An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling
Samo za registrovane korisnike
2011
Autori
Mišić, TijanaMarković, Aleksa
Todorović, Aleksandar
Čolić, Snježana
Šćepanović, Miodrag
Miličić, Biljana
Članak u časopisu (Objavljena verzija)
Metapodaci
Prikaz svih podataka o dokumentuApstrakt
Objective. The aim of this study was to compare changes in temperature of the surrounding bone at various osteotomy depths during implant site preparation by bone condensing and by bone drilling as well as the dynamics of their change. Study design. In the present "in vitro" study, pig ribs with uniform thickness of cortical bone of 2 mm were used. Lateral bone-condensing (experimental group) and bone-drilling techniques (control group) were performed. Temperature changes were recorded at a distance of 0.5 mm from the final test osteotomy by 3 thermocouples at the depths of 1, 5, and 10 mm in tripod configuration. Data were collected from 48 measurements, 24 for each group. Results. Significantly higher mean temperature increase at the depth of 5 mm was observed during bone drilling compared with bone condensing, whereas for the depths of 1 and 10 mm differences were not significant between the 2 surgical techniques. During bone condensing, the mean temperature rise was continuously de...creasing with increasing depth of osteotomies, whereas during bone drilling the mean temperature rise was first increased and reached a peak at the depth of 5 mm and then began to decrease with increasing depth of the osteotomies. Conclusions. The bone-condensing technique applied in the jaw bone class D4 offers an advantage over bone drilling because it generates a significantly smaller amount of heat. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 28-33)
Izvor:
Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology, 2011, 112, 1, 28-33Izdavač:
- Mosby-Elsevier, New York
DOI: 10.1016/j.tripleo.2010.08.010
ISSN: 1079-2104
PubMed: 21147005
WoS: 000291480100018
Scopus: 2-s2.0-79958771094
Kolekcije
Institucija/grupa
Stomatološki fakultetTY - JOUR AU - Mišić, Tijana AU - Marković, Aleksa AU - Todorović, Aleksandar AU - Čolić, Snježana AU - Šćepanović, Miodrag AU - Miličić, Biljana PY - 2011 UR - https://smile.stomf.bg.ac.rs/handle/123456789/1621 AB - Objective. The aim of this study was to compare changes in temperature of the surrounding bone at various osteotomy depths during implant site preparation by bone condensing and by bone drilling as well as the dynamics of their change. Study design. In the present "in vitro" study, pig ribs with uniform thickness of cortical bone of 2 mm were used. Lateral bone-condensing (experimental group) and bone-drilling techniques (control group) were performed. Temperature changes were recorded at a distance of 0.5 mm from the final test osteotomy by 3 thermocouples at the depths of 1, 5, and 10 mm in tripod configuration. Data were collected from 48 measurements, 24 for each group. Results. Significantly higher mean temperature increase at the depth of 5 mm was observed during bone drilling compared with bone condensing, whereas for the depths of 1 and 10 mm differences were not significant between the 2 surgical techniques. During bone condensing, the mean temperature rise was continuously decreasing with increasing depth of osteotomies, whereas during bone drilling the mean temperature rise was first increased and reached a peak at the depth of 5 mm and then began to decrease with increasing depth of the osteotomies. Conclusions. The bone-condensing technique applied in the jaw bone class D4 offers an advantage over bone drilling because it generates a significantly smaller amount of heat. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 28-33) PB - Mosby-Elsevier, New York T2 - Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology T1 - An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling VL - 112 IS - 1 SP - 28 EP - 33 DO - 10.1016/j.tripleo.2010.08.010 ER -
@article{ author = "Mišić, Tijana and Marković, Aleksa and Todorović, Aleksandar and Čolić, Snježana and Šćepanović, Miodrag and Miličić, Biljana", year = "2011", abstract = "Objective. The aim of this study was to compare changes in temperature of the surrounding bone at various osteotomy depths during implant site preparation by bone condensing and by bone drilling as well as the dynamics of their change. Study design. In the present "in vitro" study, pig ribs with uniform thickness of cortical bone of 2 mm were used. Lateral bone-condensing (experimental group) and bone-drilling techniques (control group) were performed. Temperature changes were recorded at a distance of 0.5 mm from the final test osteotomy by 3 thermocouples at the depths of 1, 5, and 10 mm in tripod configuration. Data were collected from 48 measurements, 24 for each group. Results. Significantly higher mean temperature increase at the depth of 5 mm was observed during bone drilling compared with bone condensing, whereas for the depths of 1 and 10 mm differences were not significant between the 2 surgical techniques. During bone condensing, the mean temperature rise was continuously decreasing with increasing depth of osteotomies, whereas during bone drilling the mean temperature rise was first increased and reached a peak at the depth of 5 mm and then began to decrease with increasing depth of the osteotomies. Conclusions. The bone-condensing technique applied in the jaw bone class D4 offers an advantage over bone drilling because it generates a significantly smaller amount of heat. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 28-33)", publisher = "Mosby-Elsevier, New York", journal = "Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology", title = "An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling", volume = "112", number = "1", pages = "28-33", doi = "10.1016/j.tripleo.2010.08.010" }
Mišić, T., Marković, A., Todorović, A., Čolić, S., Šćepanović, M.,& Miličić, B.. (2011). An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling. in Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology Mosby-Elsevier, New York., 112(1), 28-33. https://doi.org/10.1016/j.tripleo.2010.08.010
Mišić T, Marković A, Todorović A, Čolić S, Šćepanović M, Miličić B. An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling. in Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology. 2011;112(1):28-33. doi:10.1016/j.tripleo.2010.08.010 .
Mišić, Tijana, Marković, Aleksa, Todorović, Aleksandar, Čolić, Snježana, Šćepanović, Miodrag, Miličić, Biljana, "An in vitro study of temperature changes in type 4 bone during implant placement: bone condensing versus bone drilling" in Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology & Endodontology, 112, no. 1 (2011):28-33, https://doi.org/10.1016/j.tripleo.2010.08.010 . .