (Aramis, GOM). Microleakage along dentin axial and gingival cavity walls was measured under a stereomicroscope using a different set of teeth (N = 8/group). Data were analyzed using analyses of variance with Tukey's post-test, Pearson correlation and paired t-test (alpha = 0.05...). Results. Strain of TEC Bulk, Filtek Bulk, Beautifil Bulk and Kalore was in the range of 1-1.5%. EverX and control composites showed 1.5-2% strain. Axial displacements were between 5 mu m and 30 mu m The least strain was identified at 2 mm below the occlusal surface in 4-mm but not in 2-mm layered composites. Greater microleakage occurred along the gingival than axial wall (p lt 0.05). No correlation was found between strain/displacements and microleakage axially (r(2) = 0.082, p = 0.821; r(2) =-0.2, p = 0.605, respectively) or gingivally (r(2) =-0.126, p = 0.729, r(2) =-0.278, p = 0.469, respectively). Significance. Strain i.e. volumetric shrinkage of sculptable bulk-fill and low-shrinkage composites was comparable to control composites but strain distribution across restoration depth differed. Marginal integrity was more compromised along the gingival than axial dentin wall.

Keywords:
Bulk-fill / Low-shrinkage / Giomer / Composites / Shrinkage / Microleakage
Source:
Dental Materials, 2016, 32, 11, 1441-1451
Publisher:
  • Elsevier Sci Ltd, Oxford
Funding / projects:
  • Development and Application of Methods and Materials for Monitoring New Organic Contaminants, Toxic Compounds and Heavy Metals (RS-172007)
  • Developed new methods for diagnosis and examination mechanical structures (RS-35040)

DOI: 10.1016/j.dental.2016.09.011

ISSN: 0109-5641

PubMed: 27686259

WoS: 000389516300018

Scopus: 2-s2.0-84994482415
[ Google Scholar ]
33
23
URI
https://smile.stomf.bg.ac.rs/handle/123456789/2118
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Miletić, Vesna
AU  - Perić, Dejan
AU  - Milošević, Miloš
AU  - Manojlović, Dragica
AU  - Mitrović, Nenad
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2118
AB  - Objective. To compare strain and displacement of sculptable bulk-fill, low-shrinkage and conventional composites as well as dye penetration along the dentin-restoration interface. Methods. Modified Class II cavities (N= 5/group) were filled with sculptable bulk-fill (Filtek Bulk Fill Posterior, 3M ESPE; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; fiber-reinforced EverX Posterior, GC; giomer Beautifil Bulk, Schofu), low-shrinkage (Kalore, GC), nanohybrid (Tetric EvoCeram, Ivoclar Vivadent) or microhybrid (Filtek Z250, 3M ESPE) composites. Strain and displacement were determined using the 3D digital image correlation method based on two cameras with 1 mu m displacement sensitivity and 1600 x 1200 pixel resolution (Aramis, GOM). Microleakage along dentin axial and gingival cavity walls was measured under a stereomicroscope using a different set of teeth (N = 8/group). Data were analyzed using analyses of variance with Tukey's post-test, Pearson correlation and paired t-test (alpha = 0.05). Results. Strain of TEC Bulk, Filtek Bulk, Beautifil Bulk and Kalore was in the range of 1-1.5%. EverX and control composites showed 1.5-2% strain. Axial displacements were between 5 mu m and 30 mu m The least strain was identified at 2 mm below the occlusal surface in 4-mm but not in 2-mm layered composites. Greater microleakage occurred along the gingival than axial wall (p  lt  0.05). No correlation was found between strain/displacements and microleakage axially (r(2) = 0.082, p = 0.821; r(2) =-0.2, p = 0.605, respectively) or gingivally (r(2) =-0.126, p = 0.729, r(2) =-0.278, p = 0.469, respectively). Significance. Strain i.e. volumetric shrinkage of sculptable bulk-fill and low-shrinkage composites was comparable to control composites but strain distribution across restoration depth differed. Marginal integrity was more compromised along the gingival than axial dentin wall.
PB  - Elsevier Sci Ltd, Oxford
T2  - Dental Materials
T1  - Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites
VL  - 32
IS  - 11
SP  - 1441
EP  - 1451
DO  - 10.1016/j.dental.2016.09.011
ER  - 
@article{
author = "Miletić, Vesna and Perić, Dejan and Milošević, Miloš and Manojlović, Dragica and Mitrović, Nenad",
year = "2016",
abstract = "Objective. To compare strain and displacement of sculptable bulk-fill, low-shrinkage and conventional composites as well as dye penetration along the dentin-restoration interface. Methods. Modified Class II cavities (N= 5/group) were filled with sculptable bulk-fill (Filtek Bulk Fill Posterior, 3M ESPE; Tetric EvoCeram Bulk Fill, Ivoclar Vivadent; fiber-reinforced EverX Posterior, GC; giomer Beautifil Bulk, Schofu), low-shrinkage (Kalore, GC), nanohybrid (Tetric EvoCeram, Ivoclar Vivadent) or microhybrid (Filtek Z250, 3M ESPE) composites. Strain and displacement were determined using the 3D digital image correlation method based on two cameras with 1 mu m displacement sensitivity and 1600 x 1200 pixel resolution (Aramis, GOM). Microleakage along dentin axial and gingival cavity walls was measured under a stereomicroscope using a different set of teeth (N = 8/group). Data were analyzed using analyses of variance with Tukey's post-test, Pearson correlation and paired t-test (alpha = 0.05). Results. Strain of TEC Bulk, Filtek Bulk, Beautifil Bulk and Kalore was in the range of 1-1.5%. EverX and control composites showed 1.5-2% strain. Axial displacements were between 5 mu m and 30 mu m The least strain was identified at 2 mm below the occlusal surface in 4-mm but not in 2-mm layered composites. Greater microleakage occurred along the gingival than axial wall (p  lt  0.05). No correlation was found between strain/displacements and microleakage axially (r(2) = 0.082, p = 0.821; r(2) =-0.2, p = 0.605, respectively) or gingivally (r(2) =-0.126, p = 0.729, r(2) =-0.278, p = 0.469, respectively). Significance. Strain i.e. volumetric shrinkage of sculptable bulk-fill and low-shrinkage composites was comparable to control composites but strain distribution across restoration depth differed. Marginal integrity was more compromised along the gingival than axial dentin wall.",
publisher = "Elsevier Sci Ltd, Oxford",
journal = "Dental Materials",
title = "Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites",
volume = "32",
number = "11",
pages = "1441-1451",
doi = "10.1016/j.dental.2016.09.011"
}
Miletić, V., Perić, D., Milošević, M., Manojlović, D.,& Mitrović, N.. (2016). Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites. in Dental Materials
Elsevier Sci Ltd, Oxford., 32(11), 1441-1451.
https://doi.org/10.1016/j.dental.2016.09.011
Miletić V, Perić D, Milošević M, Manojlović D, Mitrović N. Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites. in Dental Materials. 2016;32(11):1441-1451.
doi:10.1016/j.dental.2016.09.011 .
Miletić, Vesna, Perić, Dejan, Milošević, Miloš, Manojlović, Dragica, Mitrović, Nenad, "Local deformation fields and marginal integrity of sculptable bulk-fill, low-shrinkage and conventional composites" in Dental Materials, 32, no. 11 (2016):1441-1451,
https://doi.org/10.1016/j.dental.2016.09.011 . .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB