SMILE – Repository of the Faculty of Dental Medicine
University of Belgrade - Faculty of Dental Medicine
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Curing characteristics of flowable and sculptable bulk-fill composites

Authorized Users Only
2017
Authors
Miletić, Vesna
Pongprueksa, Pong
de Munck, Jan
Brooks, Neil R.
Van Meerbeek, Bart
Article (Published version)
Metadata
Show full item record
Abstract
The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (alpha = 0.05). DC and VH ranged between 40-70 % and ...30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.

Keywords:
Bulk-fill / Composites / Translucency / Depth of cure / Degree of conversion / Hardness
Source:
Clinical Oral Investigations, 2017, 21, 4, 1201-1212
Publisher:
  • Springer Heidelberg, Heidelberg
Funding / projects:
  • CEDIADR
  • Research Foundation-Flanders (FWO)FWO [G.0496.10]
  • Development and Application of Methods and Materials for Monitoring New Organic Contaminants, Toxic Compounds and Heavy Metals (RS-172007)

DOI: 10.1007/s00784-016-1894-0

ISSN: 1432-6981

PubMed: 27383375

WoS: 000399888600028

Scopus: 2-s2.0-84978160930
[ Google Scholar ]
45
33
URI
https://smile.stomf.bg.ac.rs/handle/123456789/2191
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Miletić, Vesna
AU  - Pongprueksa, Pong
AU  - de Munck, Jan
AU  - Brooks, Neil R.
AU  - Van Meerbeek, Bart
PY  - 2017
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2191
AB  - The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (alpha = 0.05). DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.
PB  - Springer Heidelberg, Heidelberg
T2  - Clinical Oral Investigations
T1  - Curing characteristics of flowable and sculptable bulk-fill composites
VL  - 21
IS  - 4
SP  - 1201
EP  - 1212
DO  - 10.1007/s00784-016-1894-0
ER  - 
@article{
author = "Miletić, Vesna and Pongprueksa, Pong and de Munck, Jan and Brooks, Neil R. and Van Meerbeek, Bart",
year = "2017",
abstract = "The aim of this study was to determine and correlate the degree of conversion (DC) with Vickers hardness (VH) and translucency parameter (TP) with the depth of cure (DoC) of five bulk-fill composites. Six specimens per group, consisting of Tetric EvoCeram Bulk Fill ("TEC Bulk," Ivoclar Vivadent), SonicFill (Kerr), SDR Smart Dentin Replacement ("SDR," Dentsply), Xenius base ("Xenius," StickTech; commercialized as EverX Posterior, GC), Filtek Bulk Fill flowable ("Filtek Bulk," 3M ESPE), and Tetric EvoCeram ("TEC," control), were prepared for DC and VH: two 2-mm-thick layers, each light-cured for 10 s; one 4-mm bulk-fill, light-cured for 10 or 20 s; and one 6-mm bulk-fill, cured for 20 s. DC was measured using a Fourier-transform infrared spectrometer, VH using a Vickers hardness tester. DoC and TP were measured using an acetone-shaking test and a spectrophotometer, respectively. Data were analyzed using ANOVA and Pearson's correlation (alpha = 0.05). DC and VH ranged between 40-70 % and 30-80 VHN, respectively. TEC Bulk, Xenius, and SonicFill, bulk-filled as 4-mm-thick specimens, showed bottom-to-top hardness ratios above 80 % after 20 s curing. A positive linear correlation was found for bottom DC and VH. An average DC ratio of 0.9 corresponded to a bottom-to-top VH ratio of 0.8. Sculptable bulk-fills require 20 s, whereas 10 s curing time was sufficient for flowable bulk-fills using a high-intensity LED unit. Clinicians should be aware that longer curing times may be required for sculptable than flowable bulk-fill composites in order to achieve optimal curing characteristics.",
publisher = "Springer Heidelberg, Heidelberg",
journal = "Clinical Oral Investigations",
title = "Curing characteristics of flowable and sculptable bulk-fill composites",
volume = "21",
number = "4",
pages = "1201-1212",
doi = "10.1007/s00784-016-1894-0"
}
Miletić, V., Pongprueksa, P., de Munck, J., Brooks, N. R.,& Van Meerbeek, B.. (2017). Curing characteristics of flowable and sculptable bulk-fill composites. in Clinical Oral Investigations
Springer Heidelberg, Heidelberg., 21(4), 1201-1212.
https://doi.org/10.1007/s00784-016-1894-0
Miletić V, Pongprueksa P, de Munck J, Brooks NR, Van Meerbeek B. Curing characteristics of flowable and sculptable bulk-fill composites. in Clinical Oral Investigations. 2017;21(4):1201-1212.
doi:10.1007/s00784-016-1894-0 .
Miletić, Vesna, Pongprueksa, Pong, de Munck, Jan, Brooks, Neil R., Van Meerbeek, Bart, "Curing characteristics of flowable and sculptable bulk-fill composites" in Clinical Oral Investigations, 21, no. 4 (2017):1201-1212,
https://doi.org/10.1007/s00784-016-1894-0 . .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB