Приказ основних података о документу

dc.creatorAntonijević, Đorđe
dc.creatorJevremović, Danimir
dc.creatorJovanović, Svetlana
dc.creatorObradović-Đuričić, Kosovka
dc.date.accessioned2020-07-02T12:37:30Z
dc.date.available2020-07-02T12:37:30Z
dc.date.issued2012
dc.identifier.issn0033-6572
dc.identifier.urihttps://smile.stomf.bg.ac.rs/handle/123456789/1694
dc.description.abstractObjective: According to the ISO, the radiopacity of luting cements should be equal to or greater than that of aluminum. The aim of this in vitro study was to determine the radiopacity of 13 commercially available dental luting cements and compare them with human enamel and dentin. Method and Materials: Five classes of luting cements were evaluated: zine phosphate (Cegal N and Harvard Zine Phosphate), zine polycarboxylate (Harvard Polycarboxylate and Hoffmann's Carboxylate), glass ionomers (Ketac Cem Fasymix, Ketac Cem Radiopaque, and Fuji I), resin-modified glass ionomer (Rely X Luting), and resin cements (Multilink Automix, Variolink II, Speed CEM, Rely X Unicem Automix, and three shades of Variolink Veneer). Tooth slices served as controls. Five specimens of each material measuring 8 mm in diameter and 1 mm thick were prepared and radiographed alongside tooth slices and an aluminum stepwedge using a Trophy RVG sensor. The radiopacity values were expressed in mm Al and analyzd by the ANOVA and Tukey tests (P lt .05). Results: All the cements examined except Variolink Veneer had significantly higher radiopacities than that of dentin. Rely X Unicem Automix, glass ionomer, and resin-modified glass-ionomer cements demonstrated radiopacities that were not significantly different with respect to enamel. Zinc phosphate, zinc polycarboxylate, and three of the resin cements presented radiopacity values that were significantly greater than that of enamel. Conclusion: Almost all the investigated materials presented an acceptable radiopacity. Radiopacity of dental cements seems to depend more on the presence of elements with high atomic numbers than on the type of the material. (Quintessence Int 2012; 43: 421-428)en
dc.relationinfo:eu-repo/grantAgreement/MESTD/MPN2006-2010/156039/RS//
dc.rightsrestrictedAccess
dc.sourceQuintessence International
dc.subjectdental hard tissueen
dc.subjectdigital radiographyen
dc.subjectluting cementen
dc.subjectradiopacityen
dc.titleAn in vitro radiographic analysis of the density of dental luting cements as measured by CCD-based digital radiographyen
dc.typearticle
dc.rights.licenseARR
dcterms.abstractAнтонијевић, Ђорђе; Обрадовић-Ђуричић, Косовка; Јовановић, Светлана; Јевремовић, Данимир;
dc.citation.volume43
dc.citation.issue5
dc.citation.spage421
dc.citation.epage428
dc.citation.other43(5): 421-428
dc.citation.rankM23
dc.identifier.wos000317581600012
dc.identifier.pmid22536594
dc.identifier.scopus2-s2.0-84871675091
dc.identifier.rcubhttps://hdl.handle.net/21.15107/rcub_smile_1694
dc.type.versionpublishedVersion


Документи

ДатотекеВеличинаФорматПреглед

Уз овај запис нема датотека.

Овај документ се појављује у следећим колекцијама

Приказ основних података о документу