SMILE – Repository of the Faculty of Dental Medicine
University of Belgrade - Faculty of Dental Medicine
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effects of a low-Shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on curing efficiency and mechanical properties of experimental resin-based composites

Authorized Users Only
2016
Authors
Manojlović, Dragica
Dramićanin, Miroslav D.
Milošević, Miloš
Zeković, Ivana
Cvijović-Alagić, Ivana
Mitrović, Nenad
Miletić, Vesna
Article (Published version)
Metadata
Show full item record
Abstract
This study investigated the degree of conversion, depth of cure, Vickers hardness, flexural strength, flexural modulus and volumetric shrinkage of experimental composite containing a low shrinkage monomer FIT-852 (FIT; Esstech Inc.) and photoinitiator 2,4,6-trimethylbenzoyldiphenylphosphine oxide (TPO; Sigma Aldrich) compared to conventional composite containing Bisphenol A-glycidyl methacrylate (BisGMA) and camphorquinone-amine photoinitiator system. The degree of conversion was generally higher in FIT-based composites (45-64% range) than in BisGMA-based composites (34-58% range). Vickers hardness, flexural strength and modulus were higher in BisGMA-based composites. A polywave light-curing unit was generally more efficient in terms of conversion and hardness of experimental composites than a monowave unit. FIT-based composite containing TPO showed the depth of cure below 2 mm irrespective of the curing light. The depth of cure of FIT-based composite containing CQ and BisGMA-based com...posites with either photoinitiator was in the range of 2.8-3.0 mm. Volumetric shrinkage of FIT-based composite (0.9-5.7% range) was lower than that of BisGMA-based composite (2.2-12% range). FIT may be used as a shrinkage reducing monomer compatible with the conventional CQ-amine system as well as the alternative TPO photoinitiator. However, the depth of cure of FIT_TPO composite requires boosting to achieve clinically recommended thickness of 2 mm.

Keywords:
Composite / Dimethacrylate / Low shrinkage monomer / Degree of conversion / Mechanical properties / Lucirin TPO
Source:
Materials Science & Engineering C - Materials for Biological Applications, 2016, 58, 487-494
Publisher:
  • Elsevier, Amsterdam
Funding / projects:
  • Development and Application of Methods and Materials for Monitoring New Organic Contaminants, Toxic Compounds and Heavy Metals (RS-172007)

DOI: 10.1016/j.msec.2015.08.054

ISSN: 0928-4931

PubMed: 26478336

WoS: 000364247500057

Scopus: 2-s2.0-84941353433
[ Google Scholar ]
27
20
URI
https://smile.stomf.bg.ac.rs/handle/123456789/2132
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Manojlović, Dragica
AU  - Dramićanin, Miroslav D.
AU  - Milošević, Miloš
AU  - Zeković, Ivana
AU  - Cvijović-Alagić, Ivana
AU  - Mitrović, Nenad
AU  - Miletić, Vesna
PY  - 2016
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2132
AB  - This study investigated the degree of conversion, depth of cure, Vickers hardness, flexural strength, flexural modulus and volumetric shrinkage of experimental composite containing a low shrinkage monomer FIT-852 (FIT; Esstech Inc.) and photoinitiator 2,4,6-trimethylbenzoyldiphenylphosphine oxide (TPO; Sigma Aldrich) compared to conventional composite containing Bisphenol A-glycidyl methacrylate (BisGMA) and camphorquinone-amine photoinitiator system. The degree of conversion was generally higher in FIT-based composites (45-64% range) than in BisGMA-based composites (34-58% range). Vickers hardness, flexural strength and modulus were higher in BisGMA-based composites. A polywave light-curing unit was generally more efficient in terms of conversion and hardness of experimental composites than a monowave unit. FIT-based composite containing TPO showed the depth of cure below 2 mm irrespective of the curing light. The depth of cure of FIT-based composite containing CQ and BisGMA-based composites with either photoinitiator was in the range of 2.8-3.0 mm. Volumetric shrinkage of FIT-based composite (0.9-5.7% range) was lower than that of BisGMA-based composite (2.2-12% range). FIT may be used as a shrinkage reducing monomer compatible with the conventional CQ-amine system as well as the alternative TPO photoinitiator. However, the depth of cure of FIT_TPO composite requires boosting to achieve clinically recommended thickness of 2 mm.
PB  - Elsevier, Amsterdam
T2  - Materials Science & Engineering C - Materials for Biological Applications
T1  - Effects of a low-Shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on curing efficiency and mechanical properties of experimental resin-based composites
VL  - 58
SP  - 487
EP  - 494
DO  - 10.1016/j.msec.2015.08.054
ER  - 
@article{
author = "Manojlović, Dragica and Dramićanin, Miroslav D. and Milošević, Miloš and Zeković, Ivana and Cvijović-Alagić, Ivana and Mitrović, Nenad and Miletić, Vesna",
year = "2016",
abstract = "This study investigated the degree of conversion, depth of cure, Vickers hardness, flexural strength, flexural modulus and volumetric shrinkage of experimental composite containing a low shrinkage monomer FIT-852 (FIT; Esstech Inc.) and photoinitiator 2,4,6-trimethylbenzoyldiphenylphosphine oxide (TPO; Sigma Aldrich) compared to conventional composite containing Bisphenol A-glycidyl methacrylate (BisGMA) and camphorquinone-amine photoinitiator system. The degree of conversion was generally higher in FIT-based composites (45-64% range) than in BisGMA-based composites (34-58% range). Vickers hardness, flexural strength and modulus were higher in BisGMA-based composites. A polywave light-curing unit was generally more efficient in terms of conversion and hardness of experimental composites than a monowave unit. FIT-based composite containing TPO showed the depth of cure below 2 mm irrespective of the curing light. The depth of cure of FIT-based composite containing CQ and BisGMA-based composites with either photoinitiator was in the range of 2.8-3.0 mm. Volumetric shrinkage of FIT-based composite (0.9-5.7% range) was lower than that of BisGMA-based composite (2.2-12% range). FIT may be used as a shrinkage reducing monomer compatible with the conventional CQ-amine system as well as the alternative TPO photoinitiator. However, the depth of cure of FIT_TPO composite requires boosting to achieve clinically recommended thickness of 2 mm.",
publisher = "Elsevier, Amsterdam",
journal = "Materials Science & Engineering C - Materials for Biological Applications",
title = "Effects of a low-Shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on curing efficiency and mechanical properties of experimental resin-based composites",
volume = "58",
pages = "487-494",
doi = "10.1016/j.msec.2015.08.054"
}
Manojlović, D., Dramićanin, M. D., Milošević, M., Zeković, I., Cvijović-Alagić, I., Mitrović, N.,& Miletić, V.. (2016). Effects of a low-Shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on curing efficiency and mechanical properties of experimental resin-based composites. in Materials Science & Engineering C - Materials for Biological Applications
Elsevier, Amsterdam., 58, 487-494.
https://doi.org/10.1016/j.msec.2015.08.054
Manojlović D, Dramićanin MD, Milošević M, Zeković I, Cvijović-Alagić I, Mitrović N, Miletić V. Effects of a low-Shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on curing efficiency and mechanical properties of experimental resin-based composites. in Materials Science & Engineering C - Materials for Biological Applications. 2016;58:487-494.
doi:10.1016/j.msec.2015.08.054 .
Manojlović, Dragica, Dramićanin, Miroslav D., Milošević, Miloš, Zeković, Ivana, Cvijović-Alagić, Ivana, Mitrović, Nenad, Miletić, Vesna, "Effects of a low-Shrinkage methacrylate monomer and monoacylphosphine oxide photoinitiator on curing efficiency and mechanical properties of experimental resin-based composites" in Materials Science & Engineering C - Materials for Biological Applications, 58 (2016):487-494,
https://doi.org/10.1016/j.msec.2015.08.054 . .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB