SMILE – Repository of the Faculty of Dental Medicine
University of Belgrade - Faculty of Dental Medicine
    • English
    • Српски
    • Српски (Serbia)
  • English 
    • English
    • Serbian (Cyrillic)
    • Serbian (Latin)
  • Login
View Item 
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
  •   SMILE
  • Stomatološki fakultet
  • Radovi istraživača
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Resonance Frequency Analysis as a Reliable Criterion for Early Loading of Sandblasted/Acid-Etched Active Surface Implants Placed by the Osteotome Sinus Floor Elevation Technique

No Thumbnail
Authors
Marković, Aleksa
Čolić, Snježana
Dražić, Radojica
Gačić, Bojan
Todorović, Aleksandar
Stajčić, Zoran
Article (Published version)
Metadata
Show full item record
Abstract
Purpose: This study was intended to investigate, through resonance frequency analysis (RFA), the stability of implants placed in an early loading protocol via the osteotome sinus floor elevation technique in the posterior maxilla. All implants featured a sandblasted/acid-etched active surface. Materials and Methods: An early loading protocol was considered for patients in whom implants with a sandblasted, large-grit/acid-etched active surface (SLActive) were placed in the posterior maxilla by the osteotome sinus floor elevation technique. Implant stability, which was measured by RFA at surgery and at weekly intervals for the following 6 weeks, was used as the most significant inclusion criterion. At the end of the stability observation period, only implants with a stability quotient of 65 or higher were loaded. Implants were followed for 2 years. Results: Twenty-seven patients received 42 implants, 40 of which were subjected to an early loading protocol 6 weeks after placement. Two yea...rs after loading, all 40 implants were surviving, without clinically or radiographically detectible complications. Conclusion: An early loading protocol can be used for SLActive implants placed in the posterior maxilla via the osteotome sinus floor elevation technique if their stability is confirmed by RFA. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:718-724

Keywords:
dental implants / early loading / implant stability / resonance frequency analysis / sinus floor elevation / surface properties
Source:
International Journal of Oral & Maxillofacial Implants, 2011, 26, 4, 718-724

ISSN: 0882-2786

PubMed: 21841979

WoS: 000294523900003

Scopus: 2-s2.0-84555204375
[ Google Scholar ]
11
10
Handle
https://hdl.handle.net/21.15107/rcub_smile_1626
URI
https://smile.stomf.bg.ac.rs/handle/123456789/1626
Collections
  • Radovi istraživača
Institution/Community
Stomatološki fakultet
TY  - JOUR
AU  - Marković, Aleksa
AU  - Čolić, Snježana
AU  - Dražić, Radojica
AU  - Gačić, Bojan
AU  - Todorović, Aleksandar
AU  - Stajčić, Zoran
PY  - 2011
UR  - https://smile.stomf.bg.ac.rs/handle/123456789/1626
AB  - Purpose: This study was intended to investigate, through resonance frequency analysis (RFA), the stability of implants placed in an early loading protocol via the osteotome sinus floor elevation technique in the posterior maxilla. All implants featured a sandblasted/acid-etched active surface. Materials and Methods: An early loading protocol was considered for patients in whom implants with a sandblasted, large-grit/acid-etched active surface (SLActive) were placed in the posterior maxilla by the osteotome sinus floor elevation technique. Implant stability, which was measured by RFA at surgery and at weekly intervals for the following 6 weeks, was used as the most significant inclusion criterion. At the end of the stability observation period, only implants with a stability quotient of 65 or higher were loaded. Implants were followed for 2 years. Results: Twenty-seven patients received 42 implants, 40 of which were subjected to an early loading protocol 6 weeks after placement. Two years after loading, all 40 implants were surviving, without clinically or radiographically detectible complications. Conclusion: An early loading protocol can be used for SLActive implants placed in the posterior maxilla via the osteotome sinus floor elevation technique if their stability is confirmed by RFA. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:718-724
T2  - International Journal of Oral & Maxillofacial Implants
T1  - Resonance Frequency Analysis as a Reliable Criterion for Early Loading of Sandblasted/Acid-Etched Active Surface Implants Placed by the Osteotome Sinus Floor Elevation Technique
VL  - 26
IS  - 4
SP  - 718
EP  - 724
UR  - https://hdl.handle.net/21.15107/rcub_smile_1626
ER  - 
@article{
author = "Marković, Aleksa and Čolić, Snježana and Dražić, Radojica and Gačić, Bojan and Todorović, Aleksandar and Stajčić, Zoran",
year = "2011",
abstract = "Purpose: This study was intended to investigate, through resonance frequency analysis (RFA), the stability of implants placed in an early loading protocol via the osteotome sinus floor elevation technique in the posterior maxilla. All implants featured a sandblasted/acid-etched active surface. Materials and Methods: An early loading protocol was considered for patients in whom implants with a sandblasted, large-grit/acid-etched active surface (SLActive) were placed in the posterior maxilla by the osteotome sinus floor elevation technique. Implant stability, which was measured by RFA at surgery and at weekly intervals for the following 6 weeks, was used as the most significant inclusion criterion. At the end of the stability observation period, only implants with a stability quotient of 65 or higher were loaded. Implants were followed for 2 years. Results: Twenty-seven patients received 42 implants, 40 of which were subjected to an early loading protocol 6 weeks after placement. Two years after loading, all 40 implants were surviving, without clinically or radiographically detectible complications. Conclusion: An early loading protocol can be used for SLActive implants placed in the posterior maxilla via the osteotome sinus floor elevation technique if their stability is confirmed by RFA. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:718-724",
journal = "International Journal of Oral & Maxillofacial Implants",
title = "Resonance Frequency Analysis as a Reliable Criterion for Early Loading of Sandblasted/Acid-Etched Active Surface Implants Placed by the Osteotome Sinus Floor Elevation Technique",
volume = "26",
number = "4",
pages = "718-724",
url = "https://hdl.handle.net/21.15107/rcub_smile_1626"
}
Marković, A., Čolić, S., Dražić, R., Gačić, B., Todorović, A.,& Stajčić, Z.. (2011). Resonance Frequency Analysis as a Reliable Criterion for Early Loading of Sandblasted/Acid-Etched Active Surface Implants Placed by the Osteotome Sinus Floor Elevation Technique. in International Journal of Oral & Maxillofacial Implants, 26(4), 718-724.
https://hdl.handle.net/21.15107/rcub_smile_1626
Marković A, Čolić S, Dražić R, Gačić B, Todorović A, Stajčić Z. Resonance Frequency Analysis as a Reliable Criterion for Early Loading of Sandblasted/Acid-Etched Active Surface Implants Placed by the Osteotome Sinus Floor Elevation Technique. in International Journal of Oral & Maxillofacial Implants. 2011;26(4):718-724.
https://hdl.handle.net/21.15107/rcub_smile_1626 .
Marković, Aleksa, Čolić, Snježana, Dražić, Radojica, Gačić, Bojan, Todorović, Aleksandar, Stajčić, Zoran, "Resonance Frequency Analysis as a Reliable Criterion for Early Loading of Sandblasted/Acid-Etched Active Surface Implants Placed by the Osteotome Sinus Floor Elevation Technique" in International Journal of Oral & Maxillofacial Implants, 26, no. 4 (2011):718-724,
https://hdl.handle.net/21.15107/rcub_smile_1626 .

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB
 

 

All of DSpaceCommunitiesAuthorsTitlesSubjectsThis institutionAuthorsTitlesSubjects

Statistics

View Usage Statistics

DSpace software copyright © 2002-2015  DuraSpace
About Smile – School of dental Medicine dIgitaL archivE | Send Feedback

OpenAIRERCUB