Приказ основних података о документу

dc.creatorLepojević, Nikola
dc.creatorŠćepan, Ivana
dc.creatorGlišić, Branislav
dc.creatorJenko, Monika
dc.creatorGodec, Matjaz
dc.creatorHocevar, Samo
dc.creatorRudolf, Rebeka
dc.date.accessioned2020-07-02T13:21:07Z
dc.date.available2020-07-02T13:21:07Z
dc.date.issued2019
dc.identifier.issn2079-6412
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/2375
dc.description.abstractNickel-titanium (NiTi) orthodontic archwires are crucial in the initial stages of orthodontic therapy when the movement of teeth and deflection of the archwire are the largest. Their great mechanical properties come with their main disadvantage-the leakage of nickel. Various in vitro studies measured nickel leakage from archwires that were only immersed in the medium with little or minimal simulation of all stress and deflection forces that affect them. This study aims to overcome that by simulating deflection forces that those archwires are exposed to inside the mouth of a patient. NiTi orthodontic archwires were immersed in CACO2-2 cell culture medium and then immediately loaded while using a simulator of multiaxial stress for 24 h. After the experiment, the surface of the NiTi orthodontic archwires were analysed while using scanning electron microscopy (SEM) and auger electron spectroscopy (AES). The observations showed significant microstructural and compositional changes within the first 51 nm thickness of the archwire surface. Furthermore, the released nickel and titanium concentrations in the CACO2-2 cell culture medium were measured while using Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). It was found out that the level of released nickel ions was 1.310 mu g/L, which can be assigned as statistically significant results. These data represent the first mention of the already detectable release of Ni ions after 24 h during the simulation of mechanical loading in the CACO2-2 cell culture medium, which is important for clinical orthodontic praxis.en
dc.publisherMdpi, Basel
dc.relationSlovenian Research Agency ARRS (Infrastructure program University of Maribor) [I0-0029]
dc.relationEureka program ORTO-NITI [E!6788]
dc.relationMinistry of Education, Science and Technological Development Republic of Serbia
dc.rightsopenAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.sourceCoatings
dc.subjectnickel-titaniumen
dc.subjectorthodontic archwiresen
dc.subjectsurfaceen
dc.subjectsimulationen
dc.subjectmechanical loadingen
dc.subjectCACO2-2 cell culture mediumen
dc.subjectscanning electron microscopy (SEM)en
dc.subjectauger electron spectroscopy (AES)en
dc.subjectinductively coupled plasma mass spectroscopy (ICP-MS)en
dc.titleCharacterisation of NiTi Orthodontic Archwires Surface after the Simulation of Mechanical Loading in CACO2-2 Cell Cultureen
dc.typearticle
dc.rights.licenseBY
dcterms.abstractГодец, Матјаз; Шћепан, Ивана; Глишић, Бранислав; Лепојевић, Никола; Рудолф, Ребека; Јенко, Моника; Хоцевар, Само;
dc.citation.volume9
dc.citation.issue7
dc.citation.other9(7): -
dc.citation.rankM22
dc.identifier.wos000478656200026
dc.identifier.doi10.3390/coatings9070440
dc.identifier.scopus2-s2.0-85069983489
dc.identifier.fulltexthttps://smile.stomf.bg.ac.rs/bitstream/id/920/2370.pdf
dc.type.versionpublishedVersion


Документи

Thumbnail

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу