SMILE – Repository of the Faculty of Dental Medicine
University of Belgrade - Faculty of Dental Medicine
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Color stability of bulk-fill and universal composite restorations with dissimilar dentin replacement materials

Authorized Users Only
2019
Authors
Miletić, Vesna
Marjanović, Jovana
Veljović, Đorđe
Stasić, Jovana
Petrović, Violeta
Article (Published version)
Metadata
Show full item record
Abstract
Objective To determine color changes in bulk-fill composite and universal composite restorations with dissimilar dentin replacement materials in extracted teeth after staining in red wine. Materials and Methods Cylindrical, 4 mm deep, class I cavities were prepared in 140 human molars. Bottom 2 mm was restored with Biodentine (Septodont), everX posterior (GC) or experimental HAP inserts. Each dentin replacement material was covered with a 2-mm layer of a universal composite Filtek Z250 or Z550 (3M ESPE) or Gradia Posterior (GC). Groups combining top composite layer and the underlying dentin replacement were designated as "composite_dentin replacement." Filtek Bulk Fill (3M ESPE) and Tetric EvoCeram Bulk Fill (Ivoclar Vivadent) were placed as a single 4-mm layer. Color measurements were performed using Vita Easyshade 4.0 (Vita Zahnfabrik) initially and after 48-hours storage in red wine at 37 degrees C. Results Color differences (Delta E-oo) ranged between 2.1 +/- 0.7 (Z250_HAP) and 7.8... +/- 1.1 (Z550_everX). EverX resulted in higher Delta E-oo of the overlying composite than HAP (P lt .001) and Biodentine (P = .006). Generally, Delta E-oo was affected more by decreasing lightness (Delta L ') than changes in chroma (Delta C '). Conclusions EverX resulted in higher Delta E-oo of the restoration than Biodentine and experimental HAP after staining in red wine. No significant differences in Delta E-oo may be expected in different composites with the same underlying dentin replacement material. The same was generally true for bulk-fill and universal composites. Clinical Significance Similar extent of color changes may be expected in bulk-fill and universal composites. Highly translucent everX might exhibit greater color differences irrespective of the capping composite than non-translucent materials. Clinicians have a wider choice of composite materials to cover a particular dentin replacement material, for example, everX or Biodentine, as similar color differences may be expected in various overlying composite brands.

Keywords:
Biodentine / bulk-fill / color / composite / hydroxyapatite / universal
Source:
Journal of Esthetic & Restorative Dentistry, 2019, 31, 5, 520-528
Publisher:
  • Wiley, Hoboken
Funding / projects:
  • Synthesis, processing and applications of nanostructured multifunctional materials with defined properties (RS-45019)
  • Development and Application of Methods and Materials for Monitoring New Organic Contaminants, Toxic Compounds and Heavy Metals (RS-172007)

DOI: 10.1111/jerd.12529

ISSN: 1496-4155

PubMed: 31580013

WoS: 000488632900001

Scopus: 2-s2.0-85072994171
[ Google Scholar ]
9
2
URI
https://smile.stomf.bg.ac.rs/handle/123456789/2378
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Miletić, Vesna
AU  - Marjanović, Jovana
AU  - Veljović, Đorđe
AU  - Stasić, Jovana
AU  - Petrović, Violeta
PY  - 2019
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/2378
AB  - Objective To determine color changes in bulk-fill composite and universal composite restorations with dissimilar dentin replacement materials in extracted teeth after staining in red wine. Materials and Methods Cylindrical, 4 mm deep, class I cavities were prepared in 140 human molars. Bottom 2 mm was restored with Biodentine (Septodont), everX posterior (GC) or experimental HAP inserts. Each dentin replacement material was covered with a 2-mm layer of a universal composite Filtek Z250 or Z550 (3M ESPE) or Gradia Posterior (GC). Groups combining top composite layer and the underlying dentin replacement were designated as "composite_dentin replacement." Filtek Bulk Fill (3M ESPE) and Tetric EvoCeram Bulk Fill (Ivoclar Vivadent) were placed as a single 4-mm layer. Color measurements were performed using Vita Easyshade 4.0 (Vita Zahnfabrik) initially and after 48-hours storage in red wine at 37 degrees C. Results Color differences (Delta E-oo) ranged between 2.1 +/- 0.7 (Z250_HAP) and 7.8 +/- 1.1 (Z550_everX). EverX resulted in higher Delta E-oo of the overlying composite than HAP (P  lt  .001) and Biodentine (P = .006). Generally, Delta E-oo was affected more by decreasing lightness (Delta L ') than changes in chroma (Delta C '). Conclusions EverX resulted in higher Delta E-oo of the restoration than Biodentine and experimental HAP after staining in red wine. No significant differences in Delta E-oo may be expected in different composites with the same underlying dentin replacement material. The same was generally true for bulk-fill and universal composites. Clinical Significance Similar extent of color changes may be expected in bulk-fill and universal composites. Highly translucent everX might exhibit greater color differences irrespective of the capping composite than non-translucent materials. Clinicians have a wider choice of composite materials to cover a particular dentin replacement material, for example, everX or Biodentine, as similar color differences may be expected in various overlying composite brands.
PB  - Wiley, Hoboken
T2  - Journal of Esthetic & Restorative Dentistry
T1  - Color stability of bulk-fill and universal composite restorations with dissimilar dentin replacement materials
VL  - 31
IS  - 5
SP  - 520
EP  - 528
DO  - 10.1111/jerd.12529
ER  - 
@article{
author = "Miletić, Vesna and Marjanović, Jovana and Veljović, Đorđe and Stasić, Jovana and Petrović, Violeta",
year = "2019",
abstract = "Objective To determine color changes in bulk-fill composite and universal composite restorations with dissimilar dentin replacement materials in extracted teeth after staining in red wine. Materials and Methods Cylindrical, 4 mm deep, class I cavities were prepared in 140 human molars. Bottom 2 mm was restored with Biodentine (Septodont), everX posterior (GC) or experimental HAP inserts. Each dentin replacement material was covered with a 2-mm layer of a universal composite Filtek Z250 or Z550 (3M ESPE) or Gradia Posterior (GC). Groups combining top composite layer and the underlying dentin replacement were designated as "composite_dentin replacement." Filtek Bulk Fill (3M ESPE) and Tetric EvoCeram Bulk Fill (Ivoclar Vivadent) were placed as a single 4-mm layer. Color measurements were performed using Vita Easyshade 4.0 (Vita Zahnfabrik) initially and after 48-hours storage in red wine at 37 degrees C. Results Color differences (Delta E-oo) ranged between 2.1 +/- 0.7 (Z250_HAP) and 7.8 +/- 1.1 (Z550_everX). EverX resulted in higher Delta E-oo of the overlying composite than HAP (P  lt  .001) and Biodentine (P = .006). Generally, Delta E-oo was affected more by decreasing lightness (Delta L ') than changes in chroma (Delta C '). Conclusions EverX resulted in higher Delta E-oo of the restoration than Biodentine and experimental HAP after staining in red wine. No significant differences in Delta E-oo may be expected in different composites with the same underlying dentin replacement material. The same was generally true for bulk-fill and universal composites. Clinical Significance Similar extent of color changes may be expected in bulk-fill and universal composites. Highly translucent everX might exhibit greater color differences irrespective of the capping composite than non-translucent materials. Clinicians have a wider choice of composite materials to cover a particular dentin replacement material, for example, everX or Biodentine, as similar color differences may be expected in various overlying composite brands.",
publisher = "Wiley, Hoboken",
journal = "Journal of Esthetic & Restorative Dentistry",
title = "Color stability of bulk-fill and universal composite restorations with dissimilar dentin replacement materials",
volume = "31",
number = "5",
pages = "520-528",
doi = "10.1111/jerd.12529"
}
Miletić, V., Marjanović, J., Veljović, Đ., Stasić, J.,& Petrović, V.. (2019). Color stability of bulk-fill and universal composite restorations with dissimilar dentin replacement materials. in Journal of Esthetic & Restorative Dentistry
Wiley, Hoboken., 31(5), 520-528.
https://doi.org/10.1111/jerd.12529
Miletić V, Marjanović J, Veljović Đ, Stasić J, Petrović V. Color stability of bulk-fill and universal composite restorations with dissimilar dentin replacement materials. in Journal of Esthetic & Restorative Dentistry. 2019;31(5):520-528.
doi:10.1111/jerd.12529 .
Miletić, Vesna, Marjanović, Jovana, Veljović, Đorđe, Stasić, Jovana, Petrović, Violeta, "Color stability of bulk-fill and universal composite restorations with dissimilar dentin replacement materials" in Journal of Esthetic & Restorative Dentistry, 31, no. 5 (2019):520-528,
https://doi.org/10.1111/jerd.12529 . .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB