SMILE – Repository of the Faculty of Dental Medicine
University of Belgrade - Faculty of Dental Medicine
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Assessment of bone vascularity in the posterior maxilla during dental implant insertion by laser Doppler flowmetry.

No Thumbnail
Authors
Vasović, Miroslav
Todorović, Vladimir S.
Kršljak, Elena
Kanjevac, Tatjana
Koković, Vladimir
Article (Published version)
Metadata
Show full item record
Abstract
Bone quality is an important factor that may determine implant success. In addition to the other parameters that define bone quality, vascularity plays a vital role in the process of osseointegration of dental implants. Laser Doppler flowmetry (LDF) is an appropriate method for assessment of tissue vascularity at the level of microcirculation. It is non-invasive, painless and well accepted by the patients. The results are expressed in Perfusion Units (PU). The aim of this study was to estimate bone vascularity in the human posterior maxilla during implant insertion using LDF. Nine patients, three females and six males, mean age 57.56 +/- 8.83 years, consecutively treated with 54 implants were enrolled in this study. Implants were inserted in the posterior maxilla, in positions of first premolar, second premolar and first molar bilaterally in each patient. After implant site preparation with a drill of diameter 2.8 mm, bone vascularity was measured using LDF. Mean LDF value for 54 osteo...tomy sites was 43.39 +/- 14.65 PU. Results of the present study showed there wasn't statistically significant difference in LDF values between implant site positions and genders. It was also revealed that the proximity from the apical part of the implant site to the maxillary sinus floor had no influence on LDF values. Therefore, bone vascularity in the posterior maxilla could be measured by LDF during implant insertion, and those results might be considered as a standard data for this part of the upper jaw.

Keywords:
Bone vascularity / Posterior maxilla / Dental implants / Laser Doppler flowmetry
Source:
Biomedical Research - India, 2017, 28, 9, 4228-4232
Publisher:
  • Scientific Publishers India, Aligarh

ISSN: 0970-938X

WoS: 000403460100080

[ Google Scholar ]
1
Handle
https://hdl.handle.net/21.15107/rcub_smile_2188
URI
https://smile.stomf.bg.ac.rs/handle/123456789/2188
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Vasović, Miroslav
AU  - Todorović, Vladimir S.
AU  - Kršljak, Elena
AU  - Kanjevac, Tatjana
AU  - Koković, Vladimir
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2188
AB  - Bone quality is an important factor that may determine implant success. In addition to the other parameters that define bone quality, vascularity plays a vital role in the process of osseointegration of dental implants. Laser Doppler flowmetry (LDF) is an appropriate method for assessment of tissue vascularity at the level of microcirculation. It is non-invasive, painless and well accepted by the patients. The results are expressed in Perfusion Units (PU). The aim of this study was to estimate bone vascularity in the human posterior maxilla during implant insertion using LDF. Nine patients, three females and six males, mean age 57.56 +/- 8.83 years, consecutively treated with 54 implants were enrolled in this study. Implants were inserted in the posterior maxilla, in positions of first premolar, second premolar and first molar bilaterally in each patient. After implant site preparation with a drill of diameter 2.8 mm, bone vascularity was measured using LDF. Mean LDF value for 54 osteotomy sites was 43.39 +/- 14.65 PU. Results of the present study showed there wasn't statistically significant difference in LDF values between implant site positions and genders. It was also revealed that the proximity from the apical part of the implant site to the maxillary sinus floor had no influence on LDF values. Therefore, bone vascularity in the posterior maxilla could be measured by LDF during implant insertion, and those results might be considered as a standard data for this part of the upper jaw.
PB  - Scientific Publishers India, Aligarh
T2  - Biomedical Research - India
T1  - Assessment of bone vascularity in the posterior maxilla during dental implant insertion by laser Doppler flowmetry.
VL  - 28
IS  - 9
SP  - 4228
EP  - 4232
UR  - https://hdl.handle.net/21.15107/rcub_smile_2188
ER  - 
@article{
author = "Vasović, Miroslav and Todorović, Vladimir S. and Kršljak, Elena and Kanjevac, Tatjana and Koković, Vladimir",
year = "2017",
abstract = "Bone quality is an important factor that may determine implant success. In addition to the other parameters that define bone quality, vascularity plays a vital role in the process of osseointegration of dental implants. Laser Doppler flowmetry (LDF) is an appropriate method for assessment of tissue vascularity at the level of microcirculation. It is non-invasive, painless and well accepted by the patients. The results are expressed in Perfusion Units (PU). The aim of this study was to estimate bone vascularity in the human posterior maxilla during implant insertion using LDF. Nine patients, three females and six males, mean age 57.56 +/- 8.83 years, consecutively treated with 54 implants were enrolled in this study. Implants were inserted in the posterior maxilla, in positions of first premolar, second premolar and first molar bilaterally in each patient. After implant site preparation with a drill of diameter 2.8 mm, bone vascularity was measured using LDF. Mean LDF value for 54 osteotomy sites was 43.39 +/- 14.65 PU. Results of the present study showed there wasn't statistically significant difference in LDF values between implant site positions and genders. It was also revealed that the proximity from the apical part of the implant site to the maxillary sinus floor had no influence on LDF values. Therefore, bone vascularity in the posterior maxilla could be measured by LDF during implant insertion, and those results might be considered as a standard data for this part of the upper jaw.",
publisher = "Scientific Publishers India, Aligarh",
journal = "Biomedical Research - India",
title = "Assessment of bone vascularity in the posterior maxilla during dental implant insertion by laser Doppler flowmetry.",
volume = "28",
number = "9",
pages = "4228-4232",
url = "https://hdl.handle.net/21.15107/rcub_smile_2188"
}
Vasović, M., Todorović, V. S., Kršljak, E., Kanjevac, T.,& Koković, V.. (2017). Assessment of bone vascularity in the posterior maxilla during dental implant insertion by laser Doppler flowmetry.. in Biomedical Research - India
Scientific Publishers India, Aligarh., 28(9), 4228-4232.
https://hdl.handle.net/21.15107/rcub_smile_2188
Vasović M, Todorović VS, Kršljak E, Kanjevac T, Koković V. Assessment of bone vascularity in the posterior maxilla during dental implant insertion by laser Doppler flowmetry.. in Biomedical Research - India. 2017;28(9):4228-4232.
https://hdl.handle.net/21.15107/rcub_smile_2188 .
Vasović, Miroslav, Todorović, Vladimir S., Kršljak, Elena, Kanjevac, Tatjana, Koković, Vladimir, "Assessment of bone vascularity in the posterior maxilla during dental implant insertion by laser Doppler flowmetry." in Biomedical Research - India, 28, no. 9 (2017):4228-4232,
https://hdl.handle.net/21.15107/rcub_smile_2188 .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB